Plan Review Details - Permit 21050674
| Plan Review Stops For Permit 21050674 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-07-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-03 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-03 |
Time |
07:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-06-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-06-18 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-06-18 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2021-06-18 16:40:26 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC R 301, ON THE INSTALLATION SCHEDULE YOU PROPOSE | | | LAG SCREWS, AND ON THE PRODUCT APPROVAL YOU HAVE | | | CIRCLED LAG SCREWS, BUT THAT FASTENER IS FOR WOOD | | | SUBSTRATE (SEE THE NAME OF THE CHART WHERE YOU CIRCLED | | | THE SPACING). YOU ALSO PROPOSE AN EDGE DISTANCE OF | | | .75", THAT IS FOR WOOD. ON THE INSTALLATION SCHEDULE | | | YOU STATE THAT THE SUBSTRATE IS BLOCK/CONCRETE. | | | | | | A COMPLETE REVIEW CANNOT BE DONE DUE TO INCONSISTENT | | | INFORMATION. PROPOSED INSTALLATION IS FOR WOOD | | | SUBSTRATE, INSTALLATION SCHEDULE STATES ITS | | | BLOCK/CONCRETE. REVISE INSTALLATION SCHEDULE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-05-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-29 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-29 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2021-05-29 09:21:10 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: SHUTTER SCHEDULE: | | | | | | 1. ANCHOR TYPE IS SPECIFIED AS LAG SCREW. ANCHOR TYPE | | | PER CONNECTION TYPE C5 SPECIFIES TAPCONS OR DEWALT | | | ULTRACONS. | | | PLEASE CORRECT OR CLARIFY? | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-07-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-03 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-21 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-06-18 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-06-02 |
Time |
12:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-05-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-29 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-18 |
Time |
12:00 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy