Plan Review Details - Permit 21041308
Plan Review Stops For Permit 21041308
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2022-01-10 Cont ID  
Sent By cpuell Date 2022-01-10 Time 17:05 Rev Time 0.00
Received By cpuell Date 2022-01-10 Time 17:05 Sent To  
Notes
2022-01-10 17:06:17AREA OF WORK WILL BE FOR SUITES 3, 4, 5 AND 6

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2021-12-15 Cont ID  
Sent By cpuell Date 2021-12-15 Time 16:09 Rev Time 0.00
Received By cpuell Date 2021-12-15 Time 16:09 Sent To  
Notes
2021-12-15 16:10:44WHICH SUITES WILL THIS DECK BE ATTACHED TO? SUITES
 1,2,3,4,5,6,7,8 AND 9. PLEASE RESPOND TO [email protected]
 OR CALL 561-805-6659

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-11-01 Cont ID  
Sent By cpuell Date 2021-11-01 Time 08:40 Rev Time 0.00
Received By cpuell Date 2021-11-01 Time 08:40 Sent To  
Notes
2021-11-01 08:44:04PLEASE PROVIDE A FLOOR PLAN SHOWING EVERY SUITE ON THAT
 FLOOR AS IT APPEARS THAT DEMISING WALLS HAVE BEEN
 REMOVED AND SUITES MAY NEED TO BE ELIMINATED OR
 CONSOLIDATED. PLEASE EMAIL TO [email protected] FOR
 FURTHER QUESTIONS YOU CAN ALSO CALL 561-805-6659

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2022-01-18 Cont ID  
Sent By jwitmer Date 2022-01-18 Time 17:25 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-01-18 17:15:24WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21041308
 ADD: 3700 S. DIXIE HWY. BEHIND UNIT 3
 CONT: FOWLER BUILDING COMPANY
 TEL: 772-486-5350
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 4TH REVIEW
 DATE: 01/18/ 2022
 ACTION: DENIED
  
 NOTICE: 4X FEE / NOTICE!!!!! FLORIDA STATUTE
 553.80(2)(B) WITH RESPECT TO EVALUATION OF DESIGN
 PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT FINDS
 IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE
 FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT
 DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE
 TIMES FOR FAILURE TO CORRECT A CODE VIOLATION
 SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION,
 INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION,
 STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING,
 VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS
 SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF
 THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO
 CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH
 TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED
 FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT
 OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS
 REVIEW.
  
 1-2) COMPLIED.
  
 3) SEMI-COMPLIED. 2020 EXISTING BUILDING CODE LEVEL II
 801.3 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING.
 CREATION OR EXTENSION OF NONCONFORMITY. ALL NEW WORK,
 RE-CONFIGURATION SHALL NOT CREATE OR EXTEND ANY
 NONCONFORMITY IN THE EXISTING BUILDING TO WHICH THE
 RE-CONFIGURATION OF SPACE IS BEING MADE WITH REGARD TO
 ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE SAFETY, MEANS
 OF EGRESS.
  
 4) COMPLIED.
  
 5) 4TH ROUND OF COMMENTS. RUSH DECK FLOOR PLAN. THE
 FLOOR/ DECK PLAN.
  
 5A) COMPLIED. ARCHITECT LETTER STATES NEW WOOD DECK
 SAME LEVEL AS THE INTERIOR FINISH FLOOR.
  
 5B) 4TH REQUEST. SEMI- COMPLIED. THE DECK FRAMING PLAN
 DOES NOT SHOW COMPLIANCE WITH %A BUT ARCHITECTS LETTER
 STATES THE NEW DECK IS THE SAME LEVEL AS THE INTERIOR
 FINISH FLOOR. THE S1 SHEET DOES ALSO SHOW WHAT APPEARS
 TO BE 2 EGRESS RAMPS DOWN TO GRADE BUT THERE IS ALSO A
 DETAIL OF A EXISTING BUILDING WALL, LANDING THEN RAMP
 DOWN TO GRADE. THAT DETAIL IS DRAWN AS IF YOU WERE
 GOING OUT OF THE BUILDING TO A LANDING THEN DOWN TO
 EXISTING PAVEMENT WHICH IS NOT THE CASE.
 THE 2NS ISSUE THAT WAS NOT ADDRESSED RAMPS WITH A
 HEIGHT GREATER THAN 6 INCHES REQUIRE HANDRAILS
 INCOMPLIANCE WITH 1012.8 OF THE 2020 FBC-BUILDING CODE.
 3RD REVIEW COMMENT. IN CASE OF FIRE, ONE IS NOT TO GO
 BACK INTO THE BUILDING, ONCE OUT OF THE BUILDING
 SECTION 1028.1 OF THE 2020 FBC-B, THE EXIT DISCHARGE
 SHALL NOT REENTER THE BUILDING. PLEASE SHOW THE 2
 REQUIRED ACCESSIBLE EXITS FROM THE DECK, THE PLANS DO
 NOT SHOW RAMPS NOR HANDRAILS. 2020 FBC-ACCESSIBILITY
 CODE SECTION 207.1 MEANS OF EGRESS SHALL COMPLY WITH
 SECTION 1003.2.13 OF THE INTERNATIONAL BUILDING CODE
 (2000 EDITION AND 2001 SUPPLEMENT) OR SECTION 1007 OF
 THE INTERNATIONAL BUILDING CODE (2003 EDITION). 2003
 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS IS
 REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY
 ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE
 SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS.
  
