Plan Review Details - Permit 21050747
| Plan Review Stops For Permit 21050747 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-10-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-01 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-01 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-11 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-10 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2021-06-11 07:58:55 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: CONDITIONAL LETTER REGARDING WINDOW MULLIONS. | | | | | | 1. IF WOOD WILL BE USED IN LIEU OF A MULLION THAT HAS | | | BEEN TESTED AND CERTIFIED THROUG AN NOA OR PRODUCT | | | APPROVAL, IT MUST BE DESIGNED TO WITHSTAND THE WIND | | | LOADS AT THAT OPENING. | | | PROVIDE A STRUCTURAL DETAIL OF THE PROPOSED WOOD | | | MULLIONS. INCLUDE ATTACHMENT CONNECTORS AND FASTENERS. | | | STRUCTURAL DETAIL MUST BE SIGNED BY THE DESIGNER. | | | | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | | | | | | 2021-06-08 10:00:46 | ADDITIONAL INFORMATION RECEIVED. PLEASE REVIEW AS | | | NORMAL. - AARON X1424 | | | | | | HISTORIC IS WAITING FOR ADDITIONAL INFORMATION. PLEASE | | | WAIT ON THE REVIEW. AARON - X1424 | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2021-06-10 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2021-06-01 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2021-06-10 09:04:33 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | | CONDITION(S): | | | PROPOSED CONDITIONS, CONFIRM THAT THE PROPOSED PROJECT | | | CAN MEET THESE REQUIREMENTS. | | | 1. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE | | | ORIGINAL WINDOW FRAME OPENING (X-AXIS AND Y-AXIS) AND | | | MATCH THE LOCATION/DEPTH (Z-AXIS) OF THE ORIGINAL | | | WINDOWS. | | | 2. THE EXISTING MULLION SHALL REMAIN OR BE REPLACED | | | WITH A MULLION OF MATCHING WIDTH AND PLACEMENT. | | | | | | CLARIFICATION: THE WINDOW MULLION SHALL EXTEND BEYOND | | | THE WINDOW CASINGS IN WOOD OR ALUMINUM. | | | | | | 3. ALL STREET OR SIDEWALK FACING GLASS SHALL BE CLEAR. | | | ALL NON-STREET FACING GLASS SHALL BE CLEAR OR CLEAR | | | WITH LOW-E COATING. NO TINT. OBSCURED TEXTURED GLASS | | | MAY BE USED ON NON-STREET FACING BATHROOMS ONLY. | | | | | | AARON BORNGRABER, AICP | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-10-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-01 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-15 |
Time |
07:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-06-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-11 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-20 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-10-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-01 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-01 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2021-10-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-01 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-01 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2021-06-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-11 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-10 |
Time |
16:44 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy