| Plan Review Stops For Permit 21050159 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-06-21 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-06-21 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2021-06-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-06-01 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-06-01 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2021-06-01 12:12:37 | TO THE BUILDING CONTRACTOR: | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. | | | | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-05-25 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-05-25 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2021-05-25 09:43:10 | TO THE BUILDING CONTRACTOR: | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-06-21 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-06-21 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-06-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-06-01 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-06-01 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2021-06-01 12:09:54 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21050159 | | | ADD: 1501 S. FLAGLER DR. # 3H | | | CONT: FERRER & ASSOC. OF FLORIDA | | | TEL: 561-936-1998 | | | E-MAIL: FERRERFLA#AOL.COM | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUES. MAY 25TH/ 2021 | | | ACTION: DENIED | | | NOTE I SPOKE WITH THE CGC THIS MORNING ABOUT COMMENTS. | | | | | | 1) VOIDED PLANS. THE SUBMITTED SHEETS THE OVERALL 3RD | | | FLOOR PLAN AND THE APARTMENT FLOOR PLAN BOTH ARE COPIES | | | OF PLANS DESIGNED BY PACHER & CITRON ARCHITECTS. COPIES | | | OF THESE PLANS ARE NOT VALID PLANS WITHOUT THE | | | PERMISSION OF THE DESIGNERS OF RECORD, PLANS ARE | | | COPY-RIGHTED. THEY CAN NOT BE TURNED IN WITHOUT THE | | | ORIGINAL SIGNATURE AND SEAL. FL ADMIN CODE 61G16.003(1) | | | ARCHITECTS. PLANS, SPECIFICATIONS, REPORTS OR OTHER | | | DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND BEING | | | FILED FOR PUBLIC RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED TO THE | | | DOCUMENT. | | | | | | 2) THE SUBMITTED KITCHEN FLOOR PLAN DOES NOT INDICATE | | | WHO THE AUTHOR OF THIS PLAN IS CERTIFICATION BY | | | CONTRACTOR. 107.3.4.3. THE CONTRACTOR (QUALIFIER) THAT | | | CREATED / DREW THE SET OF PLANS WILL NEED TO IDENTIFY | | | THEMSELVES AS THE AUTHOR OF THE PLANS. PLEASE PRINT | | | YOUR NAME, SIGN YOUR NAME AND LICENSE NUMBER FOR THE | | | TRADE YOU ARE LICENSED IN AND PLANS DRAWN. | | | | | | 3) THE PERMIT APPLICATION UNDER THE DESCRIPTION OF WORK | | | LISTED FLOORING, BUT ON THE KITCHEN FLOOR PLAN THERE IS | | | NO MENTION OF FLOORING, THE SCOPE OF WORK FOR THE | | | BATHROOMS IS NOT CLEAR SINCE THE APPLICATION STATES | | | PLURAL VANITIES, AND TILE. WHAT DOES THE TILE INCLUDE | | | BATHROOM FLOOR TILE, TILE AROUND THE BATHTUB? | | | ADDITIONAL INFORMATION IS REQUIRED. 107.2.1.2. | | | | | | 4) FLOOR INSULATION (FBC-B 2020) FOR TILE, STONE, | | | MARBLE, VINYL AND WOOD FLOORING ALL NEED TO HAVE HAD | | | THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE | | | FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS LISTED | | | UNDER EACH OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR | | | ASSEMBLY/ NO DROPPED CEILING: | | | PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR | | | TYPE II BUILDINGS SHOWING COMPLIANCE WITH: | | | | | | 4A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | | | 4B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS, | | | PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR | | | AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E | | | 90. | | | | | | 4C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2. | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 5) 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS A | | | BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALLS | | | AND CEILING PANELS IN SHOWER AREAS SHALL BE OF | | | MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN | | | ACCORDANCE WITH MANUFACTURER?S RECOMMENDATIONS. WATER | | | RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE | | | FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN | | | INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND | | | THE MANUFACTURE?S RECOMMENDATIONS. | | | | | | 6) 2020 FBC-B SHOWERS & TUBS 1210.3. SHOWER | | | COMPARTMENTS AND BATHTUBS WITH INSTALLED SHOWER HEADS | | | SHALL BE FINISHED WITH A NONABSORBENT SURFACE TO A | | | HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET. | | | | | | 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | | RETIRED. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-05-25 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-05-25 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2021-05-25 09:44:43 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21050159 | | | ADD: 1501 S. FLAGLER DR. # 3H | | | CONT: FERRER & ASSOC. OF FLORIDA | | | TEL: 561-936-1998 | | | E-MAIL: FERRERFLA#AOL.COM | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. MAY 25TH/ 2021 | | | ACTION: DENIED | | | | | | 1) THE SUBMITTED SHEETS THE OVERALL 3RD FLOOR PLAN AND | | | THE APARTMENT FLOOR PLAN BOTH ARE COPIES OF PLANS | | | DESIGNED BY PACHER & CITRON ARCHITECTS. COPIES OF THESE | | | PLANS ARE NOT VALID PLANS WITHOUT THE PERMISSION OF THE | | | DESIGNERS OF RECORD, PLANS ARE COPY-RIGHTED. THEY CAN | | | NOT BE TURNED IN WITHOUT THE ORIGINAL SIGNATURE AND | | | SEAL. FL ADMIN CODE 61G16.003(1) ARCHITECTS. PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS PREPARED BY | | | THE DESIGN PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN | | | PROFESSIONAL AFFIXED TO THE DOCUMENT. | | | | | | 2) THE SUBMITTED KITCHEN FLOOR PLAN DOES NOT INDICATE | | | WHO THE AUTHOR OF THIS PLAN IS? CERTIFICATION BY | | | CONTRACTOR. 107.3.4.3. THE CONTRACTOR (QUALIFIER) THAT | | | CREATED / DREW THE SET OF PLANS WILL NEED TO IDENTIFY | | | THEMSELVES AS THE AUTHOR OF THE PLANS. PLEASE PRINT | | | YOUR NAME, SIGN YOUR NAME AND LICENSE NUMBER FOR THE | | | TRADE YOU ARE LICENSED IN AND PLANS DRAWN. | | | | | | 3) THE PERMIT APPLICATION UNDER THE DESCRIPTION OF WORK | | | LISTED FLOORING, BUT ON THE KITCHEN FLOOR PLAN THERE IS | | | NO MENTION OF FLOORING, THE SCOPE OF WORK FOR THE | | | BATHROOMS IS NOT CLEAR SINCE THE APPLICATION STATES | | | PLURAL VANITIES, AND TILE. WHAT DOES THE TILE INCLUDE | | | BATHROOM FLOOR TILE, TILE AROUND THE BATHTUB? | | | ADDITIONAL INFORMATION IS REQUIRED. 107.2.1.2. | | | | | | 4) FLOOR INSULATION (FBC-B 2020) FOR TILE, STONE, | | | MARBLE, VINYL AND WOOD FLOORING ALL NEED TO HAVE HAD | | | THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE | | | FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS LISTED | | | UNDER EACH OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR | | | ASSEMBLY/ NO DROPPED CEILING: | | | PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR | | | TYPE II BUILDINGS SHOWING COMPLIANCE WITH: | | | | | | 4A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | | | 4B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS, | | | PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR | | | AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E | | | 90. | | | | | | 4C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2. | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 5) 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS A | | | BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALLS | | | AND CEILING PANELS IN SHOWER AREAS SHALL BE OF | | | MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN | | | ACCORDANCE WITH MANUFACTURER?S RECOMMENDATIONS. WATER | | | RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE | | | FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN | | | INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND | | | THE MANUFACTURE?S RECOMMENDATIONS. | | | | | | 6) 2020 FBC-B SHOWERS & TUBS 1210.3. SHOWER | | | COMPARTMENTS AND BATHTUBS WITH INSTALLED SHOWER HEADS | | | SHALL BE FINISHED WITH A NONABSORBENT SURFACE TO A | | | HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET. | | | | | | 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | | RETIRED. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-29 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-29 |
Time |
12:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2021-06-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-24 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-24 |
Time |
17:43 |
Sent To |
|
|
| Notes |
| 2021-06-24 18:17:24 | ONLY A NEW PANEL IS BEING INSTALLED??? JLEAHY | | | | | | ANY ELECTRICAL WORK NEEDS TO BE SHOWN ON PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-06-03 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-06-03 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-06-03 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2021-06-03 10:14:35 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW: | | | | | | 1) FEEDER FROM EXISTING 100 AMPS MAIN BREAKER TO NEW | | | 100 AMPS PANEL IS SHOWN AS 3#2 AL. AMPACITY OF #2 AL IS | | | 90 AMPS AND AS PER NEC 240.4(B)(2) THE MAXIMUM | | | OVERCURRENT DEVICE | | | FOR THIS CONDUCTOR IS 90 AMPS (90 AMPS IS AN STANDARD | | | BREAKER SIZE). PLEASE INCREASE SIZE OF CONDUCTOR TO | | | COMPLY WITH NEC 240.4(B) | | | | | | ENRIQUE QUINONEZ PE | | | ELECTRICAL PLANS EXAMINER | | | DEVELOPMENT SERVICES | | | CITY OF WEST PAM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6746. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-05-18 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-18 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-05-18 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2021-05-18 15:20:14 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW: | | | | | | 1) PERMIT APPLICATION MENTIONS NEW ELECTRICAL PANEL | | | BEING INSTALLED. PLEASE SHOW ALL ELECTRICAL WORK BEING | | | DONE UNDER THIS PERMIT. | | | | | | 2) SUBMIT PARTIAL RISER DIAGRAM WITH FEEDERS TO NEW | | | PANEL, GROUNDING CONDUCTOR, ETC. | | | | | | 3) PLEASE SUBMIT ELECTRICAL PANEL SCHEDULE, PANEL | | | RATINGS, AIC RATING | | | | | | 4) DRAWINGS NEED TO HAVE THE NAME, SIGNATURE, AND | | | LICENSE NUMBER OF CONTRACTOR QUALIFIER. | | | | | | 5) ELECTRICAL SUB PERMIT REQUIRED | | | | | | ENRIQUE QUINONEZ PE | | | ELECTRICAL PLANS EXAMINER | | | DEVELOPMENT SERVICES | | | CITY OF WEST PAM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6746. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-06-02 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-06-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-06-02 |
Time |
10:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-05-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-05-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-05-06 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2021-05-06 11:01:22 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE ARE INDICATIONS OF FLOOINGR/TILE WORK; | | | HOWEVER, THERE ARE NO INDICATIONS OF THE TYPE OF | | | FLOORING/TILE NOR SOUND UNDERLAYMENT, I.E PRODUCT | | | SHEETS. | | | | | | PER NFPA 101, CH 30 | | | | | | 30.3.3.3 INTERIOR FLOOR FINISH. | | | 30.3.3.3.1 INTERIOR FLOOR FINISH SHALL COMPLY WITH | | | SECTION 10.2. | | | | | | 30.3.3.3.3 INTERIOR FLOOR FINISH SHALL COMPLY WITH | | | 10.2.7.1 OR | | | 10.2.7.2, AS APPLICABLE | | | | | | 10.2.1.1 CLASSIFICATION OF INTERIOR FINISH MATERIALS | | | SHALL BE IN | | | ACCORDANCE WITH TESTS MADE UNDER CONDITIONS SIMULATING | | | ACTUAL | | | INSTALLATIONS, PROVIDED THAT THE AUTHORITY HAVING | | | JURISDICTION IS | | | PERMITTED TO ESTABLISH THE CLASSIFICATION OF ANY | | | MATERIAL FOR WHICH | | | CLASSIFICATION BY A STANDARD TEST IS NOT AVAILABLE, | | | UNLESS OTHERWISE | | | PROVIDED IN 10.2.1.2 OR 10.2.1.4. | | | 10.2.1.2 THE PROVISIONS OF 10.2.1.1 SHALL NOT APPLY TO | | | MATERIALS HAVING | | | A TOTAL THICKNESS OF LESS THAN 1?28 IN. (0.9 MM) THAT | | | ARE APPLIED DIRECTLY | | | TO THE SURFACE OF WALLS AND CEILINGS WHERE BOTH OF THE | | | FOLLOWING | | | CONDITIONS ARE MET: | | | (1) THE WALL OR CEILING SURFACE IS A NONCOMBUSTIBLE OR | | | LIMITED COMBUSTIBLE | | | MATERIAL. | | | (2) THE MATERIALS APPLIED MEET THE REQUIREMENTS OF | | | CLASS A INTERIOR | | | WALL OR CEILING FINISH WHEN TESTED IN ACCORDANCE WITH | | | 10.2.3, | | | USING FIBER CEMENT BOARD AS THE SUBSTRATE MATERIAL. | | | | | | 10.2.7* INTERIOR FLOOR FINISH TESTING AND | | | CLASSIFICATION. | | | 10.2.7.1* CARPET AND CARPET LIKE INTERIOR FLOOR | | | FINISHES SHALL | | | COMPLY WITH ASTM D 2859, STANDARD TEST METHOD FOR | | | IGNITION | | | CHARACTERISTICS OF FINISHED TEXTILE FLOOR COVERING | | | MATERIALS. | | | 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH | | | 10.2.2.2 | | | ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL | | | HAVE A | | | MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2. | | | | | | 10.2.7.4 INTERIOR FLOOR FINISHES SHALL BE GROUPED IN | | | THE CLASSES SPECIFIED | | | IN 10.2.7.4.1 AND 10.2.7.4.2 IN ACCORDANCE WITH THE | | | CRITICAL RADIANT FLUX | | | REQUIREMENTS. | | | 10.2.7.4.1 CLASS I INTERIOR FLOOR FINISH. CLASS I | | | INTERIOR FLOOR FINISH | | | SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN | | | 0.45 W/CM2, AS DETERMINED | | | BY THE TEST DESCRIBED IN 10.2.7.3. | | | 10.2.7.4.2 CLASS II INTERIOR FLOOR FINISH. CLASS II | | | INTERIOR FLOOR FINISH | | | SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN | | | 0.22 W/CM2, BUT LESS | | | THAN 0.45 W/CM2, AS DETERMINED BY THE TEST DESCRIBED IN | | | 10.2.7.3. | | | | | | PLEASE REVIEW AND PROVIDE SPEC SHEETS. | | | | | | | | | 2) THERE ARE INDICATIONS OF KITCHEN CABINET | | | REPLACEMENT; HOWEVER, IT IS UNCLEAR OF POSSIBLE | | | RECONFIGURATION AND NEW WAL/CEILING WORK. | | | | | | PLEASE PROVIDE CLARIFICATIONS OF WHAT, IF ANY, IS NEW | | | WALL OR CEILING WORK. | | | | | | PLEASE BE ADVISED, ANY WORK INVOLVING FIRE | | | SPRINKLERS/FIRE ALARM SYSTEMS OR EQUIPMENT SHALL BE | | | DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | FIRE SPRINKLERS AND FIRE ALARM EQUIPMENT SHALL BE | | | PROTECTED FROM PAINTING OR DAMAGE. | | | | | | THE FIRE SPRINKLER/FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO AND RECONSTRUCTION. | | | | | | PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT AND ENSURE | | | COMPLIANCE. | | | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-29 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-29 |
Time |
12:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-06-25 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-06-25 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-06-25 |
Time |
08:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-06-29 |
|
|
Cont ID |
|
| Sent By |
ccarvaja |
Date |
2021-06-29 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
ccarvaja |
Date |
2021-06-17 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-06-09 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-05-27 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-05-25 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-05-05 |
Time |
12:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-05-25 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-05-25 |
Time |
09:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2021-06-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-03 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-03 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2021-06-03 11:06:25 | CONTRACTOR STATED NO MECHANICAL WORK INVOLVED WITH THE | | | PROJECT. JLEAHY |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-05-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-14 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-14 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2021-05-14 14:34:47 | IT IS NOT CLEAR IF THERE IS A HOOD ABOVE THE RANGE. | | | PLEAASE SHOW THE HOOD IF THERE IS ONE AND IF IT IS | | | DUCTED TO THE EXTERIOR OF THE BUILDING PLEASE SHOW | | | THAT. PLEASE SHOW THE CFM'S OF EXHAUST FOR THE HOOD IF | | | THERE IS ONE. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-06-08 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-06-08 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2021-06-01 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2021-06-08 16:32:25 | PLUMBING COMMENTTS: APPROVED | | | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT | | | | | | PLEASE NOTE THAT WHEN SCANNED DRAWINGS ARE SUBMITTED | | | WITH CONTRACTOR'S PRINTED NAME, SIGNATURE AND LICENSE | | | NUMBER IN ACCORDANCE WITH WPB FBC 107.2.1, A PAPER PLAN | | | WITH WET SIGNATURE SHALL BE PROVIDED TO THE BUILDING | | | DEPARTMENT FOR HARD RECORD FILE PRIOR TO ISSUANCE OF A | | | PERMIT. | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS | | | | | | 21050159 1501 S FLAGLER DR # 3H |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-05-17 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2021-05-17 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2021-05-17 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2021-05-17 11:36:20 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW | | | PLUMBING COMMENTS: DENIED | | | | | | NOTE: A PLUMBING SUB PERMIT IS REQUIRED. | | | | | | 1.SEE WPB FBC 107.3.4.3 CERTIFICATION BY CONTRACTOR. | | | PLEASE NOTE THE EXCEPTION TO ENGINEERED PLANS UNDER | | | 471.003(H) ELECTRICAL/ PLUMBING/ MECHANICAL, | | | 481.229(1)(C) (BUILDING) REQUIRES THE CONTRACTOR FOR | | | THAT TRADE THAT WILL BE LICENSED IN THAT TRADE, WILL | | | ALSO BE THE CONTRACTOR THAT DESIGNS THE SYSTEM UNDER | | | THAT TRADE. THE CONTRACTOR (QUALIFIER) THAT CREATED / | | | DRAWN THE SET OF PLANS WILL NEED TO IDENTIFY THEMSELVES | | | AS THE AUTHOR OF THE PLANS. PLEASE PRINT YOUR NAME, | | | SIGN YOUR NAME AND LICENSE NUMBER FOR THE TRADE YOU ARE | | | LICENSED IN AND PLANS DRAWN. FOR EACH TRADE THE | | | CONTRACTOR RESPONSIBLE FOR THE DESIGN UNDER THE TRADE | | | LICENSED IN MUST PRINT THEIR NAME, SIGN THEIR NAME AND | | | LICENSE NUMBER. | | | | | | 1A.PER WPB FBC 107.2.1, PROVIDE A SEPARATE PLUMBING | | | PLAN IN THE FORM OF THE ORIGINAL 003 APARTMENT FLOOR | | | PLAN. NOTE ON THE PLAN THE FIXTURES AFFECTED AND | | | DESCRIBE THE WORK BEING DONE (I.E. REMOVE EXISTING | | | KITCHEN SINK AND DISHWASHER. INSTALL NEW IN SAME | | | APPROXIMATE LOCATIONS. CONNECT TO EXISTING PLUMBING). | | | CONTRACTOR RESPONSIBLE FOR THE DESIGN UNDER THE TRADE | | | LICENSED IN MUST PRINT THEIR NAME, SIGN THEIR NAME AND | | | LICENSE NUMBER. | | | | | | 1B.PER FBC PL 604.9, WATER HAMMER ARRESTORS ARE | | | REQUIRED FOR THE REFRIGERATOR ICE LINE WATER SUPPLY AND | | | FOR THE DISHWASHER HOT WATER SUPPLY. | | | | | | PLEASE NOTE THAT WHEN SCANNED DRAWINGS ARE SUBMITTED | | | WITH CONTRACTOR'S PRINTED NAME, SIGNATURE AND LICENSE | | | NUMBER IN ACCORDANCE WITH WPB FBC 107.2.1, A PAPER PLAN | | | WITH WET SIGNATURE SHALL BE PROVIDED TO THE BUILDING | | | DEPARTMENT FOR HARD RECORD FILE PRIOR TO ISSUANCE OF A | | | PERMIT. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2021-05-28 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-28 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-05-28 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2021-05-06 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-06 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-06 |
Time |
06:54 |
Sent To |
|
|
| Notes |
|
|