Plan Review Details - Permit 21041115
| Plan Review Stops For Permit 21041115 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-04-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-04-27 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-04-27 |
Time |
13:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-04-22 |
Time |
06:16 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-04-22 |
Time |
06:11 |
Sent To |
|
|
| Notes |
| 2021-04-22 06:42:07 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | 1) THE SUBMITTED STRAPPING INFORMATION IS NOT CLEAR. | | | PROVIDE A STRUCTURAL CONNECTION DETAIL FOR THE TENT | | | FRAMING AND A TIE DOWN DETAIL WITH DESIGN CALCULATIONS. | | | 2) THE WINDLOAD INFORMATION AND THE UP TO DATE FLORIDA | | | BUILDING CODE CYCLE (FBC B 2020 7TH EDITION) NEEDS TO | | | BE INDICATED ON THE SUBMITTED INFORMATION. | | | 3) THE SUBMITTED ENGINEERING MUST BE DIGITALLY | | | SIGNED(THIRD PARTY VERIFIED) OR HAVE ORIGINAL | | | SIGNATURES & SEALS BY THE DESIGN PROFESSIONAL. | | | 4) PROVIDE A LAYOUT SHEET INCLUDING THE LOCATION OF | | | RESTROOMS. THE ACCESSIBLE RESTROOMS SHALL BE LOCATED | | | WITHIN 500' OF TENTS. | | | 5) IF THE TENT IS COVERED ON THE SIDES, PLEASE SHOW | | | LOCATION OF DOOR OPENINGS AND EGRESS PATH. | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-04-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-04-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-04-27 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-04-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-04-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-04-23 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2021-04-23 14:11:45 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THE DETAIL OF THE TENT, SEATING PLAN AND EXITS WERE | | | UNREADABLE. | | | | | | PLEASE PROVIDE A LARGER TENT PLAN CLEARLY SHOWING THE | | | FLOOR PLAN, EXITS IF ANY, EXIT SIGNS IF NEEDED, | | | GENERATOR LOCATION,FIRE EXTINGUSIHER LOCATIONS, ETC. | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-04-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
sholder |
Date |
2021-04-21 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
|