Plan Review Details - Permit 21050633
Plan Review Stops For Permit 21050633
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-06-18 Cont ID  
Sent By jbrooks Date 2021-06-18 Time 09:21 Rev Time 0.00
Received By jbrooks Date 2021-06-18 Time 07:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-06-15 Cont ID  
Sent By jbrooks Date 2021-06-15 Time 12:21 Rev Time 0.00
Received By jbrooks Date 2021-06-15 Time 07:40 Sent To  
Notes
2021-06-15 12:21:19JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16709-R8 COVERS MULTIPLE ROOF SYSTEM TYPES
 A-2 THROUGH E, NO. W-1 THRU W-5. PLEASE SELECT SYSTEM
 NO.; EXPOSURE; ENCLOSURE; ROOF HEIGHT; ZONE AND
 ULTIMATE WIND SPEED. ALL APPLICABLE DETAILS AND
 ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT
 APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS NOT
 SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED
 SITE-SPECIFIC ENGINEERING. PLEASE SELECT THE CORRECT
 OPTIONS; CONSIDER USING FL16709-R8 SYSTEM NO. W-4;
 EXPOSURE C; ENCLOSED; ZONE 1 PRIME #1 (AS-LISTED), ZONE
 1 #2, ZONE 2 #4, & ZONE 3 #6; H < 15; 170 (MPH)
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-06-10 Cont ID  
Sent By jbrooks Date 2021-06-10 Time 13:39 Rev Time 0.00
Received By jbrooks Date 2021-06-10 Time 07:51 Sent To  
Notes
2021-06-10 13:39:25JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16709-R7 SELECTED SYSTEM NO W-4; EXPOSURE
 (B); ENCLOSURE (OPEN); ROOF HEIGHT (H < 15); ZONES 1
 PRIME, 1, 2, & 3; ULTIMATE WIND SPEED (160), IS NOT
 CORRECT. THE ULTIMATE WIND SPEED FOR THE LISTED ADDRESS
 IS 170 (MPH). PLEASE SELECT THE CORRECT OPTIONS;
 CONSIDER USING SYSTEM NO. W-4; EXPOSURE C; ZONES 1
 PRIME, 1, 2, & 3; ENCLOSED; H < 15; 180 (MPH).
 2. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL16709-R7 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-4 TO
 INCLUDE LIMITATIONS PAGE(S). THE EVALUATION REPORTS CAN
 BE PRINTED FROM THE SUMMARY OF PRODUCTS LOCATED AT THE
 BOTTOM OF THE COVER PAGE. PRINT PAGES 1-4 ONLY. SECOND
 REQUEST.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-05-19 Cont ID  
Sent By jbrooks Date 2021-05-19 Time 09:43 Rev Time 0.00
Received By jbrooks Date 2021-05-19 Time 07:31 Sent To  
Notes
2021-05-19 09:44:36JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL16709-R7 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-4 TO
 INCLUDE LIMITATIONS PAGE(S).
 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16709-R7 COVERS MULTIPLE ROOF SYSTEM NO. W-1
 THRU W-5. PLEASE SELECT CORRECT OPTIONS FOR SYSTEM NO
 W-4; EXPOSURE (C); ENCLOSURE (ENCLOSED); ROOF HEIGHT
 (H<15); ULTIMATE WIND SPEED (180). ALL APPLICABLE
 DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON
 THE PRODUCT APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS
 NOT SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED
 SITE-SPECIFIC ENGINEERING.
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2021-05-25 Cont ID  
Sent By aborngra Date 2021-05-25 Time 16:17 Rev Time 0.00
Received By aborngra Date 2021-05-25 Time 16:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-06-18 Cont ID  
Sent By jbrooks Date 2021-06-18 Time 09:21 Rev Time 0.00
Received By jbrooks Date 2021-06-16 Time 08:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-06-15 Cont ID  
Sent By jbrooks Date 2021-06-15 Time 12:21 Rev Time 0.00
Received By jbrooks Date 2021-06-11 Time 13:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-06-10 Cont ID  
Sent By jbrooks Date 2021-06-10 Time 13:39 Rev Time 0.00
Received By jbrooks Date 2021-06-03 Time 08:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-25 Cont ID  
Sent By jbrooks Date 2021-05-25 Time 16:26 Rev Time 0.00
Received By lmarchan Date 2021-05-18 Time 12:27 Sent To  
Notes
***NONE***