Plan Review Details - Permit 21050675
Plan Review Stops For Permit 21050675
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-06-23 Cont ID  
Sent By ppetty Date 2021-06-23 Time 09:10 Rev Time 0.00
Received By ppetty Date 2021-06-23 Time 08:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-05-20 Cont ID  
Sent By ppetty Date 2021-05-20 Time 10:40 Rev Time 0.00
Received By ppetty Date 2021-05-20 Time 10:33 Sent To  
Notes
2021-05-20 10:41:06PLEASE SEE F/D NOTES

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-06-22 Cont ID  
Sent By pleduc Date 2021-06-22 Time   Rev Time 0.00
Received By pleduc Date 2021-06-22 Time 10:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-05-19 Cont ID  
Sent By pleduc Date 2021-05-19 Time   Rev Time 0.00
Received By pleduc Date 2021-05-19 Time 13:16 Sent To  
Notes
2021-05-19 13:37:09THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE ARE NO ADDRESS ON EACH SHEET NOR WITHIN THE
 TITLE BLOCK OF EACH SHEET.
  
 PLEASE PROVIDE THE CORRECT ADDTESS WITHIN THE TITLE
 BLOCK OF EACH SHEET
  
  
 2) THERE IS NO INDICATION OF A SEQUENCE OF OPERATION.
  
 THOUGH THIS IS A REPLACEMENT PANEL A SEQUENCE OF
 OPERATION IS REQUIRED.
  
 PLEASE PROVIDE THE SEQUENCE OF OPERATION FOR EACH
 APPLICABLE DEVICE.
  
  
 3) THERE IS NO VOLTAGE DROP NOR BATTERY CALCULATIONS.
  
 THERE IS ALSO NO INDICATION THAT THE EXISTING
 CALCULATIONS ARE THE SAME FOR THIS NEW PANEL.
  
 PLEASE REVIEW AND PROVIDE THE APPLICABLE NEW
 CLAULATIONS OR A NOTE INDICATING THEY ARE UNCHANGED.
  
  
 4) PLEASE ENSURE THAT ALL DEVICES ARE TESTED AND A
 PROPERLY COMPLETED REORD OF COMPLETION IS PROVIDED TO
 THE FIRE INSPECTOR ON FIRE INSPECTION.
  
 THE TESTING OF DEVICES WILL BE AT THE DISCRETION OF THE
 FIRE INSPECTOR.
  
  
  
 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-06-28 Cont ID  
Sent By medwards Date 2021-06-28 Time 09:11 Rev Time 0.00
Received By medwards Date 2021-06-21 Time 06:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-28 Cont ID  
Sent By medwards Date 2021-05-28 Time 11:23 Rev Time 0.00
Received By medwards Date 2021-05-14 Time 15:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-06-28 Cont ID  
Sent By medwards Date 2021-06-28 Time 09:11 Rev Time 0.00
Received By medwards Date 2021-06-28 Time 08:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-05-28 Cont ID  
Sent By medwards Date 2021-05-28 Time 11:22 Rev Time 0.00
Received By medwards Date 2021-05-28 Time 11:22 Sent To  
Notes
2021-05-28 11:23:20PLEASE SEE FIRE REVIEWER'S COMMENTS.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-06-28 Cont ID  
Sent By medwards Date 2021-06-28 Time 09:11 Rev Time 0.00
Received By medwards Date 2021-06-28 Time 09:11 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-05-14 Cont ID  
Sent By equinone Date 2021-05-14 Time 16:24 Rev Time 0.00
Received By equinone Date 2021-05-14 Time 16:24 Sent To  
Notes
2021-05-14 16:24:57PAPER DRAWINGS SUBMITTED WITH ORIGINAL SEAL AND
 SIGNATURE. ROUTED TO STORAGE. EQ