 5C) 4TH REQUEST. 3RD REQUEST. THE DECK FLOOR PLAN S-1
 SHOWS A DECK FRAMING PLAN AND RAMPS BUT NOT COMPLIANCE
 WITH THE 2020 FBC-ACCESSIBILITY CODE SECTIONS 405.1
 THROUGH 405.10.
  
 5D) PROVISO, TO BE VERIFIED IN THE FIELD. NO CUT
 SECTION DETAIL SHOWING THE DECKING TO BE 5/4 PT
 DECKING. WHAT IS MISSING IS THE SPACING BETWEEN BOARDS.
 NOTE THAT THE PT DECKING WILL SHRINK MAKING THE SPACE
 BETWEEN THE DECK BOARDS TO EXPAND WITH AGE. PLEASE
 PROVIDE WHAT THE ACTUAL SPACING IS BETWEEN THE DECK
 BOARDS, AND DO THEY COMPLY WITH THE 2020
 FBC-ACCESSIBILITY CODE SECTION 302.3.
  
 6A) COMPLIED A-3 OCCUPANCY.
  
 6B) COMPLIED.
  
 7) 4TH REQUEST. PLEASE ALSO REVIEW IN THE 2020 FBC-B
 TABLE 1607.1(4) LIVE LOADS FOR ASSEMBLY USAGE @ 150 PSF
 FOR PLATFORMS. PLEASE ALSO NOTE THESE PLANS WILL NEED
 TO BE COMPLETED BY AN ENGINEER FOR THE LOADING AND
 SPACING OF ALL FRAMING MEMBERS. RESPONSE INDICATES SEE
 S-1 FOR LOAD CALCULATIONS. WHERE?
  
 8) NEW COMMENT. MEETING WITH MR. RUSH MR. DYLAN AND
 MYSELF ON WED. DEC. 22ND AT CITY HALL BUILDING
 CONFERENCE ROOM 2:00PM TO DISCUSS THIS PERMIT
 (UNPERMITTED DECK) AND UNPERMITTED WORK ON THE INTERIOR
 OF UNIT 3. MR. DYLAN PULLED UP OLD PERMITS TO BE VIEWED
 ON THE BIG SCREEN TO SHOW THE LAST PERMITTED WORK
 VERSES WHAT IS THERE NOW. ISSUES THAT ARE OF CONCERN
 NEW UNDERGROUND PLUMBING, VENTING AND NEITHER OF THE
 RESTROOMS HAVE BEEN UPDATED FOR ACCESSIBILITY
 REQUIREMENTS.
  
 9) NEW COMMENT. WITH THE 2 UNITS THAT WERE THERE AND
 INCREASED OCCUPANT LOAD OF THE A3/ A2 ASSEMBLY USAGE ON
 THE INTERIOR AND NEW OCCUPANT LOAD ON THE RAISED DECK,
 EVEN IF ON GRADE AND THE SAME EXTERIOR AREA IS GOING TO
 USE THIS EXTERIOR AREA THE ADDITIONAL OCCUPANT LOAD
 WILL NEED TO BE SHOWN THAT THE EXISTING RESTROOM
 FACILITIES WILL SHOW COMPLIANCE WITH 2020 FBC-BUILDING
 CODE TABLE 2902.1.
  
 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-12-21 Cont ID  
Sent By jwitmer Date 2021-12-21 Time 14:45 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2021-12-21 14:45:37WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21041308
 ADD: 3700 S. DIXIE HWY.
 CONT: FOWLER BUILDING COMPANY
 TEL: 772-486-5350
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: 12/212021
 ACTION: DENIED
  
 NOTICE: 4X FEE / NOTICE!!!!! FLORIDA STATUTE
 553.80(2)(B) WITH RESPECT TO EVALUATION OF DESIGN
 PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT FINDS
 IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE
 FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT
 DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE
 TIMES FOR FAILURE TO CORRECT A CODE VIOLATION
 SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION,
 INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION,
 STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING,
 VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS
 SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF
 THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO
 CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH
 TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED
 FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT
 OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS
 REVIEW.
  
  
  
 1-2) COMPLIED.
  
 3) SEMI-COMPLIED. 2020 EXISTING BUILDING CODE LEVEL II
 801.3 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING.
 CREATION OR EXTENSION OF NONCONFORMITY. ALL NEW WORK,
 RE-CONFIGURATION SHALL NOT CREATE OR EXTEND ANY
 NONCONFORMITY IN THE EXISTING BUILDING TO WHICH THE
 RE-CONFIGURATION OF SPACE IS BEING MADE WITH REGARD TO
 ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE SAFETY, MEANS
 OF EGRESS.
  
 4) 3RD REQUEST. PLEASE SUBMIT A SITE PLAN SHOWING THE
 LOCATION OF THE BUILDING, IDENTIFY THE TENANT SPACE # 3
 SINCE THIS PERMIT IS BEING PULLED UNDER THAT TENANT
 ADDRESS. PLEASE ALSO INCLUDE A LETTER FROM THE OWNERS
 (MARA MANAGEMENT LLC) ON THE OWNER?S LETTERHEAD THEIR
 APPROVAL OF THE DECK (PROVIDE SQUARE FEET OF DECK) AND
 THEIR NOTARIZED SIGNATURE SINCE THE DECK LOCATION IS
 PAST THE TENANT LEASE WALL AREA. 107.2.1.2. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 5) 3RD ROUND OF COMMENTS. RUSH DECK FLOOR PLAN. THE
 FLOOR/ DECK PLAN.
  
 5A) 3RD REQUEST. RUSH DECK FLOOR PLAN. THE FLOOR/ DECK
 PLAN INDICATES THE OCCUPANCY TYPE AS A-3 ART GALLERY
 WITH SEATING. THE PLAN INDICATES THE DECK IS RAISED 6
 INCHES ABOVE GRADE. THE FLOOR PLAN DOES NOT INDICATE IF
 THE NEW DECK IS THE SAME LEVEL AS THE FINISH FLOOR FROM
 THE 4 DOORS THAT LEAD FROM THE INTERIOR. IT IS ASSUMED
 TO GAIN ENTRY ONE HAS TO GO THROUGH THE TENANT SPACE TO
 GET TO THE WOOD DECK. PLEASE SHOW COMPLIANCE WITH 2020
 FBC-ACCESS. CODE CHANGES IN LEVEL 303.2 AND 303.3.
 WHERE CHANGES IN LEVEL ARE PERMITTED IN THE FLOOR OR
 GROUND SURFACES, THEY SHALL COMPLY WITH SECTION 303.
 SEE 303.1 & 303.2.
  
 5B) 3RD REQUEST. IN CASE OF FIRE, ONE IS NOT TO GO BACK
 INTO THE BUILDING, ONCE OUT OF THE BUILDING SECTION
 1028.1 OF THE 2020 FBC-B, THE EXIT DISCHARGE SHALL NOT
 REENTER THE BUILDING. PLEASE SHOW THE 2 REQUIRED
 ACCESSIBLE EXITS FROM THE DECK, THE PLANS DO NOT SHOW
 RAMPS NOR HANDRAILS. 2020 FBC-ACCESSIBILITY CODE
 SECTION 207.1 MEANS OF EGRESS SHALL COMPLY WITH SECTION
 1003.2.13 OF THE INTERNATIONAL BUILDING CODE (2000
 EDITION AND 2001 SUPPLEMENT) OR SECTION 1007 OF THE
 INTERNATIONAL BUILDING CODE (2003 EDITION). 2003 IBC-B
 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS IS REQUIRED
 BY SECTIONS 1014.1 OR 1018.1 FROM ANY ACCESSIBLE SPACE,
 EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY
 NOT LESS THAN TWO MEANS OF EGRESS.
  
 5C) 3RD REQUEST. THE DECK FLOOR PLAN DATED 10/15/2021
 SHOWS A DECK FRAMING PLAN BUT NO RAMPS FOR EGRESS. SHOW
 COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY CODE
 SECTIONS 405.1 THROUGH 405.10.
  
 5D) 3RD REQUEST. THE DECK FLOOR PLAN DATED 10/15/2021
 SHOWS A DECK FRAMING DETAIL AND CUT SECTION DETAIL
 SHOWING THE DECKING TO BE 5/4 PT DECKING. WHAT IS
 MISSING IS THE SPACING BETWEEN BOARDS. NOTE THAT THE PT
 DECKING WILL SHRINK MAKING THE SPACE BETWEEN THE DECK
 BOARDS TO EXPAND WITH AGE. PLEASE PROVIDE WHAT THE
 ACTUAL SPACING IS BETWEEN THE DECK BOARDS, AND DO THEY
 COMPLY WITH THE 2020 FBC-ACCESSIBILITY CODE SECTION
 302.3.
 1ST ROUND OF COMMENTS. THE DECK CAD SHEET PROVIDED DOES
 NOT INDICATE ANY INFORMATION ON THE DECK. SINCE IT IS A
 WOOD DECK IT IS ALSO A RAISED DECK. NO INFORMATION IS
 GIVEN AS TO THE FOUNDATION OF THE DECK, SIZE OF FOOTERS
 & REINFORCING, IF VERTICAL PIERS WERE USED, A FRAMING
 MEMBER OF THE RIM JOIST, FLOOR JOIST, IF PRESSURE
 TREATED, SIZE, SPACING, SPAN, GRADE OF LUMBER, IF
 MID-SPAN BLOCKING WAS INSTALLED, STRAPS FROM THE
 FOUNDATION TO FRAMING MEMBERS, TYPE OF LUMBER IF
 PRESSURE TREATED, USED FOR THE DECKING MATERIAL, SIZE
 OF DECK MEMBERS.
  
 6A) COMPLIED A-3 OCCUPANCY.
  
 6B) NO RESPONSE. IS THIS TO BE CONSIDERED AN A2
 OCCUPANCY WHERE DRINKS ARE TO BE SERVED? 107.2.1.2.
 ADDITIONAL INFORMATION IS REQUIRED.
  
 7) 3RD REQUEST, NO RESPONSE. PLEASE ALSO REVIEW IN THE
 2020 FBC-B TABLE 1607.1(4) LIVE LOADS FOR ASSEMBLY
 USAGE @ 150 PSF FOR PLATFORMS. PLEASE ALSO NOTE THESE
 PLANS WILL NEED TO BE COMPLETED BY AN ENGINEER FOR THE
 LOADING AND SPACING OF ALL FRAMING MEMBERS.
  
 8) 2ND REQUEST, NO RESPONSE. 5A-5D. THE PLANS DO NOT
 INDICATE COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY
 CODE FOR ACCESSIBILITY, RAMPS WILL BE REQUIRED 1
 POSSIBLE 2 IF THE OCCUPANT LOAD IS OVER 49 OCCUPANTS.
 RAMPS WILL NEED TO SHOW COMPLIANCE WITH THE 2020
 FBC-ACCESSIBILITY CODE AND SECTIONS OF 405 OF THE
 ACCESSIBILITY CODE INCLUDING HANDRAILS AND EDGE
 PROTECTION.
  
 9) 2ND REQUEST. SEE COMMENT 5D. PLEASE ALSO INCLUDE IN
 THE DRAWINGS AN END DETAIL OR CUT SECTION THROUGH THE
 DECKING MATERIAL TO SHOW HOW CLOSE THE WOOD DECKING
 MEMBERS ARE TO EACH OTHER. PLEASE ALSO TAKE INTO
 ACCOUNT THE SHRINKAGE FACTOR OF WOOD DECKS AND THE
 SOUTH FLORIDA SUN. PLEASE SHOW COMPLIANCE WITH THE 2020
 FBC-ACCESSIBILITY CODE SECTION 302. 3 ELONGATED
 OPENINGS IN FLOORING.
  
 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-11-01 Cont ID  
Sent By jwitmer Date 2021-11-01 Time 09:14 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2021-11-01 09:13:57WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21041308
 ADD: 3700 S. DIXIE HWY.
 CONT: FOWLER BUILDING COMPANY
 TEL: 772-486-5350
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: 1101/2021
 ACTION: DENIED
  
 1) 2ND REQUEST. WITH THE INCREASE IN THE VALUE OF
 $4,200.00 + $2,400.00 = $6, 600.00 DOLLARS OF VALUE THE
 VALUE STILL SEAMS LOW.
 1ST ROUND OF COMMENTS. WITH THE VALUE OF JOB. 109.3
 BUILDING PERMIT VALUATION. IF, IN THE OPINION OF THE
 BUILDING OFFICIAL, THE CLAIMED VALUATION OF BUILDING,
 ALTERATION APPEARS TO BE UNDERESTIMATED ON THE
 APPLICATION, THE PERMIT SHALL BE DENIED. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT, EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 2) 2ND REQUEST. PLEASE HAVE A SURVEYOR UPDATE THEIR
 SURVEY SHOWING THE LOCATION OF THE NEW DECK WITH
 DIMENSIONS OF THE DECK AND TO THE PROPERTY LINE.
 THE SURVEY DOES NOT SHOW THE PROPOSED DECK LOCATION ON
 THE SURVEY. IF THIS IS AN EXISTING DECK AND REPAIR IT
 SHOULD HAVE SHOWN UP ON THE SURVEY. 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED.
  
 3) 2ND REQUEST. THE VERSION 2 OF THE APPLICATION THE
 DESCRIPTION OF WORK IS LEFT BLANK, PLEASE UPDATE NEW
 WOOD DECK REAR OF BUILDING, PROVIDE THE SQ. FOOT AREA
 OF NEW DECK.
 LOOKING THROUGH COMMUNITY PLUS BACK TO 2004 FOR THE
 ADDRESS 3700 S. DIXIE HWY. THERE WAS NEVER A PERMIT
 PULLED FOR ANY DECK CONSTRUCTION. THE SURVEY WAS DATED
 2/03/2010 AND NOTED A PAVER BRICK PATIO. WITH NO PERMIT
 PULLED THIS IS AN ILLEGAL DECK TO BE CONSIDERED NEW
 WORK.
 2020 EXISTING BUILDING CODE LEVEL II 801.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING. CREATION OR EXTENSION
 OF NONCONFORMITY. ALL NEW WORK, RE-CONFIGURATION SHALL
 NOT CREATE OR EXTEND ANY NONCONFORMITY IN THE EXISTING
 BUILDING TO WHICH THE RE-CONFIGURATION OF SPACE IS
 BEING MADE WITH REGARD TO ACCESSIBILITY, STRUCTURAL
 STRENGTH, FIRE SAFETY, MEANS OF EGRESS, OR THE CAPACITY
 OF MECHANICAL, PLUMBING, OR ELECTRICAL SYSTEMS.
  
 4) 2ND REQUEST. PLEASE SUBMIT A SITE PLAN SHOWING THE
 LOCATION OF THE BUILDING, IDENTIFY THE TENANT SPACE # 3
 SINCE THIS PERMIT IS BEING PULLED UNDER THAT TENANT
 ADDRESS. PLEASE ALSO INCLUDE A LETTER FROM THE OWNERS
 (MARA MANAGEMENT LLC) ON THE OWNERS LETTERHEAD THEIR
 APPROVAL OF THE DECK (PROVIDE SQUARE FEET OF DECK) AND
 THEIR NOTARIZED SIGNATURE SINCE THE DECK LOCATION IS
 PAST THE TENANT WALLS/ AREA. 107.2.1.2. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 5) 2ND ROUND OF COMMENTS. RUSH DECK FLOOR PLAN. THE
 FLOOR/ DECK PLAN.
  
 5A) RUSH DECK FLOOR PLAN. THE FLOOR/ DECK PLAN
 INDICATES THE OCCUPANCY TYPE AS A-3 ART GALLERY WITH
 SEATING. OCCUPANT LOAD NOT GIVEN. 15 X51 = 765 SQ. FT.
 765/ 15= 51 OCCUPANTS. THE PLAN INDICATES THE DECK IS
 RAISED 6 INCHES ABOVE GRADE. THE FLOOR PLAN DOES NOT
 INDICATE IF THE NEW DECK IS THE SAME LEVEL AS THE
 FINISH FLOOR FROM THE 4 DOORS THAT LEAD FROM THE
 INTERIOR. IT IS ASSUMED TO GAIN ENTRY ONE HAS TO GO
 THROUGH THE TENANT SPACE TO GET TO THE WOOD DECK.
 PLEASE SHOW COMPLIANCE WITH 2020 FBC-ACCESS. CODE
 CHANGES IN LEVEL 303.2 AND 303.3. WHERE CHANGES IN
 LEVEL ARE PERMITTED IN THE FLOOR OR GROUND SURFACES,
 THEY SHALL COMPLY WITH SECTION 303. SEE 303.1 & 303.2.
  
 5B) IN CASE OF FIRE, ONE IS NOT TO GO BACK INTO THE
 BUILDING, ONCE OUT OF THE BUILDING SECTION 1028.1 OF
 THE 2020 FBC-B, THE EXIT DISCHARGE SHALL NOT REENTER
 THE BUILDING. PLEASE SHOW THE 2 REQUIRED ACCESSIBLE
 EXITS FROM THE DECK, THE PLANS DO NOT SHOW RAMPS NOR
 HANDRAILS. 2020 FBC-ACCESSIBILITY CODE SECTION 207.1
 MEANS OF EGRESS SHALL COMPLY WITH SECTION 1003.2.13 OF
 THE INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001
 SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL
 BUILDING CODE (2003 EDITION). 2003 IBC-B 1007.1 WHERE
 MORE THAN ONE MEANS OF EGRESS IS REQUIRED BY SECTIONS
 1014.1 OR 1018.1 FROM ANY ACCESSIBLE SPACE, EACH
 ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY NOT
 LESS THAN TWO MEANS OF EGRESS.
  
 5C) THE DECK FLOOR PLAN DATED 10/29/2021 SHOWS A DECK
 FRAMING PLAN BUT NO RAMPS FOR EGRESS. SHOW COMPLIANCE
 WITH THE 2020 FBC-ACCESSIBILITY CODE SECTIONS 405.1
 THROUGH 405.10.
  
 5D) THE DECK FLOOR PLAN DATED 10/29/2021 SHOWS A DECK
 FRAMING DETAIL AND CUT SECTION DETAIL SHOWING THE
 DECKING TO BE 5/4 PT DECKING. WHAT IS MISSING IS THE
 SPACING BETWEEN BOARDS. NOTE THAT THE PT DECKING WILL
 SHRINK MAKING THE SPACE BETWEEN THE DECK BOARDS TO
 EXPAND WITH AGE. PLEASE PROVIDE WHAT THE ACTUAL SPACING
 IS BETWEEN THE DECK BOARDS, AND DO THEY COMPLY WITH THE
 2020 FBC-ACCESIBILITY CODE SECTION 302.3.
 1ST ROUND OF COMMENTS. THE DECK CAD SHEET PROVIDED DOES
 NOT INDICATE ANY INFORMATION ON THE DECK. SINCE IT IS A
 WOOD DECK IT IS ALSO A RAISED DECK. NO INFORMATION IS
 GIVEN AS TO THE FOUNDATION OF THE DECK, SIZE OF FOOTERS
 & REINFORCING, IF VERTICAL PIERS WERE USED, A FRAMING
 MEMBER OF THE RIM JOIST, FLOOR JOIST, IF PRESSURE
 TREATED, SIZE, SPACING, SPAN, GRADE OF LUMBER, IF
 MID-SPAN BLOCKING WAS INSTALLED, STRAPS FROM THE
 FOUNDATION TO FRAMING MEMBERS, TYPE OF LUMBER IF
 PRESSURE TREATED, USED FOR THE DECKING MATERIAL, SIZE
 OF DECK MEMBERS.
  
 6A) SEMI-COMPLIED. THE PLAN IS ALSO SILENT AS TO WHAT
 OCCUPANT LOAD FACTOR WAS USED FOR AN OCCUPANT LOAD
 SINCE THIS PLAN NEEDS TO SHOW IT IS UNDER THE 2020
 FBC-B NOTE SO ON THE PLAN. THE OCCUPANCY NEEDS TO BE
 DETERMINED. SINCE IT CAME IN UNDER TENANT SPACE 3, SEAN
 RUSH ATELIER INC. AN ART GALLERY IS THIS AREA TO BE
 CONSIDERED AN ASSEMBLY AREA? WITH SEATING PLEASE
 PROVIDE THE OCCUPANT LOADS USING TABLE 1004.5 FOR
 STANDING AND FOR BENCH SEATING.
  
 6B) SEMI-COMPLIED. IS THIS TO BE CONSIDERED AN A2
 OCCUPANCY WHERE DRINKS ARE TO BE SERVED? 107.2.1.2.
 ADDITIONAL INFORMATION IS REQUIRED.
  
 7) 2ND REQUEST. PLEASE ALSO REVIEW IN THE 2020 FBC-B
 TABLE 1607.1(4) LIVE LOADS FOR ASSEMBLY USAGE @ 150 PSF
 FOR PLATFORMS. PLEASE ALSO NOTE THESE PLANS WILL NEED
 TO BE COMPLETED BY AN ENGINEER FOR THE LOADING AND
 SPACING OF ALL FRAMING MEMBERS.
  
 8) SEE COMMENTS 5A-5D. THE PLANS DO NOT INDICATE
 COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY CODE FOR
 ACCESSIBILITY, RAMPS WILL BE REQUIRED 1 POSSIBLE 2 IF
 THE OCCUPANT LOAD IS OVER 49 OCCUPANTS. RAMPS WILL NEED
 TO SHOW COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY CODE
 AND SECTIONS OF 405 OF THE ACCESSIBILITY CODE INCLUDING
 HANDRAILS AND EDGE PROTECTION.
  
 9) SEE COMMENT 5D. PLEASE ALSO INCLUDE IN THE DRAWINGS
 AN END DETAIL OR CUT SECTION THROUGH THE DECKING
 MATERIAL TO SHOW HOW CLOSE THE WOOD DECKING MEMBERS ARE
 TO EACH OTHER. PLEASE ALSO TAKE INTO ACCOUNT THE
 SHRINKAGE FACTOR OF WOOD DECKS AND THE SOUTH FLORIDA
 SUN. PLEASE SHOW COMPLIANCE WITH THE 2020
 FBC-ACCESSIBILITY CODE SECTION 302. 3 ELONGATED
 OPENINGS IN FLOORING.
  
 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-06-03 Cont ID  
Sent By jwitmer Date 2021-06-03 Time 12:33 Rev Time 0.00
Received By jwitmer Date 2021-06-03 Time 10:33 Sent To  
Notes
2021-06-03 12:33:39WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21041308
 ADD: 3700 S. DIXIE HWY.
 CONT: FOWLER BUILDING COMPANY
 TEL: 772-486-5350
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: 6/03/2021
 ACTION: DENIED
  
 1) VALUE OF JOB. 109.3 BUILDING PERMIT VALUATION. IF,
 IN THE OPINION OF THE BUILDING OFFICIAL, THE CLAIMED
 VALUATION OF BUILDING, ALTERATION APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE TOTAL REPLACEMENT PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL
 REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ARCHITECTURAL
 AND DESIGN FEES, MARKETING COST, OVERHEAD AND PROFIT,
 EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY
 INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL
 CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT,
 MEANS, ETC.) WITH REGIONAL ADJUSTMENTS FOR LOCATION AS
 PUBLISHED BY THE INTERNATIONAL CODE CONGRESS.
  
 2) THE SURVEY DOES NOT SHOW THE PROPOSED DECK LOCATION
 ON THE SURVEY. IF THIS IS AN EXISTING DECK AND REPAIR
 IT SHOULD HAVE SHOWN UP ON THE SURVEY. 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED.
  
 3) LOOKING THROUGH COMMUNITY PLUS BACK TO 2004 FOR THE
 ADDRESS 3700 S. DIXIE HWY. THERE WAS NEVER A PERMIT
 PULLED FOR ANY DECK CONSTRUCTION. THE SURVEY WAS DATED
 2/03/2010 AND NOTED A PAVER BRICK PATIO. WITH NO PERMIT
 PULLED THIS IS AN ILLEGAL DECK TO BE CONSIDERED NEW
 WORK.
 2020 EXISTING BUILDING CODE LEVEL II 801.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING. CREATION OR EXTENSION
 OF NONCONFORMITY. ALL NEW WORK, RE-CONFIGURATION SHALL
 NOT CREATE OR EXTEND ANY NONCONFORMITY IN THE EXISTING
 BUILDING TO WHICH THE RE-CONFIGURATION OF SPACE IS
 BEING MADE WITH REGARD TO ACCESSIBILITY, STRUCTURAL
 STRENGTH, FIRE SAFETY, MEANS OF EGRESS, OR THE CAPACITY
 OF MECHANICAL, PLUMBING, OR ELECTRICAL SYSTEMS.
  
 4) PLEASE SUBMIT A SITE PLAN SHOWING THE LOCATION OF
 THE BUILDING, IDENTIFY THE TENANT SPACE # 3 SINCE THIS
 PERMIT IS BEING PULLED UNDER THAT TENANT ADDRESS.
 PLEASE ALSO INCLUDE A LETTER FROM THE OWNERS (MARA
 MANAGEMENT LLC) ON THE OWNERS LETTERHEAD THEIR APPROVAL
 OF THE DECK ( PROVIDE SQUARE FEET OF DECK) AND THEIR
 NOTARIZED SIGNATURE. 107.2.1.2. ADDITIONAL INFORMATION
 IS REQUIRED.
  
 5) THEE DECK CAD SHEET PROVIDED DOES NOT INDICATE ANY
 INFORMATION ON THE DECK. SINCE IT IS A WOOD DECK IT IS
 ALSO A RAISED DECK. NO INFORMATION IS GIVEN AS TO THE
 FOUNDATION OF THE DECK, SIZE OF FOOTERS & REINFORCING,
 IF VERTICAL PIERS WERE USED, A FRAMING MEMBER OF THE
 RIM JOIST, FLOOR JOIST, IF PRESSURE TREATED, SIZE,
 SPACING, SPAN, GRADE OF LUMBER, IF MID-SPAN BLOCKING
 WAS INSTALLED, STRAPS FROM THE FOUNDATION TO FRAMING
 MEMBERS, TYPE OF LUMBER IF PRESSURE TREATED, USED FOR
 THE DECKING MATERIAL, SIZE OF DECK MEMBERS.
  
 6A) THE PLAN IS ALSO SILENT AS TO WHAT OCCUPANT LOAD
 FACTOR WAS USED FOR AN OCCUPANT LOAD SINCE THIS PLAN
 NEEDS TO SHOW IT IS UNDER THE 2020 FBC-B NOTE SO ON THE
 PLAN. THE OCCUPANCY NEEDS TO BE DETERMINED. SINCE IT
 CAME IN UNDER TENANT SPACE 3, SEAN RUSH ATELIER INC. AN
 ART GALLERY IS THIS AREA TO BE CONSIDERED AN ASSEMBLY
 AREA? WITH SEATING PLEASE PROVIDE THE OCCUPANT LOADS
 USING TABLE 1004.5 FOR STANDING AND FOR BENCH SEATING.
  
 6B) IS THIS TO BE CONSIDERED AN A2 OCCUPANCY WHERE
 DRINKS ARE TO BE SERVED? 107.2.1.2. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 7) PLEASE ALSO REVIEW IN THE 2020 FBC-B TABLE 1607.1(4)
 LIVE LOADS FOR ASSEMBLY USAGE @ 150 PSF FOR PLATFORMS.
 PLEASE ALSO NOTE THESE PLANS WILL NEED TO BE COMPLETED
 BY AN ENGINEER FOR THE LOADING AND SPACING OF ALL
 FRAMING MEMBERS.
  
