Plan Review Details - Permit 21050305
Plan Review Stops For Permit 21050305
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-05-06 Cont ID  
Sent By cpuell Date 2021-05-06 Time 16:50 Rev Time 0.00
Received By cpuell Date 2021-05-06 Time 16:50 Sent To  
Notes
2021-05-06 16:50:58ADDRESS CHANGED TO 366 S ROSEMARY AVE AS AGREED UPON
 WITH DEVELOPERS.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 4 Status P Date 2022-04-26 Cont ID  
Sent By jwitmer Date 2022-04-26 Time 09:53 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status F Date 2021-11-09 Cont ID  
Sent By jwitmer Date 2021-11-09 Time 08:49 Rev Time 0.00
Received By jwitmer Date 2021-11-09 Time 08:48 Sent To  
Notes
2021-11-09 08:49:12COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected] THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-10-05 Cont ID  
Sent By jwitmer Date 2021-10-05 Time 13:18 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2021-10-05 13:18:14COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected] THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-06-15 Cont ID  
Sent By jwitmer Date 2021-06-15 Time 11:59 Rev Time 0.00
Received By jwitmer Date 2021-06-15 Time 10:27 Sent To  
Notes
2021-06-15 11:59:13COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 WE UNDERSTAND THAT THIS IS A NEW HIGHRISE BUILDING, BUT
 THE PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS
 VERIFICATION THE CONTRACTORS ARE AWARE OF THIS FL.
 STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-11-09 Cont ID  
Sent By jwitmer Date 2021-11-09 Time 08:58 Rev Time 0.00
Received By jwitmer Date 2021-11-09 Time 08:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-10-05 Cont ID  
Sent By jwitmer Date 2021-10-05 Time 13:31 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-06-15 Cont ID  
Sent By jwitmer Date 2021-06-15 Time 11:59 Rev Time 0.00
Received By jwitmer Date 2021-06-15 Time 10:27 Sent To  
Notes
2021-06-15 11:54:11WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21050305
 ADD: 366 S. ROSEMARY AVE.
 CONT: TBD/ TO BE DETERMINED
 TEL: ??
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JUNE 15TH/ 2021
 ACTION: DENIED
  
 1) THE SHEET ALS1.2 UNDER THE HEADING CODE ANALYSIS
 INDICATES UNDER ACCESSIBILITY 5% OF DINING REQUIRED
 SEATING OR 15 ACCESSIBLE SEATS REQUIRED. THE 15
 ACCESSIBLE SEATS ARE NOT SHOWN. THE LIFE SAFETY SHEET
 DOES NOT SHOW COMPLIANCE WITH THE 2020
 FBC-ACCESSIBILITY CODE.
 1A) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE
 CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE
 SEATING SPACES AND STANDING SPACES AT THE DINING
 SURFACES SHALL COMPLY WITH 902.
  
 1B) 226.2 DISPERSION. DINING SURFACES AND WORK SURFACES
 REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED
 THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING
 SURFACES AND WORK SURFACES.
  
 1C) 206.2.5 206.2.5 RESTAURANTS AND CAFETERIAS. IN
 RESTAURANTS AND CAFETERIAS, AN ACCESSIBLE ROUTE SHALL
 BE PROVIDED TO ALL DINING AREAS, INCLUDING RAISED OR
 SUNKEN DINING AREAS, AND OUTDOOR DINING AREAS.
  
 1D) 902.1. DINING SURFACES AND WORK SURFACES SHALL
 COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 GENERAL.
 DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS,
 TABLES, LUNCH COUNTERS, AND BOOTHS. EXAMPLES OF WORK
 SURFACES INCLUDE WRITING SURFACES, STUDY CARRELS,
 STUDENT LABORATORY STATIONS, BABY CHANGING AND OTHER
 TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON
 COUNTERS, AND WHERE COVERED BY THE ADA SCOPING
 PROVISIONS, EMPLOYEE WORKSTATIONS.
  
