Plan Review Details - Permit 21041115
Plan Review Stops For Permit 21041115
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-04-27 Cont ID  
Sent By pvalenti Date 2021-04-27 Time 13:17 Rev Time 0.00
Received By pvalenti Date 2021-04-27 Time 13:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-04-22 Cont ID  
Sent By pvalenti Date 2021-04-22 Time 06:16 Rev Time 0.00
Received By pvalenti Date 2021-04-22 Time 06:11 Sent To  
Notes
2021-04-22 06:42:07PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 1) THE SUBMITTED STRAPPING INFORMATION IS NOT CLEAR.
 PROVIDE A STRUCTURAL CONNECTION DETAIL FOR THE TENT
 FRAMING AND A TIE DOWN DETAIL WITH DESIGN CALCULATIONS.
 2) THE WINDLOAD INFORMATION AND THE UP TO DATE FLORIDA
 BUILDING CODE CYCLE (FBC B 2020 7TH EDITION) NEEDS TO
 BE INDICATED ON THE SUBMITTED INFORMATION.
 3) THE SUBMITTED ENGINEERING MUST BE DIGITALLY
 SIGNED(THIRD PARTY VERIFIED) OR HAVE ORIGINAL
 SIGNATURES & SEALS BY THE DESIGN PROFESSIONAL.
 4) PROVIDE A LAYOUT SHEET INCLUDING THE LOCATION OF
 RESTROOMS. THE ACCESSIBLE RESTROOMS SHALL BE LOCATED
 WITHIN 500' OF TENTS.
 5) IF THE TENT IS COVERED ON THE SIDES, PLEASE SHOW
 LOCATION OF DOOR OPENINGS AND EGRESS PATH.
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-04-27 Cont ID  
Sent By pleduc Date 2021-04-27 Time   Rev Time 0.00
Received By pleduc Date 2021-04-27 Time 13:36 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-04-23 Cont ID  
Sent By pleduc Date 2021-04-23 Time   Rev Time 0.00
Received By pleduc Date 2021-04-23 Time 14:08 Sent To  
Notes
2021-04-23 14:11:45THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THE DETAIL OF THE TENT, SEATING PLAN AND EXITS WERE
 UNREADABLE.
  
 PLEASE PROVIDE A LARGER TENT PLAN CLEARLY SHOWING THE
 FLOOR PLAN, EXITS IF ANY, EXIT SIGNS IF NEEDED,
 GENERATOR LOCATION,FIRE EXTINGUSIHER LOCATIONS, ETC.
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2021-04-28 Time   Rev Time 0.00
Received By sholder Date 2021-04-21 Time 10:56 Sent To  
Notes
***NONE***