Plan Review Details - Permit 21041405
Plan Review Stops For Permit 21041405
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-05-14 Cont ID  
Sent By cpuell Date 2021-05-14 Time 14:53 Rev Time 0.00
Received By cpuell Date 2021-05-14 Time 14:53 Sent To  
Notes
2021-07-02 15:24:05SUITES 100 & 102 MERGED TO CREATE 101. SUITES 202 & 204
 MERGED TO CREATE 203.
2021-05-14 14:53:47SUITE 100 IDENTIFIED

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2021-07-15 Cont ID  
Sent By jwitmer Date 2021-07-15 Time 19:00 Rev Time 0.00
Received By jwitmer Date 2021-07-15 Time 18:59 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-05-18 Cont ID  
Sent By jwitmer Date 2021-05-18 Time 15:59 Rev Time 0.00
Received By jwitmer Date 2021-05-18 Time 11:31 Sent To  
Notes
2021-05-18 15:56:49COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-08-24 Cont ID  
Sent By jwitmer Date 2021-08-24 Time 10:16 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-07-16 Cont ID  
Sent By jwitmer Date 2021-07-16 Time 14:27 Rev Time 0.00
Received By jwitmer Date 2021-07-15 Time 18:59 Sent To  
Notes
2021-07-16 14:25:54WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21041405
 ADD: 5325 GREENWOOD AVE. SUITE 100
 CONT: BLACK DIAMOND GENERAL CONTRACTING
 TEL: 561-746-3452
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: FRI. JULY 16TH/2021
 ACTION: DENIED
  
 1) NEW COMMENT. SHEET LS 102 THE 2ND FLOOR. DELTA 1
 PROVIDE ALLOWANCE TO UPGRADE ELECTRONIC DRINKING
 FOUNTAIN SHOULD IT NOT MEET CURRENT ACCESSIBILITY
 REQUIREMENTS; PROVIDE OPTION FOR BOTTLE FILLER. THE
 REQUIREMENTS FOR DRINKING FOUNTAINS IN THE 2020
 FBC-ACCESSIBILITY CODE FOR SECTION 211.2 HAVE BEEN MET
 ON FLOOR 1. IN THE 2020 FBC-PLUMBING CODE SECTION 403.5
 ALLOWS THE TRAVEL DISTANCE OF 500 FT. AND NOT MORE THAN
 ONE STORY ABOVE OR BELOW THE STORY WITH COMPLIANT
 DRINKING FOUNTAINS (FBC-ACCESS. CODE) SECTION 211.2. IN
 THE 2020 FBC-PLUMBING CODE SECTION 410.4 ALLOWS
 SUBSTITUTION PLEASE PROVIDE THE SPEC FOR THE DRINKING
 FOUNTAIN COMBO BOTTLE FILLER FOR REVIEW. I?VE SPOKEN TO
 THE PLUMBING PLANS EXAMINER AT LENGTH ON THIS SUBJECT.
 IT IS AGREED THAT BOTH BUILDING PLANS EXAMINER JIM
 WITMER AND PLUMBING PLANS EXAMINER CHRIS COLE WILL NEED
 TO REVIEW THE SPEC AND AGREE BEFORE THE REVIEW CAN BE
 PASSED. THE SPEC CAN BE SENT IN PDF FORM TO BOTH
 BUILDING & PLUMBING REVIEWERS. ONCE APPROVAL OF THE
 SPEC IS REACHED THE BUILDING PLANS EXAMINER WILL BE
 ABLE TO PASS THE BUILDING PORTION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE
 WORKING FROM CITY HALL
 MY WORK HOURS ARE MON. & TUES. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-05-18 Cont ID  
Sent By jwitmer Date 2021-05-18 Time 15:59 Rev Time 0.00
Received By jwitmer Date 2021-05-18 Time 11:31 Sent To  
Notes
2021-05-18 15:59:15WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21041405
 ADD: 5325 GREENWOOD AVE. SUITE 100
 CONT: BLACK DIAMOND GENERAL CONTRACTING
 TEL: 561-746-3452
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. MAY 18TH/2021
 ACTION: DENIED
  
 1) DISCREPANCY IN THE PERMIT APPLICATION STATING WORK
 IS TO BE COMPLETED IN SUITE 100 WHEREAS THE INDEX SHEET
 LIST WORK ON BOTH THE 1ST FLOOR AND THE 2ND FLOOR.
 DISCREPANCY IN WORK AREA. 107.2.1.2. IS THE DOLLAR
 VALUE LISTED ON THE PERMIT FOR ONLY THE 1ST FLOOR SINCE
 THE WORK AREA INDICATES SUITE # 100? 107.2.1.2
 ADDITIONAL INFORMATION REQUIRED.
  
 2) THE COVERSHEET / CODE ANALYSIS:
  
 2A) HEADING GOVERNING CODES LIST THE 2017 FLORIDA
 BUILDING CODE. PLEASE NOTE THE 7TH EDITION OF THE
 FLORIDA BUILDING CODE 2020 WAS ADOPTED STATEWIDE ON
 DEC. 31/ 2020. PLEASE UPDATE ALL CODE REFERENCES TO THE
 2020 FBC-BUILDING.
  
 2B) HEADING IV. CONSTRUCTION TYPE IS GRAYED OUT BUT
 INDICATING CONSTRUCTION TYPE II-A / SPRINKLERED. THIS
 SHOULD NOT BE GRAYED OUT. IT IS ONE OF THE REQUIREMENTS
 UNDER THE 2020 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS AND
 OR STRUCTURES.
 107.3.5.1 COMMERCIAL BUILDINGS
 107.3.5.1.1. BUILDING REVIEW
 MINIMUM CONSTRUCTION TYPE.
  
 2C) HEADING VI BUILDING PROTECTION-EXISTING (D). THE
 HEADING FLOOR CONSTRUCTION LIST A ZERO-HOUR FIRE RATING
 IN YOUR TABLE 601 WHEREAS IN EITHER THE 2017 OR THE
 2020 FBC-BUILDING FOR A TYPE II-A BUILDING THE FLOOR
 CONSTRUCTION RATING IS ONE-HOUR.
  
 2D) NOTE ON THE BOTTOM OF THE SECTION BUILDING
 PROTECTION STATES DUE TO THE ASC LOCATED ON THE THIRD
 FLOOR ALL COLUMNS ARE TO BE RATED ONE HOUR ON THE FIRST
 AND SECOND FLOOR ALONG WITH FLOOR ELEVATOR LOBBY. THIS
 WORK WOULD APPEAR TO BE IN OTHER TENANT SPACES, HOW
 WILL THAT WORK TAKE PLACE WITH TENANT IN PLACE?
 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED.
  
 2E) HEADING BUILDING EGRESS ( C ) EXIT ACCESS (2) LIST
 COMMON PATH OF TRAVEL LIST 100 FEET AND SECTION
 1006.2..1. THIS CODE SECTION TIES TO TABLE 1006.2.1 AS
 WELL. THIS TABLE ONLY WORKS FOR THE 1ST FLOOR. PLEASE
 REVIEW SECTION 1006.1 WHICH REFERS YOU TO SECTION
 1006.3 FOR STORIES AND TABLE 1006.3.2(2) SEE FIRST
 STORY ABOVE GRADE 49 OCCUPANTS AND 75 FEET.
  
 2F) HEADING VIII OCCUPANT LOAD. PLEASE NOTE IN THE 2017
 FBC-B THE OCCUPANT LOAD FACTOR FROM TABLE 1004.1.2 WAS
 FOR A BUSINESS OCCUPANCY WAS 100 BUT UNDER THE 2020
 FBC-BUILDING CODE FOR BUSINESS OCCUPANCY AND IN TABLE
 1004.5 THE OCCUPANT LOAD FACTOR IS 150. PLEASE ALSO
 REVIEW SECTION 1004.8 CONCENTRATED BUSINESS USE AREAS.
  
 3) SHEET LS101:
  
 3A) THE REAR EXIT, EXIT # 2 EXITS DIRECTLY TO THE
 EXTERIOR OF THE BUILDING. THE FRONT STAIR, STAIR # 1 IS
 A INTERIOR EXIT STAIRWAY THAT DOES NOT LEAD DIRECTLY TO
 THE EXTERIOR OF THE BUILDING. SECTION 1028 EXIT
 DISCHARGE DOES LIST EXCEPTIONS, EXCEPTIONS 1 & 2 SHALL
 NOT EXCEED 50 PER CENT OF THE NUMBER AND MINIMUM WIDTH
 OR REQUIRED CAPACITY OF THE REQUIRED EXITS.
  
 3B) PEDS GYM ROOM 1005 THERE IS A DISCREPANCY IN THE
 LIFE SAFETY SHEET AND A151 AT THE DOORWAY LIFE SAFETY
 SHEET MISSING THE HYDROC COLD AND HOT BY DOORWAY.
  
 4) 2ND FLOOR LIFE SAFETY, SHEET A-152 2ND FLOOR NOTES.
 ROOM 2027 IS THE X-RAY ROOM THERE IS A NOTE TO SEE
 A2.01 X-RAY ROOM. THIS SHEET STATES SEE THE PHYSICIST?S
 REPORT FOR SHIELDING REQUIREMENTS. THIS REPORT NOT
 INCLUDED IN THIS REVIEW. THE REPORT SHOULD HAVE THE
 DESIGNER SHOP DRAWING STAMP OF APPROVAL BEFORE
 SUBMITTING TO THE BUILDING DEPARTMENT. 2020 FBC-B
 SECTION 465.
  
 5A) SHEET A201 DETAILS A, C, D-2023 & 2024 ALL SHOW A
 INSWING DOOR INTO THE RESTROOMS AND CROSSING OVER THE
 CLEAR FLOOR SPACE FOR THE LAV. 2020 FBC-ACCESSIBILITY
 CODE. PLEASE REVIEW SECTION 603.2.3. DOORS SHALL NOT
 SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCES REQUIRED
 FOR ANY FIXTURE. DOORS SHALL BE PERMITTED TO SWING INTO
 THE REQUIRED TURNING SPACE. PLEASE SEE EXCEPTION 2.
 WHERE TOILET ROOMS ARE FOR INDIVIDUAL USE AND A CLEAR
 FLOORS SPACE COMPLYING WITH 305.3 IS PROVIDED WITHIN
 THE ROOM BEYOND THE ARC OF THE DOOR SWING. WHAT IS
 MISSING IS THE REQUIRED 30X48 INCH CLEAR FLOOR SPACE
 BEYOND THE ARC OF THE DOOR. USUALLY AT A 45% ANGLE TO
 THE DOOR ENTRANCE.
  
 5B) TOILET ACCESSORIES LEGEND INDICATES FOR ALL GRAB
 BARS 33 INCHES TO THE CENTER LINE OF THE GRAB BAR. 2020
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
  
 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-08-13 Cont ID  
Sent By jleahy Date 2021-08-13 Time 15:38 Rev Time 0.00
Received By jleahy Date 2021-08-13 Time 15:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-07-28 Cont ID  
Sent By fgiaquin Date 2021-07-28 Time 20:56 Rev Time 0.00
Received By fgiaquin Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-06-10 Cont ID  
Sent By fgiaquin Date 2021-06-10 Time 22:23 Rev Time 0.00
Received By fgiaquin Date 2021-06-10 Time 20:54 Sent To  
Notes
2021-06-10 22:15:14ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE LOAD CALCULATION OF SERVICE TO INCLUDE BOTH
 NEW AND EXISTING LOADS. NEC 220 FBC 107.2.1
  
 2. DESIGN PROFESSIONAL TO SPECIFY WHAT AREAS ARE
 "PATIENT CARE AREAS" AND WIRING METHOD. FBC 107.2.1 NEC
 517
  
 3. NO CONDUIT OR WIRE SIZE SHOWN FOR NEW SERVICE ITEMS.
 FBC 107.2.1
  
 4. ALL FIRE ALARM SHOWN MUST BE REMOVED FROM PLAN AND
 APPLIED FOR UNDER A SEPARATE PERMIT WITH SEPARATE
 DRAWINGS. FBC 105.1
  
 5. PROVIDE NOTE ON PLANS THAT ALL LOW VOLTAGE SYSTEMS
 SHOWN ON PLANS WILL REQUIRE SEPARATE LOW VOLTAGE
 PERMITS, A NOTE ON PLAN WILL SUFFICE. FBC 107.2.1
  
  
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-805-6744
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2021-08-11 Cont ID  
Sent By pleduc Date 2021-08-11 Time   Rev Time 0.00
Received By pleduc Date 2021-08-11 Time 11:54 Sent To  
Notes
2021-08-11 11:55:42FIRE PROVISO:
  
 ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS,
 INCLUDING DEMO, SHALL BE DONE UNDER SEPARATE PERMITS
 AND SHOP DRAWINGS.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-07-14 Cont ID  
Sent By pleduc Date 2021-07-14 Time   Rev Time 0.00
Received By pleduc Date 2021-07-14 Time 10:38 Sent To  
Notes
2021-07-14 10:38:56FIRE PROVISO:
  
 ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS,
 INCLUDING DEMO, SHALL BE DONE UNDER SEPARATE PERMITS
 AND SHOP DRAWINGS.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-05-19 Cont ID  
Sent By pleduc Date 2021-05-19 Time   Rev Time 0.00
Received By pleduc Date 2021-05-19 Time 13:39 Sent To  
Notes
2021-05-19 16:00:34FIRE PROVISO:
  
 ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS,
 INCLUDING DEMO, SHALL BE DONE UNDER SEPARATE PERMITS
 AND SHOP DRAWINGS.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-08-28 Cont ID  
Sent By medwards Date 2021-08-28 Time 08:35 Rev Time 0.00
Received By medwards Date 2021-08-27 Time 09:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-08-24 Cont ID  
Sent By jwitmer Date 2021-08-24 Time 10:17 Rev Time 0.00
Received By jwitmer Date 2021-08-10 Time 11:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-07-29 Cont ID  
Sent By medwards Date 2021-07-29 Time 09:53 Rev Time 0.00
Received By medwards Date 2021-07-13 Time 15:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2021-06-16 Time   Rev Time 0.00
Received By cdecoeur Date 2021-05-13 Time 08:52 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2021-08-28 Cont ID  
Sent By medwards Date 2021-08-28 Time 08:34 Rev Time 0.00
Received By medwards Date 2021-08-28 Time 08:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2021-08-20 Cont ID  
Sent By medwards Date 2021-08-20 Time 16:13 Rev Time 0.00
Received By medwards Date 2021-08-20 Time 16:13 Sent To  
Notes
2021-08-20 16:18:551) THE OUTDOOR AIR CALCULATIONS HAVE THE SPACE TYPE
 LISTED ON ALL ROOMS AS OFFICE SPACES THIS IS INCORRECT.
 PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS BASED ON
 USE OF SPACE FOR THE ENTIRE TENANT SPACE. FBC M
 403.3.1.1 AND TABLE 403.3.1.1
  
 2) PLEASE SHOW THE REQUIRED VENTILATION FOR THE SOILED
 STORAGE ROOM 1012
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2021-07-29 Cont ID  
Sent By medwards Date 2021-07-29 Time 09:48 Rev Time 0.00
Received By medwards Date 2021-07-29 Time 09:42 Sent To  
Notes
2021-07-29 09:52:46ARCHITECT'S RESPONSE LETTER MENTIONS CORRECTIONS WERE
 MADE ON SHEETS: M0.01, M0.02, M0.03, M0.04, I DO NOT
 SEE THESE SHEETS IN THIS SUBMITTAL. PLEASE SUBMIT IN
 THE NEXT CYCLE OF REVIEWS.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-06-14 Cont ID  
Sent By medwards Date 2021-06-14 Time 12:42 Rev Time 0.00
Received By medwards Date 2021-06-14 Time 12:42 Sent To  
Notes
2021-06-14 12:42:301ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21041405
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FBC EC C403.2
  
 2) PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS BASED ON
 FBC M 403.3.1.1 AND TABLE 403.3.1.1, NOT THE
 ARCHITECTURAL OCCUPANT COUNT.
  
 3) SHEET M001: PLEASE PROVIDE THE CONDENSATION PIPING
 MATERIAL AND SIZES. FBC M 307
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-08-20 Cont ID  
Sent By ccole Date 2021-08-20 Time 11:59 Rev Time 0.00
Received By ccole Date 2021-08-20 Time 07:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-07-27 Cont ID  
Sent By ccole Date 2021-07-27 Time 15:13 Rev Time 0.00
Received By ccole Date 2021-07-27 Time 10:39 Sent To  
Notes
2021-07-27 15:13:382ND REVIEW FBC-2020 PLUMBING
 PERMIT-21041405
 7/27/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES IN
 CAPS.
  
 1) FAILED. PROVIDE SANITARY DRAINAGE AND VENT, AND
 WATER DISTRIBUTION ISOMETRIC DRAWINGS- SECTIONS
 107.3.5.1.3 AND 107.2.1 WPB. SHOW LOICATIONS OF
 REQUIRED SHUTOFF VALVES AT THE BASE OF THE RISER PIPE
 AND AT THE TOP OF DOWN FEEDING PIPE- SECTION 606.1 FBC
 P.
  
 2) FAILED. REFER TO TABLE 403.1 AND PROVIDE PLUMBING
 FIXTURE CALCULATIONS. PROVIDE A SCHEDULE THAT INDICATES
 THE REQUIRED AND PROVIDED NUMBER OF PLUMBING FIXTURES
 BASED ON THE OCCUPANCY CLASSIFICATION OF THE SPACE AND
 OCCUPANT LOAD. SHOW THE CALCULATIONS FOR BOTH PUBLIC
 AND EMPLOYEE USE IN ACCORDANCE WITH SECTION 403.3 FBC P
 AND SHOW THAT THE MINIMUM FIXTURES HAVE BEEN PROVIDED
 FOR EACH. PLEASE LABEL TLT 1004 AS EITHER STAFF OR
 PATIENT ON THE ARCHITECTURAL AND PLUMBING PLANS.
 BECAUSE THE PLANS ARE INDICATING SEPARATE FACILITIES
 FOR PUBLIC AND STAFF USE, THEN AN EQUAL NUMBER OF WATER
 CLOSETS AND LAVATORIES FOR MALE AND FEMALE USE SHALL BE
 PROVIDED TO BOTH THE PUBLIC AND THE STAFF. PLEASE
 REVISE THE CALCULATION SCHEDULE ON G1.01 TO LIST THE
 REQUIRED AND PROVIDED NUMBER OF MALE AND FEMALE
 FIXTURES FOR BOTH THE PUBLIC AND STAFF, AND IDENTIFY
 THE LOCATIONS ON THE PLANS.
  
 8) FAILED. P101 & P201: PLASTER TRAPS ARE SPECIFIED.
 PLEASE ADD THE MAKE AND MODEL OF THE TRAPS TO THE
 FIXTURE SCHEDULE ON P001. A) PROVIDE AN ENLARGED
 PLUMBING PIPING INSTALLATION DETAIL- SECTION 1003.2 FBC
 P. B) PROVIDE A NARRATIVE TO CLARIFY WHAT PROCESSES ARE
 BEING CONDUCTED IN THE FACILITY THAT WILL REQUIRE
 INSTALLATION OF THE TRAPS- SECTION 107.2.1 WPB. DETAIL
 AND NARRATIVE NOT PROVIDED.
  
 9) FAILED. PLEASE INDICATE THE TYPE OF WALL FINISH
 MATERIAL TO BE INSTALLED AROUND THE NEW SECOND FLOOR
 MOP SINK- SEE SECTION 310.3 FBC P AND SECTION 1210.2.2
 FBC B. THE RESPONSE INDICATES "RIGID SHEET WALL
 SURROUND". PLEASE IDENTIFY WHAT THE SHEET WALL
 MATERIALS ARE.
  
 13) FAILED D, F, G. A201 MISSING ACCESSIBILITY DETAILS
 FOR THE TOILET ROOMS PER FBC ACC: PLEASE NOTE THAT ALL
 FIGUIRES IN THE TYPICAL DETAILS ON G401 SHALL BE IN
 COMPLIANCE WITH THE FLORIDA BUILDING CODE- ACCESIBILITY
 7TH EDITION 2020.
  
 D) FAILED. LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF
 GRAB BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4,
 FIGURES 604. SHEET G401: VERTICAL GRAB BAR IS SHOWN IN
 THE TYP. ACCESSIBLE TOILET ELEVATIONS. GRAB BARS SHALL
 BE INSTALLED IN HORIZONTAL POSITIONS.
  
 F) FAILED. CENTERLINES OF THE TOILET PAPER DISPENSER
 MEASURED FROM THE FRONTS OF THE WATER CLOSETS- SECTION
 AND FIGURE 604.7. THE CENTERLINE SHOWN IN THE TYP.
 ELEVATION IS NOT IN THE CENTER OF THE DISPENSER- PLEASE
 CORRECT.
  
 G) FAILED. KNEE AND TOE CLEARANCES FOR THE LAVATORIES-
 SECTION 606.2. NOT PROVIDED.
  
 14) FAILED. A101, A102, A801: INDICATE THE CLEAR FLOOR
 SPACE DIAGRAMS AND DIMENSIONS FOR THE ACCESSIBLE SINKS
 ON THE PLAN. SHOW EITHER A FORWARD OR PARALLEL APPROACH
 WHERE REQUIRED- SEE SECTIONS 212.3 & 606.2 FBC ACC. NOT
 PROVIDED. THE ARCHITECT'S RESPONSE REFERENCES P2
 LAVATORY SINKS. LOCATIONS AND DETAILS FOR THE OTHER
 ACCESSIBLE SINKS IN THE LOUNGES, EAXAM AND TREATMENT
 ROOMS ETC.NOT COMPLETELY PROVIDED.
  
 16) FAILED. A102 & A801: PROVIDE THE CLEAR FLOOR SPACE
 DIAGRAM AND DIMENSION FOR THE WATER COOLER IN ROOM
 2028. A) ADD THE COOLER TO THE FIXTURE SCHEDULE ON
 P001. B) SUBMIT MANUFACTURER'S SPECIFICATIONS AND
 PROVIDE AN ELEVATION DRAWING TO SHOW COMPLIANCE WITH
 SECTIONS 308 & 309 FBC ACC- REACH RANGES AND CONTROLS.
 THE REQUESTED PRODUCT SPECS WERE NOT PROVIDED.
  
 17) FAILED. P001: PROVIDE HOT WATER PIPE INSULATION
 SPECIFICATIONS IN ACCORDANCE WITH TABLE C403.2.10 FBC
 EC. NOT PROVIDED. THE ARCHITECT REFERENCES THE PROJECT
 SPECIFICATION BOOK WHICH WAS NOT SUBMITTED AND WHICH
 WILL NOT BE REVIEWED.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-06-16 Cont ID  
Sent By ccole Date 2021-06-16 Time 18:36 Rev Time 0.00
Received By ccole Date 2021-06-16 Time 13:19 Sent To  
Notes
2021-06-16 18:36:191ST REVIEW FBC-2020 PLUMBING
 PERMIT-21041405
 6/16/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE SANITARY DRAINAGE AND VENT, AND WATER
 DISTRIBUTION ISOMETRIC DRAWINGS- SECTIONS 107.3.5.1.3
 AND 107.2.1 WPB.
  
 2) REFER TO TABLE 403.1 AND PROVIDE PLUMBING FIXTURE
 CALCULATIONS. PROVIDE A SCHEDULE THAT INDICATES THE
 REQUIRED AND PROVIDED NUMBER OF PLUMBING FIXTURES BASED
 ON THE OCCUPANCY CLASSIFICATION OF THE SPACE AND
 OCCUPANT LOAD. SHOW THE CALCULATIONS FOR BOTH PUBLIC
 AND EMPLOYEE USE IN ACCORDANCE WITH SECTION 403.3 FBC P
 AND SHOW THAT THE MINIMUM FIXTURES HAVE BEEN PROVIDED
 FOR EACH. PLEASE LABEL TLT 1004 AS EITHER STAFF OR
 PATIENT ON THE ARCHITECTURAL AND PLUMBING PLANS.
  
 3) SHEET P201: PLEASE PROVIDE A NOTE BY EACH CIRCULAR
 SYMBOL SHOWN ON THE PLAN I.E. KEYNOTE 4 IS SPECIFYING A
 FLOOR DRAIN AND 5 IS SPECIFYING A PLASTER TRAP.
  
 4) P001: PROVIDE THE EFFICIENCY RATINGS OF THE WATER
 HEATERS IN THE SCHEDULE- TABLE C404.2 FBC EC.
  
 5) P001: PROVIDE PANS AND PAN DRAINS FOR THE WATER
 HEATERS- SECTION 504.7 FBC P.
  
 6) P201: NEW FIXTURE DRAIN INSTALLATIONS MAY REQUIRE
 THE FLOOR TO BE X-RAYED TO IN ORDER TO LOCATE
 REINFORCING STEEL OR POST STRESSED FLOOR TENDONS.
 PLEASE PLACE A NOTE ON THE PLANS TO VERIFY COMPLIANCE
 WILL BE MET- SECTION 107.2.1 WPB.
  
 7) P201: NEW FIXTURE DRAIN PIPE PENETRATIONS OF THE
 EXISTING SLAB WILL REQUIRE FIRESTOPPING TO SEAL THE
 ANNULAR SPACE AROUND THE PIPING. PROVIDE A UL TESTED
 AND APPROVED FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN-
 SECTION 315.1 FBC P AND SECTION 714.4.1.2 FBC B.
  
 8) P101 & P201: PLASTER TRAPS ARE SPECIFIED. PLEASE ADD
 THE MAKE AND MODEL OF THE TRAPS TO THE FIXTURE SCHEDULE
 ON P001. A) PROVIDE AN ENLARGED PLUMBING PIPING
 INSTALLATION DETAIL- SECTION 1003.2 FBC P. B) PROVIDE A
 NARRATIVE TO CLARIFY WHAT PROCESSES ARE BEING CONDUCTED
 IN THE FACILITY THAT WILL REQUIRE INSTALLATION OF THE
 TRAPS- SECTION 107.2.1 WPB.
  
 9) PLEASE INDICATE THE TYPE OF WALL FINISH MATERIAL TO
 BE INSTALLED AROUND THE NEW SECOND FLOOR MOP SINK- SEE
 SECTION 310.3 FBC P AND SECTION 1210.2.2 FBC B.
  
 10) SHEET A201: DOORS SHALL NOT SWING INTO THE CLEAR
 FLOOR SPACE OF THE LAVATORIES- SECTION 603.2.3 FBC ACC.
  
 11) A201: PROVIDE THE DIMENSIONS OF THE CLEAR FLOOR
 SPACES FOR THE WATER CLOSETS AND LAVATORIES- SECTIONS
 604.3 & 606.2 FBC ACC.
  
 12) A201: PROVIDE THE TURNING SPACE DIAMETERS- SECTION
 304.3. FBC ACC.
  
 13) A201 MISSING ACCESSIBILITY DETAILS FOR THE TOILET
 ROOMS PER FBC ACC:
  
 A) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED
 FLOORS- SECTION 604.4.
  
 B) HEIGHTS OF THE LAVATORY SINK RIM OR COUNTER SURFACE
 FROM THE FINISHED FLOOR- SECTION 606.3.
  
 C) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO
 THE REFLECTIVE SURFACES- SECTION 603.3.
  
 D) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB
 BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4,
 FIGURES 604.
  
 E) LOCATION OF THE WATER CLOSET FLUSH CONTROLS -
 SECTION 604.6.
  
 F) CENTERLINES OF THE TOILET PAPER DISPENSER MEASURED
 FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND
 FIGURE 604.7.
  
 G) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION
 606.2.
  
 14) A101, A102, A801: INDICATE THE CLEAR FLOOR SPACE
 DIAGRAMS AND DIMENSIONS FOR THE ACCESSIBLE SINKS ON THE
 PLAN. SHOW EITHER A FORWARD OR PARALLEL APPROACH WHERE
 REQUIRED- SEE SECTIONS 212.3 & 606.2 FBC ACC.
  
 15) PLEASE REFER TO COMMENT # 2 CONCERNING DRINKING
 FOUNTAINS. IN ACCORDANCE WITH TABLE 403.1 DRINKING
 FOUNTAINS ARE REQUIRED FIXTURES. PLEASE SHOW THE
 LOCATIONS OF THE REQUIRED DRINKING FOUNTAINS AND
 PROVIDE DRINKING FOUNTAIN INSTALLATION DETAILS AND
 ELEVATION VIEWS SHOWING KNEE AND TOE CLEARANCES, SPOUT
 HEIGHTS, AND SPOUT LOCATIONS- SECTIONS 306, 307, AND
 602 FBC ACC. SHOW THE REQUIRED 30 X 48 IN. CLEAR FLOOR
 SPACE FOR A FORWARD WHEELCHAIR APPROACH TO THE
 FOUNTAIN- SECTION 602.2 FBC ACC, AND SHOW HOW THE
 LOCATIONS OF THE FOUNTAINS WILL BE IN COMPLIANCE WITH
 SECTION 307.2 PROTRUSION LIMITS.
  
 16) A102 & A801: PROVIDE THE CLEAR FLOOR SPACE DIAGRAM
 AND DIMENSION FOR THE WATER COOLER IN ROOM 2028. A) ADD
 THE COOLER TO THE FIXTURE SCHEDULE ON P001. B) SUBMIT
 MANUFACTURER?S SPECIFICATIONS AND PROVIDE AN ELEVATION
 DRAWING TO SHOW COMPLIANCE WITH SECTIONS 308 & 309 FBC
 ACC- REACH RANGES AND CONTROLS.
  
 17) P001: PROVIDE HOT WATER PIPE INSULATION
 SPECIFICATIONS IN ACCORDANCE WITH TABLE C403.2.10 FBC
 EC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-08-28 Cont ID  
Sent By medwards Date 2021-08-28 Time 08:35 Rev Time 0.00
Received By medwards Date 2021-08-28 Time 08:35 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-08-24 Cont ID  
Sent By jwitmer Date 2021-08-24 Time 10:17 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-07-28 Cont ID  
Sent By fgiaquin Date 2021-07-28 Time 20:56 Rev Time 0.00
Received By fgiaquin Date 2021-07-28 Time 20:56 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-06-14 Cont ID  
Sent By medwards Date 2021-06-14 Time 13:00 Rev Time 0.00
Received By medwards Date 2021-06-14 Time 13:00 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-05-25 Cont ID  
Sent By llouie Date 2021-05-25 Time   Rev Time  
Received By llouie Date 2021-05-25 Time   Sent To  
Notes
***NONE***