 1D)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR
 SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD
 APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 1D)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND
 WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 2A) SHEET A5.0.1. AT THE TOP OF THE SHEET TYPICAL
 MOUNTING HEIGHTS FOR W. C. GRAB BARS IS DETAILED
 CORRECTLY, 36 INCHES TO THE TOP OF THE GRASPABLE
 SURFACE. THE DETAILS, DETAIL 2 RESTROOM 102 AND DETAIL
 8 RESTROOM 103 IN BOTH CASES THE GRAB BARS AT THE W. C.
 ARE BOTH DIMENSIONED FROM FINISH FLOOR TO THE
 CENTERLINE OF THE GRAB BAR, 36 INCHES.
 2020 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF
 GRAB BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
 2B) THE BACK-BAR DETAIL 10 IS DIMENSIONED FROM FINISH
 FLOOR TO TOP OF COUNTER AS 37 INCHES. 902.1. WORK
 SURFACES SHALL COMPLY WITH 902.2 AND 902.3. ADVISORY
 902.1 GENERAL. DINING SURFACES INCLUDE, BUT ARE NOT
 LIMITED TO, BARS, TABLES, LUNCH COUNTERS, AND BOOTHS.
 EXAMPLES OF WORK SURFACES INCLUDE WRITING SURFACES,
 STUDY CARRELS, STUDENT LABORATORY STATIONS, BABY
 CHANGING AND OTHER TABLES OR FIXTURES FOR PERSONAL
 GROOMING, COUPON COUNTERS, AND WHERE COVERED BY THE ADA
 SCOPING PROVISIONS, EMPLOYEE WORKSTATIONS.
 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND WORK
 SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 3) SHEET S0.00 GENERAL NOTES. BUILDING CLASSIFICATION.
 STATES THIS BUILDING IS NOT A THRESHOLD BUILDING. THIS
 IS A HIGHRISE BUILDING THAT IF STRUCTURAL WORK THAT
 AFFECTS ANY PORTION OF THE HIGHRISE STRUCTURE WOULD
 REQUIRE A THRESHOLD INSPECTION REPORT AS WELL AS A
 THRESHOLD INSPECTOR. THE FIRST-FLOOR TENANT SLABS DOES
 NOT AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING,
 THUS NOT REQUIRING A THRESHOLD INSPECTOR. PLEASE
 CORRECT THE LANGUAGE USED IN DEFINING THIS BUILDING AND
 WHY A THRESHOLD INSPECTOR IS NOT REQUIRED.
  
 4A) SHEET M2.0.3. EAST WALL SHOWS 2 THROUGH THE WALL
 LOUVERS, A 48X42 INCH (1) INTAKE AND (1) EXHAUST
 LOUVER. PLEASE PROVIDE THE PRODUCT APPROVAL FOR THESE
 LOUVERS. 2020 FBC-B 1609.6.4.4.1 COMPONENTS & CLADDING.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE
 CODE 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS: (31)(C) WALL LOUVERS.
  
