Plan Review Details - Permit 21041294
Plan Review Stops For Permit 21041294
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2021-07-07 Cont ID  
Sent By cpuell Date 2021-07-07 Time 10:14 Rev Time 0.00
Received By cpuell Date 2021-07-07 Time 10:14 Sent To  
Notes
2021-07-07 10:14:53HALF ADDRESS BEEN READDRESSED TO 322 WALTON BLVD, WORK
 TO BE DONE ON BOTH UNITS.

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2021-06-28 Cont ID  
Sent By cpuell Date 2021-06-28 Time 08:37 Rev Time 0.00
Received By cpuell Date 2021-06-28 Time 08:37 Sent To  
Notes
2021-06-28 08:38:16PREVIOUS COMMENTS NOT ADDRESSED, PLEASE HAVE OWNER
 CONTACT [email protected] OR CALL 561-805-6659 TO DISCUSS
 READDRESSING HALF ADDRESS.
 PLANS STATE THAT THE SCOPE OF WORK IS FOR UNIT A AND B,
 HOWEVER THESE ARE NOT THE CORRECT ADDRESSES FOR THIS
 DUPLEX. THE FRONT UNIT HAS AN ADDRESS OF 320 WALTON
 BLVD AND THE REAR UNIT IS 320 1/2 WALTON BLVD. HALF
 ADDRESSES HAVE TO BE READDRESSED TO ELIMINATE THEM.
 PLEASE COORDINATE WITH [email protected] OR CALL
 561-805-6659.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-06-22 Cont ID  
Sent By cpuell Date 2021-06-22 Time 13:02 Rev Time 0.00
Received By cpuell Date 2021-06-22 Time 13:02 Sent To  
Notes
2021-06-22 13:05:05PLANS STATE THAT THE SCOPE OF WORK IS FOR UNIT A AND B,
 HOWEVER THESE ARE NOT THE CORRECT ADDRESSES FOR THIS
 DUPLEX. THE FRONT UNIT HAS AN ADDRESS OF 320 WALTON
 BLVD AND THE REAR UNIT IS 320 1/2 WALTON BLVD. HALF
 ADDRESSES HAVE TO BE READDRESSED TO ELIMINATE THEM.
 PLEASE COORDINATE WITH [email protected] OR CALL
 561-805-6659.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-06-16 Cont ID  
Sent By shill Date 2021-06-16 Time 11:34 Rev Time 0.00
Received By shill Date 2021-06-16 Time 11:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-06-09 Cont ID  
Sent By jleahy Date 2021-06-09 Time 06:45 Rev Time 0.00
Received By jleahy Date 2021-06-03 Time 11:27 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2021-07-02 Cont ID  
Sent By ccole Date 2021-07-02 Time 19:13 Rev Time 0.00
Received By ccole Date 2021-07-02 Time 19:13 Sent To  
Notes
2021-07-02 19:15:25GAS PLANS NOT SUBMITTED- NO GAS REVIEW PERFORMED.
 PLUMBING PLAN HAS A NOTE INDICATING GAS TO BE UNDER
 SEPARATE PERMIT.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-06-09 Cont ID  
Sent By ccole Date 2021-06-09 Time 15:19 Rev Time 0.00
Received By ccole Date 2021-06-09 Time 15:19 Sent To  
Notes
2021-06-09 15:19:281ST REVIEW FBC-2020 RES. GAS
 PERMIT- 21041294
 6/9/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) A NEW GAS WATER HEATER IS SHOWN ON THE PLANS. PLEASE
 COMPLY WITH SECTION 107.3.5.3 (13) WPB AMENDMENTS TO
 THE FBC AND PROVIDE A GAS RISER DRAWING THAT INCLUDES
 ALL NEW AND EXISTING GAS PIPING AND APPLIANCES AT THE
 RESIDENCES- SECTION G2412.3 & G2412.4 FBC RES. REFER TO
 FBC RES. CHAPTER 24 FUEL GAS- THE RISER SHALL INDICATE:
 A) TYPE OF GAS- NATURAL OR LP.
 B) DELIVERY PRESSURE AT THE METER.
 C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 D) TYPES AND SIZES OF PIPING.
 E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE
 UNIONS.
 H) OUTLET PRESSURES AT REGULATORS.
 I) LOCATIONS AND TYPES OF PIPE SLEEVES.
 K) PIPE SIZING TABLES.
  
 2) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN FOR THE
 WATER HEATER LISTING MAKE AND MODEL, BTU LOAD, AND
 EFFICIENCY RATING- SECTION G2448.1. PLEASE SUBMIT
 MANUFACTURER'S SPECS FOR THE UNIT, AND SHOW THE
 REQUIRED INSTALLATION CLEARANCES ON THE PLANS.
  
 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL OTHER
 GAS-FIRED APPLIANCE- SECTION G2408.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2021-07-02 Time   Rev Time 0.00
Received By aoliver Date 2021-06-28 Time 07:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-06-16 Cont ID  
Sent By shill Date 2021-06-16 Time 11:35 Rev Time 0.00
Received By shill Date 2021-05-27 Time 12:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2021-06-03 Cont ID  
Sent By medwards Date 2021-06-03 Time 14:55 Rev Time 0.00
Received By medwards Date 2021-06-03 Time 14:40 Sent To  
Notes
2021-06-03 14:56:09THE DRAWINGS DO NOT INDICAT THAT ANY MECHANICAL WORK IS
 BEING DONE UNDER THIS PERMIT. ME

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-07-02 Cont ID  
Sent By ccole Date 2021-07-02 Time 19:13 Rev Time 0.00
Received By ccole Date 2021-07-02 Time 19:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-06-09 Cont ID  
Sent By ccole Date 2021-06-09 Time 14:49 Rev Time 0.00
Received By ccole Date 2021-06-09 Time 12:53 Sent To  
Notes
2021-06-09 14:49:241ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 21041294
 6/9/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE PLUMBING CONTRACTOR M. COSTA SHALL PROVIDE A
 SUB-PERMIT APPLICATION, AND SHALL ALSO PROVIDE HIS OR
 HER SIGNATURE ON THE PLUMBING PLANS- SECTION 105.1,
 107.2.1 WPB AMENDMENTS TO THE FBC AND FLORIDA STATUTES
 471.003(2)(H) & 471.025.
  
 2) PLEASE PROVIDE AN ITEMIZED SCOPE OF PLUMBING WORK
 OUTLINE FOR THE PROPOSED PROJECT- SECTION 107.2.1 WPB.
 LABEL THE PLUMBING FIXTURES AND PIPING SHOWN ON THE
 PLANS AND EITHER NEW OR EXISTING. PROVIDE A LIST OF
 PLUMBING FIXTURES AND APPLIANCES BEING REPLACED,
 RELOCATED, OR NEWLY INSTALLED- SECTION 107.2.1 WPB.
  
 3) PROVIDE A SANITARY DRAINAGE AND VENT ISOMETRIC
 DRAWING- SECTION 107.3.5.3 WPB AMENDMENTS TO THE FBC.
  
 4) IDENTIFY THE LOCATION OF THE REQUIRED CLEANOUT AT
 THE JUNCTION OF THE BUILDING AND SEWER DRAINS- SECTION-
 P3005.2.3 FBC RES.
  
 5) THE PLAN APPEARS TO SHOW 2 -INCH FIXTURE BRANCH
 DRAINS FROM THE WASHING MACHINES, HOWEVER 3-INCH DRAINS
 ARE REQUIRED- SECTION 406.2 FBC P.
  
 6) PLEASE NOTE THIS IS A MULTI-FAMILY DWELLING, AND A
 BACKFLOW PREVENTION ASSEMBLY IS REQUIRED AT THE POINT
 OF DELIVERY. PLEASE CLARIFY IF THERE IS AN EXISTING BF
 ASSEMBLY IN USE. THE TYPE OF BACKFLOW ASSEMBLY REQUIRED
 WILL BE DEPENDENT UPON THE DEGREE OF HAZARD POSED BY
 THE WATER USER. A REDUCED PRESSURE ZONE BACKFLOW DEVICE
 IS REQUIRED BY THE CITY OF WEST PALM CROSS UTILITIES
 DEPARTMENT AND THEIR CONNECTION CONTROL PROGRAM.
 PLEASE NOTE THAT A FL. LICENSED PLUMBING CONTRACTOR
 SHALL OBTAIN A SEPARATE PERMIT FOR INSTALLATION OF THE
 BACKFLOW PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB
 AND SEC. 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL
 BE TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT
 PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT.
 PLEASE CONTACT THE WPB UTILITIES CENTRAL OPERATIONS
 DEPT.AT 561-822-2210 FOR FURTHER INFORMATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2021-06-10 Cont ID  
Sent By rgathrig Date 2021-06-10 Time 10:38 Rev Time 0.00
Received By rgathrig Date 2021-06-10 Time 10:38 Sent To  
Notes
2021-06-10 10:39:15APPROVED FOR INSPECTIONS ONLY
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-06-16 Cont ID  
Sent By shill Date 2021-06-16 Time 11:34 Rev Time 0.00
Received By shill Date 2021-06-16 Time 11:34 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2021-06-16 Cont ID  
Sent By rthermid Date 2021-06-16 Time 11:34 Rev Time 0.00
Received By shill Date 2021-06-16 Time 11:34 Sent To  
Notes
2021-06-16 11:34:39NO WORK PROPOSED OUTSIDE OF THE BUILDING FOOTPRINT
  