Plan Review Details - Permit 21040751
Plan Review Stops For Permit 21040751
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-04-23 Cont ID  
Sent By jgomez Date 2021-04-23 Time 10:45 Rev Time 0.00
Received By jgomez Date 2021-04-23 Time 09:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-04-16 Cont ID  
Sent By jgomez Date 2021-04-16 Time 14:55 Rev Time 0.00
Received By jgomez Date 2021-04-16 Time 14:01 Sent To  
Notes
2021-04-16 14:57:32RESIDENTIAL (R3) REVISION BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 REVISION # 21040751
  
 NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK
 SHALL COMPLY WITH THE MATERIALS AND METHODS
 REQUIREMENTS IN THE FLORIDA BUILDING CODE.
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE.
  
 1- THIS REVIEW WAS SUBMITTED AS A SUBMITTAL. BASED ON
 THE INFORMATION SUBMITTED THIS IS A REVISION TO THE
 MASTER NOT A SUBMITTAL. PLANS SUBMITTED DON'T MATCH THE
 APPROVED SET OF PLANS. NOTE: DRAWING NAMES DON'T MATCH
 THOSE OF THE APPROVED MASTER. PLEASE UPLOAD REVISED
 DRAWINGS USING THE SAME FILE NAME AS THE ORIGINAL ONES.
 THIS IS REQUIRED BECAUSE DRAWINGS WILL BE VERSIONED
 WITH THE APPROVED PLANS FOR PROPER REVIEW AND RECORDS
 KEEPING. (SEE QUICK START GUIDE: DIGITAL PLAN REVIEW).
 SEC. 107.2.1.3 CITY AMENDMENTS.
  
 2- ALL DRAWINGS WERE UPLOADED TO PROJECTDOX AS A SINGLE
 PDF. DRAWINGS NEED TO BE UPLOADED INDIVIDUALLY. PLEASE
 UPLOAD EACH DRAWING INDIVIDUALLY AS REQUIRED BY THE
 CITY REQUIREMENTS FOR DIGITAL PLAN REVIEW. ALSO,
 DRAWINGS NEED TO FOLLOW THE FILE NAMING GUIDELINES.
 COORDINATE WITH ITEM #1 ABOVE. SEE THE CITY QUICK START
 GUIDE: DIGITAL PLAN REVIEW.
 SEC. 107.2.1.3 CITY AMENDMENTS.
  
 3- ARCHITECTURAL DRAWINGS SUBMITTED DON'T HAVE A
 DIGITAL SIGNATURE. PLANS SUBMITTED HAVE A COPY OF THE
 ARCHITECT'S SEAL AND SIGNATURE. PLANS NEED TO HAVE
 ARCHITECT'S ORIGINAL SEAL AND SIGNATURE WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS AS REQUIRED BY 61G1-16.003
 FAC. PLANS WERE SUBMITTED ELECTRONICALLY. ARCHITECT TO
 PROVIDE PLANS WITH DIGITAL SIGNATURE(SEE COPY OF SEC.
 61G1-16.005 FOR DIGITAL SIGNATURE PROCEDURE) OR PROVIDE
 HARD COPY PLANS WITH THE ORIGINAL SEAL AND SIGNATURE.
  
 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 4- OWES $360.25 FOR REVISION FEES.
  
  
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-04-23 Cont ID  
Sent By jgomez Date 2021-04-23 Time 10:52 Rev Time 0.00
Received By jgomez Date 2021-04-20 Time 15:47 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-04-16 Cont ID  
Sent By jgomez Date 2021-04-16 Time 15:48 Rev Time 0.00
Received By jgomez Date 2021-04-14 Time 14:00 Sent To I
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-04-23 Cont ID  
Sent By jgomez Date 2021-04-23 Time 10:52 Rev Time 0.00
Received By jgomez Date 2021-04-23 Time 10:52 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-04-16 Cont ID  
Sent By jgomez Date 2021-04-16 Time 15:47 Rev Time 0.00
Received By jgomez Date 2021-04-16 Time 14:01 Sent To  
Notes
2021-04-16 15:47:55SIGNATURE REVIEW
  
 1- ARCHITECTURAL DRAWINGS SUBMITTED DON'T HAVE A
 DIGITAL SIGNATURE. PLANS SUBMITTED HAVE A COPY OF THE
 ARCHITECT'S SEAL AND SIGNATURE. PLANS NEED TO HAVE
 ARCHITECT'S ORIGINAL SEAL AND SIGNATURE WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS AS REQUIRED BY 61G1-16.003
 FAC. PLANS WERE SUBMITTED ELECTRONICALLY. ARCHITECT TO
 PROVIDE PLANS WITH DIGITAL SIGNATURE(SEE COPY OF SEC.
 61G1-16.005 FOR DIGITAL SIGNATURE PROCEDURE) OR PROVIDE
 HARD COPY PLANS WITH THE ORIGINAL SEAL AND SIGNATURE.
  
 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  