| Plan Review Stops For Permit 21050854 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-12-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-22 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-22 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-13 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-13 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2021-10-13 10:21:05 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: WORK DESCRIPTION STATES "REPLACE EXACT SIZE | | | GENERATOR". CITY RECORDS SHOW THE EXISTING GENERATOR IS | | | A 20KW UNIT. REPLACEMENT GENERATOR IS A 30KW UNIT. | | | ALSO, THE LOCATION IS DIFFERENT THAN THE EXISTING UNIT. | | | | | | 1. PROVIDE A STRUCTURAL SLAB WITH ATTACHMENT DETAIL. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PROVIDE DESIGN WIND LOADS FOR PROPOSED GENERATOR. | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-12-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-22 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-22 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-13 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-13 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2021-10-13 09:55:23 | ELECTRICAL PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ELECTRICAL CONTRACTOR SHALL SIGN ELECTRICAL | | | CALCULATIONS AND RISER DIAGRAHM. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-02-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-02-17 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-15 |
Time |
11:24 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-01-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-01-04 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-01-03 |
Time |
12:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-12-23 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2021-12-23 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2021-11-30 |
Time |
07:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-13 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-20 |
Time |
17:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-02-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-02-17 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-17 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2022-02-17 12:59:18 | SITE SPECIFIC GENERATOR PAD DRAWING 22-49984 W/ DIGITAL | | | SIGNATURE. JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-01-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-01-04 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-01-04 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2022-01-04 14:08:53 | THE GENERATOR PAD ENGINEERING DOES NOT HAVE THE | | | ENGINEER'S DIGITAL SIGNATURE ON IT. ELECTRONICALLY | | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ARCHITECT | | | OR ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE | | | THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER | | | VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE | | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | | ARCHITECT OR ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE | | | AND SEAL IS REQUIRED TO BE ON THE DRAWINGS. NO | | | PHOTOCOPY OR OTHER FACSIMILES OF THE SIGNATURE ARE | | | ACCEPTABLE. FS 481 & 61G1 OR FS 471 & 61G15 | | | NOTE: THE PAD DRAWINGS THAT WERE SUBMITTED ARE NOT FOR | | | THE CUMMINS RS30 GENERATOR. THE GENERATOR IS 94" LONG | | | AND THE PAD IS ONLY 54" LONG. SUBMIT A SIGNED AND | | | SEALED PAD DRAWING THAT IS FOR THE CUMMINS RS 30 | | | GENERATOR. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-12-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-22 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-22 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2021-12-22 14:51:11 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: GENERATOR PAD ENGINEERING | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-10-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-13 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-13 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2021-10-13 09:56:44 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: ELECTRICAL CALCULATIONS AND RISER DIAGRAHM. | | | | | | | | | 1. THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE | | | THEIR PRINTED NAME AND SIGNATURE ON PLAN SHEETS UNDER | | | THEIR AUTHORITY. | | | 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1, SECTION 107.2.1. | | | | | | 2. EITHER UPLOAD DOCUMENTS VIA THE PROJECTDOX PORTAL | | | WITH SIGNATURE OF DESIGNER AS APPLICABLE; USE THE | | | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT OR DROP | | | OFF (OR MAIL) ONE PAPER ORIGINAL WITH CONTRACTORS/O/B | | | SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-12-23 |
|
|
Cont ID |
|
| Sent By |
vb |
Date |
2021-12-23 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2021-12-23 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
av |
Date |
2021-10-04 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2021-10-04 |
Time |
|
Sent To |
I |
|
| Notes |
|
|