Plan Review Details - Permit 21041410
Plan Review Stops For Permit 21041410
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-06-04 Cont ID  
Sent By rmcphers Date 2021-06-04 Time 15:46 Rev Time 0.00
Received By rmcphers Date 2021-06-04 Time 15:46 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-05-11 Cont ID  
Sent By rmcphers Date 2021-05-11 Time 15:42 Rev Time 0.00
Received By rmcphers Date 2021-05-11 Time 15:42 Sent To  
Notes
2021-05-11 15:43:11PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-06-04 Cont ID  
Sent By rmcphers Date 2021-06-04 Time 15:46 Rev Time 0.00
Received By rmcphers Date 2021-06-04 Time 15:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-05-11 Cont ID  
Sent By rmcphers Date 2021-05-11 Time 15:42 Rev Time 0.00
Received By rmcphers Date 2021-05-11 Time 15:23 Sent To  
Notes
2021-05-11 15:42:01CONDO REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE PROPOSED SHOWER WALL FINISH FBC
 1210.2.3
 2) PLEASE SHOW THE LOCATION OF THE NEW FLOORING ON THE
 FLOOR PLAN.
 3) THE FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED:
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS
 ATTACHED TO THE FLOORING)
  
 4) . PLEASE EMAIL ME THE PROPOSED TEST REPORTS TO
 VERIFY BEFORE RESUBMITTING TO PROJECTDOX (
 [email protected] )
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-05-25 Cont ID  
Sent By jleahy Date 2021-05-25 Time 19:28 Rev Time 0.00
Received By jleahy Date 2021-05-25 Time 19:25 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-05-10 Cont ID  
Sent By jleahy Date 2021-05-10 Time 06:22 Rev Time 0.00
Received By jleahy Date 2021-05-07 Time 07:18 Sent To  
Notes
2021-05-10 06:24:36ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NO ELECTRICAL WORK INDICATED ON PLAN. PLEASE INDICATE
 WHAT IS TO BE REPLACED, LIGHTS, SWITCHES, OUTLETS

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-05-07 Cont ID  
Sent By pleduc Date 2021-05-07 Time   Rev Time 0.00
Received By pleduc Date 2021-05-07 Time 09:15 Sent To  
Notes
2021-05-07 09:20:44FIRE PROVISO:
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
  
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
  
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-06-04 Cont ID  
Sent By rmcphers Date 2021-06-04 Time 15:48 Rev Time 0.00
Received By rmcphers Date 2021-05-24 Time 11:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-11 Cont ID  
Sent By rmcphers Date 2021-05-11 Time 15:43 Rev Time 0.00
Received By rmcphers Date 2021-04-27 Time 07:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2021-05-07 Cont ID  
Sent By medwards Date 2021-05-07 Time 06:24 Rev Time 0.00
Received By medwards Date 2021-05-07 Time 06:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-05-26 Cont ID  
Sent By ccole Date 2021-05-26 Time 13:01 Rev Time 0.00
Received By ccole Date 2021-05-26 Time 12:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-05-07 Cont ID  
Sent By ccole Date 2021-05-07 Time 12:20 Rev Time 0.00
Received By ccole Date 2021-05-07 Time 09:03 Sent To  
Notes
2021-05-07 12:20:581ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21041410
 5/7/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P.1: PROVIDE SHOWER PAN DETAILS- SECTIONS
 421.5.1 & 421.5.2 FBC P.
  
 2) SHEET P.1: FAIR HOUSING ACCESSIBILITY GUIDELINES:
 BECAUSE THE BUILDING WAS CONSTRUCTED IN ACCORDANCE WITH
 THE ACCESSIBILITY REQUIREMENTS OF THE FAIR HOUSING ACT
 AND THE DESIGN GUIDELINES FOR USABLE BATHROOMS IN
 DWELLING UNITS, THE ALTERATIONS THAT ARE PROPOSED IN
 THE BATHROOMS SHALL ALSO BE IN COMPLIANCE WITH THE FAIR
 HOUSING ACT. THE FAIR HOUSING ACCESSIBILITY GUIDELINES
 ARE INCLUDED IN THE FLORIDA ACCESSIBILITY CODE- 2020
 SEVENTH EDITION. REFER TO REQUIRMENT 7 USUABLE KITCHENS
 AND BATHROOMS AND PAGE 7.33 IN THE FAIR HOUSING ACT
 DESIGN MANUAL.
 BASED ON THE DRAWING IT IS NOT CLEAR IF USABLE BATHROOM
 SPECIFICATION TYPE A OR B WAS CHOSEN AS THE ORIGINAL
 DESIGN HOWEVER BECAUSE FIXTURES IN THE MASTER AND GUEST
 BATHS ARE BEING REPLACED, IT IS NECESSARY TO DETERMINE
 WHICH TYPE SO THAT THE REPLACED FIXTURES CAN REMAIN IN
 COMPLIANCE. PLEASE REFER TO PAGES 7.34- 7.39 FOR
 EXPLANATORY INFORMATION ON SPECIFICATION A & B.
 THE DRAWINGS APPEAR TO INDICATE NO CHANGES TO THE
 LOCATIONS OF THE WATER CLOSETS. LAVATORY AND BATHTUB
 FIXTURES AND FAUCET LOCATIONS. PLEASE REFER TO:
  
 PAGES- 7.40-7.46 WATER CLOSET CLEAR FLOOR SPACES.
 PAGES- 7.47- 7.52: LAVATORY AND VANITY CLEAR FLOOR AND
 KNEE AND TOE CLEARANCES.
 PAGES- 7.53- 7.55: BATHTUB CLEAR FLOOR SPACE AND
 CONTROL LOCATIONS.
  
 CONCERNING THE SHOWERS PLEASE SEE PAGES 7.56- 7.59 OF
 THE MANUAL. COMPLIANCES FOR THE SHOWERS ARE ALSO
 DEPENDENT ON DETERMINATION OF WHICH SPECIFICATION HAS
 BEEN CHOSEN- A OR B. IN SPECIFICATION A BATHROOMS WHERE
 ALL FIXTURES MUST MEET THE GUIDELINES, IF THE ROOM IS
 EQUIPPED WITH A BATHTUB AND SEPARATE SHOWER, BOTH
 FIXTURES MUST BE PROVIDED WITH THE CLEAR FLOOR SPACE.
 IN SPECIFICATION B BATHROOMS, ONLY ONE BATHING FIXTURE
 MUST BE PROVIDED WITH THE CLEAR FLOOR SPACE. PLEASE SEE
 THE FIGURES CONTAINED IN PAGES 7.56- 7.59 FOR CLEAR
 FLOOR SPACE POSITIONING AND CONTROLS LOCATIONS.
  
 A) P.1: SHOW THE CLEAR FLOOR SPACE DIAGRAMS AND
 DIMENSIONS FOR THE BATHROOM FIXTURES BASED ON EITHER
 SPECIFICATION A OR B. PLEASE INCLUDE KNEE AND TOE
 B) P.1: SHOW THE LOCATIONS OF THE SHOWER CONTROLS.
 C) P.1: PROVIDE GRAB BAR REINFORCEMENT DETAILS FOR THE
 TOILETS, BATHTUB AND SHOWERS AS REQUIRED BY EITHER
 SPECIFICATION A OR B. GRAB BAR REINFORCEMENT LOCATIONS
 CAN BE FOUND ON PAGES 6.3- 6.16. REINFORCEMENTS FOR
 SHOWER SEATS (WHERE REQUIRED) ARE SHOWN ON PAGE 6.13.
  
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND
 DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE
 A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE
 ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET
 THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 SO REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN,
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE FAIR HOUSING AFFIDAVIT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-06-04 Cont ID  
Sent By rmcphers Date 2021-06-04 Time 15:47 Rev Time 0.00
Received By rmcphers Date 2021-06-04 Time 15:47 Sent To  
Notes
2021-06-04 15:47:56DRAWINGS ARE SIGNED BY THE DESIGNER

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-05-07 Cont ID  
Sent By medwards Date 2021-05-07 Time 06:26 Rev Time 0.00
Received By medwards Date 2021-05-07 Time 06:26 Sent To  
Notes
***NONE***