Plan Review Details - Permit 21041659
| Plan Review Stops For Permit 21041659 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-25 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-05-25 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-05-07 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-07 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-05-07 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2021-05-07 11:12:57 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | REVIEW STATUS: FAILED. SEE NEW COMMENTS BELOW | | | | | | 1) NEW RISER ALSO SHOWS A CHANGE IN THE SIZE OF | | | CONDUCTOR FROM METER TO 200 AMPS SE RATED ATS AMD TO | | | 200 AMPS PANEL. | | | NEW DIAGRAM NOW SHOWS A #2/0 CONDUCTOR INSTEAD OF #3/0. | | | THE 2/0 IS RATED FOR ONLY 175 AMPS AND PER NEC | | | 310.15(B)(7) THE AMPACITY | | | OF THESE CONDUCTORS CANNOT BE DERATED SINCE THEY DO NOT | | | SUPPLY THE ENTIRE LOAD TO THE HOUSE. MINIMUM SIZE SHALL | | | BE #3/0 CU AS SPECIFIED IN THE | | | ORIGINAL RISER DIAGRAM. | | | | | | SINCERELY, | | | | | | ENRIQUE QUINONEZ PE | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-25 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-05-24 |
Time |
12:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-05-07 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-07 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-04-30 |
Time |
11:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2021-05-07 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-07 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-05-07 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |