Plan Review Details - Permit 21040824
Plan Review Stops For Permit 21040824
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-05-17 Cont ID  
Sent By jwitmer Date 2021-05-17 Time 14:44 Rev Time 0.00
Received By jwitmer Date 2021-05-17 Time 14:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-04-29 Cont ID  
Sent By jwitmer Date 2021-04-29 Time 11:03 Rev Time 0.00
Received By jwitmer Date 2021-04-27 Time 08:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-05-21 Cont ID  
Sent By equinone Date 2021-05-21 Time 09:06 Rev Time 0.00
Received By equinone Date 2021-05-21 Time 09:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-04-28 Cont ID  
Sent By equinone Date 2021-04-28 Time 08:59 Rev Time 0.00
Received By equinone Date 2021-04-28 Time 08:50 Sent To  
Notes
2021-04-28 09:07:35FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW:
  
 1) CURRENT FBC AND NEC CODES IN EFFECT ARE FBC 2020 7TH
 EDITION AND NEC 2017. PLEASE UPDATE YOUR CODE
 REFERENCES ACCORDINGLY.
  
 2) E-200 (ELECTRICAL GENERAL NOTES). NEW FBC ENERGY
 CODE 2020 7TH EDITION R404.1 HAS BEEN CHANGED TO:
  
 "NOT LESS THAN 90 PERCENT OF THE LAMPS IN PERMANENTLY
 INSTALLED LUMINAIRES SHALL HAVE
 AN EFFICACY OF AT LEAST 45 LUMENS-PER-WATT OR SHALL
 UTILIZE LAMPS WITH AN EFFICACY OF NOT LESS THAN 65
 LUMENS-PER-WATT?.
  
 PLEASE UPDATE YOUR NOTES
  
  
 ENRIQUE QUINONEZ PE
 ELECTRICAL PLANS EXAMINER
 DEVELOPMENT SERVICES
 CITY OF WEST PAM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6746.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-05-21 Cont ID  
Sent By equinone Date 2021-05-21 Time 09:06 Rev Time 0.00
Received By equinone Date 2021-05-12 Time 13:48 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2021-04-29 Time 11:06 Rev Time 0.00
Received By cdecoeur Date 2021-04-15 Time 12:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-05-20 Cont ID  
Sent By ccole Date 2021-05-20 Time 11:06 Rev Time 0.00
Received By ccole Date 2021-05-20 Time 11:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-04-23 Cont ID  
Sent By ccole Date 2021-04-23 Time 16:29 Rev Time 0.00
Received By ccole Date 2021-04-23 Time 14:56 Sent To  
Notes
2021-04-23 16:29:521ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21040824
 4/23/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS A-200 & P-200: THE BATHTUB IS BEING CONVERTED
 INTO A SHOWER. PLEASE CORRECT THE NOTES BY THE FLOOR
 PLANS INDICATING THE SHOWER IS BEING REPLACED IN THE
 SAME LOCATION- SECTION 107.2.1 WPB.
  
 2) A-200 & P-200: THE PLAN INDICATES COMPLIANCE WITH
 FAIR HOUSING SPECIFICATION A FOR THE BATHTUB IN THE
 GUEST BATHROOM HOWEVER A SHOWER IS BEING INSTALLED.
 REFER TO PAGE 7.56 OF THE FAIR HOUSING DESIGN ACT
 MANUAL- "A 30-INCH X 48-INCH CLEAR FLOOR SPACE MUST BE
 PROVIDED AT SHOWER STALLS PARALLEL TO THE FIXTURE AND
 FLUSH WITH THE CONTROL WALL". THE PLAN IS INCORRECTLY
 SHOWING A CLEAR FLOOR SPACE FORWARD APPROACH WHICH IS
 NOT ACCEPTABLE.
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE BATHTUB/SHOWER CONVERSION, THE OWNER
 AND DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY
 PROVIDE A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD
 INDICATE ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES
 NOT MEET THE REQUIREMENTS OF THE FAIR HOUSING
 ACCESSIBILITY GUIDELINES, BUT WILL ALSO REQUIRE THE
 OWNER TO AGREE TO REVERT THE UNIT BACK TO COMPLIANCE AT
 TIME OF SALE IF SO REQUESTED BY THE BUYER. IF THIS
 OPTION IS CHOSEN, PLEASE SEND AN EMAIL TO [email protected]
 AND I WILL SEND A COPY OF THE FAIR HOUSING AFFIDAVIT.
  
 3) PROVIDE NOTES OR DETAILS INDICATING THE NEW SHOWER
 AND TUB AND SHOWER VALVES WILL BE IN COMPLIANCE WITH
 SECTIONS 412.3 - BALANCED PRESSURE, THERMOSTATIC OR
 COMBINATION BALANCED-PRESSURE/THERMOSTATIC VALVES THAT
 CONFROM TO THE REQUIRMENTS OF ASSE 1016/ASME
 A112.1016/CSA B125.16 OR ASME A112.18.1/CSA B125.1.
  
 4) ADVISORIES:
 REFER TO SECTION 1002.1 FBC P: THE HORIZONTAL DISTANCE
 FROM THE CENTERLINE OF THE NEW SHOWER DRAIN OUTLET TO
 THE CENTERLINE OF THE INLET OF THE EXISTING TRAP SHALL
 NOT EXCEED 30". PLEASE PLACE A NOTE ON THE PLAN
 INDICATING COMPLIANCE.
 RELOCATING THE BATHTUB TRAIN OUTLETS WILL REQUIRE THE
 FLOOR TO BE X-RAYED TO IN ORDER TO LOCATE REINFORCING
 STEEL OR POST STRESSED FLOOR TENDONS. PLEASE PLACE A
 NOTE ON THE PLANS TO VERIFY COMPLIANCE WILL BE MET-
 SECTION 1-07.2.1 WPB.
 NEW DRAIN PIPE PENETRATIONS OF THE EXISTING SLAB WILL
 REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE AROUND
 THE PIPING. PROVIDE A UL TESTED AND APPROVED
 FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SECTION 315.1
 FBC P, AND SECTION 714.4.1.2 FBC B.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-05-13 Cont ID  
Sent By medwards Date 2021-05-13 Time 06:50 Rev Time 0.00
Received By medwards Date 2021-05-13 Time 06:49 Sent To  
Notes
2021-05-13 06:50:54ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO
 STORAGE.ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-04-16 Cont ID  
Sent By equinone Date 2021-04-16 Time 13:15 Rev Time 0.00
Received By equinone Date 2021-04-16 Time 13:15 Sent To  
Notes
2021-04-16 13:15:55SEALED AND SIGNED PAPER ORIGINALS ROUTED TO INCOMING.
 EQ


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved