| Plan Review Stops For Permit 21050080 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-01 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-01 |
Time |
14:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-12 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-12 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-08-30 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-08-30 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2021-08-30 16:46:29 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. PROVIDE A COPY OF THE MOST CURRENT BOUNDRY LINE | | | SURVEY. (NOT CORRECTED) | | | | | | 2. PROVIDE A SITE PLAN. ? DRAINAGE/SURVEY (NOT | | | CORRECTED) | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | | | | 3. PROVIDE A PROJECT DATA TABLE. SHOW EXISTING SQUARE | | | FEET AND NEW SQUARE FEET. (NOT CORRECTED) | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 4. REF. PLAN PAGE S-1. DESIGN CONSIDERATION TABLE | | | REFERENCES ASCE 7-10. ASCE 7-10 HAS EXPIRED. CORRECTED | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4) OR ASCE 7-16. | | | | | | 5. PROVIDE A ROOF FRAMING PLAN. (NOT CORRECTED) | | | PROVIDE DESIGN PRESSURES PER FIGURE R301.2(7) COMPONENT | | | AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | PROVIDE ROOF SHEATHING FASTENER SCHEDULE | | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | R803.2.3.1SHEATHING FASTENINGS. | | | WOOD STRUCTURAL PANEL SHEATHING SHALL BE FASTENED TO | | | ROOF FRAMING IN ACCORDANCE WITH TABLE R803.2.3.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-10 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-10 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2021-06-10 14:07:09 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE A COPY OF THE MOST CURRENT BOUNDRY LINE | | | SURVEY. | | | 2. PROVIDE A SITE PLAN. ? DRAINAGE/SURVEY | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | | | | 3. PROVIDE AN EXISTING FLOOR PLAN. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. PROVIDE A PROJECT DATA TABLE. SHOW EXISTING SQUARE | | | FEET AND NEW SQUARE FEET. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 4. REF. PLAN PAGE S-1. DESIGN CONSIDERATION TABLE | | | REFERENCES ASCE 7-10. ASCE 7-10 HAS EXPIRED. | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4) OR ASCE 7-16. | | | | | | 5. PROVIDE A ROOF FRAMING PLAN. | | | PROVIDE DESIGN PRESSURES PER FIGURE R301.2(7) COMPONENT | | | AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | PROVIDE ROOF SHEATHING FASTENER SCHEDULE | | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | R803.2.3.1SHEATHING FASTENINGS. | | | WOOD STRUCTURAL PANEL SHEATHING SHALL BE FASTENED TO | | | ROOF FRAMING IN ACCORDANCE WITH TABLE R803.2.3.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-01 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-01 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-08-30 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-08-30 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-05-18 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-18 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-05-18 |
Time |
09:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-10-15 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-10-15 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-10-15 |
Time |
08:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-08-31 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-08-31 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-08-31 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2021-08-31 09:50:16 | SEE PREVIOUS NOTES |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-05-18 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2021-05-18 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2021-05-17 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2021-05-18 16:48:50 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | 1. PROVIDE A SURVEY INDICATING THE SETBACKS OF THE DECK | | | AND BATHROOM ADDITION FROM THE PROPERTY LINES. | | | 2. A HORIZONTAL ROLLER WINDOW WILL NOT BE PERMITTED. | | | STAFF RECOMMENDS OPENING THE ENCLOSED PORCH BACK UP. | | | 3. PROVIDE EXISTING ELEVATIONS. THIS CAN BE ACHIEVED | | | USING MULTIPLE PHOTOS (IN COLOR) OF THE ELEVATION. | | | 4. INDICATE HEIGHT OF PROPOSED DECK. | | | 5. W12 IS A WOOD WINDOW. THIS WINDOW SHALL BE RETAINED. | | | STAFF RECOMMENDS RESTORING THIS WINDOW. | | | 6. PROVIDE A MUNTIN PROFILE FOR THE ES WINDOWS PRODUCT. | | | 7. EXPAND THE WINDOW AND DOOR SCHEDULE TO INCLUDE | | | INFORMATION AS INDICATED IN THE WINDOW PERMIT | | | APPLICATION EXAMPLE. PLEASE EMAIL STAFF AT | | | [email protected] TO REQUEST THIS EXAMPLE. AT | | | MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOWS AND | | | THE PROPOSED WINDOWS - MATERIAL, EXTERIOR FRAME COLOR, | | | GLASS GLAZING, LITE PATTERN, MUNTIN PROFILE AND MULLION | | | WIDTH. A PHOTO OF EACH ELEVATION WITH EACH WINDOW | | | MARKED AND CLEARLY VISIBLE. IF SHUTTERS OR SIMILAR | | | VISUAL OBSTRUCTION EXISTS, MULTIPLE PHOTOS MAY BE | | | REQUIRED. INCLUDE THE ORDER DETAIL QUOTE/DETAILED | | | CUSTOMER PROPOSAL. | | | 8. PROVIDE INFORMATION REGARDING THE SIDING FOR THE | | | ADDITION. | | | 9. PROVIDE A PROJECT DATA TABLE INDICATING THE EXISTING | | | BUILDINGS SQUARE FOOTAGE, PROPOSED BUILDINGS SQUARE | | | FOOTAGE, AND LOT SIZE. | | | | | | ADDITIONAL COMMENTS MAY BE NECESSARY ONCE ADDITIONAL | | | INFORMATION HAS BEEN PROVIDED. | | | | | | PROPOSED CONDITIONS, SUBJECT TO CHANGE. ENSURE ALL | | | PROPOSED PRODUCTS CAN COMPLY WITH THESE CONDITIONS. | | | 1. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE | | | ORIGINAL WINDOW FRAME OPENING (X-AXIS AND Y-AXIS) AND | | | MATCH THE LOCATION/DEPTH (Z-AXIS) OF THE ORIGINAL | | | WINDOWS. | | | | | | CLARIFICATION: | | | THE INSTALLATION OF THE TOP SASH SHALL BE LOCATED | | | ROUGHLY AT THE SAME POSITION OF THE TOP SASH OF THE | | | WOOD WINDOWS. | | | | | | 2. THE EXISTING MULLION SHALL REMAIN OR BE REPLACED | | | WITH A MULLION OF MATCHING WIDTH AND PLACEMENT. | | | 3. ALL STREET OR SIDEWALK FACING GLASS SHALL BE CLEAR. | | | ALL NON-STREET FACING GLASS SHALL BE CLEAR OR CLEAR | | | WITH LOW-E COATING. NO TINT. OBSCURED TEXTURED GLASS | | | MAY BE USED ON NON-STREET FACING BATHROOMS ONLY. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-11-01 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-10-28 |
Time |
10:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-10-18 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-10-18 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-10-06 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-10 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-10 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-11-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-11-08 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-10-28 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2021-11-08 12:43:52 | RECEIPT MU-2021-053051 - $0.00 FEES DUE | | 2021-11-01 14:13:41 | 10/28/21 EMAILED IMPACT FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-10 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-10 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2021-06-10 13:32:24 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-10-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-29 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-29 |
Time |
08:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-08-30 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-08-30 |
Time |
15:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2021-08-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-08-27 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-08-27 |
Time |
10:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-08-30 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-08-30 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-05-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-05-17 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-05-17 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-08-30 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-08-30 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2021-08-30 16:38:01 | PROVISO ON PG S-1: A SEPERATE ROOFING PERMIT IS | | | REQUIRED. CT |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-10 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-10 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2021-06-10 13:34:25 | PLAN REVIEW ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOFING PERMIT REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2. PROVIDE DESIGN PRESSURES PER FIGURE R301.2(7) | | | COMPONENT AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | | | | 3. PROVIDE ROOF SHEATHING FASTENER SCHEDULE | | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | | | | 4. PROVIDE PRODUCT APPROVALS | | | | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-10-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-12 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-12 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-08-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-08-30 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-08-30 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-10 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-10 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2021-10-28 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2021-10-28 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2021-10-28 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2021-10-15 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-10-15 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-10-15 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2021-10-15 08:26:50 | SETBACK OF DECK STILL NOT CLEARLY DEMARCATED AS 5' OFF | | | PROPERTY LINE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-08-31 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-08-31 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-08-31 |
Time |
09:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-05-18 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2021-05-18 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2021-05-17 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2021-05-18 16:48:32 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | 1. PROVIDE A SURVEY INDICATING THE SETBACKS OF THE DECK | | | AND BATHROOM ADDITION FROM THE PROPERTY LINES. | | | 2. A HORIZONTAL ROLLER WINDOW WILL NOT BE PERMITTED. | | | STAFF RECOMMENDS OPENING THE ENCLOSED PORCH BACK UP. | | | 3. PROVIDE EXISTING ELEVATIONS. THIS CAN BE ACHIEVED | | | USING MULTIPLE PHOTOS (IN COLOR) OF THE ELEVATION. | | | 4. INDICATE HEIGHT OF PROPOSED DECK. | | | 5. W12 IS A WOOD WINDOW. THIS WINDOW SHALL BE RETAINED. | | | STAFF RECOMMENDS RESTORING THIS WINDOW. | | | 6. PROVIDE A MUNTIN PROFILE FOR THE ES WINDOWS PRODUCT. | | | 7. EXPAND THE WINDOW AND DOOR SCHEDULE TO INCLUDE | | | INFORMATION AS INDICATED IN THE WINDOW PERMIT | | | APPLICATION EXAMPLE. PLEASE EMAIL STAFF AT | | | [email protected] TO REQUEST THIS EXAMPLE. AT | | | MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOWS AND | | | THE PROPOSED WINDOWS - MATERIAL, EXTERIOR FRAME COLOR, | | | GLASS GLAZING, LITE PATTERN, MUNTIN PROFILE AND MULLION | | | WIDTH. A PHOTO OF EACH ELEVATION WITH EACH WINDOW | | | MARKED AND CLEARLY VISIBLE. IF SHUTTERS OR SIMILAR | | | VISUAL OBSTRUCTION EXISTS, MULTIPLE PHOTOS MAY BE | | | REQUIRED. INCLUDE THE ORDER DETAIL QUOTE/DETAILED | | | CUSTOMER PROPOSAL. | | | 8. PROVIDE INFORMATION REGARDING THE SIDING FOR THE | | | ADDITION. | | | 9. PROVIDE A PROJECT DATA TABLE INDICATING THE EXISTING | | | BUILDINGS SQUARE FOOTAGE, PROPOSED BUILDINGS SQUARE | | | FOOTAGE, AND LOT SIZE. | | | | | | ADDITIONAL COMMENTS MAY BE NECESSARY ONCE ADDITIONAL | | | INFORMATION HAS BEEN PROVIDED. | | | | | | PROPOSED CONDITIONS, SUBJECT TO CHANGE. ENSURE ALL | | | PROPOSED PRODUCTS CAN COMPLY WITH THESE CONDITIONS. | | | 1. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE | | | ORIGINAL WINDOW FRAME OPENING (X-AXIS AND Y-AXIS) AND | | | MATCH THE LOCATION/DEPTH (Z-AXIS) OF THE ORIGINAL | | | WINDOWS. | | | | | | CLARIFICATION: | | | THE INSTALLATION OF THE TOP SASH SHALL BE LOCATED | | | ROUGHLY AT THE SAME POSITION OF THE TOP SASH OF THE | | | WOOD WINDOWS. | | | | | | 2. THE EXISTING MULLION SHALL REMAIN OR BE REPLACED | | | WITH A MULLION OF MATCHING WIDTH AND PLACEMENT. | | | 3. ALL STREET OR SIDEWALK FACING GLASS SHALL BE CLEAR. | | | ALL NON-STREET FACING GLASS SHALL BE CLEAR OR CLEAR | | | WITH LOW-E COATING. NO TINT. OBSCURED TEXTURED GLASS | | | MAY BE USED ON NON-STREET FACING BATHROOMS ONLY. | | | |
|
|