Plan Review Details - Permit 21051280
Plan Review Stops For Permit 21051280
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-10-05 Cont ID  
Sent By cthroop Date 2021-10-05 Time 10:53 Rev Time 0.00
Received By cthroop Date 2021-10-05 Time 10:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-10-04 Cont ID  
Sent By cthroop Date 2021-10-04 Time 09:35 Rev Time 0.00
Received By cthroop Date 2021-10-04 Time 09:35 Sent To  
Notes
2021-10-04 09:41:15PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 1. PROVIDE A SITE PLAN/DRAINAGE PLAN/BOUNDRY LINE
 SURVEY (CORRECTED)
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
  
  
 2. PROVIDE AN ENERGY SUBMITTAL. (CORRECTED)
 DESIGNER SHALL INDICTATE THE R VALUE OF CEILING AND
 WALL INSULATION ON THE PLANS.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 3. PROVIDE COVER SHEET AND INSTALLATION INSTRUCTIONS
 FOR EXTERIOR DOORS. CORRECTED (NOA SUBMITTED)
 THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE
 VERSION, AND STATUS, FBC R 301.
 (COVER SHEETS ARE NOT REQUIRED FOR MIAMI DADE NOAS.)
  
 4. THE PLANS CALL FOR IMPACT RATED WINDOWS. NOA
 20-0402.01 IS FOR NON-IMPACT RATED WINDOWS. (CORRECTED)
 NOA 20-0528.04 SUBMITTED FOR REVIEW.
 EITHER PROVIDE AN NOA FOR IMPACT RATED WINDOWS OR A
 SCHEDULE FOR OPENING PROTECTIVE DEVICES OR ASSEMBLIES
 WITH CURRENT PRODUCT APPROVALS OF DEVICES.
  
 5. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS. (NOT
 CORRECTED)
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 NEW COMMENT: REVISE PLAN PAGES A-1 AND A-2. REPRESENT
 WHAT WINDOWS ARE BEING INSTALLED.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-06 Cont ID  
Sent By cthroop Date 2021-07-06 Time 09:47 Rev Time 0.00
Received By cthroop Date 2021-07-06 Time 08:25 Sent To  
Notes
2021-07-06 10:10:27PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1. PROVIDE A SITE PLAN/DRAINAGE PLAN/BOUNDRY LINE
 SURVEY
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
  
 FBC R401.3 SITE DRAINAGE
 PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH
 FBC R401.3 DRAINAGE.
  
 2. PROVIDE AN ENERGY SUBMITTAL. (NOT CORRECTED. PROVIDE
 R VALUE FOR CLOSED ROOF)
 DESIGNER SHALL INDICTATE THE R VALUE OF CEILING AND
 WALL INSULATION ON THE PLANS.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 3. PROVIDE COVER SHEET AND INSTALLATION INSTRUCTIONS
 FOR EXTERIOR DOORS. CORRECTED
 THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE
 VERSION, AND STATUS, FBC R 301.
 (COVER SHEETS ARE NOT REQUIRED FOR MIAMI DADE NOAS.)
  
 4. THE PLANS CALL FOR IMPACT RATED WINDOWS. NOA
 20-0402.01 IS FOR NON-IMPACT RATED WINDOWS.
 EITHER PROVIDE AN NOA FOR IMPACT RATED WINDOWS OR A
 SCHEDULE FOR OPENING NPROTECTIVE DEVICES OR ASSEMBLIES
 WITH CURRENT PRODUCT APPROVALS OF DEVICES.
  
 5. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS. (NOT
 CORRECTED)
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-06-10 Cont ID  
Sent By jleahy Date 2021-06-10 Time 17:05 Rev Time 0.00
Received By jleahy Date 2021-06-10 Time 16:49 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2021-06-10 Cont ID  
Sent By lcrespo Date 2021-06-10 Time 16:12 Rev Time 0.00
Received By lcrespo Date 2021-06-10 Time 16:12 Sent To  
Notes
2021-06-10 16:09:06GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN
 PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS
 WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR
 FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-10-04 Cont ID  
Sent By cthroop Date 2021-10-04 Time 09:57 Rev Time 0.00
Received By cthroop Date 2021-09-08 Time 14:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-06 Cont ID  
Sent By cthroop Date 2021-07-06 Time 10:11 Rev Time 0.00
Received By cthroop Date 2021-05-25 Time 09:12 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-08-30 Cont ID  
Sent By lmarchan Date 2021-08-30 Time 09:34 Rev Time 0.00
Received By lmarchan Date 2021-08-24 Time 11:57 Sent To  
Notes
2021-08-30 09:34:01RECEIPT MU-2021-041903-0000 $0.00 NO FEES DUE. LEM
2021-08-24 11:58:098/24/21 UPLOADED IMPACT FEE QUESTIONNAIRE - EMAILED PBC
 IMPACT FEE OFFICE. CC

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-07-06 Cont ID  
Sent By cthroop Date 2021-07-06 Time 09:39 Rev Time 0.00
Received By cthroop Date 2021-07-06 Time 09:39 Sent To  
Notes
2021-07-06 09:40:25PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT
 LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO
 THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF.
 THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ
 B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
 UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE
 RECEIPT TO PROJECT DOX OR EMAIL IT TO
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-09-20 Cont ID  
Sent By medwards Date 2021-09-20 Time 10:42 Rev Time 0.00
Received By medwards Date 2021-09-20 Time 10:42 Sent To  
Notes
2021-09-20 10:43:54APPROVED WITH PRIVISO: THE OUTDOOR GRILL SHALL BE
 INSTALLED PER THE MANUFACTURER'S INSTALLATION
 INSTRUCTIONS. A HOOD OVER THE GRILL MAY BE REQUIRED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-06-11 Cont ID  
Sent By medwards Date 2021-06-11 Time 10:29 Rev Time 0.00
Received By medwards Date 2021-06-11 Time 10:20 Sent To  
Notes
2021-06-11 10:30:001ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21051280
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS NEW
 EDITION. FBC EC R401
  
 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FBC EC R403.7
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-06-10 Cont ID  
Sent By lcrespo Date 2021-06-10 Time 16:08 Rev Time 0.00
Received By lcrespo Date 2021-06-10 Time 16:08 Sent To  
Notes
2021-06-10 16:11:5706/10/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2021-10-04 Cont ID  
Sent By cthroop Date 2021-10-04 Time 09:56 Rev Time 0.00
Received By cthroop Date 2021-10-04 Time 09:55 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2021-07-06 Cont ID  
Sent By cthroop Date 2021-07-06 Time 09:46 Rev Time 0.00
Received By cthroop Date 2021-07-06 Time 08:25 Sent To  
Notes
2021-07-06 09:47:19PLAN REVIEW ROOFING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING PERMIT REQUIRED.
 PERMITS - 105.1 REQUIRED.
  
 2. PROVIDE PRODUCT APPROVALS
 R905.1.1.1UNDERLAYMENT FOR ASPHALT, METAL, MINERAL
 SURFACED, SLATE AND SLATE-TYPE ROOF COVERINGS.
 UNDERLAYMENT FOR ASPHALT SHINGLES, METAL ROOF SHINGLES,
 MINERAL SURFACED ROLL ROOFING, SLATE AND SLATE-TYPE
 SHINGLES, AND METAL ROOF PANELS SHALL COMPLY WITH ONE
 OF THE FOLLOWING METHODS:
 1.THE ENTIRE ROOF DECK SHALL BE COVERED WITH AN
 APPROVED SELF-ADHERING POLYMER-MODIFIED BITUMEN
 UNDERLAYMENT COMPLYING WITH ASTM D1970
 2.A MINIMUM 4-INCH-WIDE (102 MM) STRIP OF SELF-ADHERING
 POLYMER-MODIFIED BITUMEN MEMBRANE COMPLYING WITH ASTM
 D1970
 3.A MINIMUM 33/4-INCH WIDE (96 MM) STRIP OF
 SELF-ADHERING FLEXIBLE FLASHING TAPE COMPLYING WITH
 AAMA 711, LEVEL 3
 4.TWO LAYERS OF ASTM D226 TYPE II OR ASTM D4869 TYPE
 III OR TYPE IV UNDERLAYMENT SHALL BE INSTALLED AS
 FOLLOW
 5.TWO LAYERS OF A REINFORCED SYNTHETIC UNDERLAYMENT
 THAT HAS A PRODUCT APPROVAL AS AN ALTERNATIVE TO
 UNDERLAYMENT COMPLYING WITH ASTM D22
  
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-09-20 Cont ID  
Sent By medwards Date 2021-09-20 Time 10:47 Rev Time 0.00
Received By medwards Date 2021-09-20 Time 10:47 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-06-11 Cont ID  
Sent By medwards Date 2021-06-11 Time 10:43 Rev Time 0.00
Received By medwards Date 2021-06-11 Time 10:43 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-09-27 Cont ID  
Sent By rthermid Date 2021-09-27 Time   Rev Time 0.00
Received By rthermid Date 2021-09-27 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-06-22 Cont ID  
Sent By rthermid Date 2021-06-22 Time   Rev Time  
Received By rthermid Date 2021-06-22 Time   Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved