| Plan Review Stops For Permit 21050678 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
N |
Date |
2021-05-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-05-14 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-05-14 |
Time |
11:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
P |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-06 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-31 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2022-03-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-03-25 |
Time |
18:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-03-23 |
Time |
10:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-18 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-16 |
Time |
08:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-03-11 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-03-11 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-03-10 |
Time |
08:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-08 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-01 |
Time |
06:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-02-25 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-02-18 |
Time |
10:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-12-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-16 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-02 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-11-01 |
Time |
18:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-10-28 |
Time |
12:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-06 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-06 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2022-03-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-25 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-25 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2022-03-25 14:02:50 | SHEE M-1 MOST RECENT SUBMITTAL DOES NOT INCLUDE THE | | | AHU-8 IN THE HEAT LOAD SUMMARY TABLE. THERE ARE 2 M-1 | | | SHEETS THAT HAVE BEEN SUBMITTED, THE EARLIER VERSION | | | DOES HAVE THE AHU-8 LISTED IN THE HEAT LOAD SUMMARY | | | TABLE. PLEASE HAVE THE DESIGNER TO ADD A REVISION | | | NUMBER TO THE NEWLY REVISED DRAWING THAT WILL BE | | | SUBMITTED SHOWING THE AHU-8 BACK IN THE HEAT LOAD | | | SUMMARY. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-18 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-18 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2022-03-18 14:27:11 | PRIVATE PROVIDER MECHANICAL AUDIT | | | | | | CONFLICT BETWEEN ARCHITECTURAL DRAWINGS AND THE ENERGY | | | CALCULATIONS: | | | | | | THE ENERGY CALCULATIONS DATED 2/27/2022 FROM KAREN | | | OLIVER SUBMITTED IN THIS LATEST SUBMITTAL SHOWS ON PAGE | | | 4 OF 6 THAT MECHANICAL SYSTEM 8 IN THE GARAGE HAS 2 18 | | | FT BY 8 FT INSULATED GARAGE DOORS. THE MECHANICAL | | | DRAWING SUBMITTED WITH THIS REVISION SHOWS 2- 9FT X 8 | | | FT GARAGE DOORS TO THE WEST SIDE AND 1-18 FT GARAGE | | | DOOR ON THE SOUTH SIDE. THE ARCHITECTURAL DRAWINGS SHOW | | | 4- 9FT X 8FT DOORS TOTAL. I CALLED HILLARY MUSSER AND | | | ASKED HOW MANY GARAGE DOORS WERE INSTALLED AT THIS | | | LOCATION AND SHE TOLD ME THERE WERE 3 TOTAL. 2 SMALL | | | DOORS AND 1 LARGE DOOR MADE TO LOOK LIKE 2. PLEASE | | | PROVIDE ARCHITECTURAL/STRUCTURAL DRAWINGS TO SUPPORT | | | WHAT IS ACTUALLY INSTALLED AT THIS RESIDENCE. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-08 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-08 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2022-03-08 16:31:34 | 2ND CYCLE MECHANICAL PLAN REVIEW AUDIT | | | | | | THE ENERGY CALCULATIONS DATED 07/23/2020 SIGNED BY | | | KAREN OLIVER IS FOR THE ENTIRE HOUSE BUT DOES NOT | | | INCLUDE THE GARAGE AREA. I ASKED FOR THE ENERGY | | | CALCULATIONS FOR THE GARAGE AREA AS THE AS BUILT | | | DRAWINGS NOW SHOW THAT THE GARAGE IS A CONDITIONED | | | SPACE. THE GARAGE ENERGY CALCULATIONS SHOULD REFLECT | | | THE GARAGE DOORS. FBC EC R402 | | | | | | THE ORIGINAL ENERGY CALCULATIONS DO NOT REFLECT WHAT | | | THE AS BUILT DRAWINGS SHOW. PLEASE PROVIDE THE UPDATED | | | ENERGY CALCULATIONS SHOWING THE SAME UNITS AS THE AS | | | BUILT DRAWINGS INDICATE FOR THE MAIN HOUSE. FBC EC | | | R403.7 | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-16 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-16 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2021-12-16 09:42:13 | 1ST AUDIT FBC-2020 MECHANICAL | | | PERMIT-21050678 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN AUDIT RESULTS: DENIED. | | | | | | 1) THE ORIGINAL APPROVED DRAWINGS DID NOT HAVE A | | | MECHANICAL UNIT FOR THE GARAGE. THIS REVISED DRAWING | | | SHOWS AN AHU TO DEHUMIDIFY THE GARAGE. PLEASE EITHER | | | PROVIDE THE ENERGY CALCULATIONS AND MECHANICAL | | | EQUIPMENT SIZING CALCULATIONS FOR THE GARAGE OR PROVIDE | | | A HUMIDITY UNIT ONLY. FBC 107.2.1 | | | | | | 2) THE ORIGINAL DRAWINGS WERE DESIGNED BY ELLIS | | | CONSULTING BEN ELLIS PE HIS DESIGN HAD 3 DRAWINGS: M-1, | | | M-2 AND M-3. THE REVISED DRAWING FROM SMYTH AIR | | | CONDITIONING INC. DOES NOT INCLUDE M-1. THIS SHEET, | | | M-1, FROM THE ORIGINAL DESIGNER MR. BEN ELLIS EXPLAINS | | | IN DETAIL ON SHEET M-1 THAT IF THERE IS A CHANGE FROM | | | HIS ORIGINAL DESIGN IT MUST BE SENT BACK TO HIM FOR HIS | | | APPROVAL AND STAMP. PLEASE CORRECT THIS AND SUBMIT A | | | REVISION THAT HAS MR. ELLIS SIGNATURE ON ALL 3 SHEETS. | | | THE MECHANICAL CONTRACTOR CAN SUBMIT EVERYTHING RELATED | | | TO THE MECHANICAL DESIGN OF THIS PROJECT INCLUDING A | | | NEW SHEET M-1 AND A LETTER OF INTENT TO BE THE | | | RESPONSIBLE PARTY FOR THIS DESIGN. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
9 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-04-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2022-04-01 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
8 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-03-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2022-03-25 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
7 |
Status |
P |
Date |
2022-03-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-17 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-17 |
Time |
09:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
6 |
Status |
F |
Date |
2022-03-11 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-03-11 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-03-11 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2022-03-11 16:06:25 | AFFIDADIT FAILED BECAUSE UNDER PLAN SHEETS; MUANUAL J | | | R588M GARAGE A/C FOR DEHUMIDIFICATION BY LISA SMITH | | | DATED OCTOBER 9, 2021 AND THE DOCUMENT SAYS OCTOBER 19, | | | 2021. WOULD YOU PLEASE CORRECT PER THE WPB AMENDMENTS | | | TO THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
5 |
Status |
P |
Date |
2022-03-04 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-03-04 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-03-04 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
4 |
Status |
F |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-02-25 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-02-25 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2022-02-25 16:27:27 | THE MANUAL J CALCULATIONS FOR THE GARAGE ARE NOT ON THE | | | PRIVATE PROVIDERS AFFIDAVIT PLAN REVIEW DOCUMENT. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
3 |
Status |
P |
Date |
2022-02-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-22 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-22 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
2 |
Status |
F |
Date |
2021-12-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-16 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-16 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2021-12-16 09:41:11 | THE AFFIDAVITS ARE APPROVED FOR THIS CYCLE OF AUDITS | | | BUT THERE WILL BE A REQUIRED 3RD CYCLE AS THE | | | MECHANICAL AUDIT HAS FAILED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-11-01 |
Time |
18:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-11-01 |
Time |
18:31 |
Sent To |
|
|
| Notes |
| 2021-11-01 18:34:10 | FS553.791 | | | | | | THE AFFIDAVIT REFERS TO "SHOP DRAWING BY MECHANICAL | | | CONTRACTOR" . . . "REVIEWED BY BEN ELLIS, PE, EOR". | | | | | | SHOP DRAWINGS ARE NOT REQUIRED TO BE SUBMITTED. CHANGES | | | TO THE DRAWINGS REQUIRE A REVISION TO THE DRAWINGS. | | | SHOP DRAWINGS BY THE CONTRACTOR CANNOT REVISE THE | | | DESIGN BY THE MECHANICAL ENGINEER. | | | | | | EITHER SUBMIT REVISED SHEETS M2 AND M3 PREPARED BY THE | | | ENGINEER, OR SUBMIT ALL PAGES PREPARED BY THE | | | MECHANICAL CONTRACTOR SO IT IS CLEAR WHO IS TAKING | | | RESPONSIBILITY FOR THE DESIGN, FBC 107.2.1. | | | | | | | | | | | | |
|
|