| Plan Review Stops For Permit 21050878 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-07-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-07-21 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-07-21 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2021-07-21 10:32:17 | BUILDING AUDIT OK. | | | ONLY PROFLEX SUPER SIM-90 FLOORING UNDERLAYMENT WAS | | | REVIEWED. | | | SEE SUPPORTING DOCUMENTS. JG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-07-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-07-15 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-07-15 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2021-07-15 14:19:06 | 07/15/21 RESPONSE TO DENIS SHEA EMAIL . | | | | | | MR. GOMEZ, | | | DO THE ATTACHED PDF?S TAKE CARE OF YOUR COMMENTS? | | | PLEASE GIVE ME A CALL AT THE NUMBER BELOW WHEN YOU GET | | | A CHANCE SO WE CAN DISCUSS THIS. | | | THANK YOU | | | DENIS SHEA | | | OFFICE: (561) 586-8255 | | | EMAIL: [email protected] | | | CASTILLA AND GODOY COMPANIES | | | STATE OF FLORIDA CERTIFIED GENERAL CONTRACTOR | | | | | | RESPONSE: | | | 1) STC TESTING SUBMITTED IS FOR AN 8" CONCRETE SLAB | | | WITH A SUSPENDED GYPSUM BOARD CEILING. THIS TEST IS FOR | | | AN ASSEMBLY THAT DOESN'T MATCH EXISTING ASSEMBLY. | | | EXISTING ASSEMBLY IN THIS BUILDING IS A 6" CONCRETE | | | SLAB WITH NO ACOUSTICAL CEILING. NEED TO PROVIDE COPY | | | OF TEST DONE ON THE 6" SLAB AND NO ACOUSTICAL CEILING. | | | | | | 2) PLEASE COORDINATE WITH PRIVATE PROVIDER. ANY | | | RESUBMITAL NEEDS TO BE REVIEWED/APPROVED BY THE PRIVATE | | | PROVIDER TO AVOID CONFLICTS/DELAYS. | | | | | | | | | | | | PREVIOUS COMMENT: | | | | | | 2ND AUDIT | | | RESIDENTIAL(R2) ALTERATION . | | | PERMIT #21050878 | | | | | | 1- OK | | | | | | ORIGINAL COMMENT | | | 2- FLOORING SOUND INSULATION MATERIAL: | | | A) OK | | | | | | B) PROVIDE COPY OF THE SOUND TRANSMISSION CLASS (STC) | | | TEST DONE IN ACCORDANCE WITH ASTM E 90 AS REQUIRED BY | | | SEC. 1207.2 OF FBC 7TH EDITION (2020). | | | | | | RESPONSE: | | | SOUND TRANSMISSION CLASS (STC) TEST WAS NOT SUBMITTED. | | | NEED TO PROVIDE COPY OF THE TEST AS DONE WITH THE | | | IMPACT AND FLAME SPREAD TESTS SUBMITTED. | | | NOTE: CRACK ISOLATION AND SOUND MEMBRANE DATA SHEET | | | SUBMITTED IS NOT A COPY OF THE STC TEST AND THE | | | INFORMATION ON THIS DATA SHEET IS ONLY FOR SOUND TEST | | | DONE ON 8" CONCRETE SLAB WITH A SUSPENDED DRYWALL | | | CEILING. SEE FOOTNOTE BELOW THE TECHNICAL DATA ITEM #4. | | | THIS DATA SHEET DOESN'T APPLY TO THIS PROJECT. THIS IS | | | WHY WE ASK FOR COPY OF THE TEST. | | | | | | | | | C) OK. | | | | | | NOTE: TEST SAMPLES TO MATCH BUILDING FLOOR/CEILING | | | CONSTRUCTION AND PROPOSED FLOOR FINISH. ALSO, THERE ARE | | | TESTS FOR 6" OR 8" CONCRETE SLABS WITH OR WITHOUT | | | ACOUSTICAL CEILING. TYPICALLY THERE ARE NOT SUSPENDED | | | ACOUSTICAL CEILINGS IN THESE BUILDINGS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-07-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-07-14 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-07-14 |
Time |
18:21 |
Sent To |
|
|
| Notes |
| 2021-07-14 18:57:44 | 2ND AUDIT | | | RESIDENTIAL(R2) ALTERATION . | | | PERMIT #21050878 | | | | | | 1- OK | | | | | | ORIGINAL COMMENT | | | 2- FLOORING SOUND INSULATION MATERIAL: | | | | | | A) OK | | | | | | B) PROVIDE COPY OF THE SOUND TRANSMISSION CLASS (STC) | | | TEST DONE IN ACCORDANCE WITH ASTM E 90 AS REQUIRED BY | | | SEC. 1207.2 OF FBC 7TH EDITION (2020). | | | | | | RESPONSE: | | | SOUND TRANSMISSION CLASS (STC) TEST WAS NOT SUBMITTED. | | | NEED TO PROVIDE COPY OF THE TEST AS DONE WITH THE | | | IMPACT AND FLAME SPREAD TESTS SUBMITTED. | | | NOTE: CRACK ISOLATION AND SOUND MEMBRANE DATA SHEET | | | SUBMITTED IS NOT A COPY OF THE STC TEST AND THE | | | INFORMATION ON THIS DATA SHEET IS ONLY FOR SOUND TEST | | | DONE ON 8" CONCRETE SLAB WITH A SUSPENDED DRYWALL | | | CEILING. SEE FOOTNOTE BELOW THE TECHNICAL DATA ITEM #4. | | | THIS DATA SHEET DOESN'T APPLY TO THIS PROJECT. THIS IS | | | WHY WE ASK FOR COPY OF THE TEST. | | | | | | C) OK. | | | | | | NOTE: TEST SAMPLES TO MATCH BUILDING FLOOR/CEILING | | | CONSTRUCTION AND PROPOSED FLOOR FINISH. ALSO, THERE ARE | | | TESTS FOR 6" OR 8" CONCRETE SLABS WITH OR WITHOUT | | | ACOUSTICAL CEILING. TYPICALLY THERE ARE NOT SUSPENDED | | | ACOUSTICAL CEILINGS IN THESE BUILDINGS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-07-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-07-01 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-07-01 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2021-07-01 13:34:35 | AUDIT | | | RESIDENTIAL(R2) ALTERATION . | | | PERMIT #21050878 | | | | | | 1- PLANS SHOW REMOVAL OF DRYWALL AND INSTALLATION OF | | | TOWEL BAR IN THE EXISTING SHAFT: | | | A)PLANS DON'T PROVIDE INFORMATION SHOWING HOW THE FIRE | | | RATING INTEGRITY OF THE CHASE IS GOING TO BE KEPT. | | | THERE ARE NO DETAILS/SPECIFICATIONS OF APPROVED FIRE | | | RATED CHASE ASSEMBLY. PROVIDE DETAILS/SPECIFICATIONS OF | | | APPROVED EXISTING ASSEMBLY. AND, PROVIDE COMPLETE | | | DETAILS/SPECIFICATIONS OF APPROVED RETROFIT ASSEMBLY. | | | SEC. 801.3 FBC-EXISTING BUILDING. SEC. 713 | | | FBC-BUILDING. | | | | | | B)PLANS DON'T PROVIDE INFORMATION SHOWING PENETRATION | | | PROTECTION AS REQUIRED BY SEC. 713.8.2 FBC-BUILDING. | | | SEC. 801.3 FBC-EXISTING BUILDING. | | | | | | 2- PLANS DON'T PROVIDE INFORMATION FOR THE FLOORING | | | UNDERLAYMENT. SEE REQUIRED INFORMATION BELOW. | | | SEC. 801.3 FBC-EXISTING BUILDING. | | | SEC. 720.1 OF FBC 7TH EDITION (2020). | | | SEC. 1207.2 OF FBC 7TH EDITION (2020). | | | SEC. 1207.3 OF FBC 7TH EDITION (2020). | | | | | | FLOORING SOUND INSULATION MATERIAL: | | | A) PROVIDE COPY OF THE FLAME SPREAD INDEX AND SMOKE | | | DEVELOPED INDEX TEST DONE IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723 AS REQUIRED BY SEC. 720.1 OF FBC 7TH EDITION | | | (2020). | | | | | | B) PROVIDE COPY OF THE SOUND TRANSMISSION CLASS (STC) | | | TEST DONE IN ACCORDANCE WITH ASTM E 90 AS REQUIRED BY | | | SEC. 1207.2 OF FBC 7TH EDITION (2020). | | | | | | C) PROVIDE COPY OF THE IMPACT INSULATION CLASS (IIC) | | | TEST DONE IN ACCORDANCE WITH ASTM E 492 AS REQUIRED BY | | | SEC. 1207.3 OF FBC 7TH EDITION (2020). | | | | | | NOTE: TEST SAMPLES TO MATCH BUILDING FLOOR/CEILING | | | CONSTRUCTION AND PROPOSED FLOOR FINISH. ALSO, THERE ARE | | | TESTS FOR 6" OR 8" CONCRETE SLABS WITH OR WITHOUT | | | ACOUSTICAL CEILING. TYPICALLY THERE ARE NOT SUSPENDED | | | ACOUSTICAL CEILINGS IN THESE BUILDINGS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-07-22 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-07-22 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-07-22 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2021-07-22 08:14:01 | AUDIT ONLY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-07-01 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-07-01 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-07-01 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2021-07-01 08:54:03 | AUDIT ONLY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-07-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-07-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-07-14 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-06-11 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-06-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-06-11 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-07-22 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-07-22 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-07-20 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-07-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-07-20 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-07-13 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-07-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-07-07 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-07-06 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-07-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-07-01 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-06-11 |
Time |
07:33 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-06-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-06-11 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-06-04 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-07-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-07-21 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-07-21 |
Time |
07:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-06-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-06-30 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-06-30 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
4 |
Status |
P |
Date |
2021-07-22 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2021-07-22 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2021-07-22 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2021-07-22 14:29:21 | PRIVATE PROVIDER FOR PLAN REVIEW IS APPROVED | | | THERE ARE THREE AFFIDAVITS FOR CODE COMPLIANCE. ALL | | | THRE | | | AFFIDAVITS ARE REQUIRED TO COVER THE DRAWINGS AND | | | SUPPORTING DOCUMENTS | | | RICHARD GATHRIGHT | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
3 |
Status |
F |
Date |
2021-07-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-07-07 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-07-07 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2021-07-07 08:16:15 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FS553.791, THIS PROJECT IS PRIVATE PROVIDER PLAN | | | REVIEW. PLANS ARE TO BE REVIEWED BY THE PRIVATE | | | PROVIDER PRIOR TO SUBMITTAL TO BUILDING DIVISION AUDIT. | | | FIRST ROUND DOCUMENTS WERE STAMPED BY THE PRIVATE | | | PROVIDER AND AN AFFIDAVIT WAS PROVIDED, BUT A NEW PAGE | | | AND SUPPORTING DOCUMENTS WERE SUBMITTED. | | | | | | | | | | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2021-06-28 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2021-06-28 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2021-06-28 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2021-06-28 11:41:40 | PRIVATE PROVIDER DOCUMENTS FOR INSURANCE AND RESUMES | | | REVIEWED APPROVED | | | DOCUMENTS PROVIDED BY THE CONTRACTOR AND WERE UPLOADED | | | | | | RICHARD GATHRIGHT |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2021-06-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-06-14 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-06-14 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2021-06-14 07:45:16 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FS553.791 | | | | | | NOTICE TO BUILDING OFFICIAL (PLAN REVIEW & INSPECTIONS) | | | - OK | | | PLAN REVIEW COMPLIANCE AFFIDAVIT - OK | | | | | | PROVIDE INSURANCE CERTIFICATE, RESUME(S) FS553.791 | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
N |
Date |
2021-07-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-07-07 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-07-07 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-06-28 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2021-06-28 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2021-06-28 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2021-06-28 11:52:12 | VALUE WAS INCORRECT ON SUBMITTED APPLICATION. | | | RESUBMITTED APPLICATION HAS CORRECT VALUE AND DOES NOT | | | REUIRE ARCHITECT | | | RICHARD GATHRIGHT | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-06-04 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-06-04 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-06-04 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2021-06-04 14:38:21 | VALUE OF WORK REQUIRES REGISTERED ARCHITECT SIGNATURE | | | AND SEAL. RICHARD GATHRIGHT IS GOING TO SPEAK TO | | | CONTRACTOR. ROOUTED TO STORAGE. EQ |
|
|