Plan Review Details - Permit 21040741
Plan Review Stops For Permit 21040741
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status N Date 2021-05-28 Cont ID  
Sent By cthroop Date 2021-05-28 Time 13:41 Rev Time 0.00
Received By cthroop Date 2021-05-28 Time 13:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-05-01 Cont ID  
Sent By cthroop Date 2021-05-01 Time 09:12 Rev Time 0.00
Received By cthroop Date 2021-05-01 Time 08:49 Sent To  
Notes
2021-05-01 09:14:29PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER PX3169 1&2 FAMILY - SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE A SITE PLAN. IDENTIFY WHICH STRUCTURE THIS
 PERMIT IS FOR,
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE
 SITE,... AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN
 ACCURATE AND INCLUDED BOUNDARY LINE SURVEY.
  
 2. PROVIDE A FLOOR PLAN. SHOW EXISTING WORK AND
 PROPOSED WORK.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2021-05-29 Cont ID  
Sent By fgiaquin Date 2021-05-29 Time 09:21 Rev Time 0.00
Received By fgiaquin Date 2021-05-29 Time 08:41 Sent To  
Notes
2021-05-29 09:21:04PREVIOUS PLAN REVIEW COMMENTS DO NOT APPLY. THIS IS A
 PLUMBING PERMIT MISTAKENLY LABELED AS A RES-REMODEL
 PERMIT. ANY ELECTRICAL FOR WATER HEATER WILL BE
 SUBMITTED BY SEPARATE ELECTRICAL CONTRACTOR.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2021-05-14 Cont ID  
Sent By fgiaquin Date 2021-05-14 Time 22:52 Rev Time 0.00
Received By fgiaquin Date 2021-05-14 Time 22:47 Sent To  
Notes
2021-05-14 22:52:33PREVIOUS PLAN REVIEW COMMENTS NOT SATISFIED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-04-19 Cont ID  
Sent By fgiaquin Date 2021-04-19 Time 23:09 Rev Time 0.00
Received By fgiaquin Date 2021-04-19 Time 22:09 Sent To  
Notes
2021-04-19 23:08:58ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE LOAD CALCULATION TO INCLUDE ALL LOADS, BOTH
 NEW AND EXISTING. NEC220
  
 2. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND
 SEALED BY A LICENSED DESIGN PROFESSIONAL OR SIGNED BY
 THE ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H);
 471.025; WPB FBC 107.2.1, 107.3.5
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-05-28 Cont ID  
Sent By cthroop Date 2021-05-28 Time 13:41 Rev Time 0.00
Received By cthroop Date 2021-05-13 Time 10:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-01 Cont ID  
Sent By cthroop Date 2021-05-01 Time 09:14 Rev Time 0.00
Received By cthroop Date 2021-04-13 Time 15:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-04-19 Cont ID  
Sent By lcrespo Date 2021-04-19 Time 11:03 Rev Time 0.00
Received By lcrespo Date 2021-04-19 Time 11:03 Sent To  
Notes
2021-04-19 11:16:3704/19/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-04-27 Cont ID  
Sent By lcrespo Date 2021-04-19 Time 11:04 Rev Time 0.00
Received By lcrespo Date 2021-04-19 Time 11:04 Sent To  
Notes
***NONE***