| Plan Review Stops For Permit 21041469 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-07-06 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-07-06 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-07-06 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-06-23 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-06-23 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2021-06-23 12:35:31 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | | APPROVALS/NOA'S FOR THE PROPOSED ROOF UNDERLAYMENT | | | (JOINT TAPE/STRIPS) TO BE USED. INCLUDE COVER PAGE, | | | EVALUATION REPORTS AND INSTALLATION INSTRUCTIONS FOR | | | SYSTEM USED. ALL APPLICABLE DETAILS AND ATTACHMENTS | | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | | DRAWINGS. DETAILS AND ATTACHMENTS NOT SPECIFICALLY | | | COVERED IN PRODUCT APPROVALS WILL NEED SITE-SPECIFIC | | | ENGINEERING. (OPTIONS FL12328-R9, FL2569-R33 ETC.) | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-06-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-06-11 |
Time |
19:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-06-11 |
Time |
19:56 |
Sent To |
|
|
| Notes |
| 2021-06-11 19:57:45 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | FROM PREVIOUS LIST: | | | | | | 2. FBC R 905.1.1 ASPHALT SHINGLE, METAL, MINERAL | | | SURFACE, SLATE AND SLATE-TYPE ROOFING MUST COMPLY WITH | | | NEW 2020 BUILDING CODE UNDERLAYMENT REQUIREMENTS. | | | | | | A DOCUMENT LISTING THE METHODS OF COMPLIANCE WAS | | | UPLOADED TO PROJECTDOX. YOU MAY USE THAT FORM TO | | | INDICATE WHICH METHOD YOU WISH TO UTILIZE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-05-06 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-05-06 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-05-06 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2021-05-06 08:24:16 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX | | | | | | 1. FBC B 107.2.1. CITY OF WEST PALM BEACH IS NOT | | | LOCATED IN A HVHZ AND HAS NOT ADOPTED RAS 150. GENERAL | | | LIMITATION #7 IS SPECIFICALLY REFERRED TO IN THIS NOA. | | | PERIMETER AND CORNER AREAS SHALL COMPLY WITH THE | | | ENHANCED UPLIFT PRESSURE REQUIREMENTS OF THESE AREAS. | | | FASTENER DENSITIES SHALL BE INCREASED FOR BOTH | | | INSULATION AND BASE SHEET AS CALCULATED IN COMPLIANCE | | | WITH ROOFING APPLICATION STANDARD RAS 117. CALCULATIONS | | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER, REGISTERED ARCHITECT, OR | | | REGISTERED ROOF CONSULTANT. PROVIDE A COMPLETE SET. | | | 2. FBC R 905.1.1 ASPHALT SHINGLE, METAL, MINERAL | | | SURFACE, SLATE AND SLATE-TYPE ROOFING MUST COMPLY WITH | | | NEW 2020 BUILDING CODE UNDERLAYMENT REQUIREMENTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-06-23 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-06-22 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-06-11 |
Time |
19:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-06-10 |
Time |
08:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-05-06 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-05-06 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-05-05 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-10 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-10 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2021-06-10 15:53:11 | ORIGINAL SIGNED AND SEALED PAPER DOCUMENTS ROUTED TO | | | STORAGE. ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-05-06 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-05-06 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-05-06 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2021-05-06 08:25:21 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED | | | PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | PETER VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6673. | | | |
|
|