Plan Review Details - Permit 21050878
Plan Review Stops For Permit 21050878
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-07-21 Cont ID  
Sent By jgomez Date 2021-07-21 Time 10:30 Rev Time 0.00
Received By jgomez Date 2021-07-21 Time 09:55 Sent To  
Notes
2021-07-21 10:32:17BUILDING AUDIT OK.
 ONLY PROFLEX SUPER SIM-90 FLOORING UNDERLAYMENT WAS
 REVIEWED.
 SEE SUPPORTING DOCUMENTS. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-07-15 Cont ID  
Sent By jgomez Date 2021-07-15 Time 14:19 Rev Time 0.00
Received By jgomez Date 2021-07-15 Time 14:06 Sent To  
Notes
2021-07-15 14:19:0607/15/21 RESPONSE TO DENIS SHEA EMAIL .
  
 MR. GOMEZ,
 DO THE ATTACHED PDF?S TAKE CARE OF YOUR COMMENTS?
 PLEASE GIVE ME A CALL AT THE NUMBER BELOW WHEN YOU GET
 A CHANCE SO WE CAN DISCUSS THIS.
 THANK YOU
 DENIS SHEA
 OFFICE: (561) 586-8255
 EMAIL: [email protected]
 CASTILLA AND GODOY COMPANIES
 STATE OF FLORIDA CERTIFIED GENERAL CONTRACTOR
  
 RESPONSE:
 1) STC TESTING SUBMITTED IS FOR AN 8" CONCRETE SLAB
 WITH A SUSPENDED GYPSUM BOARD CEILING. THIS TEST IS FOR
 AN ASSEMBLY THAT DOESN'T MATCH EXISTING ASSEMBLY.
 EXISTING ASSEMBLY IN THIS BUILDING IS A 6" CONCRETE
 SLAB WITH NO ACOUSTICAL CEILING. NEED TO PROVIDE COPY
 OF TEST DONE ON THE 6" SLAB AND NO ACOUSTICAL CEILING.
  
 2) PLEASE COORDINATE WITH PRIVATE PROVIDER. ANY
 RESUBMITAL NEEDS TO BE REVIEWED/APPROVED BY THE PRIVATE
 PROVIDER TO AVOID CONFLICTS/DELAYS.
  
  
  
 PREVIOUS COMMENT:
  
 2ND AUDIT
 RESIDENTIAL(R2) ALTERATION .
 PERMIT #21050878
  
 1- OK
  
 ORIGINAL COMMENT
 2- FLOORING SOUND INSULATION MATERIAL:
 A) OK
  
 B) PROVIDE COPY OF THE SOUND TRANSMISSION CLASS (STC)
 TEST DONE IN ACCORDANCE WITH ASTM E 90 AS REQUIRED BY
 SEC. 1207.2 OF FBC 7TH EDITION (2020).
  
 RESPONSE:
 SOUND TRANSMISSION CLASS (STC) TEST WAS NOT SUBMITTED.
 NEED TO PROVIDE COPY OF THE TEST AS DONE WITH THE
 IMPACT AND FLAME SPREAD TESTS SUBMITTED.
 NOTE: CRACK ISOLATION AND SOUND MEMBRANE DATA SHEET
 SUBMITTED IS NOT A COPY OF THE STC TEST AND THE
 INFORMATION ON THIS DATA SHEET IS ONLY FOR SOUND TEST
 DONE ON 8" CONCRETE SLAB WITH A SUSPENDED DRYWALL
 CEILING. SEE FOOTNOTE BELOW THE TECHNICAL DATA ITEM #4.
 THIS DATA SHEET DOESN'T APPLY TO THIS PROJECT. THIS IS
 WHY WE ASK FOR COPY OF THE TEST.
  
  
 C) OK.
  
 NOTE: TEST SAMPLES TO MATCH BUILDING FLOOR/CEILING
 CONSTRUCTION AND PROPOSED FLOOR FINISH. ALSO, THERE ARE
 TESTS FOR 6" OR 8" CONCRETE SLABS WITH OR WITHOUT
 ACOUSTICAL CEILING. TYPICALLY THERE ARE NOT SUSPENDED
 ACOUSTICAL CEILINGS IN THESE BUILDINGS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-07-14 Cont ID  
Sent By jgomez Date 2021-07-14 Time 18:57 Rev Time 0.00
Received By jgomez Date 2021-07-14 Time 18:21 Sent To  
Notes
2021-07-14 18:57:442ND AUDIT
 RESIDENTIAL(R2) ALTERATION .
 PERMIT #21050878
  
 1- OK
  
 ORIGINAL COMMENT
 2- FLOORING SOUND INSULATION MATERIAL:
  
 A) OK
  
 B) PROVIDE COPY OF THE SOUND TRANSMISSION CLASS (STC)
 TEST DONE IN ACCORDANCE WITH ASTM E 90 AS REQUIRED BY
 SEC. 1207.2 OF FBC 7TH EDITION (2020).
  
 RESPONSE:
 SOUND TRANSMISSION CLASS (STC) TEST WAS NOT SUBMITTED.
 NEED TO PROVIDE COPY OF THE TEST AS DONE WITH THE
 IMPACT AND FLAME SPREAD TESTS SUBMITTED.
 NOTE: CRACK ISOLATION AND SOUND MEMBRANE DATA SHEET
 SUBMITTED IS NOT A COPY OF THE STC TEST AND THE
 INFORMATION ON THIS DATA SHEET IS ONLY FOR SOUND TEST
 DONE ON 8" CONCRETE SLAB WITH A SUSPENDED DRYWALL
 CEILING. SEE FOOTNOTE BELOW THE TECHNICAL DATA ITEM #4.
 THIS DATA SHEET DOESN'T APPLY TO THIS PROJECT. THIS IS
 WHY WE ASK FOR COPY OF THE TEST.
  
 C) OK.
  
 NOTE: TEST SAMPLES TO MATCH BUILDING FLOOR/CEILING
 CONSTRUCTION AND PROPOSED FLOOR FINISH. ALSO, THERE ARE
 TESTS FOR 6" OR 8" CONCRETE SLABS WITH OR WITHOUT
 ACOUSTICAL CEILING. TYPICALLY THERE ARE NOT SUSPENDED
 ACOUSTICAL CEILINGS IN THESE BUILDINGS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-07-01 Cont ID  
Sent By jgomez Date 2021-07-01 Time 13:29 Rev Time 0.00
Received By jgomez Date 2021-07-01 Time 09:24 Sent To  
Notes
2021-07-01 13:34:35AUDIT
 RESIDENTIAL(R2) ALTERATION .
 PERMIT #21050878
  
 1- PLANS SHOW REMOVAL OF DRYWALL AND INSTALLATION OF
 TOWEL BAR IN THE EXISTING SHAFT:
 A)PLANS DON'T PROVIDE INFORMATION SHOWING HOW THE FIRE
 RATING INTEGRITY OF THE CHASE IS GOING TO BE KEPT.
 THERE ARE NO DETAILS/SPECIFICATIONS OF APPROVED FIRE
 RATED CHASE ASSEMBLY. PROVIDE DETAILS/SPECIFICATIONS OF
 APPROVED EXISTING ASSEMBLY. AND, PROVIDE COMPLETE
 DETAILS/SPECIFICATIONS OF APPROVED RETROFIT ASSEMBLY.
 SEC. 801.3 FBC-EXISTING BUILDING. SEC. 713
 FBC-BUILDING.
  
 B)PLANS DON'T PROVIDE INFORMATION SHOWING PENETRATION
 PROTECTION AS REQUIRED BY SEC. 713.8.2 FBC-BUILDING.
 SEC. 801.3 FBC-EXISTING BUILDING.
  
 2- PLANS DON'T PROVIDE INFORMATION FOR THE FLOORING
 UNDERLAYMENT. SEE REQUIRED INFORMATION BELOW.
 SEC. 801.3 FBC-EXISTING BUILDING.
 SEC. 720.1 OF FBC 7TH EDITION (2020).
 SEC. 1207.2 OF FBC 7TH EDITION (2020).
 SEC. 1207.3 OF FBC 7TH EDITION (2020).
  
 FLOORING SOUND INSULATION MATERIAL:
 A) PROVIDE COPY OF THE FLAME SPREAD INDEX AND SMOKE
 DEVELOPED INDEX TEST DONE IN ACCORDANCE WITH ASTM E 84
 OR UL 723 AS REQUIRED BY SEC. 720.1 OF FBC 7TH EDITION
 (2020).
  
 B) PROVIDE COPY OF THE SOUND TRANSMISSION CLASS (STC)
 TEST DONE IN ACCORDANCE WITH ASTM E 90 AS REQUIRED BY
 SEC. 1207.2 OF FBC 7TH EDITION (2020).
  
 C) PROVIDE COPY OF THE IMPACT INSULATION CLASS (IIC)
 TEST DONE IN ACCORDANCE WITH ASTM E 492 AS REQUIRED BY
 SEC. 1207.3 OF FBC 7TH EDITION (2020).
  
 NOTE: TEST SAMPLES TO MATCH BUILDING FLOOR/CEILING
 CONSTRUCTION AND PROPOSED FLOOR FINISH. ALSO, THERE ARE
 TESTS FOR 6" OR 8" CONCRETE SLABS WITH OR WITHOUT
 ACOUSTICAL CEILING. TYPICALLY THERE ARE NOT SUSPENDED
 ACOUSTICAL CEILINGS IN THESE BUILDINGS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-07-22 Cont ID  
Sent By ppetty Date 2021-07-22 Time 08:13 Rev Time 0.00
Received By ppetty Date 2021-07-22 Time 08:05 Sent To  
Notes
2021-07-22 08:14:01AUDIT ONLY

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-07-01 Cont ID  
Sent By ppetty Date 2021-07-01 Time 08:53 Rev Time 0.00
Received By ppetty Date 2021-07-01 Time 08:37 Sent To  
Notes
2021-07-01 08:54:03AUDIT ONLY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-07-14 Cont ID  
Sent By pleduc Date 2021-07-14 Time   Rev Time 0.00
Received By pleduc Date 2021-07-14 Time 10:50 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-06-11 Cont ID  
Sent By pleduc Date 2021-06-11 Time   Rev Time 0.00
Received By pleduc Date 2021-06-11 Time 14:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2021-07-22 Cont ID  
Sent By lmarchan Date 2021-07-22 Time 14:37 Rev Time 0.00
Received By lmarchan Date 2021-07-20 Time 14:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-07-20 Cont ID  
Sent By jgomez Date 2021-07-20 Time 14:29 Rev Time 0.00
Received By jgomez Date 2021-07-13 Time 14:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-07-07 Cont ID  
Sent By shill Date 2021-07-07 Time 08:17 Rev Time 0.00
Received By shill Date 2021-07-06 Time 10:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-07-01 Cont ID  
Sent By jgomez Date 2021-07-01 Time 13:35 Rev Time 0.00
Received By jgomez Date 2021-06-11 Time 07:33 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-06-14 Cont ID  
Sent By shill Date 2021-06-11 Time 07:32 Rev Time 0.00
Received By shill Date 2021-06-04 Time 09:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-07-21 Cont ID  
Sent By ccole Date 2021-07-21 Time 08:03 Rev Time 0.00
Received By ccole Date 2021-07-21 Time 07:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-06-30 Cont ID  
Sent By ccole Date 2021-06-30 Time 10:46 Rev Time 0.00
Received By ccole Date 2021-06-30 Time 10:39 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 4 Status P Date 2021-07-22 Cont ID  
Sent By rgathrig Date 2021-07-22 Time 14:27 Rev Time 0.00
Received By rgathrig Date 2021-07-22 Time 14:27 Sent To  
Notes
2021-07-22 14:29:21PRIVATE PROVIDER FOR PLAN REVIEW IS APPROVED
 THERE ARE THREE AFFIDAVITS FOR CODE COMPLIANCE. ALL
 THRE
 AFFIDAVITS ARE REQUIRED TO COVER THE DRAWINGS AND
 SUPPORTING DOCUMENTS
 RICHARD GATHRIGHT
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status F Date 2021-07-07 Cont ID  
Sent By shill Date 2021-07-07 Time 08:13 Rev Time 0.00
Received By shill Date 2021-07-07 Time 08:13 Sent To  
Notes
2021-07-07 08:16:15****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FS553.791, THIS PROJECT IS PRIVATE PROVIDER PLAN
 REVIEW. PLANS ARE TO BE REVIEWED BY THE PRIVATE
 PROVIDER PRIOR TO SUBMITTAL TO BUILDING DIVISION AUDIT.
 FIRST ROUND DOCUMENTS WERE STAMPED BY THE PRIVATE
 PROVIDER AND AN AFFIDAVIT WAS PROVIDED, BUT A NEW PAGE
 AND SUPPORTING DOCUMENTS WERE SUBMITTED.
  
  
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status P Date 2021-06-28 Cont ID  
Sent By rgathrig Date 2021-06-28 Time 11:35 Rev Time 0.00
Received By rgathrig Date 2021-06-28 Time 11:35 Sent To  
Notes
2021-06-28 11:41:40PRIVATE PROVIDER DOCUMENTS FOR INSURANCE AND RESUMES
 REVIEWED APPROVED
 DOCUMENTS PROVIDED BY THE CONTRACTOR AND WERE UPLOADED
  
 RICHARD GATHRIGHT

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2021-06-14 Cont ID  
Sent By shill Date 2021-06-14 Time 07:41 Rev Time 0.00
Received By shill Date 2021-06-14 Time 07:41 Sent To  
Notes
2021-06-14 07:45:16****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FS553.791
  
 NOTICE TO BUILDING OFFICIAL (PLAN REVIEW & INSPECTIONS)
 - OK
 PLAN REVIEW COMPLIANCE AFFIDAVIT - OK
  
 PROVIDE INSURANCE CERTIFICATE, RESUME(S) FS553.791
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status N Date 2021-07-07 Cont ID  
Sent By shill Date 2021-07-07 Time 08:17 Rev Time 0.00
Received By shill Date 2021-07-07 Time 08:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-06-28 Cont ID  
Sent By rgathrig Date 2021-06-28 Time 11:50 Rev Time 0.00
Received By rgathrig Date 2021-06-28 Time 11:50 Sent To  
Notes
2021-06-28 11:52:12VALUE WAS INCORRECT ON SUBMITTED APPLICATION.
 RESUBMITTED APPLICATION HAS CORRECT VALUE AND DOES NOT
 REUIRE ARCHITECT
 RICHARD GATHRIGHT
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-06-04 Cont ID  
Sent By equinone Date 2021-06-04 Time 14:19 Rev Time 0.00
Received By equinone Date 2021-06-04 Time 14:19 Sent To  
Notes
2021-06-04 14:38:21VALUE OF WORK REQUIRES REGISTERED ARCHITECT SIGNATURE
 AND SEAL. RICHARD GATHRIGHT IS GOING TO SPEAK TO
 CONTRACTOR. ROOUTED TO STORAGE. EQ