Plan Review Details - Permit 21050364
Plan Review Stops For Permit 21050364
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-07-22 Cont ID  
Sent By cthroop Date 2021-07-22 Time 10:45 Rev Time 0.00
Received By cthroop Date 2021-07-22 Time 08:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-06-02 Cont ID  
Sent By cthroop Date 2021-06-02 Time 10:34 Rev Time 0.00
Received By cthroop Date 2021-06-02 Time 09:14 Sent To  
Notes
2021-06-02 10:52:59PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER PX3169 1&2 FAMILY - SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE DESIGN PRESSURES FOR ALL NEW WINDOW AND EXT.
 DOOR OPENINGS. YOU MAY PLACE THE PRESSURES ON YOUR
 WINDOW AND DOOR SCHEDULES.
 FBC 107.3.5.3 PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
  
 R301.2.1 WIND DESIGN CRITERIA.
 BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN
 ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING
 THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED
 FROM FIGURE R301.2(4).
  
 2. ENTRY DOOR PRODUCT APPROVAL HAS EXPIRED. SUBMIT A
 PRODUCT APPROVAL, INCLUDING THE COVER SHEET, APPROVED
 PER THE 2020 FBC.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE
 VERSION, AND STATUS, FBC R 301.
 (COVER SHEETS ARE NOT REQUIRED FOR MIAMI DADE NOAS.)
  
 3. WINDOW SCHEDULE LIST'S HORIZONTAL SLIDERS. PRODUCT
 APPROVAL SUBMITTED FOR REVIEW IS FOR SINGLE HUNG
 WINDOWS. PLEASE CLARIFY.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-06-02 Cont ID  
Sent By jleahy Date 2021-06-02 Time 16:41 Rev Time 0.00
Received By jleahy Date 2021-06-02 Time 16:36 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-07-19 Cont ID  
Sent By abelisle Date 2021-07-16 Time 12:02 Rev Time 0.00
Received By abelisle Date 2021-07-16 Time 10:31 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-06-02 Cont ID  
Sent By ccole Date 2021-06-02 Time 10:14 Rev Time 0.00
Received By ccole Date 2021-06-02 Time 09:34 Sent To  
Notes
2021-06-02 10:14:271ST REVIEW FBC-2020 RES. FUEL GAS
 PERMIT- 21050364
 6/2/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P2.0: SHEET P1: THE GAS PIPING AND APPLIANCE
 INSTALLATIONS FOR THE PROPOSED PROJECT SHALL BE
 DESIGNED AND INSTALLED IN ACCORDANCE WITH THE FBC- 2020
 7TH EDITION RESIDENTIAL CODE. PLEASE REVISE THE
 INCORRECT COMPLIANCE DATA AND CODE SECTIONS SPECIFIED
 IN THE NOTES- SECTION 107.2.1 WPB.
  
 2) P2.0: CORRECT THE NOTE ON THE RISER INDICATING PE
 PIPING ON THE INSIDE AND CAST IRON ON THE OUTSIDE. PE
 PIPE IS FOR OUTDOOR UNDERGROUND USE ONLY- SECTION
 G2415.17.1, AND CAST IRON IS NOT AN APPROVED GAS PIPING
 MATERIAL- SECTION G2414.4.1 FBC RES.
  
 3) P2.0: FBC RES. FUEL GAS CHAPTER 24 AND SECTION
 107.3.5.3 - PROVIDE A COMPLETE CODE COMPLIANT RISER
 DRAWING WITH THE FOLLOWING INFORMATION:
 A) DELIVERY PRESSURE AT THE METER.
 B) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 C) TYPES AND SIZES OF PIPING.
 D) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 E) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 F) LOCATIONS OF REGULATORS, SHUTOFF VALVES, DRIP LEGS,
 AND PIPE UNIONS.
 G) OUTLET PRESSURES AT REGULATORS.
 H) LOCATIONS AND TYPES OF PIPE SLEEVES.
 I) PIPE SIZING TABLES.
  
 4) P2.0 GAS WATER HEATER: PLACE A NOTE INDICATING NEW
 OR EXISTING VENT SYSTEM. IF A NEW SYSTEM IS TO BE
 INSTALLED, PLEASE REFER TO SECTIONS G2427.1 & G2448.1
 FBC RES AND PROVIDE A DIAGRAM AND SPECIFICATIONS.
  
 5) P2.0: PROVIDE COMBUSTION AIR CALCULATIONS FOR THE
 RANGE AND INDICATE HOW THE AIR WILL BE PROVIDED- REFER
 TO SECTION G2407.1 FBC RES.
  
 6) P2.0: BASED ON THE INSTALLATION MANUAL FOR THE NEW
 ARTISAN BBQ GRILL, THE UNIT SHALL NOT BE INSTALLED
 UNDER OVERHEAD COMBUSTIBLE CONSTRUCTION OR IN AN
 ENCLOSED AREA. PLEASE SEE PAGES 5 & 6 OF THE MANUAL AND
 SHOW COMPLIANCE- SECTION G2408.1 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-07-22 Cont ID  
Sent By cthroop Date 2021-07-22 Time 10:45 Rev Time 0.00
Received By cthroop Date 2021-07-13 Time 13:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-06-24 Cont ID  
Sent By jleahy Date 2021-06-24 Time 10:27 Rev Time 0.00
Received By jleahy Date 2021-05-07 Time 09:43 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-07-19 Cont ID  
Sent By medwards Date 2021-07-19 Time 06:42 Rev Time 0.00
Received By medwards Date 2021-07-19 Time 06:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-06-02 Cont ID  
Sent By medwards Date 2021-06-02 Time 07:46 Rev Time 0.00
Received By medwards Date 2021-06-02 Time 07:34 Sent To  
Notes
2021-06-02 07:48:51PLEASE PROVIDE A SCOPE OF WORK FOR THE MECHANICAL
 SYSTEMS, THE GENERAL HVAC NOTES DISCUSS THE DUCTWORK
 FOR THE SYSTEM BUT THERE IS NOTHING ON THE DRWINGS
 ABOUT ANY NEW WORK BEING DONE OTHER THAN THE HOOD, BATH
 EXHAUST AND RETURN TRANSFER GRILL FOR BEDROOM 4.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-07-19 Cont ID  
Sent By abelisle Date 2021-07-16 Time 12:02 Rev Time 0.00
Received By abelisle Date 2021-07-16 Time 10:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-06-02 Cont ID  
Sent By ccole Date 2021-06-02 Time 09:31 Rev Time 0.00
Received By ccole Date 2021-06-02 Time 07:22 Sent To  
Notes
2021-06-02 09:32:081ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 21050364
 6/2/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P1: THE PLUMBING SYSTEMS FOR THE PROPOSED
 PROJECT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE
 WITH THE FBC- 2020 7TH EDITION RESIDENTIAL CODE. PLEASE
 REVISE THE INCORRECT COMPLIANCE DATA AND CODE SECTIONS
 SPECIFIED IN THE NOTES- SECTION 107.2.1 WPB.
  
 2) P1: UNDER NOTE #17 PLEASE INCLUDE THE COMPLIANCE AND
 CONFORMANCE DATA FOR THE BATH TUB VALVE- SEE SECTION
 P2713.3 FBC RES.
  
 3) P1.1: PLEASE ADD THE SLOPE OF THE FINISHED SHOWER
 FLOOR TO THE DETAIL- 1/4 UNIT VERTICAL IN 12 UNITS
 HORIZONTAL (2-PERCENT SLOPE) NOR MORE THAN 1/2 UNIT
 VERTICAL PER 12 UNITS HORIZONTAL (4-PERCENT SLOPE)-
 SECTION P2709.1 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-07-19 Cont ID  
Sent By medwards Date 2021-07-19 Time 06:43 Rev Time 0.00
Received By medwards Date 2021-07-19 Time 06:43 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-06-02 Cont ID  
Sent By medwards Date 2021-06-02 Time 07:54 Rev Time 0.00
Received By medwards Date 2021-06-02 Time 07:54 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-06-22 Cont ID  
Sent By rthermid Date 2021-06-22 Time   Rev Time  
Received By rthermid Date 2021-06-22 Time   Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy