Plan Review Details - Permit 21041393
Plan Review Stops For Permit 21041393
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-05-29 Cont ID  
Sent By cthroop Date 2021-05-29 Time 10:10 Rev Time 0.00
Received By cthroop Date 2021-05-29 Time 09:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-07-08 Cont ID  
Sent By jleahy Date 2021-07-08 Time 14:40 Rev Time 0.00
Received By jleahy Date 2021-07-07 Time 16:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-06-18 Cont ID  
Sent By jleahy Date 2021-06-18 Time 13:20 Rev Time 0.00
Received By jleahy Date 2021-06-18 Time 13:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-05-21 Cont ID  
Sent By equinone Date 2021-05-21 Time 09:58 Rev Time 0.00
Received By equinone Date 2021-05-21 Time 09:54 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2021-07-13 Cont ID  
Sent By ccole Date 2021-07-13 Time 17:14 Rev Time 0.00
Received By ccole Date 2021-07-13 Time 17:06 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2021-06-24 Cont ID  
Sent By ccole Date 2021-06-24 Time 09:27 Rev Time 0.00
Received By ccole Date 2021-06-24 Time 08:10 Sent To  
Notes
2021-06-24 09:27:362ND REVIEW FBC-2020 RES.
 PERMIT- 21041393
 6/24/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET E1: THE CONTRACTOR STEVEN KLIX WHO PREPARED
 THE DRAWING SHALL PROVIDE A SUB-PERMIT APPLICATION FOR
 DESIGN AND INSTALLATION OF THE GAS SYSTEM AS REQUIRED
 BY SECTIONS 105.1 & 107.2.1 WPB. PLEASE NOTE THE
 LICENSE NUMBER 45039 LISTED IN THE DIGITAL SIGNATURE
 DOES NOT MATCH THE LICENSE NUMBER REGISTERED WITH THE
 FDACS FOR STEVEN C. KLIX WHICH IS LQ29805. IF YOU HAVE
 QUESTIONS REGARDING LICENSURE AND CONTRACTOR
 REGISTRATION WITH THE CITY OF WEST PALM BEACH PLEASE
 CONTACT ME- SEE CONTACT INFO BELOW.
  
 2) E1: THE RISER INDICATES TWO MAIN SUPPLY PIPE OUTLETS
 AT THE METER WHICH DOES NOT APPEAR TO BE CORRECT.
 TYPICALLY METERS HAVE ONE OUTLET FOR A MAIN SUPPLY
 PIPE. PLEASE SHOW THE TYPE AND SIZE OF MAIN SUPPLY PIPE
 AND LOCATION OF THE TEE FOR THE BRANCH LINE TO THE
 GENERATOR- SECTION G2413.1 FBC FG.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-05-26 Cont ID  
Sent By ccole Date 2021-05-26 Time 17:31 Rev Time 0.00
Received By ccole Date 2021-05-26 Time 16:16 Sent To  
Notes
2021-05-26 17:31:281ST REVIEW FBC-2020 RES.
 PERMIT- 21041393
 5/26/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET E.01: GAS RISER DRAWINGS SHALL BE PREPARED BY
 EITHER A FL. LICENSED DESIGN PROFESSIONAL OR A FL.
 LICENSED PLUMBING OR GAS CONTRACTOR. THE ELECTRICAL
 CONTRACTOR IS NOT PERMITTED TO DESIGN THE SYSTEM AND
 PREPARE THE DRAWING- SECTION 107.2.1 WPB, AND FLORIDA
 STATUTES 471.003(2)(H) & 471.025.
  
 2) 1) PROVIDE A COMPLETE GAS RISER DRAWING THAT
 INCLUDES ALL NEW AND EXISTING GAS PIPING AND APPLIANCES
 AT THE RESIDENCE- SECTION G2412.3 & G2412.4 FBC RES.
 CITY OF WPB BUILDING DEPT. RECORDS INDICATES A GAS POOL
 HEATER WAS INSTALLED UNDER PERMIT- 02011630. REFER TO
 FBC RES. CHAPTER 24 FUEL GAS- THE RISER SHALL INDICATE:
  
 A) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 B) TYPES AND SIZES OF PIPING.
 C) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 D) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 E) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE
 UNIONS.
 F) OUTLET PRESSURES AT REGULATORS.
 G) LOCATIONS AND TYPES OF PIPE SLEEVES.
 H) PIPE SIZING TABLES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2021-07-13 Time   Rev Time 0.00
Received By aoliver Date 2021-06-29 Time 08:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2021-06-24 Time   Rev Time 0.00
Received By lmarchan Date 2021-06-14 Time 15:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-29 Cont ID  
Sent By cthroop Date 2021-05-29 Time 10:10 Rev Time 0.00
Received By cthroop Date 2021-05-10 Time 16:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status N Date 2021-07-13 Cont ID  
Sent By ccole Date 2021-07-13 Time 17:15 Rev Time 0.00
Received By ccole Date 2021-07-13 Time 17:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2021-06-24 Cont ID  
Sent By ccole Date 2021-06-24 Time 09:33 Rev Time 0.00
Received By ccole Date 2021-06-24 Time 08:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2021-05-26 Cont ID  
Sent By ccole Date 2021-05-26 Time 17:36 Rev Time 0.00
Received By ccole Date 2021-05-26 Time 16:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-07-13 Cont ID  
Sent By ccole Date 2021-07-13 Time 17:14 Rev Time 0.00
Received By ccole Date 2021-07-13 Time 17:06 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-06-24 Cont ID  
Sent By ccole Date 2021-06-24 Time 09:33 Rev Time 0.00
Received By ccole Date 2021-06-24 Time 08:10 Sent To  
Notes
2021-06-24 09:34:12GENERATOR PAD.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-05-29 Cont ID  
Sent By cthroop Date 2021-05-29 Time 10:10 Rev Time 0.00
Received By cthroop Date 2021-05-29 Time 09:38 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-05-25 Cont ID  
Sent By rthermid Date 2021-05-25 Time   Rev Time  
Received By rthermid Date 2021-05-25 Time   Sent To I
Notes
2021-05-25 09:15:09ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 5/25/2021
 ________________________________________
  
 REVIEW STATUS: PASSED WITH PROVISOS
 ________________________________________
  
 THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING
 PROVISOS:
  
 1. GENERATOR EXHAUST MUST BE A MINIMUM OF 10 FEET FROM
 ALL DOORS AND WINDOWS
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 RAFAELA THERMIDOR, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved