Plan Review Details - Permit 21050671
| Plan Review Stops For Permit 21050671 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-08-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-08-09 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2021-08-09 11:41:05 | WORK IS BEING DONE ON 3065 S DIXIE HWY, UPDATED PERMIT. | | | SPOKE TO APPLICANT WHO STATED THAT WHEN THE CONTRACTOR | | | DOES A CHANGE OF CONTRACTOR THAT THE CORRECT ADDRESS | | | WILL BE REFLECTED ON THE APPLICATION FORM. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-05-13 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-05-13 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-05-13 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2021-05-13 17:12:12 | THIS PROJECT HAS BEEN ADDRESSED SPACE 8 IS NOT THE | | | ADDRESS FOR THIS PROJECT. PLEASE PROVIDE A SITE PLAN | | | SHOWING THE LOCATION OF THE UNIT, ESPECIALLY THE | | | ENTRANCE OF THE UNIT IN RELATIONSHIP TO THE SITE PLAN. | | | PLEASE EMAIL TO [email protected] |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2021-08-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-08-20 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-08-20 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2021-08-19 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-08-19 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-08-19 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2021-08-19 15:58:54 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | ASBESTOS REQUIREMENTS: | | | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2021-06-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-06-15 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-06-15 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2021-06-15 16:03:42 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-10-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-10-21 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-10-21 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2021-10-21 16:29:46 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW APPROVED. | | | | | | THE APPLICANT SUBMITTED THE SPECIFICATIONS FOR THE | | | LOUVER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-10-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-10-06 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-10-06 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2021-10-06 15:27:48 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE PROVIDE THE PRODUCT APPROVAL FOR | | | THE 16"X16"LOUVER AT THE LOWER SECTION OF WALL FOR | | | ROASTERS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-08-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-08-24 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-08-19 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2021-08-24 16:10:15 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 2ND BUILDING REVIEW DENIED: | | | | | | 1)FBC B 107.2.1, DISCREPANCY IN PLAN SHEETS C-1 & 1.3A | | | STILL EXIST. PLEASE CORRECT THE OCCUPANCY NUMBERS | | | TO MATCH. SHEET C-1 INDICATES 78 TOTAL NUMBER OF SEATS | | | AND SHEET 1.3A INDICATES 72 MINIMUM OCCUPANT | | | LOAD. | | | 2A) OK | | | 2B) OK | | | 2C) OK | | | 2D) OK | | | 3) OK | | | 4) OK | | | 5) OK | | | 6) FAILED, FBC B 1010.1.2.1, (PLAN SHEETS 1.0A & 1.3A) | | | THE DOOR STILL SHOWS SWINGING INWARD. THIS DOOR | | | MUST SWING OUTWARD AS IT IS AN EGRESS DOOR (PART OF A | | | MEANS OF EGRESS). | | | 7) FAILED, FBC B 1028.4.2, MORE INFORMATION IS REQUIRED | | | TO SHOW THE FIRE RATING HAS BEEN MET FOR THE WALL | | | AND WALL OPENINGS. ALSO, THE NEW CHASE DETAIL FOR THE | | | MECHANICAL (ROASTER) EXHAUST UNDER THE SOFFIT DOES | | | NOT APPEAR TO FIT THE SIDE OF THE BUILDING. THIS | | | BUILDING APPEARS TO BE THREE STORIES AT THIS LOCATION. | | | PLEASE | | | VERIFY. | | | 8) OK | | | 9) OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-06-15 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-06-15 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2021-06-15 16:02:02 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21050671 | | | ADD: 3111 S. DIXIE HWY. | | | CONT: TBD / TO BE DETERMINED | | | TEL: ?? | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. JUNE 15TH/ 2021 | | | ACTION: DENIED | | | | | | 1) DISCREPANCY IN PLANS. THE COVERSHEET C1 STATES THERE | | | IS 129 SEATS OR OCCUPANTS NOT COUNTING THE KITCHEN AREA | | | OR THE QUEUING AREA THAT WOULD ADD AN ADDITIONAL 20 | | | OCCUPANTS OR A TOTAL OF 92 OCCUPANTS. NEITHER SHEET | | | SHOWS ANY SEASONAL SEATING. 107.2.1.2. ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 2) SHEET 1.3A INDICATES 72 SEATS AND ONLY SHOW 1 | | | ACCESSIBLE SEAT. THE LIFE SAFETY SHEET DOES NOT SHOW | | | COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY CODE. | | | 2A) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE | | | CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT (72 X | | | 0.05 = 3.6 OR 4 ACCESSIBLE SEATS REQUIRED) OF THE | | | SEATING SPACES AND STANDING SPACES AT THE DINING | | | SURFACES SHALL COMPLY WITH 902. | | | | | | 2B) 226.2 DISPERSION. DINING SURFACES AND WORK SURFACES | | | REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED | | | THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING | | | SURFACES AND WORK SURFACES. | | | | | | 2C) 206.2.5 206.2.5 RESTAURANTS AND CAFETERIAS. IN | | | RESTAURANTS AND CAFETERIAS, AN ACCESSIBLE ROUTE SHALL | | | BE PROVIDED TO ALL DINING AREAS, INCLUDING RAISED OR | | | SUNKEN DINING AREAS, AND OUTDOOR DINING AREAS. | | | | | | 2D) 902.1. DINING SURFACES AND WORK SURFACES SHALL | | | COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 GENERAL. | | | DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS, | | | TABLES, LUNCH COUNTERS, AND BOOTHS. EXAMPLES OF WORK | | | SURFACES INCLUDE WRITING SURFACES, STUDY CARRELS, | | | STUDENT LABORATORY STATIONS, BABY CHANGING AND OTHER | | | TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON | | | COUNTERS, AND WHERE COVERED BY THE ADA SCOPING | | | PROVISIONS, EMPLOYEE WORKSTATIONS. | | | | | | 2D)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR | | | SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD | | | APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE | | | COMPLYING WITH 306 SHALL BE PROVIDED. | | | | | | 2D)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND | | | WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 3) THE SHEET 1.3A THE LIFE SAFETY PLAN DOES SHOW 2 | | | MEANS OF EGRESS, BUT THE PLANS DO NOT SHOW IF BOTH | | | EXITS ARE ACCESSIBLE. 2020 FBC-ACCESSIBILITY CODE | | | SECTION 207.1 MEANS OF EGRESS SHALL COMPLY WITH SECTION | | | 1003.2.13 OF THE INTERNATIONAL BUILDING CODE (2000 | | | EDITION AND 2001 SUPPLEMENT) OR SECTION 1007 OF THE | | | INTERNATIONAL BUILDING CODE (2003 EDITION). | | | | | | 2003 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS | | | IS REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY | | | ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE | | | SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS. | | | | | | 4) ON BOTH THE SHEETS 1.0A & 1.3A THE LIFE SAFETY SHEET | | | IT APPEARS THE FRONT ENTRY DOOR IS DRAWN AS BOTH A | | | LEFT-HAND AND ALSO A RIGHT-HAND OUTSWING DOOR. | | | ADDITIONAL INFORMATION IS REQUIRED. 107.2.1.2. | | | | | | 5) IN BOTH PLANS SHEET 1.0A AND 1.3A THE LIFE SAFETY | | | PLAN THERE IS AN ENCLOSED EXIT STAIRWAY WITH AN INSWING | | | DOOR NOT IN THE DIRECTION OF TRAVEL. 2020 FBC-B | | | 1010.1.2.1 DOOR SWING. | | | | | | 6) IN BOTH PLANS SHEET 1.0A AND 1.3A THE LIFE SAFETY | | | PLAN THERE IS AN ENCLOSED EXIT STAIRWAY WITH AN INSWING | | | DOOR NOT IN THE DIRECTION OF TRAVEL. BEYOND THAT FROM | | | THE NEW CAF? THERE IS ANOTHER EXIT DOOR TO WHAT APPEARS | | | TO BE AN EXIT PASSAGEWAY. JUST TO THE LEFT OF THE CAF? | | | EXIT DOOR THERE IS WHAT APPEARS TO BE 2 WINDOWS, THE | | | PLAN DOES NOT SHOW THIS AREA AS A BLOCK WALL. THE DOOR | | | SCHEDULE INDICATES EXISTING STEEL DOOR. SEE TABLE 716.5 | | | FOR WINDOW LISTINGS IN EXIT PASSAGEWAYS. | | | | | | 7) SHEETS 1.0A, 1.3A THE LIFE SAFETY PLAN, 1.1A THE | | | EQUIPMENT PLAN AT THE EQUIPMENT LABELED # 14 ROASTER | | | THERE ARE 2 CIRCLES ON THE EXTERIOR OF THE WALL. SHEET | | | 4.1M SHOWS AN INTAKE LOUVER AND AN EXHAUST SINGLE WALL | | | FLUE. IT APPEARS THAT YOU HAVE LEFT THE EXIT AT THE | | | STAIRWELL AND ARE IN WHAT APPEARS TO BE AN EGRESS | | | COURT. THE EGRESS COURT WILL NEED TO SHOW COMPLIANCE | | | WITH 1028.4.2 CONSTRUCTION AND CAPACITY FOR BOTH THE | | | NEW EXTERIOR METAL FRAMING , FRT. EXT. PLYWOOD AND | | | PAPER LATH TO MATCH BUILDING, PROVIDE THE THICKNESS | | | REQUIRED FOR 1 HOUR PROTECTION. PLEASE ALSO SHOW | | | PROTECTION FOR THE 12 X12 INTAKE LOUVER. PROVIDE A | | | STRUCTURAL DETAIL OF HOW THIS WALL SECTION IS TO BE | | | BUILT, WHAT IS THE WALL FRAMING GOING TO ANCHOR TOO. | | | 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 8) SHEET 1.4A DETAILS. SECTION 1-1.4A SHOWS AN EXISTING | | | PVC SANITARY PIPE. PLEASE SHOW ON EITHER THE EQUIPMENT | | | PLAN OR FLOOR PLAN WHERE THIS PIPE IS LOCATED. PLEASE | | | ALSO PROVIDE WITH WHAT MATERIALS THIS CHASE IS GOING TO | | | BE BUILT, PROVIDE TYPE OF FRAMING. SIZE AND SPACING OF | | | FRAMING, HOW IT WILL BE ANCHORED TO THE DECK ABOVE, | | | TYPE OF MATERIAL TO CREATE THE CHASE, THICKNESS AND IF | | | THE CHASE IS TO BE FIRE RATED OR NOT. 107.2.1.2. | | | 456.3.1. | | | | | | 9) SHEET 1.4A WATER CLOSET DETAIL B SHOWS THE TOILET | | | PAPER DISPENSER DIRECTLY IN FRONT OF THE TOILET. TOILET | | | PAPER DISPENSERS. 2020 FBC-ACCESS. CODE 604.7. THE | | | TOILET PAPER DISPENSER SHALL COMPLY WITH 309.4 AND | | | SHALL BE 7 INCHES MINIMUM TO 9 INCHES MAXIMUM IN FRONT | | | OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE | | | DISPENSER. | | | | | | 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | | RETIRED. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-23 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-23 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-08-10 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2021-08-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-06-01 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2021-06-01 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-22 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-22 |
Time |
08:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-19 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-18 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2021-10-19 11:21:37 | 3RD REVIEW FBC-2020 FUEL GAS | | | PERMIT- 21050671 | | | 10/19/21 | | | | | | CODES IN EFFECT: | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 3.1P: REFER TO PREVIOUSLY FAILED COMMENT #2 | | | FROM THE 1ST AND 2ND REVIEW PRINTED BELOW. PLEASE NOTE | | | THAT THE LETTER FROM THE PRIMO ROASTING CEO DOES NOT | | | PROVIDE INFORMATION OR EVIDENCE OF ANZI STANDARD | | | APPROVAL FOR THE GAS BURNER AND ASSOCIATED COMPONENTS- | | | SECTION 623.1 FBC FG. | | | FAILED. 