| Plan Review Stops For Permit 21051240 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2021-07-07 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-07-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2021-07-07 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2021-06-02 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-06-02 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2021-06-02 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-02 11:10:15 | PLEASE ADDRESS FIRE COMMENTS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-07-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-07-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-07-07 |
Time |
12:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-05-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-05-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-05-27 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2021-05-27 13:12:48 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THE PLAN SHEET INDICATES CPVC 2 1/2" FOR THE | | | UNDERGROUND. | | | | | | PER NFPA 24, THAT DOES NOT MEET THE STANDARD PER TABLE | | | 10.1.1 | | | | | | 10.1* PIPING MATERIALS. | | | 10.1.1* LISTING. PIPING SHALL BE LISTED FOR FIRE | | | PROTECTION SERVICE | | | OR SHALL COMPLY WITH THE STANDARDS IN TABLE 10.1.1. | | | | | | PLASTIC | | | POLYVINYL CHLORIDE (PVC) PRESSURE PIPE, 4 IN. | | | THROUGH 12 IN., FOR WATER DISTRIBUTION - AWWA C900 | | | | | | POLYVINYL CHLORIDE (PVC) PRESSURE PIPE, 14 IN. | | | THROUGH 48 IN., FOR WATER DISTRIBUTION - AWWA C905 | | | | | | THERE WERE NO MANUFACTURES SPECIFICATION SHEETS PROVIED | | | SHOWING COMPLIANCE | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-07-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-07 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-06 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-06-17 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-06-17 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2021-06-17 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-07-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-07 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-07 |
Time |
13:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-11 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-11 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2021-06-11 10:52:24 | SEE FIRE REVIEWERS COMMENTS. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2021-07-07 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2021-07-07 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2021-07-07 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2021-07-07 13:10:07 | PERMIT IS FOR UNDERGROUND FIRE LINE. A SEPARATE PERMIT | | | IS REQUIRED FOR THE BACKFLOW DEVICE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-07-06 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-07-06 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-07-06 16:50:01 | 21051240 5201 VILLAGE BLVD | | | | | | | | | PLUMBING COMMENTS: DENIED | | | | | | | | | SEE WPB FBC 107.3.4.3 CERTIFICATION BY CONTRACTOR. | | | PLEASE NOTE THE EXCEPTION TO ENGINEERED PLANS UNDER | | | 471.003(H) ELECTRICAL/ PLUMBING/ MECHANICAL, | | | 481.229(1)(C) (BUILDING) REQUIRES THE CONTRACTOR FOR | | | THAT TRADE THAT WILL BE LICENSED IN THAT TRADE, WILL | | | ALSO BE THE CONTRACTOR THAT DESIGNS THE SYSTEM UNDER | | | THAT TRADE. THE CONTRACTOR (QUALIFIER) THAT CREATED / | | | DRAWN THE SET OF PLANS WILL NEED TO IDENTIFY THEMSELVES | | | AS THE AUTHOR OF THE PLANS. PLEASE PRINT YOUR NAME, | | | SIGN YOUR NAME AND LICENSE NUMBER FOR THE TRADE YOU ARE | | | LICENSED IN AND PLANS DRAWN. FOR EACH TRADE THE | | | CONTRACTOR RESPONSIBLE FOR THE DESIGN UNDER THE TRADE | | | LICENSED IN MUST PRINT THEIR NAME, SIGN THEIR NAME AND | | | LICENSE NUMBER, NOTE THESE PLANS APPEAR TO BE DRAWN BY | | | ONE INDIVIDUAL, THEY WOULD HAVE TO BE LICENSED AS A | | | BUILDING, ELECTRICAL AND PLUMBING CONTRACTOR TO SUBMIT | | | ALL THESE TRADES UNDER ONE SHEET. | | | | | | PLEASE NOTE THAT WHEN SCANNED DRAWINGS ARE SUBMITTED | | | WITH CONTRACTOR'S PRINTED NAME, SIGNATURE AND LICENSE | | | NUMBER IN ACCORDANCE WITH WPB FBC 107.2.1, A PAPER PLAN | | | WITH WET SIGNATURE SHALL BE PROVIDED TO THE BUILDING | | | DEPARTMENT FOR HARD RECORD FILE PRIOR TO ISSUANCE OF A | | | PERMIT. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-06-17 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-06-17 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2021-06-17 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2021-06-17 10:18:52 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | REFER TO FIRE REVIEWER'S COMMENTS. | | | | | | IT IS NOTED THAT THE DOUBLE DETECTOR CHECK VALVE IS | | | COMPLIANT WITH FBC PL 608.1, TABLE 608.1. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS | | | | | | 21051240 5201 VILLAGE BLVD | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2021-07-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-07 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-07 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-06-17 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-06-17 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2021-06-17 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|