Plan Review Details - Permit 21041347
Plan Review Stops For Permit 21041347
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-05-20 Cont ID  
Sent By jleahy Date 2021-05-20 Time 16:44 Rev Time 0.00
Received By jleahy Date 2021-05-20 Time 16:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-05-11 Cont ID  
Sent By jleahy Date 2021-05-11 Time 13:23 Rev Time 0.00
Received By jleahy Date 2021-05-11 Time 11:47 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2021-05-21 Cont ID  
Sent By pleduc Date 2021-05-21 Time   Rev Time 0.00
Received By pleduc Date 2021-05-21 Time 10:12 Sent To  
Notes
2021-05-21 10:15:12THE PREVIOUS FIRE COMMENTS DO NOT APPEAR TO BE
 SPECIFICALLY ADDRESSED.
  
 THIS PERMIT WILL BE PASSED WITH PROVISO COMMENTS THAT
 WILL BE REVIEWED DURING FIRE INSPECTIONS.
  
 THE PREVIOS COMMENTS ARE SUBMITTAL BELOW AS PROVISO:
  
  
 1) THERE IS AN INDICATION OF A FIRE ALARM RELAY.
  
 WHAT IS THE SEQUENCE OF OPERATION FOR THE FA RELAY?
  
  
 2) THERE IS NO INDICATIONA A KNOX KEY SWITCH.
  
 HOW DOES THE FD GAIN ACCESS IN EMERGENCY SIUATIONS NOT
 RELATED TO THE ACTIVATION OF A FIRE ALARM(PER # 1 ABOVE
 IF THE GATE OPENS ON FIRE ALARM)?
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-05-13 Cont ID  
Sent By pleduc Date 2021-05-13 Time   Rev Time 0.00
Received By pleduc Date 2021-05-13 Time 16:15 Sent To  
Notes
2021-05-13 16:17:49THE PREVIOUS FIRE COMMENTS DO NOT APPEAR TO BE
 SPECIFICALLY ADDRESSED.
  
 THIS PERMIT WILL BE PASSED WITH PROVISO COMMENTS THAT
 WILL BE REVIEWED DURING FIRE INSPECTIONS.
  
 THE PREVIOS COMMENTS ARE SUBMITTAL BELOW AS PROVISO:
  
  
 1) THERE IS AN INDICATION OF A FIRE ALARM RELAY.
  
 WHAT IS THE SEQUENCE OF OPERATION FOR THE FA RELAY?
  
  
 2) THERE IS NO INDICATIONA A KNOX KEY SWITCH.
  
 HOW DOES THE FD GAIN ACCESS IN EMERGENCY SIUATIONS NOT
 RELATED TO THE ACTIVATION OF A FIRE ALARM(PER # 1 ABOVE
 IF THE GATE OPENS ON FIRE ALARM)?
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-05-03 Cont ID  
Sent By pleduc Date 2021-05-03 Time   Rev Time 0.00
Received By pleduc Date 2021-05-03 Time 13:29 Sent To  
Notes
2021-05-03 13:33:00THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE IS AN INDICATION OF A FIRE ALARM RELAY.
  
 WHAT IS THE SEQUENCE OF OPERATION FOR THE FA RELAY?
  
  
 2) THERE IS NO INDICATIONA A KNOX KEY SWITCH.
  
 HOW DOES THE FD GAIN ACCESS IN EMERGENCY SIUATIONS NOT
 RELATED TO THE ACTIVATION OF A FIRE ALARM(PER # 1 ABOVE
 IF THE GATE OPENS ON FIRE ALARM)?
  
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-05-25 Cont ID  
Sent By lcrespo Date 2021-05-25 Time 14:50 Rev Time 0.00
Received By lcrespo Date 2021-05-19 Time 07:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-05-14 Cont ID  
Sent By jgomez Date 2021-05-14 Time 10:00 Rev Time 0.00
Received By jgomez Date 2021-05-12 Time 09:37 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-11 Cont ID  
Sent By jleahy Date 2021-05-11 Time 13:23 Rev Time 0.00
Received By jleahy Date 2021-04-26 Time 09:15 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-05-25 Cont ID  
Sent By lcrespo Date 2021-05-25 Time 14:49 Rev Time 0.00
Received By lcrespo Date 2021-05-20 Time 10:04 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-05-11 Cont ID  
Sent By jleahy Date 2021-05-11 Time 13:23 Rev Time 0.00
Received By jleahy Date 2021-05-11 Time 11:47 Sent To  
Notes
2021-05-11 13:25:18ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) PLAN IS NOT DIGITALLY SIGNED BY THE DESIGNER OF
 RECORD
  
 PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN
 PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. FS
 471.003(2)(H); 471.025; FBC 107.2.1
  
  