| Plan Review Stops For Permit 21041112 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
N |
Date |
2021-04-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-04-21 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-04-21 |
Time |
16:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-05-19 |
|
|
Cont ID |
|
| Sent By |
mcphers |
Date |
2021-05-19 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-05-19 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2021-05-19 12:23:19 | REVISION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DRAWING GA-1 SHOWS THE DWELLING EGRESS THROUGH THE | | | GARAGE - CANNOT HAVE EGRESS THROUGH A GARAGE - FBC | | | R311.1 MEANS OF EGRESS. | | | DWELLINGS SHALL BE PROVIDED WITH A MEANS OF EGRESS IN | | | ACCORDANCE WITH THIS SECTION. THE MEANS OF EGRESS SHALL | | | PROVIDE A CONTINUOUS AND UNOBSTRUCTED PATH OF VERTICAL | | | AND HORIZONTAL EGRESS TRAVEL FROM ALL PORTIONS OF THE | | | DWELLING TO THE REQUIRED EGRESS DOOR WITHOUT REQUIRING | | | TRAVEL THROUGH A GARAGE. THE REQUIRED EGRESS DOOR SHALL | | | OPEN DIRECTLY INTO A PUBLIC WAY OR TO A YARD OR COURT | | | THAT OPENS TO A PUBLIC WAY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-05-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-05-19 |
Time |
06:39 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-05-19 |
Time |
06:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-05-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-05-19 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-05-19 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2021-05-19 15:38:44 | GAS WAS PASSED UNDER PERMIT 20080654 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-02-24 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-02-24 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-02-24 |
Time |
06:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-02-19 |
Time |
15:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-05-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-20 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-26 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-05-19 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-05-19 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-05-19 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2021-05-19 17:00:15 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | MECHANICAL REVIEW DENIED: | | | | | | FBC B 107.2.1, PROVIDE MIORE INFORMATION SPECIFIC TO | | | MECHANICAL/A/C & ENERGY CALCS. ALSO PROVIDE DETAILS FOR | | | THE DRYER EXHAUST AND TERMINATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-05-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-05-19 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-05-19 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2021-05-19 15:39:12 | 05/19/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | | | | 1. ON SHEET A-1, THERE IS A NEW SINK WITH A WASHER AND | | | DRYER ADDED TO THE MAIN BUILDING PLEASE PROVIDE AN | | | ISOMETRIC SANITARY RISER DIAGRAM PER THE WPB AMENDMENTS | | | TO THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL PLUMBING. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION, | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2021-04-29 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2021-04-29 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2021-04-29 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-04-29 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2021-04-29 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2021-04-29 |
Time |
10:08 |
Sent To |
|
|
| Notes |
|
|