| Plan Review Stops For Permit 21050958 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2021-08-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-08-11 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-08-11 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2021-08-11 14:29:30 | SPACE USED TO BE SUITE 101, SINGLE TENANT TAKING OVER | | | THE WHOLE BUILDING PROJECT WILL BE IN 2 PHASES, ALL | | | SUITE NUMBERS WILL BE ELIMINATED LEAVING THE PRIMARY | | | ADDRESS OF 471 SPENCER DR, WHICH IS CURRENTLY THE ONLY | | | APPROVED ADDRESS IN OUR SYSTEMS. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2021-07-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-07-28 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-07-28 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2021-07-28 08:59:49 | PLEASE CONTACT [email protected] OR CALL 561-805-6659 SO | | | THAT THE SUITE NUMBERS CAN BE ASSIGNED |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-05-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-05-19 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-05-19 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2021-05-19 11:01:09 | SUITES ARE NOT CURRENTLY IN OUR SYSTEMS. ON THE PLANS | | | YOU INDICATE THAT THERE ARE THREE SUITES IN THIS | | | BUILDING, HOWEVER THE STREET VIEW DOES SHOW THE | | | ENTRANCES THAT YOU ARE INDICATING, YOU ARE SHOWING | | | THREE ENTRANCES ON THE EAST SIDE OF THE BUILDING AND | | | TWO ENTRANCES ON THE WEST SIDE OF THE BUILDING, BUT | | | THIS IS NOT SHOWN ON THE AERIALS. ALSO, SUITES 101, 105 | | | AND 110 WOULD NOT BE THE RECOMMENDED NUMBERING FOR | | | THESE SUITES. PLEASE CONTACT [email protected] TO DISCUSS | | | THE ADDRESSING OF THIS PROJECT. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2021-08-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-05 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-05 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2021-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-24 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-24 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2021-06-24 10:58:24 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2021-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-24 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-24 |
Time |
10:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-06-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-01 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-01 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-05-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2021-05-21 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2021-05-21 17:10:01 | THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE | | | CURRENT CODES IN EFFECT IN THIS JURISDICTION AT THE | | | TIME OF THE ORIGINAL APPLICATION. PERFORMANCE OF THIS | | | REVIEW SHALL NOT ALLEVIATE THE APPLICANT FROM FULL | | | RESPONSIBILITY TO COMPLY WITH ALL APPLICABLE | | | REQUIREMENTS. | | | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | | CEILINGS MAY REQUIRE AN EVALUATION OF THE FIRE ALARM | | | SYSTEM OR DEVICES FOR CODE COVERAGE AND COMPLIANCE BY | | | CERTIFIED CONTRACTORS. ANY AND ALL WORK ON THE FIRE | | | ALARM AND/OR FIRE SPRINKLER SYSTEMS, INCLUDING DEMO, | | | SHALL BE DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-08-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-05 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-07-27 |
Time |
12:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-24 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-05-20 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-08-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-05 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-05 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-03 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-03 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-03 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2021-06-03 09:45:58 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21050958 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE OUTDOOR AIR CALCULATIONS BASED ON THE | | | 2020 FBC M 403.3.1.1 AND TABLE 403.3.1.1 NOT BY THE | | | ARCHITECT?S OCCUPANT COUNT OR FBC 809.2 ( THERE IS NO | | | SUCH SECTION IN THE 2020 FBC). | | | | | | 2) PLEASE SHOW THE RETURN AIR PATH FOR AHU-3 AND AHU-4. | | | FBC M 601.6 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-06-07 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-06-07 |
Time |
22:14 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-06-07 |
Time |
19:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-08-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-05 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-05 |
Time |
09:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-06-03 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-03 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-03 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|