3.0P & 3.1P: SUBMIT MANUFACTURER'S | | | SPECIFICATIONS FOR THE NEW COFFEE ROASTER- SECTION | | | 305.1 FBC FG. PLEASE HIGHLIGHT OR MARKUP THE SPEC TO | | | SHOW THE LISTING STANDARD, BTU LOAD, AND GAS INPUT | | | PRESSURE. THE SUBMITTED ROASTER SPECS DO NOT SHOW THE | | | LISTING STANDARD, GAS INPUT PRESSURE, OR CATEGORY OF | | | THE CATEGORY OF THE APPLIANCE. PLEASE REFER TO SECTIONS | | | 305.1 AND 623.1 FBC FG FOR LISTING REQUIREMENTS, AND | | | SECTION 410.2- INPUT PRESSURE IS REQUIRED FOR | | | DETERMINING THE REQUIRED SUPPLY PIPE PRESSURE AND | | | REGULATOR SELECTION. ALSO MISSING WITH THE SUBMITTAL | | | ARE MANUFACTURER?S INSTALLATION GUIDELINES FOR | | | SUPPLYING COMBUSTION AIR, MAKEUP AIR, AND PROPER | | | VENTING OF THE EQUIPMENT. THE CATEGORY OF THE APPLIANCE | | | NEEDS TO BE ESTABLISHED IN ORDER FOR A COMPLETE REVIEW | | | OF THE EXHAUST/VENT SYSTEM. PLEASE INDICATE CATEGORY I, | | | II, III, OR IV PER SECTIONS 202, 503.6.9.1, & & | | | 503.6.9.3. FBC FG. | | | | | | 2) SHEET 3.1P: REFER TO PREVIOUSLY FAILED COMMENT 3 | | | FROM THE 1ST AND 2ND REVIEWS PRINTED BELOW. THE REVISED | | | PLAN SHOWS THE COMBUSTION AIR OPENING IN THE WRONG | | | LOCATION. THE OPENING SHALL COMMENCE WITHIN 12 INCHES | | | OF THE TOP OF THE ENCLOSURE- SECTION 304.6.2 FBC FG. | | | FAILED. 3.0P & 3.1P: PROVIDE COMBUSTION AIR | | | CALCULATIONS FOR THE COFFEE ROASTER AND INDICATE HOW | | | THE AIR IS BEING SUPPLIED- SECTION 304.1 FBC FG. THE | | | RESPONSE NARRATIVE INDICATES INDOOR COMBUSTION AIR IS | | | TO BE USED, HOWEVER THE PLAN SHOWS A CALCULATION FOR | | | MECHANICALLY SUPPLIED AIR PER 304.9 USING AN OPENING TO | | | THE OUTDOORS: A) MECHANICAL AIR MUST BE SUPPLIED BY AN | | | AIR SUPPLY SYSTEM- MEANING CONDUCTED FROM A SUPPLY | | | UNIT. COMBUSTION AIR THROUGH ONE WALL OPENING SHALL | | | COMPLY WITH 304.6.2- 1 SQ. INCH PER 3000 BTUH. SEE | | | COMMENT #3 FOR COMBUSTION AIR/VENTING COMPLIANCES. | | | | | | 3) SHEETS 4.0M & 4.1M: REFER TO PREVIOUS REVIEW COMMENT | | | #4 PRINTED BELOW. | | | FAILED. 3.0P & 3.1P: THE TYPE AND SIZE OF | | | EXHAUST/VENTING SYSTEM IS DEPENDENT ON THE CATEGORY OF | | | THE APPLIANCE. PLEASE INDICATE CATEGORY I, II, III, OR | | | IV PER SECTIONS 202, 503.6.9.1 & 503.6.9.3.FBC FG. | | | A) CLARIFY HOW THE SYSTEM WAS DESIGNED- SUBMIT COFFEE | | | ROASTERS VENTING/MAKEUP-COMBUSTION AIR SYSTEM | | | SPECIFICATIONS AND GUIDELINES- 305.1, 503.3, 503.3.1 & | | | 623.1. | | | B) PROVIDE EXHAUST/VENT DUCTS SIZING CALCULATIONS AND | | | SUBMIT MANUFACTURER'S SPECIFICATIONS AND INSTALLATION | | | GUIDELINES FOR THE VENT SYSTEM. | | | C) PROVIDE A DIMENSIONED EXHAUST/VENT DIAGRAM SHOWING | | | CONNECTOR AND TOTAL RUN LENGTH OF THE SYSTEM CONSISTENT | | | WITH THE MANUFACTURER'S SPECIFICATIONS AND/OR | | | ENGINEERED CALCULATIONS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | CCOLE@WPB | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-08-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-08-26 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-08-26 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2021-08-26 15:08:20 | 2ND REVIEW FBC-2020 FUEL GAS | | | PERMIT- 21050671 | | | 8/26/21 | | | | | | CODES IN EFFECT: | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | | 1ST REVIEW LISTED BELOW WITH ADDITIONAL NOTES IN CAPS. | | | | | | 2) FAILED. 3.0P & 3.1P: SUBMIT MANUFACTURER'S | | | SPECIFICATIONS FOR THE NEW COFFEE ROASTER- SECTION | | | 305.1 FBC FG. PLEASE HIGHLIGHT OR MARKUP THE SPEC TO | | | SHOW THE LISTING STANDARD, BTU LOAD, AND GAS INPUT | | | PRESSURE. THE SUBMITTED ROASTER SPECS DO NOT SHOW THE | | | LISTING STANDARD, GAS INPUT PRESSURE, OR CATEGORY OF | | | THE CATEGORY OF THE APPLIANCE. PLEASE REFER TO SECTIONS | | | 305.1 AND 623.1 FBC FG FOR LISTING REQUIREMENTS, AND | | | SECTION 410.2- INPUT PRESSURE IS REQUIRED FOR | | | DETERMINING THE REQUIRED SUPPLY PIPE PRESSURE AND | | | REGULATOR SELECTION. ALSO MISSING WITH THE SUBMITTAL | | | ARE MANUFACTURER?S INSTALLATION GUIDELINES FOR | | | SUPPLYING COMBUSTION AIR, MAKEUP AIR, AND PROPER | | | VENTING OF THE EQUIPMENT. PLEASE NOTE THE ROASTER SPECS | | | INDICATE A BTUH LOAD OF 144,000 NOT 140,000 AS | | | INDICATED ON THE RISER. THE CATEGORY OF THE APPLIANCE | | | NEEDS TO BE ESTABLISHED IN ORDER FOR A COMPLETE REVIEW | | | OF THE EXHAUST/VENT SYSTEM. PLEASE INDICATE CATEGORY I, | | | II, III, OR IV PER SECTIONS 202, 503.6.9.1, & & | | | 503.6.9.3. FBC FG. | | | | | | 3) FAILED. 3.0P & 3.1P: PROVIDE COMBUSTION AIR | | | CALCULATIONS FOR THE COFFEE ROASTER AND INDICATE HOW | | | THE AIR IS BEING SUPPLIED- SECTION 304.1 FBC FG. THE | | | RESPONSE NARRATIVE INDICATES INDOOR COMBUSTION AIR IS | | | TO BE USED, HOWEVER THE PLAN SHOWS A CALCULATION FOR | | | MECHANICALLY SUPPLIED AIR PER 304.9 USING AN OPENING TO | | | THE OUTDOORS: A) MECHANICAL AIR MUST BE SUPPLIED BY AN | | | AIR SUPPLY SYSTEM- MEANING CONDUCTED FROM A SUPPLY | | | UNIT. COMBUSTION AIR THROUGH ONE WALL OPENING SHALL | | | COMPLY WITH 304.6.2- 1 SQ. INCH PER 3000 BTUH. SEE | | | COMMENT #3 FOR COMBUSTION AIR/VENTING COMPLIANCES. | | | | | | 4) FAILED. 3.0P & 3.1P: PROVIDE GAS VENTING PLANS FOR | | | THE ROASTER- SECTIONS 305.1, 502.1, 502.5, AND 503.1-. | | | THE DRAWING SPEARS TO INDICATE TWO VENT DUCTS FOR THE | | | ROASTER THAT ARE PENETRATING THROUGH THE WALL AND | | | TURNING UPWARD. PLEASE PROVIDE A DIAGRAM AND ELEVATION | | | VIEW SHOWING THE TYPES AND SIZES OF VENT FLUES OR | | | DUCTS, HORIZONTAL CONNECTORS, VERTICAL FLUES, AND | | | TERMINATION CAPS. PLEASE PROVIDE THE VENT TERMINATION | | | CLEARANCE DISTANCES TO DOOR AND WINDOW OPENINGS INTO | | | THE BUILDING- SECTIONS 305.1, 403.4, 503.6 & 503.8 FBC | | | FG. RTHE TYPE AND SIZE OF EXHAUST/VENTING SYSTEM IS | | | DEPENDENT ON THE CATEGORY OF THE APPLIANCE. PLEASE | | | INDICATE CATEGORY I, II, III, OR IV PER SECTIONS 202, | | | 503.6.9.1 & 503.6.9.3.FBC FG. THE CURRENT | | | EXHAUST/VENTING PLAN ON SHEET 4.1M IS INCOMPLETE AND | | | SHOWS ONLY ONE THE TWO DUCT SYSTEMS. | | | A) CLARIFY HOW THE SYSTEM WAS DESIGNED- SUBMIT COFFEE | | | ROASTERS VENTING/MAKEUP-COMBUSTION AIR SYSTEM | | | SPECIFICATIONS AND GUIDELINES- 305.1, 503.3, 503.3.1 & | | | 623.1. | | | | | | B) PROVIDE EXHAUST/VENT DUCTS SIZING CALCULATIONS AND | | | SUBMIT MANUFACTURER'S SPECIFICATIONS AND INSTALLATION | | | GUIDELINES FOR THE SINGLE-WALL ZERO CLEARANCE DUCT- | | | 305.1, 503.3, 503.3.1.503.7.9. | | | | | | C) PROVIDE A DIMENSIONED EXHAUST/VENT DIAGRAM SHOWING | | | CONNECTOR AND TOTAL RUN LENGTH OF THE SYSTEM CONSISTENT | | | WITH THE MANUFACTURER'S SPECIFICATIONS AND/OR | | | ENGINEERED CALCULATIONS. | | | | | | D) PLEASE NOTE THE FOLLOWING LIMITATIONS OF USE FOR | | | SINGLE WALL DUCT- | | | | | | SECTION 503.7.3: SINGLE WALL PIPE SHALL EXTEND NOT LESS | | | THAN 2 FT. HIGHER THAN ANY PORTION OF A BUILDING WITHIN | | | A HORIZONTAL DISTANCE OF 10 FT. THE DRAWNIG IS | | | NON-COMPLIANT. | | | | | | 503.7.4: SINGLE-WALL METAL DUCT SHALL BE USED ONLY FOR | | | RUNS DIRECTLY FROM THE SPACE IN WHICH THE APPLIANCE IS | | | LOCATED THROUGH THE ROOF OR EXTERIOR WALL TO THE | | | OUTDOOR ATMOSPHERE. DRAWING IS NON-COMPLIANT. | | | | | | 503.7.5: A PIPE PASSING THROUGH A ROOF SHALL EXTEND | | | WITHOUT INTERRUPTION THROUGH THE ROOF FLASHING, ROOF | | | JACK OR ROOF THIMBLE. WHERE A SINGLE-WALL METAL PIPE | | | PASSES THROUGH A ROOF CONSTRUCTED OF COMBUSTIBLE | | | MATERIAL, A NONCOMBUSTIBLE, NONVENTILATING THIMBLE | | | SHALL BE USED AT THE POINT OF PASSAGE. THE THIMBLE | | | SHALL EXTEND NOT LESS THAN 18 INCHES (457 MM) ABOVE AND | | | 6 INCHES (152 MM) BELOW THE ROOF WITH THE ANNULAR SPACE | | | OPEN AT THE BOTTOM AND CLOSED ONLY AT THE TOP. THE | | | THIMBLE SHALL BE SIZED IN ACCORDANCE WITH SECTION | | | 503.7.7. DRAWING IS NON-COMPLIANT. | | | | | | 503.7.6: SINGLE-WALL METAL PIPE SHALL NOT ORIGINATE IN | | | ANY UNOCCUPIED ATTIC OR CONCEALED SPACE AND SHALL NOT | | | PASS THROUGH ANY ATTIC, INSIDE WALL, CONCEALED SPACE OR | | | FLOOR. THE INSTALLATION OF A SINGLE-WALL METAL PIPE | | | THROUGH AN EXTERIOR COMBUSTIBLE WALL SHALL COMPLY WITH | | | SECTION 503.7.7. DRAWING IS NON-COMPLIANT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-06-29 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-06-29 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2021-06-29 12:44:41 | 1ST REVIEW FBC-2020 FUEL GAS | | | PERMIT- 21050671 | | | 6/29/21 | | | | | | CODES IN EFFECT: | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 3.1P: PROVIDE A COMPLETE GAS RISER DRAWING | | | THAT INCLUDES ALL NEW AND EXISTING GAS PIPING AND | | | APPLIANCES BEING SUPPLIED BY THE METER- SECTION 401.4 | | | FBC FG. THE DRAWING SHOWS A 2 INCH BRANCH LINE | | | SUPPLYING 879 MBTUH. REFER TO SECTION 402 AND PROVIDE: | | | A) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. | | | B) TYPES AND SIZES OF PIPING. | | | C) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER | | | TO THE MOST REMOTE APPLIANCE OUTLET. | | | D) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. | | | E) LOCATIONS OF REGULATORS, SHUTOFF VALVES, DRIPLEGS, | | | AND PIPE UNIONS. | | | F) OUTLET PRESSURES AT REGULATORS. | | | G) LOCATIONS AND TYPES OF PIPE SLEEVES. | | | H) LIST PIPE SIZING TABLES. | | | | | | 2) 3.0P & 3.1P: SUBMIT MANUFACTURER?S SPECIFICATIONS | | | FOR THE NEW COFFEE ROASTER- SECTION 305.1 FBC FG. | | | PLEASE HIGHLIGHT OR MARKUP THE SPEC TO SHOW THE LISTING | | | STANDARD, BTU LOAD, AND GAS INPUT PRESSURE. | | | | | | 3) 3.0P & 3.1P: PROVIDE COMBUSTION AIR CALCULATIONS FOR | | | THE COFFEE ROASTER AND INDICATE HOW THE AIR IS BEING | | | SUPPLIED- SECTION 304.1 FBC FG. | | | | | | 4) 3.0P & 3.1P: PROVIDE GAS VENTING PLANS FOR THE | | | ROASTER- SECTIONS 305.1, 502.1, 502.5, AND 503.1-. THE | | | DRAWING SPEARS TO INDICATE TWO VENT DUCTS FOR THE | | | ROASTER THAT ARE PENETRATING THROUGH THE WALL AND | | | TURNING UPWARD. PLEASE PROVIDE A DIAGRAM AND ELEVATION | | | VIEW SHOWING THE TYPES AND SIZES OF VENT FLUES OR | | | DUCTS, HORIZONTAL CONNECTORS, VERTICAL FLUES, AND | | | TERMINATION CAPS. PLEASE PROVIDE THE VENT TERMINATION | | | CLEARANCE DISTANCES TO DOOR AND WINDOW OPENINGS INTO | | | THE BUILDING- SECTIONS 305.1, 403.4, 503.6 & 503.8 FBC | | | FG. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-10-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-09-30 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-08-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-08-09 |
Time |
08:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-07-27 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-05-27 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-12 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-12 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2021-10-12 10:50:46 | APPROVED WITH NOTES. | | | | | | SHEET 4.0M:THIS APPEARS TO BE MISLABELED. THERE SHOULD | | | NOT BE A FIRE DAMOER IN THE ROASTER EXHAUST DUCT. | | | INSPECTOR TO CHECK IN THE FIELD. | | | SHEET 4.1M: COOLING FAN DETAILS CALLS FOR A 6 INCH | | | SINGLE WALL COOLING DUCT. INSPECTOR TO VERIFY IN FIELD. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-08-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-25 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-25 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2021-08-25 12:47:58 | 2ND REVIEW FBC-2020 MECHANICAL | | | PERMIT-21050671 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE ATTACHED SPECIFICATIONS DO NOT SHOW THE EXHAUST | | | PIPING DETAILS. PLEASE PROVIDE DETAILS FOR THE EXHAUST | | | SYSTEM OF THIS ROASTER, TYPE OF PIPE, SIZE OF PIPE, | | | LENGTH OF PIPE. INFORMATION FROM THE MANUFACTURER | | | REFERENCING THE EXHAUST PIPING USED. FBC 107.2.1 | | | | | | 2) SHEET 4.1M: PLEASE PROVIDE THE USE OF SPACE BASED ON | | | FBC M TABLE 403.3.1.1 FOR THE OUTDOOR AIR CALCULATIONS. | | | ARE YOU USING KITCHEN FOR THE PREP AREA AND DINING FOR | | | THE CUSTOMER AREA? ACCORDING TO FBC M 403.3.1.1 WE MUST | | | US THE TABLE FOR CALCULATING THE NUMBER OF PEOPLE IN | | | EACH SPACE NOT THE ARCHITECT?S OCCUPANT LOAD. PLEASE | | | KEEP IN MIND FOOTNOTE (A) ALLOWS US TO USE THE NET AREA | | | AND NOT THE GROSS FLOOR AREA. | | | | | | 3) PLEASE SHOW HOW YOU WILL BE BRINGING IN THE MAKEUP | | | AIR FOR THE EXHAUST FAN ON THE ROASTER ( 1125 CFM?S). | | | FBC FG 304.9.1 | | | | | | 4) THE ROASTER VENTILATION DETAIL SUBMITTED ON SHEET | | | 4.1M DOES NOT DEPICT THE BUILDING WHERE THIS TENANT | | | SPACE IS LOCATED. THIS IS A 3 STORY WITH RETAIL ON THE | | | FIRST FLOOR BUT RESIDENTIAL ON THE 2ND AND 3RD FLOORS. | | | THIS DRAWING SHOWS ?ZERO CLEARANCE PIPE THRU WALL BOXED | | | OUT TO ROOF? BUT DOES NOT SHOW BOTH FLOORS ABOVE NOR | | | DOES IT HAVE A NOTE DESCRIBING THIS SITUATION. THIS | | | DRAWING ALSO SHOWS A FD IN THE ROASTER EXHAUST PIPE | | | ABOVE THE FLOOR IN WHAT APPEARS TO BE A BOX. PLEASE | | | SHOW THE MANUFACTURER?S INSTALLATION INSTRUCTIONS FOR | | | THIS TYPE OF PIPING METHOD. | | | | | | 5) SHEET 4.1M: THE ROASTER VENTILATION DETAIL DOES NOT | | | SHOW THE EXHAUST FOR THE COOLING TUB. | | | | | | | | | 6) PLEASE PROVIDE THE LISTING FOR THIS APPLIANCE. FBC M | | | 301.7 | | | | | | 7) PLEASE EXPLAIN YOUR ANSWER TO MY 1ST CYCLE COMMENT | | | NUMBER (5): PLEASE SHOW THE OUTDOOR AIR DUCT FOR BOTH | | | AHU-1 UNITS. YOUR ANSWER WAS ?BOTH AIR HANDLERS UNITS | | | HAVE OUTSIDE AIR DUCT WORK TO THE KNOCK OUT PROVIDED | | | WITH BUILDING? PLEASE SHOW THE OUTDOOR AIR DUCT WORK | | | AND SIZE ON THE DRAWING. FBC 107.2.1 | | | | | | 8) 1ST CYCLE REVIEW COMMENT NUMBER (6) AHU-2 FOR THE | | | KITCHEN AREA: CFM?S ON SHEET 4.0M SHOWS A TOTAL OF 2200 | | | CFM?S OF SUPPLY AIR BEING SUPPLIED INTO THE KITCHEN | | | AREA. SHEET 4.1M INDICATES THE MAX. CFM OF SUPPLY FOR | | | THIS UNIT IS 2000 CFM?S. PLEASE BE CONSISTENT. FBC | | | 107.2.1 | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-22 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-22 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2021-06-22 14:47:38 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21050671 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE OUTDOOR AIR CALCULATIONS FOR EACH USE | | | OF SPACE ACCORDING TO FBC M 403.3.1.1 AND TABLE | | | 403.3.1.1. | | | | | | 2) PLEASE PROVIDE THE SPECIFICATIONS FOR THE ROASTING | | | EQUIPMENT AND THE VENTING OF THIS EQUIPMENT. FBC | | | 107.2.1 | | | | | | 3) PLEASE SHOW THE CONDENSATE PIPING MATERIAL AND | | | SIZING ALONG WITH THE TERMINATION LOCATION. THE | | | CONDENSATE IS REQUIRED TO GO TO STORM OR AN APPROVED | | | OUTDOOR LOCATION. FBC M 307 | | | | | | 4) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS FOR THIS TENANT SPACE. | | | | | | 5) PLEASE SHOW THE OUTDOOR AIR DUCT FOR BOTH AHU-1 | | | UNITS. FBC 107.2.1 | | | | | | 6) THE KITCHEN AHU-1 IS SUPPLY 2400 CFM?S OF AIR BUT | | | THE SPECS SHOW IT CAN ONLY SUPPLY 2000 CFM. PLEASE | | | CORRECT THIS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-22 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-22 |
Time |
08:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-19 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-18 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2021-10-19 11:23:15 | 3RD REVIEW FBC-2020 PLUMBING | | | PERMIT- 21050671 | | | 6/29/21 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS 3.0P & 3.1P: 3RD REQUEST- A MASTER | | | THERMOSTATIC MIXING VALVE IS SPECIFIED TO PROVIDE | | | TEMPERED WATER AT 108 DEGREES F TO ALL FIXTURES EXCEPT | | | THE MOP SINK AND 3-COMPARTMENT, HOWEVER THE PLAN AND | | | WATER RISER EACH SHOW HOT WATER LINES AT 140 AND 110 | | | DEGREES F BEING. PLEASE SEE SECTION 202 FOR DEFINITIONS | | | OF HOT AND TEMPERED WATER AND CORRECT THE PLAN. PLEASE | | | NOTE THAT THE TEMPERED WATER IS ONLY REQUIRED FOR THE | | | LAVATORIES REQUIRED FOR THE LAVATORIES- SECTION 419.5 | | | FBC P. THE DESIGNER HAS THE OPTION OF USING POINT OF | | | USE MIXING VALVES OR SUPPLY COLD WATER ONLY. | | | | | | 2) 3.0P: 3RD REQUEST TO SHOW THE HOT WATER RETURN LINE | | | CONNECTING TO THE MIXING VALVE AND TO THE COLD WATER | | | INLET PIPE TO THE WATER HEATER- SECTION 607.2.2. FBC P. | | | | | | 3) 3.1P: 2ND REQUEST TO CORRECT THE SANITARY RISER | | | DRAWING SHOWING THE EXISTING 4-INCH SANITARY DRAIN | | | CONNECTING TO THE NEW GREASE WASTE LINE- SECTION | | | 107.2.1 WPB AND 1003.3.1 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-08-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-08-26 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-08-26 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2021-08-26 15:14:48 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21050671 | | | 6/29/21 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | FAILED COMMENTS FROM THE 1ST REVIEW ARE LISTED BELOW | | | WITH ADDITIONAL NOTED IN CAP LETTERS. | | | | | | 10) FAILED. 3.1P: ONE HAND SINK LABEL IS MISSING IN THE | | | WATER RISER- SECTION 107.2.1 WPB. PROVIDE THE MISSING | | | HS LABEL. | | | | | | 11) FAILED. 3.1P WATER RISER: PLEASE PROVIDE A | | | DIFFERENT LINE SYMBOL FOR THE HOT WATER RETURN LINE. | | | THE SAME HOT WATER SYMBOL IS BEING USED TO DESIGNATE HW | | | AT 110 DEGREES, HW AT 140 DEGREES, AND HW RETURN. REFER | | | TO THE MASTER MIXING VALVE DETAIL ON SHEET 3.0P: THE | | | DETAIL SHOWS INLETS FOR 140 DEGREE HW AND CW, AND ONE | | | OUTLET FOR 110 DEGREE TEMPERED. NEITHER THE WATER RISER | | | NOR THE ENLARGED WATER HEATER PIPING DETAIL MATCH WITH | | | THE VALVE DETAIL. PLEASE REFER TO SECTION 607.2.2 FBC P | | | AND REVISE THE DRAWINGS- WHERE A THERMOSTATIC MIXING | | | VALVE IS USED IN A SYSTEM WITH A HOT WATER | | | RECIRCULATING PUMP, THE HOT WATER OR TEMPERED WATER | | | RETURN LINE SHALL BE ROUTED TO THE COLD WATER INLET | | | PIPE OF THE WATER HEATER AND THE COLD WATER INLET PIPE | | | OR THE HOT WATER RETURN CONNECTION OF THE THERMOSTATIC | | | MIXING VALVE. A) PLRASE LABEL THE MIXING VALVE ON THE | | | RISER DRAING. THE REQUESTED LINE SYMBOL CHANGEES WERE | | | NOT PROVIDED. | | | | | | 14) FAILED. 3.1P: PROVIDE A PLUMBING FIXTURE SCHEDULE | | | LISTING MAKES AND MODELS BATHROOM FIXTURES, MOP SINK, | | | 3-COMPARTMENT SINK, HAND SINKS, DUMP SINK, FLOOR SINKS, | | | FLOOR DRAIN, AND WATER FILTER SYSTEM- SECTIONS | | | 107.3.5.1.3 & 107.2.1 WPB. THE MOP SINK, 3-COMPARTMENT | | | SINK, HAND SINKS, DUMP SINK, FLOOR SINKS, FLOOR DRAIN, | | | AND WATER FILTER SYSTEM WERE NOT INCLUDED IN THE | | | FIXTURE SCHEDULE HOWEVER THESE ITEMS MAY BE DEFERRED IF | | | NECESSARY. PLEASE PROVIDE A LIST OF ALL REQUESTED | | | DEFERRED SUBMITTALS ON THE PLAN- SECTION 107.3.4.1 WPB. | | | | | | 15) FAILED. 3.1P: PROVIDE A DEVICE SCHEDULE LISTING | | | MAKES AND MODELS OF WATER HAMMER ARRESTORS, MIXING | | | VALVES, RECIRCULATION PUMP, AND BACKFLOW PREVENTERS- | | | SECTIONS 107.3.5.1.3 & 107.2.1 WPB. A DEVICE SCHEDULE | | | WAS NOT PROVIDED HOWEVER THE WATER HAMMER ARRESTORS, | | | MIXING VALVES, AND BACKFLOW PREVENTERS MAY BE DEFERRED | | | SUBMITTALS IF NECESSARY. PLEASE PROVIDE A LIST OF ALL | | | REQUESTED DEFERRED SUBMITTALS ON THE PLAN- SECTION | | | 107.3.4.1 WPB. | | | | | | 17) FAILED. 3.1P GREASE INTERCEPTOR: PLEASE NOTE A | | | SEPARATE PERMIT IS REQUIRED FOR INSTALLATION OF THE | | | INTERCEPTOR AND A COMPLETE PLANS AND SPECIFICATIONS | | | SHALL BE SUBMITTED INCLUDING A CIVIL PLAN- SECTION | | | 107.2.1 WPB. FOR THE PURPOSES OF THIS PERMIT PLEASE | | | SHOW REQUIRED CLEANOUTS AT THE INLET AND OUTLET OF THE | | | INTERCEPTOR AND THE LOCATION OF THE SAMPLING PORT. | | | PROVIDE A DETAIL FOR INSTALLATION OF THE PORT PER | | | MANUFACTURER?S SPECIFICATIONS- SECTION 1003.3.3 FBC P. | | | THE GREASE INTERCEPTOR IS INDICATED TO BE A SCHIER GB50 | | | ON SHEET 3.0P, AND A GBHF-250-250 ON SHEET 3.1P. | | | | | | A) FAILED. 3.1P: PROVIDE SIZING CALCULATIONS FOR THE | | | INTERCEPTOR IN ACCORDANCE WITH ASME A112.14.3, ASME | | | A112.14.4, ASME A112.14.6, CSA B481.3 OR PDI G101- | | | SECTION 1003.3.3 FBC P. THE CALCULATIONS ON SHEET 3,0P | | | DO NOT INCLUDE THE DUMP SINK. | | | | | | NEW COMMENTS. | | | | | | 1) 3.0P & 3.1P: THE 4-INCH EXISTING SANITARY IS SHOWN | | | CONNECTING TO THE GREASE WASTE LINE IN THE SANITARY | | | RISER DRAWING- SECTION 107.2.1 WPB. | | | | | | 2) 3.0: THE LOCATION OF THE CLEANOUT AT THE JUNCTION OF | | | THE SANITARY AND SEWER DRAIN NOT PROVIDED. | | | | | | 3) 3.0P & 3.1P: CORRECT THE SUPPLY PIPING LAYOUT TO THE | | | URINAL AND LAVATORY ON 3.0P- 107.2.1 WPB. | | | | | | 4) 3.0P & 3.1P: THE PLAN IS NOT SHOWING HOW TEMPERED | | | WATER WILL BE PROVIDED TO THE LAVATORIES AS REQUIRED BY | | | SECTION 419.5 FBC P. PLEASE NOTE THE MASTER MIXING | | | VALVE IS SUPPLYING HOT WATER AT 110 DEGREES F. TEMPERED | | | WATER IS DEFINED AS WATER HAVING A TEMPERATURE RANGE | | | BETWEEN 85 DEGREES AND 110 DEGREES F. | | | | | | 5) 1.1A, 3.0P & 3.1P: THE WATER FILTERING SYSTEM IS NOT | | | INCLUDED IN THE EQUIPMENT SCHEDULE, AND THE WATER RISER | | | IS NOT SHOWING ALL THE FILTERED WATER SUPPLY LINES TO | | | THE EQUIPMENT IN THE SCHEDULE. PLEASE MODIFY THE RISER | | | OR PROVIDE A SEPARATE FILTERED WATER SYSTEM RISER- | | | SECTION 107.2.1. PLEASE NOTE THAT INDIVIDUAL BACKFLOW | | | PREVENTERS ARE REQUIRED ON EACH SUPPLY LINE TO THE | | | COFFEE EQUIPMENT. | | | | | | 6) 3.0P & 3.1P: IT IS ACKNOWLEDGED THAT THE GREASE | | | INTERCEPTOR WILL BE UNDER SEPARATE PERMIT, HOWEVER MORE | | | INFORMATION UNDER THE MAIN PERMIT IS REQUIRED INCLUDING | | | THE JUNCTION LOCATIONS OF THE EXISTING SANITARY, GREASE | | | WASTE OUTLET PIPE, AND EXISTING SEWER LINE. PLEASE ALSO | | | SHOW THE LOCATION OF THE INTERCEPTOR SAMPLING PORT AND | | | CLARIFY IF THE INTERCEPTOR IS LOCATED IN A DRIVE OR | | | LANDSCAPED AREA. PLEASE NOTE THAT HEAVY DUTY TRAFFIC | | | LIDS AT ACCESS COVERS ARE REQUIRED FOR INTERCEPTORS IN | | | DRIVE AREAS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-06-29 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-06-29 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2021-06-29 12:00:27 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21050671 | | | 6/29/21 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET C1: THE PLUMBING FIXTURE CALCULATIONS BASED ON | | | 72 OCCUPANTS DOES NOT MATCH THE 129 NUMBER OF SEATS | | | SHOWN. PLEASE CORRECT- TABLE 403.1 FBC P. | | | | | | 2) 1.0A & 1.4A: PLEASE PROVIDE ENLARGED MEN'S AND | | | WOMEN'S TOILET ROOM ENLARGED DIMENSIONED DRAWINGS ON | | | 1.4A THAT MATCH THE FLOOR PLAN DRAWINGS ON 1.0A. THE | | | FLOOR PLAN SHOWS DOORS SWINGING IN TO THE TOILET ROOMS | | | WHICH IS NOT ALLOWED PER SECTION 603.2.3 FBC ACC. THE | | | FLOOR PLAN ALSO DOES NOT PROVIDE A WIDTH MEASUREMENT | | | FOR THE WOMEN'S TOILET ROOM- SECTION 107.2.1 WPB. | | | | | | 3) 1.4A: LOCATION OF THE TOILET PAPER DISPENSER IS NOT | | | SHOWN TO BE IN COMPLIANCE WITH SECTION 604.7 FBC ACC. | | | | | | 4) 1.4A: PROVIDE AN ELEVATION VIEW OF THE CONDIMENTS | | | COUNTER TO VERIFY ACCESSIBILITY COMPLIANCES- SECTIONS- | | | 904.5 & 308 FBC ACC. | | | | | | 5) 1.1A, 3.0P, & 3.1P: THE HAND SINKS- #10, #28, AND | | | THE FLOOR SINK BY THE ICE MAKER AND BIN SHALL NOT DRAIN | | | IN TO THE GREASE WASTE