Plan Review Details - Permit 21041308
| Plan Review Stops For Permit 21041308 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2022-01-10 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-01-10 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-01-10 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2022-01-10 17:06:17 | AREA OF WORK WILL BE FOR SUITES 3, 4, 5 AND 6 |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2021-12-15 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-12-15 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-15 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2021-12-15 16:10:44 | WHICH SUITES WILL THIS DECK BE ATTACHED TO? SUITES | | | 1,2,3,4,5,6,7,8 AND 9. PLEASE RESPOND TO [email protected] | | | OR CALL 561-805-6659 |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-11-01 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-11-01 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2021-11-01 08:44:04 | PLEASE PROVIDE A FLOOR PLAN SHOWING EVERY SUITE ON THAT | | | FLOOR AS IT APPEARS THAT DEMISING WALLS HAVE BEEN | | | REMOVED AND SUITES MAY NEED TO BE ELIMINATED OR | | | CONSOLIDATED. PLEASE EMAIL TO [email protected] FOR | | | FURTHER QUESTIONS YOU CAN ALSO CALL 561-805-6659 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2022-01-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-01-18 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-01-18 17:15:24 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21041308 | | | ADD: 3700 S. DIXIE HWY. BEHIND UNIT 3 | | | CONT: FOWLER BUILDING COMPANY | | | TEL: 772-486-5350 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 4TH REVIEW | | | DATE: 01/18/ 2022 | | | ACTION: DENIED | | | | | | NOTICE: 4X FEE / NOTICE!!!!! FLORIDA STATUTE | | | 553.80(2)(B) WITH RESPECT TO EVALUATION OF DESIGN | | | PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT FINDS | | | IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | | REVIEW. | | | | | | 1-2) COMPLIED. | | | | | | 3) SEMI-COMPLIED. 2020 EXISTING BUILDING CODE LEVEL II | | | 801.3 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, | | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING. | | | CREATION OR EXTENSION OF NONCONFORMITY. ALL NEW WORK, | | | RE-CONFIGURATION SHALL NOT CREATE OR EXTEND ANY | | | NONCONFORMITY IN THE EXISTING BUILDING TO WHICH THE | | | RE-CONFIGURATION OF SPACE IS BEING MADE WITH REGARD TO | | | ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE SAFETY, MEANS | | | OF EGRESS. | | | | | | 4) COMPLIED. | | | | | | 5) 4TH ROUND OF COMMENTS. RUSH DECK FLOOR PLAN. THE | | | FLOOR/ DECK PLAN. | | | | | | 5A) COMPLIED. ARCHITECT LETTER STATES NEW WOOD DECK | | | SAME LEVEL AS THE INTERIOR FINISH FLOOR. | | | | | | 5B) 4TH REQUEST. SEMI- COMPLIED. THE DECK FRAMING PLAN | | | DOES NOT SHOW COMPLIANCE WITH %A BUT ARCHITECTS LETTER | | | STATES THE NEW DECK IS THE SAME LEVEL AS THE INTERIOR | | | FINISH FLOOR. THE S1 SHEET DOES ALSO SHOW WHAT APPEARS | | | TO BE 2 EGRESS RAMPS DOWN TO GRADE BUT THERE IS ALSO A | | | DETAIL OF A EXISTING BUILDING WALL, LANDING THEN RAMP | | | DOWN TO GRADE. THAT DETAIL IS DRAWN AS IF YOU WERE | | | GOING OUT OF THE BUILDING TO A LANDING THEN DOWN TO | | | EXISTING PAVEMENT WHICH IS NOT THE CASE. | | | THE 2NS ISSUE THAT WAS NOT ADDRESSED RAMPS WITH A | | | HEIGHT GREATER THAN 6 INCHES REQUIRE HANDRAILS | | | INCOMPLIANCE WITH 1012.8 OF THE 2020 FBC-BUILDING CODE. | | | 3RD REVIEW COMMENT. IN CASE OF FIRE, ONE IS NOT TO GO | | | BACK INTO THE BUILDING, ONCE OUT OF THE BUILDING | | | SECTION 1028.1 OF THE 2020 FBC-B, THE EXIT DISCHARGE | | | SHALL NOT REENTER THE BUILDING. PLEASE SHOW THE 2 | | | REQUIRED ACCESSIBLE EXITS FROM THE DECK, THE PLANS DO | | | NOT SHOW RAMPS NOR HANDRAILS. 2020 FBC-ACCESSIBILITY | | | CODE SECTION 207.1 MEANS OF EGRESS SHALL COMPLY WITH | | | SECTION 1003.2.13 OF THE INTERNATIONAL BUILDING CODE | | | (2000 EDITION AND 2001 SUPPLEMENT) OR SECTION 1007 OF | | | THE INTERNATIONAL BUILDING CODE (2003 EDITION). 2003 | | | IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS IS | | | REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY | | | ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE | | | SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS. | | | | | | 5C) 4TH REQUEST. 3RD REQUEST. THE DECK FLOOR PLAN S-1 | | | SHOWS A DECK FRAMING PLAN AND RAMPS BUT NOT COMPLIANCE | | | WITH THE 2020 FBC-ACCESSIBILITY CODE SECTIONS 405.1 | | | THROUGH 405.10. | | | | | | 5D) PROVISO, TO BE VERIFIED IN THE FIELD. NO CUT | | | SECTION DETAIL SHOWING THE DECKING TO BE 5/4 PT | | | DECKING. WHAT IS MISSING IS THE SPACING BETWEEN BOARDS. | | | NOTE THAT THE PT DECKING WILL SHRINK MAKING THE SPACE | | | BETWEEN THE DECK BOARDS TO EXPAND WITH AGE. PLEASE | | | PROVIDE WHAT THE ACTUAL SPACING IS BETWEEN THE DECK | | | BOARDS, AND DO THEY COMPLY WITH THE 2020 | | | FBC-ACCESSIBILITY CODE SECTION 302.3. | | | | | | 6A) COMPLIED A-3 OCCUPANCY. | | | | | | 6B) COMPLIED. | | | | | | 7) 4TH REQUEST. PLEASE ALSO REVIEW IN THE 2020 FBC-B | | | TABLE 1607.1(4) LIVE LOADS FOR ASSEMBLY USAGE @ 150 PSF | | | FOR PLATFORMS. PLEASE ALSO NOTE THESE PLANS WILL NEED | | | TO BE COMPLETED BY AN ENGINEER FOR THE LOADING AND | | | SPACING OF ALL FRAMING MEMBERS. RESPONSE INDICATES SEE | | | S-1 FOR LOAD CALCULATIONS. WHERE? | | | | | | 8) NEW COMMENT. MEETING WITH MR. RUSH MR. DYLAN AND | | | MYSELF ON WED. DEC. 22ND AT CITY HALL BUILDING | | | CONFERENCE ROOM 2:00PM TO DISCUSS THIS PERMIT | | | (UNPERMITTED DECK) AND UNPERMITTED WORK ON THE INTERIOR | | | OF UNIT 3. MR. DYLAN PULLED UP OLD PERMITS TO BE VIEWED | | | ON THE BIG SCREEN TO SHOW THE LAST PERMITTED WORK | | | VERSES WHAT IS THERE NOW. ISSUES THAT ARE OF CONCERN | | | NEW UNDERGROUND PLUMBING, VENTING AND NEITHER OF THE | | | RESTROOMS HAVE BEEN UPDATED FOR ACCESSIBILITY | | | REQUIREMENTS. | | | | | | 9) NEW COMMENT. WITH THE 2 UNITS THAT WERE THERE AND | | | INCREASED OCCUPANT LOAD OF THE A3/ A2 ASSEMBLY USAGE ON | | | THE INTERIOR AND NEW OCCUPANT LOAD ON THE RAISED DECK, | | | EVEN IF ON GRADE AND THE SAME EXTERIOR AREA IS GOING TO | | | USE THIS EXTERIOR AREA THE ADDITIONAL OCCUPANT LOAD | | | WILL NEED TO BE SHOWN THAT THE EXISTING RESTROOM | | | FACILITIES WILL SHOW COMPLIANCE WITH 2020 FBC-BUILDING | | | CODE TABLE 2902.1. | | | | | | 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | | RETIRED. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-12-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-12-21 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-12-21 14:45:37 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21041308 | | | ADD: 3700 S. DIXIE HWY. | | | CONT: FOWLER BUILDING COMPANY | | | TEL: 772-486-5350 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: 12/212021 | | | ACTION: DENIED | | | | | | NOTICE: 4X FEE / NOTICE!!!!! FLORIDA STATUTE | | | 553.80(2)(B) WITH RESPECT TO EVALUATION OF DESIGN | | | PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT FINDS | | | IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | | REVIEW. | | | | | | | | | | | | 1-2) COMPLIED. | | | | | | 3) SEMI-COMPLIED. 