| Plan Review Stops For Permit 21050214 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2021-06-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-16 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-16 |
Time |
12:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-06-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-16 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-16 |
Time |
12:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-07-14 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-07-14 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-07-14 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-06-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-16 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-16 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2021-06-16 16:17:40 | PLAN REVIEW / FUEL GAS | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1. SUBMIT LOW PRESSURE GAS REGULATOR SPECIFICATIONS. | | | 2020 FBC FUEL GAS SEC.305.1 OR 2020 FBC FUEL GAS RES. | | | SEC. G2408.1. | | | | | | NOTICE: REGULATORS SHALL HAVE A UNION INSTALLED WITHIN | | | 1 FOOT OF EITHER SIDE OF THE REGULATOR FBC FG 410.2 | | | | | | NOTICE: REGULATORS SHALL BE LOCATED PER 409.1.3. | | | | | | 2. GAS PRODUCT SPECS INCLUDE ABOVE GROUND/UNDER GROUND | | | LPG TANK INSTALLATION INSTRUCTIONS. GAS RISER INDICATES | | | A NEW NG 2PSI METER WILL BE INSTALLED. | | | PLEASE CLARIFY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-08-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-08-16 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-08-11 |
Time |
07:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-07-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-07-16 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-07-01 |
Time |
10:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-06-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-24 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-05-07 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2021-07-14 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-07-14 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-07-14 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2021-06-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-16 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-16 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-06-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-16 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-16 |
Time |
12:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-08-13 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2021-08-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2021-08-13 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-07-15 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2021-07-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2021-07-15 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-07-15 12:44:05 | ********************************ZONING REVIEW | | | FAILED******************************* | | | | | | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN FOUR | | | FEET INTO A SETBACK. | | | | | | IF THE LOCATION OF THE GENERATOR IS TO BE OFF THE REAR | | | PROPERTYLINE THE SETBACK MUST BE 8 FEET FROM THE REAR | | | PROPERTYLINE. | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-06-22 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2021-06-22 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2021-06-22 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-22 10:29:38 | ********************************ZONING REVIEW | | | FAILED******************************* | | | | | | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN FOUR | | | FEET INTO A SETBACK. | | | | | | IF THE LOCATION OF THE GENERATOR IS TO BE OFF THE REAR | | | PROPERTYLINE THE SETBACK MUST BE 8 FEET FROM THE REAR | | | PROPERTYLINE. | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|