LINE AND INTERCEPTOR- SECTION | | | 1003.3.1 FBC P. THE FIXTURES ARE NOT CONSIDERED TO BE | | | SIGNIFICANT GREASE CONTRIBUTORS. | | | | | | 6) 1.1A, 3.0P, & 3.1P: THE DUMP SINK #21 REQUIRES AN | | | INDIRECT WASTE- SECTION 802.1 FBC P. | | | | | | 7) 1.1A, 3.0P, & 3.1P: HAND SINK #28 APPEARS TO MISSING | | | FROM THE ISOMETRIC DRAWINGS. | | | | | | 8) 3.0P: PROVIDE AN EQUIPMENT SCHEDULE FOR THE WATER | | | HEATER MAKE AND MODEL AND EFFICIENCY RATING- SECTION | | | 502.1 FBC P. SHOW THE PAN DRAIN AND PAN DRAIN LINE RUN | | | AND TERMINATION LOCATION- SECTIONS 504.6- 504.7.2 FBC | | | P. | | | | | | 9) 3.0P: THE SERVICE ACCESS TO THE WATER HEATER APPEARS | | | TO BE BLOCKED BY THE ADJACENT SINKS- SECTION 501.4 FBC | | | P. | | | | | | 10) 3.1P: ONE HAND SINK LABEL IS MISSING IN THE WATER | | | RISER- SECTION 107.2.1 WPB. | | | | | | 11) 3.1P WATER RISER: PLEASE PROVIDE A DIFFERENT LINE | | | SYMBOL FOR THE HOT WATER RETURN LINE. THE SAME HOT | | | WATER SYMBOL IS BEING USED TO DESIGNATE HW AT 110 | | | DEGREES, HW AT 140 DEGREES, AND HW RETURN. IT ALSO | | | APPEARS THAT NO COLD WATER IS BEING SUPPLIED TO THE | | | LAVATORY SINKS. | | | | | | 12) 3.1P: ONE LAVATORY IS NOT LABELED IN THE SANITARY- | | | SECTION 107.2.1 WPB. | | | | | | 13) THE URINAL IS NOT INCLUDED IN THE DEFINITION OF A | | | BATHROOM GROUP SO THE FIXTURE DRAIN FROM THE URINAL | | | SHALL NOT CONNECT INTO THE HORIZONTAL WET VENT- | | | SECTIONS 202 AND 912.1 FBC P. THE FIXTURE MUST BE | | | INDIVIDUALLY VENTED AND CONNECTION OF THE DRAIN SHALL | | | BE DOWNSTREAM OF THE WET VENT. | | | 14) 3.1P: PROVIDE A PLUMBING FIXTURE SCHEDULE LISTING | | | MAKES AND MODELS BATHROOM FIXTURES, MOP SINK, | | | 3-COMPARTMENT SINK, HAND SINKS, DUMP SINK, FLOOR SINKS, | | | FLOOR DRAIN WATER FILTER SYSTEM- SECTIONS 107.3.5.1.3 & | | | 107.2.1 WPB. | | | | | | 15) 3.1P: PROVIDE A DEVICE SCHEDULE LISTING MAKES AND | | | MODELS OF WATER HAMMER ARRESTORS, MIXING VALVES, | | | RECIRCULATION PUMP, AND BACKFLOW PREVENTERS- SECTIONS | | | 107.3.5.1.3 & 107.2.1 WPB. | | | | | | 16) 3.1P: PROVIDE CLEANOUT AT THE JUNCTION OF THE | | | SANITARY BUILDING DRAIN AND SEWER LINE- SECTION 708.1.3 | | | FBC P. | | | | | | 17) 3.1P GREASE INTERCEPTOR: PLEASE NOTE A SEPARATE | | | PERMIT IS REQUIRED FOR INSTALLATION OF THE INTERCEPTOR | | | AND A COMPLETE PLANS AND SPECIFICATIONS SHALL BE | | | SUBMITTED INCLUDING A CIVIL PLAN- SECTION 107.2.1 WPB. | | | FOR THE PURPOSES OF THIS PERMIT PLEASE SHOW REQUIRED | | | CLEANOUTS AT THE INLET AND OUTLET OF THE INTERCEPTOR | | | AND THE LOCATION OF THE SAMPLING PORT. PROVIDE A DETAIL | | | FOR INSTALLATION OF THE PORT PER MANUFACTURER?S | | | SPECIFICATIONS- SECTION 1003.3.3 FBC P. | | | | | | A) 3.1P: PROVIDE SIZING CALCULATIONS FOR THE | | | INTERCEPTOR IN ACCORDANCE WITH ASME A112.14.3, ASME | | | A112.14.4, ASME A112.14.6, CSA B481.3 OR PDI G101- | | | SECTION 1003.3.3 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-22 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-22 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2021-10-22 09:05:47 | SEPARATE PERMIT REQUIRED FOR GREASE INTERCEPTOR | | | INSTALLATION. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-10-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-22 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-22 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-10-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-19 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-18 |
Time |
12:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-08-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-08-24 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-08-24 |
Time |
16:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-06-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-22 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-22 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-08-18 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-08-18 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-08-18 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2021-08-18 09:51:37 | THIS REVIEW IS LIMITED TO THE INTERIOR BUILD-OUT ONLY. | | | | | | THE CASA MARA COMMERCIAL PLANNED DEVELOPMENT SHALL BE | | | SUBJECT TO ALL DEVELOPMENT ORDER CONDITIONS, AS | | | OUTLINED IN RESOLUTION NO. 108-21, APPROVED ON JUNE 1, | | | 2021, AND AS MAY BE AMENDED. | | | | | | PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, | | | THE DEVELOPER SHALL DESIGNATE AT LEAST 71 ON-SITE | | | PARKING SPACES (OUTSIDE OF THE SECURITY GATE-CONTROLLED | | | PARKING FIELDS) TO BE RESERVED FOR USE BY PATRONS AND | | | EMPLOYEES OF THE NON-RESIDENTIAL USES. THE SPACES SHALL | | | BE RESERVED FOR SUCH USE BETWEEN THE HOURS OF 11:00 AM | | | AND 7:00 PM. OUTSIDE OF THOSE HOURS, THESE 71 PARKING | | | SPACES WILL BE AVAILABLE FOR USE BY THE NON-RESIDENTIAL | | | PATRONS/EMPLOYEES AS WELL AS RESIDENTS. SIGNAGE AND/OR | | | MARKING TO DESIGNATE THESE SPACES WILL BE DETERMINED | | | AND IMPLEMENTED BY THE OWNER, SUBJECT TO REVIEW AND | | | APPROVAL BY THE CITY?S PLANNING DIVISION. THE HOURS AND | | | NUMBER OF SPACES DESIGNATED MAY BE ADJUSTED THROUGH AN | | | ADMINISTRATIVE APPROVAL BY CITY?S PLANNING DIVISION IF | | | THE USE AND/OR OPERATING HOURS OF COMMERCIAL TENANTS | | | SIGNIFICANTLY CHANGES IN THE FUTURE. | | | | | | _______________________________________________________ | | | _____________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | P: 561.822.1448 | E: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-08-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-08-11 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-08-11 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2021-08-11 09:34:40 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 08.11.2021 | | | PERMIT NO.: 21050671 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. [ SATISFIED ] - PLEASE PROVIDE A SITE PLAN OR | | | SIMILAR SHOWING WHICH BUILDING AND WHICH SPACE THIS | | | IMPROVEMENT PERTAINS TO. THERE IS NO CONTEXT ON THE | | | FLOOR PLAN FOR ME TO KNOW WHERE THIS IMPROVEMENTS ARE | | | TAKING PLACE. | | | | | | 2. [ SATISFIED ] - WHAT IS HAPPENING TO THE EXTERIOR | | | DOOR ON THE NORTH SIDE OF THE BUILDING, CLOSEST TO | | | SOUTH DIXIE HIGHWAY? THERE IS A SYMBOL WITH THE #1 | | | THERE, BUT NO LEGEND OR KEY FOR ME TO KNOW WHAT IS | | | PROPOSED. | | | | | | 3. [ SATISIFED ] - WHAT IS HAPPENING TO THE | | | EASTERN-MOST DOOR THAT CONNECTS TO THE CORRIDOR IN THE | | | MIDDLE OF THE BUILDING? | | | | | | 4. [ SATISFIED ] - ON SHEET 1.1A, WHAT ARE THE TWO AREA | | | OUTLINED WITH A DASHED LINE AND CONTAINING A SQUARE | | | FOOTAGE CALCULATION? | | | | | | 5. [ SATISFIED ] - THE OUTDOOR SEATING SHOWN ON THE | | | PLAN DOES NOT MATCH THAT WHICH WAS APPROVED ON THE CASA | | | MARA CPD SITE PLAN. THE AREAS SHALL MATCH, OR IF THE | | | AREA IS PROPOSED TO BE MODIFIED, AN AMENDMENT TO THE | | | CPD SHALL BE SUBMITTED TO AND APPROVED BY THE PLANNING | | | DIVISION. | | | | | | 6. [ SATISFIED ] - THE OUTDOOR SEATING SHOWN ON THE | | | PLAN CONFLICTS WITH THE ACCESSIBLE ROUTE FROM THE | | | ADJACENT ACCESSIBLE PARKING SPACES. | | | | | | 7. [ NOT SATISFIED ] - THE PLANS DO NOT ACCURATELY | | | REFLECT THE SIDEWALK, LANDSCAPING ISLANDS, PARKING, | | | ETC. ON THE EAST SIDE OF THE BUILDING (ALONG SOUTH | | | DIXIE HIGHWAY). | | | | | | 8. [ SATISIFED - SUBJECT TO PROVISO ] - PURSUANT TO | | | RESOLUTION NO. 108-21, THE DEVELOPER SHALL DESIGNATE AT | | | LEAST 71 ON-SITE PARKING SPACES (OUTSIDE OF THE | | | SECURITY GATE-CONTROLLED PARKING FIELDS) TO BE RESERVED | | | FOR USE BY PATRONS AND EMPLOYEES OF THE NON-RESIDENTIAL | | | USES. THE SPACES SHALL BE RESERVED FOR SUCH USE BETWEEN | | | THE HOURS OF 11:00 AM AND 7:00 PM. OUTSIDE OF THOSE | | | HOURS, THESE 71 PARKING SPACES WILL BE AVAILABLE FOR | | | USE BY THE NON-RESIDENTIAL PATRONS/EMPLOYEES AS WELL AS | | | RESIDENTS. | | | | | | SIGNAGE AND/OR MARKING TO DESIGNATE THESE SPACES WILL | | | BE DETERMINED AND IMPLEMENTED BY THE OWNER, SUBJECT TO | | | REVIEW AND APPROVAL BY THE CITY?S PLANNING DIVISION. | | | THE HOURS AND NUMBER OF SPACES DESIGNATED MAY BE | | | ADJUSTED THROUGH AN ADMINISTRATIVE APPROVAL BY CITY?S | | | PLANNING DIVISION IF THE USE AND/OR OPERATING HOURS OF | | | COMMERCIAL TENANTS SIGNIFICANTLY CHANGES IN THE FUTURE. | | | | | | 9. [ SATISFIED ] - PLEASE CONFIRM THAT VENTING THE | | | ROASTING EQUIPMENT INTO THE CORRIDOR IS PERMITTED BY | | | APPLICABLE BUILDING CODES, ETC. | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-07-27 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-07-27 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-07-27 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2021-07-27 09:26:09 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 07.27.2021 | | | PERMIT NO.: 21050671 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PLEASE PROVIDE A SITE PLAN OR SIMILAR SHOWING WHICH | | | BUILDING AND WHICH SPACE THIS IMPROVEMENT PERTAINS TO. | | | THERE IS NO CONTEXT ON THE FLOOR PLAN FOR ME TO KNOW | | | WHERE THIS IMPROVEMENTS ARE TAKING PLACE. | | | | | | 2. WHAT IS HAPPENING TO THE EXTERIOR DOOR ON THE NORTH | | | SIDE OF THE BUILDING, CLOSEST TO SOUTH DIXIE HIGHWAY? | | | THERE IS A SYMBOL WITH THE #1 THERE, BUT NO LEGEND OR | | | KEY FOR ME TO KNOW WHAT IS PROPOSED. | | | | | | 3. WHAT IS HAPPENING TO THE EASTERN-MOST DOOR THAT | | | CONNECTS TO THE CORRIDOR IN THE MIDDLE OF THE BUILDING? | | | | | | 4. ON SHEET 1.1A, WHAT ARE THE TWO AREA OUTLINED WITH A | | | DASHED LINE AND CONTAINING A SQUARE FOOTAGE | | | CALCULATION? | | | | | | 5. THE OUTDOOR SEATING SHOWN ON THE PLAN DOES NOT MATCH | | | THAT WHICH WAS APPROVED ON THE CASA MARA CPD SITE PLAN. | | | THE AREAS SHALL MATCH, OR IF THE AREA IS PROPOSED TO BE | | | MODIFIED, AN AMENDMENT TO THE CPD SHALL BE SUBMITTED TO | | | AND APPROVED BY THE PLANNING DIVISION. | | | | | | 6. THE OUTDOOR SEATING SHOWN ON THE PLAN CONFLICTS WITH | | | THE ACCESSIBLE ROUTE FROM THE ADJACENT ACCESSIBLE | | | PARKING SPACES. | | | | | | 7. THE PLANS DO NOT ACCURATELY REFLECT THE SIDEWALK, | | | LANDSCAPING ISLANDS, PARKING, ETC. ON THE EAST SIDE OF | | | THE BUILDING (ALONG SOUTH DIXIE HIGHWAY). | | | | | | 8. PURSUANT TO RESOLUTION NO. 108-21, THE DEVELOPER | | | SHALL DESIGNATE AT LEAST 71 ON-SITE PARKING SPACES | | | (OUTSIDE OF THE SECURITY GATE-CONTROLLED PARKING | | | FIELDS) TO BE RESERVED FOR USE BY PATRONS AND EMPLOYEES | | | OF THE NON-RESIDENTIAL USES. THE SPACES SHALL BE | | | RESERVED FOR SUCH USE BETWEEN THE HOURS OF 11:00 AM AND | | | 7:00 PM. OUTSIDE OF THOSE HOURS, THESE 71 PARKING | | | SPACES WILL BE AVAILABLE FOR USE BY THE NON-RESIDENTIAL | | | PATRONS/EMPLOYEES AS WELL AS RESIDENTS. | | | | | | SIGNAGE AND/OR MARKING TO DESIGNATE THESE SPACES WILL | | | BE DETERMINED AND IMPLEMENTED BY THE OWNER, SUBJECT TO | | | REVIEW AND APPROVAL BY THE CITY?S PLANNING DIVISION. | | | THE HOURS AND NUMBER OF SPACES DESIGNATED MAY BE | | | ADJUSTED THROUGH AN ADMINISTRATIVE APPROVAL BY CITY?S | | | PLANNING DIVISION IF THE USE AND/OR OPERATING HOURS OF | | | COMMERCIAL TENANTS SIGNIFICANTLY CHANGES IN THE FUTURE. | | | | | | 9. PLEASE CONFIRM THAT VENTING THE ROASTING EQUIPMENT | | | INTO THE CORRIDOR IS PERMITTED BY APPLICABLE BUILDING | | | CODES, ETC. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
|