2020 EXISTING BUILDING CODE LEVEL II | | | 801.3 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, | | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING. | | | CREATION OR EXTENSION OF NONCONFORMITY. ALL NEW WORK, | | | RE-CONFIGURATION SHALL NOT CREATE OR EXTEND ANY | | | NONCONFORMITY IN THE EXISTING BUILDING TO WHICH THE | | | RE-CONFIGURATION OF SPACE IS BEING MADE WITH REGARD TO | | | ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE SAFETY, MEANS | | | OF EGRESS. | | | | | | 4) 3RD REQUEST. PLEASE SUBMIT A SITE PLAN SHOWING THE | | | LOCATION OF THE BUILDING, IDENTIFY THE TENANT SPACE # 3 | | | SINCE THIS PERMIT IS BEING PULLED UNDER THAT TENANT | | | ADDRESS. PLEASE ALSO INCLUDE A LETTER FROM THE OWNERS | | | (MARA MANAGEMENT LLC) ON THE OWNER?S LETTERHEAD THEIR | | | APPROVAL OF THE DECK (PROVIDE SQUARE FEET OF DECK) AND | | | THEIR NOTARIZED SIGNATURE SINCE THE DECK LOCATION IS | | | PAST THE TENANT LEASE WALL AREA. 107.2.1.2. ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 5) 3RD ROUND OF COMMENTS. RUSH DECK FLOOR PLAN. THE | | | FLOOR/ DECK PLAN. | | | | | | 5A) 3RD REQUEST. RUSH DECK FLOOR PLAN. THE FLOOR/ DECK | | | PLAN INDICATES THE OCCUPANCY TYPE AS A-3 ART GALLERY | | | WITH SEATING. THE PLAN INDICATES THE DECK IS RAISED 6 | | | INCHES ABOVE GRADE. THE FLOOR PLAN DOES NOT INDICATE IF | | | THE NEW DECK IS THE SAME LEVEL AS THE FINISH FLOOR FROM | | | THE 4 DOORS THAT LEAD FROM THE INTERIOR. IT IS ASSUMED | | | TO GAIN ENTRY ONE HAS TO GO THROUGH THE TENANT SPACE TO | | | GET TO THE WOOD DECK. PLEASE SHOW COMPLIANCE WITH 2020 | | | FBC-ACCESS. CODE CHANGES IN LEVEL 303.2 AND 303.3. | | | WHERE CHANGES IN LEVEL ARE PERMITTED IN THE FLOOR OR | | | GROUND SURFACES, THEY SHALL COMPLY WITH SECTION 303. | | | SEE 303.1 & 303.2. | | | | | | 5B) 3RD REQUEST. IN CASE OF FIRE, ONE IS NOT TO GO BACK | | | INTO THE BUILDING, ONCE OUT OF THE BUILDING SECTION | | | 1028.1 OF THE 2020 FBC-B, THE EXIT DISCHARGE SHALL NOT | | | REENTER THE BUILDING. PLEASE SHOW THE 2 REQUIRED | | | ACCESSIBLE EXITS FROM THE DECK, THE PLANS DO NOT SHOW | | | RAMPS NOR HANDRAILS. 2020 FBC-ACCESSIBILITY CODE | | | SECTION 207.1 MEANS OF EGRESS SHALL COMPLY WITH SECTION | | | 1003.2.13 OF THE INTERNATIONAL BUILDING CODE (2000 | | | EDITION AND 2001 SUPPLEMENT) OR SECTION 1007 OF THE | | | INTERNATIONAL BUILDING CODE (2003 EDITION). 2003 IBC-B | | | 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS IS REQUIRED | | | BY SECTIONS 1014.1 OR 1018.1 FROM ANY ACCESSIBLE SPACE, | | | EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY | | | NOT LESS THAN TWO MEANS OF EGRESS. | | | | | | 5C) 3RD REQUEST. THE DECK FLOOR PLAN DATED 10/15/2021 | | | SHOWS A DECK FRAMING PLAN BUT NO RAMPS FOR EGRESS. SHOW | | | COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY CODE | | | SECTIONS 405.1 THROUGH 405.10. | | | | | | 5D) 3RD REQUEST. THE DECK FLOOR PLAN DATED 10/15/2021 | | | SHOWS A DECK FRAMING DETAIL AND CUT SECTION DETAIL | | | SHOWING THE DECKING TO BE 5/4 PT DECKING. WHAT IS | | | MISSING IS THE SPACING BETWEEN BOARDS. NOTE THAT THE PT | | | DECKING WILL SHRINK MAKING THE SPACE BETWEEN THE DECK | | | BOARDS TO EXPAND WITH AGE. PLEASE PROVIDE WHAT THE | | | ACTUAL SPACING IS BETWEEN THE DECK BOARDS, AND DO THEY | | | COMPLY WITH THE 2020 FBC-ACCESSIBILITY CODE SECTION | | | 302.3. | | | 1ST ROUND OF COMMENTS. THE DECK CAD SHEET PROVIDED DOES | | | NOT INDICATE ANY INFORMATION ON THE DECK. SINCE IT IS A | | | WOOD DECK IT IS ALSO A RAISED DECK. NO INFORMATION IS | | | GIVEN AS TO THE FOUNDATION OF THE DECK, SIZE OF FOOTERS | | | & REINFORCING, IF VERTICAL PIERS WERE USED, A FRAMING | | | MEMBER OF THE RIM JOIST, FLOOR JOIST, IF PRESSURE | | | TREATED, SIZE, SPACING, SPAN, GRADE OF LUMBER, IF | | | MID-SPAN BLOCKING WAS INSTALLED, STRAPS FROM THE | | | FOUNDATION TO FRAMING MEMBERS, TYPE OF LUMBER IF | | | PRESSURE TREATED, USED FOR THE DECKING MATERIAL, SIZE | | | OF DECK MEMBERS. | | | | | | 6A) COMPLIED A-3 OCCUPANCY. | | | | | | 6B) NO RESPONSE. IS THIS TO BE CONSIDERED AN A2 | | | OCCUPANCY WHERE DRINKS ARE TO BE SERVED? 107.2.1.2. | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 7) 3RD REQUEST, NO RESPONSE. PLEASE ALSO REVIEW IN THE | | | 2020 FBC-B TABLE 1607.1(4) LIVE LOADS FOR ASSEMBLY | | | USAGE @ 150 PSF FOR PLATFORMS. PLEASE ALSO NOTE THESE | | | PLANS WILL NEED TO BE COMPLETED BY AN ENGINEER FOR THE | | | LOADING AND SPACING OF ALL FRAMING MEMBERS. | | | | | | 8) 2ND REQUEST, NO RESPONSE. 5A-5D. THE PLANS DO NOT | | | INDICATE COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY | | | CODE FOR ACCESSIBILITY, RAMPS WILL BE REQUIRED 1 | | | POSSIBLE 2 IF THE OCCUPANT LOAD IS OVER 49 OCCUPANTS. | | | RAMPS WILL NEED TO SHOW COMPLIANCE WITH THE 2020 | | | FBC-ACCESSIBILITY CODE AND SECTIONS OF 405 OF THE | | | ACCESSIBILITY CODE INCLUDING HANDRAILS AND EDGE | | | PROTECTION. | | | | | | 9) 2ND REQUEST. SEE COMMENT 5D. PLEASE ALSO INCLUDE IN | | | THE DRAWINGS AN END DETAIL OR CUT SECTION THROUGH THE | | | DECKING MATERIAL TO SHOW HOW CLOSE THE WOOD DECKING | | | MEMBERS ARE TO EACH OTHER. PLEASE ALSO TAKE INTO | | | ACCOUNT THE SHRINKAGE FACTOR OF WOOD DECKS AND THE | | | SOUTH FLORIDA SUN. PLEASE SHOW COMPLIANCE WITH THE 2020 | | | FBC-ACCESSIBILITY CODE SECTION 302. 3 ELONGATED | | | OPENINGS IN FLOORING. | | | | | | 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | | RETIRED. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-11-01 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-11-01 09:13:57 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21041308 | | | ADD: 3700 S. DIXIE HWY. | | | CONT: FOWLER BUILDING COMPANY | | | TEL: 772-486-5350 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: 1101/2021 | | | ACTION: DENIED | | | | | | 1) 2ND REQUEST. WITH THE INCREASE IN THE VALUE OF | | | $4,200.00 + $2,400.00 = $6, 600.00 DOLLARS OF VALUE THE | | | VALUE STILL SEAMS LOW. | | | 1ST ROUND OF COMMENTS. WITH THE VALUE OF JOB. 109.3 | | | BUILDING PERMIT VALUATION. IF, IN THE OPINION OF THE | | | BUILDING OFFICIAL, THE CLAIMED VALUATION OF BUILDING, | | | ALTERATION APPEARS TO BE UNDERESTIMATED ON THE | | | APPLICATION, THE PERMIT SHALL BE DENIED. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ARCHITECTURAL AND DESIGN FEES, MARKETING | | | COST, OVERHEAD AND PROFIT, EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS | | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | | CONGRESS. | | | | | | 2) 2ND REQUEST. PLEASE HAVE A SURVEYOR UPDATE THEIR | | | SURVEY SHOWING THE LOCATION OF THE NEW DECK WITH | | | DIMENSIONS OF THE DECK AND TO THE PROPERTY LINE. | | | THE SURVEY DOES NOT SHOW THE PROPOSED DECK LOCATION ON | | | THE SURVEY. IF THIS IS AN EXISTING DECK AND REPAIR IT | | | SHOULD HAVE SHOWN UP ON THE SURVEY. 107.2.1.2 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 3) 2ND REQUEST. THE VERSION 2 OF THE APPLICATION THE | | | DESCRIPTION OF WORK IS LEFT BLANK, PLEASE UPDATE NEW | | | WOOD DECK REAR OF BUILDING, PROVIDE THE SQ. FOOT AREA | | | OF NEW DECK. | | | LOOKING THROUGH COMMUNITY PLUS BACK TO 2004 FOR THE | | | ADDRESS 3700 S. DIXIE HWY. THERE WAS NEVER A PERMIT | | | PULLED FOR ANY DECK CONSTRUCTION. THE SURVEY WAS DATED | | | 2/03/2010 AND NOTED A PAVER BRICK PATIO. WITH NO PERMIT | | | PULLED THIS IS AN ILLEGAL DECK TO BE CONSIDERED NEW | | | WORK. | | | 2020 EXISTING BUILDING CODE LEVEL II 801.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. CREATION OR EXTENSION | | | OF NONCONFORMITY. ALL NEW WORK, RE-CONFIGURATION SHALL | | | NOT CREATE OR EXTEND ANY NONCONFORMITY IN THE EXISTING | | | BUILDING TO WHICH THE RE-CONFIGURATION OF SPACE IS | | | BEING MADE WITH REGARD TO ACCESSIBILITY, STRUCTURAL | | | STRENGTH, FIRE SAFETY, MEANS OF EGRESS, OR THE CAPACITY | | | OF MECHANICAL, PLUMBING, OR ELECTRICAL SYSTEMS. | | | | | | 4) 2ND REQUEST. PLEASE SUBMIT A SITE PLAN SHOWING THE | | | LOCATION OF THE BUILDING, IDENTIFY THE TENANT SPACE # 3 | | | SINCE THIS PERMIT IS BEING PULLED UNDER THAT TENANT | | | ADDRESS. PLEASE ALSO INCLUDE A LETTER FROM THE OWNERS | | | (MARA MANAGEMENT LLC) ON THE OWNERS LETTERHEAD THEIR | | | APPROVAL OF THE DECK (PROVIDE SQUARE FEET OF DECK) AND | | | THEIR NOTARIZED SIGNATURE SINCE THE DECK LOCATION IS | | | PAST THE TENANT WALLS/ AREA. 107.2.1.2. ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 5) 2ND ROUND OF COMMENTS. RUSH DECK FLOOR PLAN. THE | | | FLOOR/ DECK PLAN. | | | | | | 5A) RUSH DECK FLOOR PLAN. THE FLOOR/ DECK PLAN | | | INDICATES THE OCCUPANCY TYPE AS A-3 ART GALLERY WITH | | | SEATING. OCCUPANT LOAD NOT GIVEN. 15 X51 = 765 SQ. FT. | | | 765/ 15= 51 OCCUPANTS. THE PLAN INDICATES THE DECK IS | | | RAISED 6 INCHES ABOVE GRADE. THE FLOOR PLAN DOES NOT | | | INDICATE IF THE NEW DECK IS THE SAME LEVEL AS THE | | | FINISH FLOOR FROM THE 4 DOORS THAT LEAD FROM THE | | | INTERIOR. IT IS ASSUMED TO GAIN ENTRY ONE HAS TO GO | | | THROUGH THE TENANT SPACE TO GET TO THE WOOD DECK. | | | PLEASE SHOW COMPLIANCE WITH 2020 FBC-ACCESS. CODE | | | CHANGES IN LEVEL 303.2 AND 303.3. WHERE CHANGES IN | | | LEVEL ARE PERMITTED IN THE FLOOR OR GROUND SURFACES, | | | THEY SHALL COMPLY WITH SECTION 303. SEE 303.1 & 303.2. | | | | | | 5B) IN CASE OF FIRE, ONE IS NOT TO GO BACK INTO THE | | | BUILDING, ONCE OUT OF THE BUILDING SECTION 1028.1 OF | | | THE 2020 FBC-B, THE EXIT DISCHARGE SHALL NOT REENTER | | | THE BUILDING. PLEASE SHOW THE 2 REQUIRED ACCESSIBLE | | | EXITS FROM THE DECK, THE PLANS DO NOT SHOW RAMPS NOR | | | HANDRAILS. 2020 FBC-ACCESSIBILITY CODE SECTION 207.1 | | | MEANS OF EGRESS SHALL COMPLY WITH SECTION 1003.2.13 OF | | | THE INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001 | | | SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL | | | BUILDING CODE (2003 EDITION). 2003 IBC-B 1007.1 WHERE | | | MORE THAN ONE MEANS OF EGRESS IS REQUIRED BY SECTIONS | | | 1014.1 OR 1018.1 FROM ANY ACCESSIBLE SPACE, EACH | | | ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY NOT | | | LESS THAN TWO MEANS OF EGRESS. | | | | | | 5C) THE DECK FLOOR PLAN DATED 10/29/2021 SHOWS A DECK | | | FRAMING PLAN BUT NO RAMPS FOR EGRESS. SHOW COMPLIANCE | | | WITH THE 2020 FBC-ACCESSIBILITY CODE SECTIONS 405.1 | | | THROUGH 405.10. | | | | | | 5D) THE DECK FLOOR PLAN DATED 10/29/2021 SHOWS A DECK | | | FRAMING DETAIL AND CUT SECTION DETAIL SHOWING THE | | | DECKING TO BE 5/4 PT DECKING. WHAT IS MISSING IS THE | | | SPACING BETWEEN BOARDS. NOTE THAT THE PT DECKING WILL | | | SHRINK MAKING THE SPACE BETWEEN THE DECK BOARDS TO | | | EXPAND WITH AGE. PLEASE PROVIDE WHAT THE ACTUAL SPACING | | | IS BETWEEN THE DECK BOARDS, AND DO THEY COMPLY WITH THE | | | 2020 FBC-ACCESIBILITY CODE SECTION 302.3. | | | 1ST ROUND OF COMMENTS. THE DECK CAD SHEET PROVIDED DOES | | | NOT INDICATE ANY INFORMATION ON THE DECK. SINCE IT IS A | | | WOOD DECK IT IS ALSO A RAISED DECK. NO INFORMATION IS | | | GIVEN AS TO THE FOUNDATION OF THE DECK, SIZE OF FOOTERS | | | & REINFORCING, IF VERTICAL PIERS WERE USED, A FRAMING | | | MEMBER OF THE RIM JOIST, FLOOR JOIST, IF PRESSURE | | | TREATED, SIZE, SPACING, SPAN, GRADE OF LUMBER, IF | | | MID-SPAN BLOCKING WAS INSTALLED, STRAPS FROM THE | | | FOUNDATION TO FRAMING MEMBERS, TYPE OF LUMBER IF | | | PRESSURE TREATED, USED FOR THE DECKING MATERIAL, SIZE | | | OF DECK MEMBERS. | | | | | | 6A) SEMI-COMPLIED. THE PLAN IS ALSO SILENT AS TO WHAT | | | OCCUPANT LOAD FACTOR WAS USED FOR AN OCCUPANT LOAD | | | SINCE THIS PLAN NEEDS TO SHOW IT IS UNDER THE 2020 | | | FBC-B NOTE SO ON THE PLAN. THE OCCUPANCY NEEDS TO BE | | | DETERMINED. SINCE IT CAME IN UNDER TENANT SPACE 3, SEAN | | | RUSH ATELIER INC. AN ART GALLERY IS THIS AREA TO BE | | | CONSIDERED AN ASSEMBLY AREA? WITH SEATING PLEASE | | | PROVIDE THE OCCUPANT LOADS USING TABLE 1004.5 FOR | | | STANDING AND FOR BENCH SEATING. | | | | | | 6B) SEMI-COMPLIED. IS THIS TO BE CONSIDERED AN A2 | | | OCCUPANCY WHERE DRINKS ARE TO BE SERVED? 107.2.1.2. | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 7) 2ND REQUEST. PLEASE ALSO REVIEW IN THE 2020 FBC-B | | | TABLE 1607.1(4) LIVE LOADS FOR ASSEMBLY USAGE @ 150 PSF | | | FOR PLATFORMS. PLEASE ALSO NOTE THESE PLANS WILL NEED | | | TO BE COMPLETED BY AN ENGINEER FOR THE LOADING AND | | | SPACING OF ALL FRAMING MEMBERS. | | | | | | 8) SEE COMMENTS 5A-5D. THE PLANS DO NOT INDICATE | | | COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY CODE FOR | | | ACCESSIBILITY, RAMPS WILL BE REQUIRED 1 POSSIBLE 2 IF | | | THE OCCUPANT LOAD IS OVER 49 OCCUPANTS. RAMPS WILL NEED | | | TO SHOW COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY CODE | | | AND SECTIONS OF 405 OF THE ACCESSIBILITY CODE INCLUDING | | | HANDRAILS AND EDGE PROTECTION. | | | | | | 9) SEE COMMENT 5D. PLEASE ALSO INCLUDE IN THE DRAWINGS | | | AN END DETAIL OR CUT SECTION THROUGH THE DECKING | | | MATERIAL TO SHOW HOW CLOSE THE WOOD DECKING MEMBERS ARE | | | TO EACH OTHER. PLEASE ALSO TAKE INTO ACCOUNT THE | | | SHRINKAGE FACTOR OF WOOD DECKS AND THE SOUTH FLORIDA | | | SUN. PLEASE SHOW COMPLIANCE WITH THE 2020 | | | FBC-ACCESSIBILITY CODE SECTION 302. 3 ELONGATED | | | OPENINGS IN FLOORING. | | | | | | 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | | RETIRED. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-06-03 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-06-03 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2021-06-03 12:33:39 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21041308 | | | ADD: 3700 S. DIXIE HWY. | | | CONT: FOWLER BUILDING COMPANY | | | TEL: 772-486-5350 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: 6/03/2021 | | | ACTION: DENIED | | | | | | 1) VALUE OF JOB. 109.3 BUILDING PERMIT VALUATION. IF, | | | IN THE OPINION OF THE BUILDING OFFICIAL, THE CLAIMED | | | VALUATION OF BUILDING, ALTERATION APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | | AND SYSTEMS SHALL BE TOTAL REPLACEMENT PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL | | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ARCHITECTURAL | | | AND DESIGN FEES, MARKETING COST, OVERHEAD AND PROFIT, | | | EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY | | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, | | | MEANS, ETC.) WITH REGIONAL ADJUSTMENTS FOR LOCATION AS | | | PUBLISHED BY THE INTERNATIONAL CODE CONGRESS. | | | | | | 2) THE SURVEY DOES NOT SHOW THE PROPOSED DECK LOCATION | | | ON THE SURVEY. IF THIS IS AN EXISTING DECK AND REPAIR | | | IT SHOULD HAVE SHOWN UP ON THE SURVEY. 107.2.1.2 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 3) LOOKING THROUGH COMMUNITY PLUS BACK TO 2004 FOR THE | | | ADDRESS 3700 S. DIXIE HWY. THERE WAS NEVER A PERMIT | | | PULLED FOR ANY DECK CONSTRUCTION. THE SURVEY WAS DATED | | | 2/03/2010 AND NOTED A PAVER BRICK PATIO. WITH NO PERMIT | | | PULLED THIS IS AN ILLEGAL DECK TO BE CONSIDERED NEW | | | WORK. | | | 2020 EXISTING BUILDING CODE LEVEL II 801.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. CREATION OR EXTENSION | | | OF NONCONFORMITY. ALL NEW WORK, RE-CONFIGURATION SHALL | | | NOT CREATE OR EXTEND ANY NONCONFORMITY IN THE EXISTING | | | BUILDING TO WHICH THE RE-CONFIGURATION OF SPACE IS | | | BEING MADE WITH REGARD TO ACCESSIBILITY, STRUCTURAL | | | STRENGTH, FIRE SAFETY, MEANS OF EGRESS, OR THE CAPACITY | | | OF MECHANICAL, PLUMBING, OR ELECTRICAL SYSTEMS. | | | | | | 4) PLEASE SUBMIT A SITE PLAN SHOWING THE LOCATION OF | | | THE BUILDING, IDENTIFY THE TENANT SPACE # 3 SINCE THIS | | | PERMIT IS BEING PULLED UNDER THAT TENANT ADDRESS. | | | PLEASE ALSO INCLUDE A LETTER FROM THE OWNERS (MARA | | | MANAGEMENT LLC) ON THE OWNERS LETTERHEAD THEIR APPROVAL | | | OF THE DECK ( PROVIDE SQUARE FEET OF DECK) AND THEIR | | | NOTARIZED SIGNATURE. 107.2.1.2. ADDITIONAL INFORMATION | | | IS REQUIRED. | | | | | | 5) THEE DECK CAD SHEET PROVIDED DOES NOT INDICATE ANY | | | INFORMATION ON THE DECK. SINCE IT IS A WOOD DECK IT IS | | | ALSO A RAISED DECK. NO INFORMATION IS GIVEN AS TO THE | | | FOUNDATION OF THE DECK, SIZE OF FOOTERS & REINFORCING, | | | IF VERTICAL PIERS WERE USED, A FRAMING MEMBER OF THE | | | RIM JOIST, FLOOR JOIST, IF PRESSURE TREATED, SIZE, | | | SPACING, SPAN, GRADE OF LUMBER, IF MID-SPAN BLOCKING | | | WAS INSTALLED, STRAPS FROM THE FOUNDATION TO FRAMING | | | MEMBERS, TYPE OF LUMBER IF PRESSURE TREATED, USED FOR | | | THE DECKING MATERIAL, SIZE OF DECK MEMBERS. | | | | | | 6A) THE PLAN IS ALSO SILENT AS TO WHAT OCCUPANT LOAD | | | FACTOR WAS USED FOR AN OCCUPANT LOAD SINCE THIS PLAN | | | NEEDS TO SHOW IT IS UNDER THE 2020 FBC-B NOTE SO ON THE | | | PLAN. THE OCCUPANCY NEEDS TO BE DETERMINED. SINCE IT | | | CAME IN UNDER TENANT SPACE 3, SEAN RUSH ATELIER INC. AN | | | ART GALLERY IS THIS AREA TO BE CONSIDERED AN ASSEMBLY | | | AREA? WITH SEATING PLEASE PROVIDE THE OCCUPANT LOADS | | | USING TABLE 1004.5 FOR STANDING AND FOR BENCH SEATING. | | | | | | 6B) IS THIS TO BE CONSIDERED AN A2 OCCUPANCY WHERE | | | DRINKS ARE TO BE SERVED? 107.2.1.2. ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 7) PLEASE ALSO REVIEW IN THE 2020 FBC-B TABLE 1607.1(4) | | | LIVE LOADS FOR ASSEMBLY USAGE @ 150 PSF FOR PLATFORMS. | | | PLEASE ALSO NOTE THESE PLANS WILL NEED TO BE COMPLETED | | | BY AN ENGINEER FOR THE LOADING AND SPACING OF ALL | | | FRAMING MEMBERS. | | | | | | 8) THE PLANS DO NOT INDICATE COMPLIANCE WITH THE 2020 | | | FBC-ACCESSIBILITY CODE FOR ACCESSIBILITY, RAMPS WILL BE | | | REQUIRED 1 POSSIBLE 2 IF THE OCCUPANT LOAD IS OVER 49 | | | OCCUPANTS. RAMPS WILL NEED TO SHOW COMPLIANCE WITH THE | | | 2020 FBC-ACCESSIBILITY CODE AND SECTIONS OF 405 OF THE | | | ACCESSIBILITY CODE INCLUDING HANDRAILS AND EDGE | | | PROTECTION. | | | | | | 9) PLEASE ALSO INCLUDE IN THE DRAWINGS AN END DETAIL OR | | | CUT SECTION THROUGH THE DECKING MATERIAL TO SHOW HOW | | | CLOSE THE WOOD DECKING MEMBERS ARE TO EACH OTHER. | | | PLEASE ALSO TAKE INTO ACCOUNT THE SHRINKAGE FACTOR OF | | | WOOD DECKS AND THE SOUTH FLORIDA SUN. PLEASE SHOW | | | COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY CODE SECTION | | | 302. 3 ELONGATED OPENINGS IN FLOORING. | | | | | | 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | | RETIRED. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | 2021-05-21 12:54:53 | PLEASE CHECK THE USE OF THIS DECK. | | | THEY MAY NEED A CHANGE OF OCCUPANCY IF IT IS FOR | | | RESTAURANT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-01-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-01-18 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-01-11 |
Time |
08:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-01-05 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-01-05 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2021-12-15 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-11-06 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-11-06 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-10-21 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-06-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2021-05-21 |
Time |
12:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-01-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-01-18 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-01-18 17:16:59 | SHEET S-1 COMPLIES BUT THE SITE PLAN BY CONTRACTOR DOES | | | NOT COMPLY WITH CERTIFICATION BY CONTRACTOR. 107.3.4.3. | | | THE CONTRACTOR (QUALIFIER) THAT CREATED / DREW THE SET | | | OF PLANS WILL NEED TO IDENTIFY THEMSELVES AS THE AUTHOR | | | OF THE PLANS. PLEASE PRINT YOUR NAME, SIGN YOUR NAME | | | AND LICENSE NUMBER FOR THE TRADE YOU ARE LICENSED IN | | | AND PLANS DRAWN. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-11-01 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-06-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-06-03 |
Time |
12:34 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-03 12:34:35 | SEE BUILDING COMMENTS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-01-05 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-01-05 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-01-05 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-11-05 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2021-11-05 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-11-05 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2021-11-05 15:18:22 | 11/5/21- FAILED. SHOW THE LOCATION OF THE DECK WITH | | | SETBACKS FROM THE REAR PROPERTY LINE. CURRENT ZLDRS | | | REQUIRE A TWO FOOT SETBACK. | | | 2. IS ANY EXISTING LANDSCAPING IN THE REQUIRED FIVE | | | FOOT WIDE BUFFER BEING REMOVED. | | | | | | ANGELLA VANN, AICP | | | 561-822-1441 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-06-17 |
|
|
Cont ID |
|
| Sent By |
KALEXAND |
Date |
2021-06-17 |
Time |
19:07 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-06-17 |
Time |
19:07 |
Sent To |
I |
|
| Notes |
| 2021-06-17 19:08:53 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PLEASE ILLUSTRATE THE FOLLOWING ON THE SURVEY: | | | - LOCATION OF DECK | | | - DISTANCE FROM DECK TO PROPERTY LINES | | | _____________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
|