 8) THE PLANS DO NOT INDICATE COMPLIANCE WITH THE 2020
 FBC-ACCESSIBILITY CODE FOR ACCESSIBILITY, RAMPS WILL BE
 REQUIRED 1 POSSIBLE 2 IF THE OCCUPANT LOAD IS OVER 49
 OCCUPANTS. RAMPS WILL NEED TO SHOW COMPLIANCE WITH THE
 2020 FBC-ACCESSIBILITY CODE AND SECTIONS OF 405 OF THE
 ACCESSIBILITY CODE INCLUDING HANDRAILS AND EDGE
 PROTECTION.
  
 9) PLEASE ALSO INCLUDE IN THE DRAWINGS AN END DETAIL OR
 CUT SECTION THROUGH THE DECKING MATERIAL TO SHOW HOW
 CLOSE THE WOOD DECKING MEMBERS ARE TO EACH OTHER.
 PLEASE ALSO TAKE INTO ACCOUNT THE SHRINKAGE FACTOR OF
 WOOD DECKS AND THE SOUTH FLORIDA SUN. PLEASE SHOW
 COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY CODE SECTION
 302. 3 ELONGATED OPENINGS IN FLOORING.
  
 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
2021-05-21 12:54:53PLEASE CHECK THE USE OF THIS DECK.
 THEY MAY NEED A CHANGE OF OCCUPANCY IF IT IS FOR
 RESTAURANT.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-01-18 Cont ID  
Sent By jwitmer Date 2022-01-18 Time 17:27 Rev Time 0.00
Received By jwitmer Date 2022-01-11 Time 08:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-01-05 Cont ID  
Sent By vbroglia Date 2022-01-05 Time 10:15 Rev Time 0.00
Received By vbroglia Date 2021-12-15 Time 15:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-11-06 Cont ID  
Sent By lmarchan Date 2021-11-06 Time 17:36 Rev Time 0.00
Received By lmarchan Date 2021-10-21 Time 09:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2021-06-18 Time   Rev Time 0.00
Received By dbattles Date 2021-05-21 Time 12:48 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-01-18 Cont ID  
Sent By jwitmer Date 2022-01-18 Time 17:17 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-01-18 17:16:59SHEET S-1 COMPLIES BUT THE SITE PLAN BY CONTRACTOR DOES
 NOT COMPLY WITH CERTIFICATION BY CONTRACTOR. 107.3.4.3.
 THE CONTRACTOR (QUALIFIER) THAT CREATED / DREW THE SET
 OF PLANS WILL NEED TO IDENTIFY THEMSELVES AS THE AUTHOR
 OF THE PLANS. PLEASE PRINT YOUR NAME, SIGN YOUR NAME
 AND LICENSE NUMBER FOR THE TRADE YOU ARE LICENSED IN
 AND PLANS DRAWN.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2021-11-01 Cont ID  
Sent By jwitmer Date 2021-11-01 Time 09:14 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-06-03 Cont ID  
Sent By jwitmer Date 2021-06-03 Time 12:34 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2021-06-03 12:34:35SEE BUILDING COMMENTS.

Review Stop Z ZONING
Rev No 3 Status P Date 2022-01-05 Cont ID  
Sent By vbroglia Date 2022-01-05 Time 10:13 Rev Time 0.00
Received By vbroglia Date 2022-01-05 Time 10:13 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2021-11-05 Cont ID  
Sent By ajones Date 2021-11-05 Time 15:15 Rev Time 0.00
Received By ajones Date 2021-11-05 Time 15:15 Sent To  
Notes
2021-11-05 15:18:2211/5/21- FAILED. SHOW THE LOCATION OF THE DECK WITH
 SETBACKS FROM THE REAR PROPERTY LINE. CURRENT ZLDRS
 REQUIRE A TWO FOOT SETBACK.
 2. IS ANY EXISTING LANDSCAPING IN THE REQUIRED FIVE
 FOOT WIDE BUFFER BEING REMOVED.
  
 ANGELLA VANN, AICP
 561-822-1441
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2021-06-17 Cont ID  
Sent By KALEXAND Date 2021-06-17 Time 19:07 Rev Time 0.00
Received By kalexand Date 2021-06-17 Time 19:07 Sent To I
Notes
2021-06-17 19:08:53ZONING PLAN REVIEW
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PLEASE ILLUSTRATE THE FOLLOWING ON THE SURVEY:
 - LOCATION OF DECK
 - DISTANCE FROM DECK TO PROPERTY LINES
 _____________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALLY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG
 IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 KIZZI ALEXANDRE, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved