| Plan Review Stops For Permit 21051280 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-10-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-05 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-05 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-04 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-04 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2021-10-04 09:41:15 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. PROVIDE A SITE PLAN/DRAINAGE PLAN/BOUNDRY LINE | | | SURVEY (CORRECTED) | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | | | | | | | 2. PROVIDE AN ENERGY SUBMITTAL. (CORRECTED) | | | DESIGNER SHALL INDICTATE THE R VALUE OF CEILING AND | | | WALL INSULATION ON THE PLANS. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 3. PROVIDE COVER SHEET AND INSTALLATION INSTRUCTIONS | | | FOR EXTERIOR DOORS. CORRECTED (NOA SUBMITTED) | | | THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE | | | VERSION, AND STATUS, FBC R 301. | | | (COVER SHEETS ARE NOT REQUIRED FOR MIAMI DADE NOAS.) | | | | | | 4. THE PLANS CALL FOR IMPACT RATED WINDOWS. NOA | | | 20-0402.01 IS FOR NON-IMPACT RATED WINDOWS. (CORRECTED) | | | NOA 20-0528.04 SUBMITTED FOR REVIEW. | | | EITHER PROVIDE AN NOA FOR IMPACT RATED WINDOWS OR A | | | SCHEDULE FOR OPENING PROTECTIVE DEVICES OR ASSEMBLIES | | | WITH CURRENT PRODUCT APPROVALS OF DEVICES. | | | | | | 5. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS. (NOT | | | CORRECTED) | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | NEW COMMENT: REVISE PLAN PAGES A-1 AND A-2. REPRESENT | | | WHAT WINDOWS ARE BEING INSTALLED. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-06 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-06 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2021-07-06 10:10:27 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1. PROVIDE A SITE PLAN/DRAINAGE PLAN/BOUNDRY LINE | | | SURVEY | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | | | | 2. PROVIDE AN ENERGY SUBMITTAL. (NOT CORRECTED. PROVIDE | | | R VALUE FOR CLOSED ROOF) | | | DESIGNER SHALL INDICTATE THE R VALUE OF CEILING AND | | | WALL INSULATION ON THE PLANS. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 3. PROVIDE COVER SHEET AND INSTALLATION INSTRUCTIONS | | | FOR EXTERIOR DOORS. CORRECTED | | | THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE | | | VERSION, AND STATUS, FBC R 301. | | | (COVER SHEETS ARE NOT REQUIRED FOR MIAMI DADE NOAS.) | | | | | | 4. THE PLANS CALL FOR IMPACT RATED WINDOWS. NOA | | | 20-0402.01 IS FOR NON-IMPACT RATED WINDOWS. | | | EITHER PROVIDE AN NOA FOR IMPACT RATED WINDOWS OR A | | | SCHEDULE FOR OPENING NPROTECTIVE DEVICES OR ASSEMBLIES | | | WITH CURRENT PRODUCT APPROVALS OF DEVICES. | | | | | | 5. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS. (NOT | | | CORRECTED) | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-10 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-10 |
Time |
16:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-06-10 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-06-10 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2021-06-10 16:09:06 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | | SEC. 105.1. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-04 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-08 |
Time |
14:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-07-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-06 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-25 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-08-30 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-08-24 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2021-08-30 09:34:01 | RECEIPT MU-2021-041903-0000 $0.00 NO FEES DUE. LEM | | 2021-08-24 11:58:09 | 8/24/21 UPLOADED IMPACT FEE QUESTIONNAIRE - EMAILED PBC | | | IMPACT FEE OFFICE. CC |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-07-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-06 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-06 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2021-07-06 09:40:25 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-20 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-20 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2021-09-20 10:43:54 | APPROVED WITH PRIVISO: THE OUTDOOR GRILL SHALL BE | | | INSTALLED PER THE MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS. A HOOD OVER THE GRILL MAY BE REQUIRED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-11 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-11 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2021-06-11 10:30:00 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21051280 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS NEW | | | EDITION. FBC EC R401 | | | | | | 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FBC EC R403.7 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-06-10 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-06-10 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2021-06-10 16:11:57 | 06/10/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-04 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-04 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-07-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-06 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-06 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2021-07-06 09:47:19 | PLAN REVIEW ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOFING PERMIT REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2. PROVIDE PRODUCT APPROVALS | | | R905.1.1.1UNDERLAYMENT FOR ASPHALT, METAL, MINERAL | | | SURFACED, SLATE AND SLATE-TYPE ROOF COVERINGS. | | | UNDERLAYMENT FOR ASPHALT SHINGLES, METAL ROOF SHINGLES, | | | MINERAL SURFACED ROLL ROOFING, SLATE AND SLATE-TYPE | | | SHINGLES, AND METAL ROOF PANELS SHALL COMPLY WITH ONE | | | OF THE FOLLOWING METHODS: | | | 1.THE ENTIRE ROOF DECK SHALL BE COVERED WITH AN | | | APPROVED SELF-ADHERING POLYMER-MODIFIED BITUMEN | | | UNDERLAYMENT COMPLYING WITH ASTM D1970 | | | 2.A MINIMUM 4-INCH-WIDE (102 MM) STRIP OF SELF-ADHERING | | | POLYMER-MODIFIED BITUMEN MEMBRANE COMPLYING WITH ASTM | | | D1970 | | | 3.A MINIMUM 33/4-INCH WIDE (96 MM) STRIP OF | | | SELF-ADHERING FLEXIBLE FLASHING TAPE COMPLYING WITH | | | AAMA 711, LEVEL 3 | | | 4.TWO LAYERS OF ASTM D226 TYPE II OR ASTM D4869 TYPE | | | III OR TYPE IV UNDERLAYMENT SHALL BE INSTALLED AS | | | FOLLOW | | | 5.TWO LAYERS OF A REINFORCED SYNTHETIC UNDERLAYMENT | | | THAT HAS A PRODUCT APPROVAL AS AN ALTERNATIVE TO | | | UNDERLAYMENT COMPLYING WITH ASTM D22 | | | | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-09-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-09-20 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-09-20 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-06-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-11 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-11 |
Time |
10:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-09-27 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-09-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2021-09-27 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-06-22 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-06-22 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2021-06-22 |
Time |
|
Sent To |
I |
|
| Notes |
|
|