 4B) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP
 DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD
 PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 4C) PROVIDE THE PRESSURES IN VASD FOR THESE WALL
 LOUVERS. 2020 FBC-B 1603.1.4 WIND DESIGN DATA.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-10-21 Cont ID  
Sent By fgiaquin Date 2021-10-21 Time 19:29 Rev Time 0.00
Received By fgiaquin Date 2021-10-21 Time 19:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-06-23 Cont ID  
Sent By fgiaquin Date 2021-06-23 Time 20:34 Rev Time 0.00
Received By fgiaquin Date 2021-06-23 Time 19:11 Sent To  
Notes
2021-06-23 20:34:00ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. APPLICATION SAYS "360 S ROSMARY #1500" PLANS SAY
 "360 S ROSEMARY SUITE 101" AND ADDRESS FROM CITY
 ADDRESSING PER AGREEMENT WITH DEVELOPERS HAS BEEN
 CHANGED TO "366 S ROSEMARY". PERMIT APPLICATION AND
 PLANS MUST REFLECT ACCURATE ADDRESS (366 S ROSEMARY).
 FBC 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-805-6744
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-10-04 Cont ID  
Sent By pleduc Date 2021-10-04 Time   Rev Time 0.00
Received By pleduc Date 2021-10-04 Time 10:55 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-06-11 Cont ID  
Sent By pleduc Date 2021-06-11 Time   Rev Time 0.00
Received By pleduc Date 2021-06-11 Time 11:54 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-10-22 Cont ID  
Sent By lcrespo Date 2021-10-22 Time 12:41 Rev Time 0.00
Received By lcrespo Date 2021-10-18 Time 12:26 Sent To  
Notes
2021-10-22 12:41:3110/22/21 REVIEWED FOR CODE COMPLIANCE (GAS)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-07-16 Cont ID  
Sent By tklarge Date 2021-07-16 Time 13:23 Rev Time 0.00
Received By tklarge Date 2021-07-16 Time 12:42 Sent To  
Notes
2021-07-16 13:15:171) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE GAS
 EQUIPMENT. EQUIPMENT SHALL BE LISTED AND LABELED PER
 FBC-FUEL GAS SEC. 301.3.
 2) IDENTIFY EACH APPLIANCE ON THE GAS RISER ALONG WITH
 THE BTU LOAD FOR EACH APPLIANCE. WPB AMEND. TO FBC SEC.
 107.2.1.
 3) SIZE ALL DROPS ON HE GAS RISER AND SIZE THE GAS LOOP
 AND ALL LINES DOWNSTREAM OF THE REGULATORS.. WPB AMEND.
 TO FBC SEC. 107.2.1.
 4) ) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE GAS
 APPLIANCES. 2017 FBC-FUEL GAS SEC. 304.1. WHERE
 COMBUSTION AIR IS PROVIDED BY THE BUILDING?S MECHANICAL
 VENTILATION SYSTEM, THE SYSTEM SHALL PROVIDE THE
 SPECIFIED COMBUSTION AIR RATE IN ADDITION TO THE
 REQUIRED VENTILATION AIR. FBC-FUEL GAS SEC.304.9.3 OR
 FBCR G2407.9.3.
 5) SUBMIT MANUFACTURER'S SPECIFICATIONS AND
 INSTALLATION INSTRUCTIONS FFOR THE REGULATORS. WPB
 AMEND. TO FBC SEC. 107.2.1.
 6) SHT.FG0.0.0 - NATURAL GAS PIPE SIZING TABLE - THE
 TABLE LISTS THE 2 PSI SYSTEM AS COMPLYING WITH TABLE
 402.4 (3) OF THE FUEL GAS CODE. THIS TABLE IS FOR LESS
 THAN A 2 PSI SYSTEM. PROVIDE THE CORRECT SIZING TABLE
 FOR THE 2 PSI SYSTEM.WPB AMEND. TO FBC SEC. 107.2.1.
 7) SHT. FG0.0.0 - THE GAS SIZING TABLE ALSO REFERS TO
 THE 2017 FUEL GAS CODE. THE GAS CODE IN EFFECT IS THE
 2020 CODE. REVISE THE TABLE TO REFLECT THE 2020 CODE.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2021-11-10 Time   Rev Time 0.00
Received By aoliver Date 2021-11-02 Time 14:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-10-22 Cont ID  
Sent By mpeterso Date 2021-10-22 Time 12:47 Rev Time 0.00
Received By mpeterso Date 2021-10-22 Time 12:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-10-22 Cont ID  
Sent By lcrespo Date 2021-10-22 Time 12:41 Rev Time 0.00
Received By lcrespo Date 2021-09-30 Time 09:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-07-16 Cont ID  
Sent By lmarchan Date 2021-07-16 Time 13:33 Rev Time 0.00
Received By lmarchan Date 2021-05-28 Time 14:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-10-13 Cont ID  
Sent By hmoser Date 2021-10-13 Time 09:00 Rev Time 0.00
Received By hmoser Date 2021-10-13 Time 07:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-06-24 Cont ID  
Sent By medwards Date 2021-06-24 Time 08:56 Rev Time 0.00
Received By medwards Date 2021-06-24 Time 08:56 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-11-10 Cont ID  
Sent By ccole Date 2021-11-10 Time 17:16 Rev Time 0.00
Received By ccole Date 2021-11-10 Time 16:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-10-21 Cont ID  
Sent By lcrespo Date 2021-10-21 Time 15:50 Rev Time 0.00
Received By lcrespo Date 2021-10-18 Time 12:25 Sent To  
Notes
2021-10-21 15:50:3710/21/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. DONE.
  
 2. DONE.
  
 3. DONE.
  
 4. DONE.
  
 5. DONE AND NEW COMMENTS ON PAGE A 501;
  
 A. THE DETAIL A ON THE TOILET GRAB BAR SAYS 6 INCHES
 FROM THE WALL, WHICH IS NOT AN ACTUAL NUMBER AS THE
 TOILET IS 16 INCHES TO 18 INCHES TO THE CENTER, AND
 THAT NUMBER MAY CONFUSE THE INSTALLER. WOULD YOU PLEASE
 CORRECT PER THE 2020 FBC ACC SEC. 604.2 LOCATION AND
 WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS?
  
 B. ON DETAIL THREE, THE BOTTOM ON THE LAV SHALL BE A
 MINIMUM OF 27 INCHES KNEE CLEARANCE PER THE 2020 FBC
 SEC. 306.3.
  
 6. DONE.
  
 7. DONE.
  
 8. DONE.
  
 9. DONE.
  
 10. DONE.
  
 11. DONE.
  
 12. NEW COMMENT, ON SHEET P2.1.1, SHOWS HOT WATER LINES
 UNDERGROUND AND NOT IN CONDITION SPACE NEED TO BE
 INSULATED WITH A MINIMUM R-3 PER THE 2020 FBC SEC. RE
 403.5.3.
  
 13. NEW COMMENT,
  
  
 A. ON SHEETS P4.11, IT SHOWS THE MOP SINK GOING INTO
 THE SANITARY, AND IT SHOULD GO INTO THE GREASE
 INTERCEPTOR.
  
 B. WOULD YOU PLEASE SHOW A TRAP PRIMER PER THE 2020 FBC
 SEC. 1002.4.1 TRAP SEAL PROTECTION.
  
 14. NEW COMMENT ON SHEET P4.1.2;
  
 A. WOULD YOU PLEASE SHOW LOCATIONS OF WATER HAMMER
 ARRESTORS FOR ALL QUICK CLOSING VALVES PER THE 2020 FBC
 SEC. P 604.9.
  
 B. WOULD YOU PLEASE SHOW THE MAIN SHUTOFF VALVE PERT
 THE 2020 FBC SEC. P 606.1.
  
 C. WOULD YOU PLEASE NOTE NEXT TO THE WATER HEATER
 REEFING TO THE DETAIL ON PAGE P5.1.1 PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-07-16 Cont ID  
Sent By tklarge Date 2021-07-16 Time 12:41 Rev Time 0.00
Received By tklarge Date 2021-07-01 Time 05:21 Sent To  
Notes
2021-07-16 06:44:231) SHT. ALS 1.2 - CODE DATA TABLE - THE 202 FLORIDA
 BUILDING CODE IS IN EFFECT, NOT THE 2017. REVISE THE
 CODES.
 2) SHT. ALS 1.2 - PLUMBING FIXTURE CALCULATIONS TABLE -
 THE NUMBER OF FIXTURES SHOWN IN THE TABLE DO NOT MATCH
 THE NUMBER OF FIXTURES SHOWN ON THE FLOOR PLAN. WHERE
 ARE THE OTHER FIXTURES LOCATED?
 3) A NOTE AT THE BOTTOM OF THE FIXTURE CALCULATION
 TABLE STATES "1 UNISEX STAFF RESTROOM PROVIDED IN
 TENANT SPACE." WHERE IS THIS RESTROOM?
 4) SHOW THE LOCATION AND SIZE OF THE GREASE
 INTERCEPTOR. SUBMIT SIZING CALCUALTIONS FOR THE
 INTERCEPTOR TO ENSURE PROPER CAPACITY PER FBC-PLUMBING
 SEC. 1003.2.
 5) PROVIDE A WALL FINISH SCHEDULE FOR THE TOILET ROOMS
 AND FOR THE WALLS AROUND THE SERVICE SINK. WALL FFINISH
 SHALL COMPLY WITH FBC-BUILDDING SEC.1210.2.2.
 6) SHT. A 5.0.1 - DETAILS "A" & "B" - THE GRAB BAR
 ADJACENT TO THE WATER CLOSET IS SHOWN AS BEING 6 INCHES
 FROM THE REAR WALL. THIS GRAB BAR IS REQUIRED TO EXTEND
 A MINIMUM OF 54 INCHE FROM THE REAR WALL. REFER TO
 FBC-ACCESS. SEC.604.5.1 AND FIGURE 604.5.1.THE MOUNTING
 HEIGHT DETAILS SHOW 12 INCHES.
 7) SHT. GI.0.1 - SHEET INDEX - THERE ARE SHEETS LISTED
 IN THE INDEX THAT ARE NOT PART OF THIS SUBMITTAL.
 CLARIFY.
 8) SHT. P.0.0 - NOTE #33 - THE REFERENCED ASSE 1022
 BACKFLOW DEVICE IS FOR CARBONATED BEVERAGE DISPENSERS.
 BACKFLOW DEVICES FOR COFFEE AND NON-CARBONATED BEVERAGE
 DISPENSERS IS ASSE 1024.
 9) THE WATER FILTER SYSTEM SHALL BE EQUIPPED WITH A
 BACKFLOW PREVENNTER. FBC-PLUMBING SEC.608..4.
 10) SHT.P4.11 - IDENTIFY ALL FIXTURES/EQUIPMENT ON THE
 WATER RISER. WPB AMEND. TO FBC SEC. 107.2.1.
 11) SHT.P4.11 - SUBMIT AN EXPANDED WATER RISER FOR
 REVIEW. IT IS EXTREMELY DIFFICULT TO DETERMINE WHERE
 HOT AND COLD WATER LINES ARE CONNECTED. WPB AMEND. TO
 FBC SEC. 107.2.1.
 12) SUBMIT DETAILS ON THE WATER HEATER STAND AND HOW IT
 WILL BE FASTENED TO THE WALL. WPB AMEND. TO FBC SEC.
 107.2.1.
 13) THE HOT WATER SYSTEM AND RECIRCULATION SYSTEM SHALL
 BE INSULATED WITH A MINIMUM OF 1 INCH THICK INSULATION
 AND SHALL BE INSULATED IN ACCORDANCE WWITH TABLE
 C403.2.10 OF THE FBC-ENERGY DEPENDING ON THE PIPE SIZE.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop P-GREASE GREASE INTERCEPTOR/TRAP REVIEW
Rev No 1 Status N Date 2021-11-10 Cont ID  
Sent By ccole Date 2021-11-10 Time 17:17 Rev Time 0.00
Received By ccole Date 2021-11-10 Time 17:16 Sent To  
Notes
2021-11-10 17:17:33SEPARATE PERMIT REQUIRED FOR THE GREASE INTERCEPTOR

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status N Date 2022-11-18 Cont ID  
Sent By shill Date 2022-11-18 Time 14:16 Rev Time 0.00
Received By shill Date 2022-11-18 Time 14:16 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status N Date 2022-11-17 Cont ID  
Sent By shill Date 2022-11-17 Time 16:14 Rev Time 0.00
Received By shill Date 2022-11-17 Time 16:14 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2022-03-02 Cont ID  
Sent By rgathrig Date 2022-03-02 Time 13:24 Rev Time 0.00
Received By rgathrig Date 2022-03-02 Time 13:24 Sent To  
Notes
2022-03-02 13:26:44RR REVIEW FOR INSPECTIONS ONLY APPROVED
  
 RICHARD GATHRIGHT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-11-09 Cont ID  
Sent By jwitmer Date 2021-11-09 Time 09:02 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-10-22 Cont ID  
Sent By mpeterso Date 2021-10-22 Time 12:43 Rev Time 0.00
Received By mpeterso Date 2021-10-22 Time 12:43 Sent To  
Notes
2021-10-22 12:45:33REVIEW OF SIGNATURE AND SEAL ON DIGITAL PLANS APPROVED

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-06-24 Cont ID  
Sent By medwards Date 2021-06-24 Time 09:04 Rev Time 0.00
Received By medwards Date 2021-06-24 Time 09:04 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-06-10 Cont ID  
Sent By aaponte Date 2021-06-10 Time 12:04 Rev Time 0.00
Received By aaponte Date 2021-06-10 Time 12:04 Sent To  
Notes
***NONE***