| Plan Review Stops For Permit 21050405 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-06-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-30 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-30 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2021-06-30 12:43:01 | EXISTING STRUCTURAL SLAB. DESIGN WIND LOADS APPROVED. | | | CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-29 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-29 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2021-06-29 15:52:06 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: VALUE ADJUSTED FROM $9,275.00 TO $14,791.25 PER | | | THE CONTRACT PAYMENT SCHEDULE. | | | | | | 1. PROVIDE A STRUCTURAL CONCRETE SLAB FOR THE | | | GENERATOR. PROVIDE A CONNECTION DETAIL BASED ON THE | | | DESIGN WIND LOADS. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-11 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-29 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2021-05-29 10:46:24 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: VALUE ADJUSTED FROM $9,275.00 TO $14,791.25 PER | | | THE CONTRACT PAYMENT SCHEDULE. | | | | | | 1. PROVIDE A STRUCTURAL CONCRETE SLAB FOR THE | | | GENERATOR. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PROVIDE THE DESIGN WIND LOADS OF THE GENERATOR. | | | FBC 107.3.5.3 PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-06-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-25 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-25 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-05-21 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-21 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-05-21 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2021-05-21 11:41:38 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW: | | | | | | 1) PERMIT VALUE SEEMS LOW. THE CONTRACT SHOWS A TOTAL | | | COST OF $13475.00 WITH $800.00 FOR GAS. | | | IT SEEMS PERMIT VALUE ONLY INCLUDED THE BALANCE AFTER | | | THE DEPOSIT. PLEASE RESUBMIT PERMIT APPLICATION WITH | | | CORRECT PERMIT VALUE. | | | | | | ENRIQUE QUINONEZ PE | | | ELECTRICAL PLANS EXAMINER | | | DEVELOPMENT SERVICES | | | CITY OF WEST PAM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6746. | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-06-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-06-30 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-06-30 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2021-06-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-05-26 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-05-26 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-05-28 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2021-05-28 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2021-05-28 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-06-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-06-21 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-05-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-29 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-10 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-06-30 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-06-30 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2021-05-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-05-26 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-05-26 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-29 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-29 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-05-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-29 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-29 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2021-05-29 10:41:45 | SIGNATURE REVIEW REQUIRED UPON SUBMITTAL OF STRUCTURAL | | | CONCRETE GENERATOR PAD AND DESIGN WIND LOADS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-05-28 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-05-28 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2021-05-28 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|