Plan Review Details - Permit 21041112
Plan Review Stops For Permit 21041112
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2021-04-21 Cont ID  
Sent By shill Date 2021-04-21 Time 16:28 Rev Time 0.00
Received By shill Date 2021-04-21 Time 16:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-05-19 Cont ID  
Sent By mcphers Date 2021-05-19 Time 12:23 Rev Time 0.00
Received By rmcphers Date 2021-05-19 Time 12:15 Sent To  
Notes
2021-05-19 12:23:19REVISION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) DRAWING GA-1 SHOWS THE DWELLING EGRESS THROUGH THE
 GARAGE - CANNOT HAVE EGRESS THROUGH A GARAGE - FBC
 R311.1 MEANS OF EGRESS.
 DWELLINGS SHALL BE PROVIDED WITH A MEANS OF EGRESS IN
 ACCORDANCE WITH THIS SECTION. THE MEANS OF EGRESS SHALL
 PROVIDE A CONTINUOUS AND UNOBSTRUCTED PATH OF VERTICAL
 AND HORIZONTAL EGRESS TRAVEL FROM ALL PORTIONS OF THE
 DWELLING TO THE REQUIRED EGRESS DOOR WITHOUT REQUIRING
 TRAVEL THROUGH A GARAGE. THE REQUIRED EGRESS DOOR SHALL
 OPEN DIRECTLY INTO A PUBLIC WAY OR TO A YARD OR COURT
 THAT OPENS TO A PUBLIC WAY.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-05-19 Cont ID  
Sent By jleahy Date 2021-05-19 Time 06:39 Rev Time 0.00
Received By jleahy Date 2021-05-19 Time 06:31 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2021-05-19 Cont ID  
Sent By lcrespo Date 2021-05-19 Time 15:38 Rev Time 0.00
Received By lcrespo Date 2021-05-19 Time 15:04 Sent To  
Notes
2021-05-19 15:38:44GAS WAS PASSED UNDER PERMIT 20080654

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2022-02-24 Cont ID  
Sent By amhamilt Date 2022-02-24 Time 16:34 Rev Time 0.00
Received By amhamilt Date 2022-02-24 Time 16:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-02-24 Cont ID  
Sent By shill Date 2022-02-24 Time 06:33 Rev Time 0.00
Received By shill Date 2022-02-19 Time 15:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-20 Cont ID  
Sent By cthroop Date 2021-05-20 Time 11:31 Rev Time 0.00
Received By cthroop Date 2021-04-26 Time 15:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-05-19 Cont ID  
Sent By pvalenti Date 2021-05-19 Time 16:56 Rev Time 0.00
Received By pvalenti Date 2021-05-19 Time 16:18 Sent To  
Notes
2021-05-19 17:00:15****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 MECHANICAL REVIEW DENIED:
  
 FBC B 107.2.1, PROVIDE MIORE INFORMATION SPECIFIC TO
 MECHANICAL/A/C & ENERGY CALCS. ALSO PROVIDE DETAILS FOR
 THE DRYER EXHAUST AND TERMINATION.

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-05-19 Cont ID  
Sent By lcrespo Date 2021-05-19 Time 15:38 Rev Time 0.00
Received By lcrespo Date 2021-05-19 Time 14:51 Sent To  
Notes
2021-05-19 15:39:1205/19/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
  
 1. ON SHEET A-1, THERE IS A NEW SINK WITH A WASHER AND
 DRYER ADDED TO THE MAIN BUILDING PLEASE PROVIDE AN
 ISOMETRIC SANITARY RISER DIAGRAM PER THE WPB AMENDMENTS
 TO THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL PLUMBING.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION,
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2021-04-29 Cont ID  
Sent By dbattles Date 2021-04-29 Time 10:00 Rev Time 0.00
Received By dbattles Date 2021-04-29 Time 10:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET