| Plan Review Stops For Permit 21040915 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-05-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-14 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-14 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2021-05-14 08:34:24 | WINDOWS AND DOORS UNDER PERMIT 21041400. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-05-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-13 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-13 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2021-05-13 16:43:18 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. CORRECTED | | | | | | 2. PROVIDE THE ROUGH OPENING AND DESIGN PRESSURES OF | | | THE PROPOSED SMALLER WINDOW OPENING. (NOT ADDRESSED) | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR THE NEW SMALLER | | | WINDOW. (NOT ADDRESSED) | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 4. CORRECTED | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-29 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-29 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2021-04-29 16:21:46 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE A FRAMING DETAIL FOR THE M-BED WINDOW BEING | | | FILLED IN AND THE ONE THAT'S BEING REDUCED IN SIZE. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PROVIDE THE ROUGH OPENING AND DESIGN PRESSURES OF | | | THE PROPOSED SMALLER WINDOW OPENING. | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR THE NEW SMALLER | | | WINDOW. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 4. DESIGNER SHALL PRINT THEIR NAME AND SIGN THE PLAN. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-05-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-05-10 |
Time |
06:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-05-10 |
Time |
06:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-04-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-04-19 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-04-19 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2021-04-19 13:23:09 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) NEED TO SHOW WIRES SIZES FOR SUB-FEEDERS 215.5 | | | | | | 2) NEED TO HAVE A CARBON MONOXIDE DETECTOR WITHIN 10' | | | OF SLEEPING AREAS FBC RESDIENTIAL R315 | | | | | | 3) NEED PANEL SCHEDULES. PROVIDE PANEL SCHEDULE | | | INDICATING ANY NEW OR ALTERED CIRCUITS, THE WIRE AND | | | BREAKER SIZE FOR THESE CIRCUITS, AND AFCI OR GFCI | | | PROTECTION WHERE APPLICABLE TO COMPLY WITH CODE. NEC | | | 210.8, 210.12, 215.5, | | | | | | 4) PLAN NEEDS TO BE SIGNED BY DESIGNER OF RECORD OR THE | | | ELECTRICAL CONTRACTOR. 107.2.1 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-05-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-05-14 |
Time |
06:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-05-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-13 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-07 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-04-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-29 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-16 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-05-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-08 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-08 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-04-19 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-04-19 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2021-04-19 17:30:22 | THE DESIGNER OF THE MECHANICAL DRAWING MUST PROVIDE A | | | TITLEBLOCK WITH THEIR PRINTED NAME AND SIGNATURE. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-05-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-05-14 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-05-14 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-05-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-05-08 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-05-08 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2021-05-08 08:58:49 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 21040915 | | | 5/8/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE PLUMBING SUB- CONTRACTOR JOHNATHAN MEJIA SHALL | | | PROVIDE HIS TITLE BLOCK, PRINTED NAME, AND SIGNATURE ON | | | THE SANITARY RISER DRAWING- SECTION 107.2.1 WPB, AND | | | FLORIDA STATUTES 471.003(2)(H) & 471.025. | | | | | | 2) PROVIDE SLAB REPAIR DETAILS- SECTION 107.2.1 WPB. | | | | | | 3) THE PLUMBING SCOPE OF WORK INDICATES OWNER SUPPLIED | | | PLUMBING FIXTURES. PLEASE ADD THE ESTIMATED VALUE OF | | | THE FIXTURES AND WATER HEATERS TO THE TOTAL COST OF THE | | | PROJECT. IF THE COSTS HAVE ALREADY BEEN ACCOUNTED FOR | | | IN THE MAIN VALUE PLEASE PROVIDE COPIES OF ITEMIZED | | | ESTIMATES AND/OR INVOICES TO VERIFY COSTS- SECTION | | | 109.3 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-04-20 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-04-20 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2021-04-20 17:44:22 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 21040915 | | | 4/20/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE PLUMBING PLAN IS INCOMPLETE. PLEASE PROVIDE THE | | | FOLLOWING LIST OF ITEMS PER SECTION 107.2.1 WPB: | | | | | | A) AN ITEMIZED SCOPE OF WORK FOR PLUMBING ALTERATIONS | | | INCLUDING A LIST OF NEW AND REPLACED PLUMBING FIXTURES | | | AND FAUCETS. | | | B) SANITARY DRAINAGE AND VENT ISOMETRIC DRAWINGS. | | | C) REVISE THE PLAN TO SHOW THE JUNCTION OF THE BUILDING | | | DRAIN AND SEWER LINE. | | | D) WATER HEATER EQUIPMENT SCHEDULE LISTING MAKE AND | | | MODEL, AND SUBMIT MANUFACTURER'S SPECIFICATIONS. | | | E) SHOWER PAN DETAIL. | | | | | | 2) THE PLUMBING SUB- CONTRACTOR OR QUALIFIER SHALL | | | PROVIDE HIS TITLE BLOCK, PRINTED NAME, AND SIGNATURE ON | | | THE REVISED PLUMBING PLAN- SECTION 107.2.1 WPB, AND | | | FLORIDA STATUTES 471.003(2)(H) & 471.025. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2021-05-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-07 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-07 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2021-04-16 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-04-16 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-04-16 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2021-04-16 16:14:47 | TECHNICAL EVALUATION REPORT PAPER ORIGINAL HAS ORIGINAL | | | SEAL AND SIGNATURE. EQ |
|
|