Plan Review Details - Permit 21040663
Plan Review Stops For Permit 21040663
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-04-14 Cont ID  
Sent By cpuell Date 2021-04-14 Time 15:59 Rev Time 0.00
Received By cpuell Date 2021-04-14 Time 15:59 Sent To  
Notes
2021-04-14 16:01:28BLDG SHELL BEING WORKED ON SPECIFICALLY SUITES B1, B3 &
 B5

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2021-07-13 Cont ID  
Sent By jwitmer Date 2021-07-13 Time 19:45 Rev Time 0.00
Received By jwitmer Date 2021-07-13 Time 19:16 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-06-23 Cont ID  
Sent By pvalenti Date 2021-06-23 Time 13:38 Rev Time 0.00
Received By pvalenti Date 2021-06-23 Time 13:18 Sent To  
Notes
2021-06-23 13:48:35****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 ASBESTOS REVIEW DENIED:
  
 THE DESIGN PROFESSIONAL'S RESPONSE HAS BEEN
 ACKNOWLEDGED. THE ASBESTOS ACKNOWLEDGEMENT
 (REQUIREMENTS NOTED BELOW) WILL NEED TO BE SUBMITTED BY
 THE CONTRACTOR, THAT IS STILL TO BE DETERMINED, PRIOR
 TO PERMIT ISSUANCE.
  
 ASBESTOS REQUIREMENTS:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-05-11 Cont ID  
Sent By jwitmer Date 2021-05-11 Time 11:27 Rev Time 0.00
Received By jwitmer Date 2021-05-11 Time 08:57 Sent To  
Notes
2021-05-11 11:27:24TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA
 PROJECTDOX. PLEASE INCLUDE "ASBESTOS" IN THE SUBJECT
 LINE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-07-13 Cont ID  
Sent By jwitmer Date 2021-07-13 Time 19:45 Rev Time 0.00
Received By jwitmer Date 2021-07-13 Time 19:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-06-23 Cont ID  
Sent By pvalenti Date 2021-06-23 Time 16:30 Rev Time 0.00
Received By pvalenti Date 2021-06-23 Time 13:18 Sent To  
Notes
2021-06-23 17:18:35****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 2ND BUILDING REVIEW DENIED:
  
 1) OK
 2A-D) OK
 3A-3G) OK
  
 3H) DENIED; SPOUT OUTLETS/ DRINKING FOUNTAINS. 2017
 ACCESS. CODE. SPOUT OUTLETS SHALL
 COMPLY WITH: 602.4 SPOUT HEIGHT. 36 INCHES MAXIMUM
 ABOVE THE FINISH FLOOR
 OR GROUND FOR WHEELCHAIR BOUND INDIVIDUALS. 602.7 SPOUT
 HEIGHT FOR THE
 STANDING PERSONS SHALL BE BETWEEN 38 TO 43 INCHES ABOVE
 FINISH FLOOR.
 6/23/21 DESIGN PROFESSIONAL'S RESPONS IS ACKNOWLEDGED.
 HOWEVER, AS PER FBC P 403.5, PLEASE INDICATE ON PLANS
 THAT THE MOST REMOTE LOCATION WITHIN THE TENANT SPACE
 IS NO MORE THAN 300' FROM A DRINKING FOUNTAIN ALONG AN
 ACCESSIBLE ROUTE.
  
 4) OK, DEFERRED SUBMITTAL AND SEPARATE PERMIT IS
 REQUIRED FOR AWNING & CANOPIES.
  
 5) DENIED: SUBMIT PRODUCT APPROVALS FOR, COMPONENTS AND
 CLADDING.
 THE DEMO SHEET NOTES 11 & 12 BOTH INDICATE THE REMOVAL
 OF STOREFRONT
 WINDOW AND DOOR SYSTEMS. SHEET A-550 SHOW ELEVATIONS OF
 THE NEW
 STOREFRONT SYSTEMS. SHEET S-200 SHOWS THE NEW
 STRUCTURAL STEEL FOR THE
 STOREFRONT SYSTEM AS WELL AS THE NEW STRUCTURAL STUDS
 FOR THE BLOCKED IN AREA
 OF STOREFRONT. COMPONENTS & CLADDING. 2020 FBC-B
 1609.1.2 PROTECTION OF
 OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA
 DEPARTMENT OF
 COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/
 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE
 PRODUCT APPROVALS: (31)(A) EXTERIOR DOORS, MULLIONS.
 (B) WINDOWS & MULLIONS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, EFIS
 SYSTEMS, (D) ROOFING PRODUCTS
 AND ASSEMBLIES, ROOF TOP CURBS FOR RTU UNITS,
 LIGHTWEIGHT CONCRETE INSULATION,
 ROOF TOP VENTILATORS.
 6/23/21, PLEASE PROVIDE ALL PRODUCT APPROVALS(WITH
 DESIGNER OF RECORD'S APPROVED REVIEW STAMPS) FOR ALL OF
 THE ABOVE NOTED ITEMS.
  
 6) DENIED; IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY
 ON THE PRODUCT
 APPROVAL BEFORE SUBMITTING TO DESIGNER OF RECORD AND
 BEFORE SUBMISSION TO
 THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING,
 PLEASE IDENTIFY THE
 OPENING WIDTH & HEIGHT, TYPE OF GLAZING, MULLION SIZE,
 LENGTH IF UNREINFORCED
 OR REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES
 FOR EACH OPENING SIZE. 2020 FBC-B 1405.13.1
 INSTALLATION. WINDOWS AND DOORS
 SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED
 MANUFACTURER?S INSTRUCTIONS.
 FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH
 INSTRUCTIONS AND SHALL BE
 CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN
 THE TESTS.
 6/23/21 PLEASE INDICATE, WITHIN THE SUBMITTED SHOP
 DRAWIMGS, THE SYSTEMS AND OPTIONS FOR STOREFRONT SYSTEM
 THAT WILL BE USED.
  
 7) DENIED; W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH
 ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE 61G20
 SHALL BE REVIEWED
 AND APPROVED IN WRITING (SHOP DRAWING STAMP OF
 APPROVAL) BY THE DESIGNER
 OF RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL
 APPROVAL. FL 61G1-23.015 (2) THE
 ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING
 ALL PROJECT DATA,
 REPORTS, SHOP DRAWINGS ETC.
 6/23/2021 PLEASE PROVIDE ALL SHOP DRAWINGS AND PRODUCT
 APPROVALS, INCLUDING THOSE THAT HAVE ALREADY BEEN
 SUBMITTED, WITH DESIGNER OF RECORD'S APPROVED REVIEW
 STAMP.
  
 8) OK, DEFERRED SUBMITTAL REQUIREMENT HAS BEEN
 ACKNOWLEDGED BY DESIGN PROFESSIONAL.
  
 9) OK
  
 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE
 YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-05-11 Cont ID  
Sent By jwitmer Date 2021-05-11 Time 11:28 Rev Time 0.00
Received By jwitmer Date 2021-05-11 Time 08:57 Sent To  
Notes
2021-05-11 11:26:00WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21040663
 ADD: 1885 PALM BEACH LAKES BLVD. # B1, B3 & B4
 CONT: TBD/ TO BE DETERMINED
 TEL:
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. MAY 11TH, 2021
 ACTION: DENIED
 1) BOTH THE PERMIT APPLICATION AND THE SET OF PLANS
 INDICATE WORK TO BE ACCOMPLISHED IN B01, B03 & B04
 UNITS. THE SUITES HAVE HAD TENANT ADDRESSES ASSIGNED TO
 THEM, PLEASE USE THESE ADDRESSES FOR FUTURE REFERENCES
 ON THE PLANS.
 2020 FBC-B 501.2 ADDRESS IDENTIFICATION. NEW AND
 EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED
 ADDRESS IDENTIFICATION.
 CITY MUNI CODE SEC.78-6 (1-7) (2) LOCATION, BUILDINGS
 CONTAINING MORE THAN ONE ADDRESS. ALL ADDRESSES SHALL
 BE POSTED ON THAT PORTION OF THE STRUCTURE FRONTING OR
 FACING UPON THE STREET OR PRINCIPAL VEHICULAR ACCESS TO
 THE PREMISES, SO AS TO BE READILY VISIBLE TO
 APPROACHING VEHICLES. THE PLACEMENT OF NUMBERS ON
 BUILDINGS OR FENCES, AS THE CASE MAY BE, SHALL BE
 SUBJECT TO THE DIRECTION OR APPROVAL OF THE CITY'S
 CONSTRUCTION SERVICES DEPARTMENT. BUILDINGS WHICH
 CONTAIN MORE THAN ONE COMMERCIAL, INDUSTRIAL, OR
 INSTITUTIONAL ADDRESS SHALL POST A SEPARATE ADDRESS
 MEETING THE REQUIREMENTS OF THIS SECTION AT THE
 EXTERIOR ENTRANCE TO EACH INDIVIDUAL ADDRESS OR COMMON
 EXTERIOR ENTRANCE TO SEVERAL ADDRESSES THEREIN, AND THE
 UNIT NUMBER SHALL ALSO BE POSTED ON THE EXTERIOR DOOR
 OF EACH UNIT SERVED BY SUCH A COMMON EXTERIOR ENTRANCE.
  
 2) LS01- LIFE SAFETY PLAN:
  
 2A) IT IS A BIT CONFUSING, THIS SHEET IS LISTED AS THE
 LIFE SAFETY SHEET, 3 SEPARATE TENANT BAYS ARE SHOWN BUT
 ONLY THE B-3 BAY IS ACTUALLY A LIFE SAFETY PLAN. THE
 UPPER LEFT HAND CORNER OF THE SHEET THE HEADING IS FOR
 TENANT B01. IS THIS SHEET FOR ALL 3 TENANTS OR FOR
 TENANT B01? 107.2.1.2 ADDITIONAL INFORMATION IS
 REQUIRED.
  
 2B) THE LIFE SAFETY PLAN STATES THE OCCUPANCY TYPE IS
 MERCANTILE. FURTHER DOWN THE OCCUPANCY TYPE IS DECLARED
 FOR ALL 3 TENANT SPACES, B1- N/A, BOTH B03 AND B04 AS
 MERCANTILE. PLEASE SEE SECTION 304.1 IN THE 2020
 FBC-BUILDING CODE. BOTH BARBER AND BEAUTY SHOPS ARE
 CLASSIFIED AS BUSINESS OCCUPANCIES. PLEASE UPDATE THE
 PLAN. SINCE TENANT SPACE B-01IS UNDECLARED OCCUPANCY /
 SHELL SPACE WOULDN?T B04 NOW DO THE SAME SINCE THERE IS
 NO TENANT FIT UP AS PART OF THIS PERMIT AND NOT A
 DECLARED OCCUPANCY TYPE?
  
 2C) THE DEMOLITION PLAN DOES NOT DECLARE WHAT TYPE OF
 OCCUPANCY B3 WAS? MOST LIKELY IT WAS A MERCANTILE
 OCCUPANCY AND IF SO THEN THE BEAUTY SHOP MOVING INTO
 THE NEW TENANT SPACE B03 WOULD BE A CHANGE IN OCCUPANCY
 AND THE PLANS WOULD NEED TO SHOW COMPLIANCE WITH THE
 2020 FBC-EXISTING BUILDING CODE( NOT LISTED UNDER
 APPLICABLE CODES) AND SECTION 1001.2.2.1 BUILDINGS
 UNDERGOING A PARTIAL CHANGE OF OCCUPANCY.
  
 2D) PLEASE ALSO NOTE A CHANGE IN THE 2020 FBC-BUILDING
 FOR BUSINESS OCCUPANCIES SEE TABLE 1004.5. THE
 OCCUPANCY LOAD FACTOR IS NO LONGER 100 SQ. FT. BUT NOW
 150 SQ. FT. OCCUPANT LOAD FACTOR.
  
 3) SHEET A631 ENLARGED RESTROOM:
  
 3A) THE WATER CLOSET GRAB BARS ARE DIMENSIONED FROM
 FLOOR TO THE CENTERLINE OF THE BAR. 2020
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
  
 3B) THE TOILET PAPER DISPENSER IS NOT DIMENSIONED FROM
 THE WATER CLOSET. TOILET PAPER DISPENSERS. 604.7. THE
 TOILET PAPER DISPENSER SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES MINIMUM TO 9 INCHES MAXIMUM IN FRONT
 OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER.
  
 3C) THE MIRROR IS DIMENSIONED TO THE BOTTOM OF THE
 MIRROR FRAME NOT THE REFLECTIVE SURFACE. 603.3 MIRRORS.
 2020 FBC-ACCESSIBILITY CODE. MIRRORS LOCATED ABOVE
 LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE
 BOTTOM EDGE OF THE REFLECTING SURFACE 40 INCHES MAXIMUM
 ABOVE THE FINISH FLOOR OR GROUND.
  
 3D) TOILET ROOM DOORS. 2017 FBC-ACCESSIBILITY CODE
 FIGURE 604.8.1.6 SHOWS AN OUTSWING DOOR. DOORS SHALL BE
 PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE.
 PLEASE SEE EXCEPTION 2. WHERE TOILET ROOMS ARE FOR
 INDIVIDUAL USE AND A CLEAR FLOORS SPACE COMPLYING WITH
 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE
 DOOR SWING. WHAT IS MISSING IS THE REQUIRED 30X48 INCH
 CLEAR FLOOR SPACE BEYOND THE ARC OF THE DOOR. USUALLY
 AT A 45% ANGLE TO THE DOOR ENTRANCE.
  
 3E) SHEET A101 DOES NOT INDICATE A HIGH LOW WATER
 FOUNTAIN. DRINKING FOUNTAINS. 2020 FBC-ACCESSIBILITY
 CODE. 211.2 MINIMUM NUMBER. NO FEWER THAN TWO DRINKING
 FOUNTAINS SHALL BE PROVIDED. ONE DRINKING FOUNTAIN
 SHALL COMPLY WITH 602.1 THROUGH 602.6 AND ONE DRINKING
 FOUNTAIN SHALL COMPLY WITH 602.7.
  
 3F) PROTRUDING OBJECTS 307.2 PROTRUSION LIMITS 307.2.
 OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES AND NOT
 MORE THAN 80 INCHES ABOVE THE FLOOR SHALL NOT PROTRUDE
 MORE THAN 4 INCHES HORIZONTALLY INTO THE CIRCULATION
 PATH.
  
 3G) 602.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE
 COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH,
 AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE
 PROVIDED.
  
 3H) SPOUT OUTLETS/ DRINKING FOUNTAINS. 2017 ACCESS.
 CODE. SPOUT OUTLETS SHALL COMPLY WITH:
 602.4 SPOUT HEIGHT. 36 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND FOR WHEELCHAIR BOUND INDIVIDUALS.
 602.7 SPOUT HEIGHT FOR THE STANDING PERSONS SHALL BE
 BETWEEN 38 TO 43 INCHES ABOVE FINISH FLOOR.
  
 4) SHEET A320 DETAILS 1 & 2 SHOW AWNING/ CANOPIES.
 AWNING AND CANOPY INSTALLATIONS REQUIRE A SEPARATE
 PERMIT, REVIEW AND ASSOCIATED FEES, 105.1 PERMITS.
  
 5) SUBMIT PRODUCT APPROVALS FOR, COMPONENTS AND
 CLADDING. THE DEMO SHEET NOTES 11 & 12 BOTH INDICATE
 THE REMOVAL OF STOREFRONT WINDOW AND DOOR SYSTEMS.
 SHEET A-550 SHOW ELEVATIONS OF THE NEW STOREFRONT
 SYSTEMS. SHEET S-200 SHOWS THE NEW STRUCTURAL STEEL FOR
 THE STOREFRONT SYSTEM AS WELL AS THE NEW STRUCTURAL
 STUDS FOR THE BLOCKED IN AREA OF STOREFRONT.
 COMPONENTS & CLADDING. 2020 FBC-B 1609.1.2 PROTECTION
 OF OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE
 CODE 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS, MULLIONS.
 (B) WINDOWS & MULLIONS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, EFIS
 SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS FOR
 RTU UNITS, LIGHTWEIGHT CONCRETE INSULATION, ROOF TOP
 VENTILATORS
  
 6) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE
 PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF
 RECORD AND BEFORE SUBMISSION TO THE BUILDING
 DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING,
 MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED
 INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE
 PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B 1405.13.1
 INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN
 ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS.
 FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH
 INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM
 LOADS AND SPACING USED IN THE TESTS.
  
 7) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP
 DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD
 PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 8) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF
 THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 9) WELDED OR BOLTED CONNECTIONS. THIS BUILDING CONTAINS
 EITHER BOLTED AND OR WELDED CONNECTIONS. THE CONTRACTOR
 IS REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS &
 WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN
 ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF
 INSPECTION FOR FIELD WIELDING, ON THE JOB-SITE
 WIELDING. THIRD PARTY CERTIFICATION WILL BE REQUIRED.
 THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO
 COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS
 SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING
 INSPECTION.
 2020 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED,
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN
 CONRAD AT 561-805-6666.
  
 10) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-07-19 Cont ID  
Sent By jleahy Date 2021-07-19 Time 17:59 Rev Time 0.00
Received By jleahy Date 2021-07-19 Time 17:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-05-10 Cont ID  
Sent By jleahy Date 2021-05-10 Time 15:16 Rev Time 0.00
Received By jleahy Date 2021-05-10 Time 14:37 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-06-22 Cont ID  
Sent By   Date 2021-06-22 Time   Rev Time 0.00
Received By bdolan Date 2021-06-22 Time 14:45 Sent To  
Notes
2021-06-22 14:52:21REVISION PASSED BY FIRE.
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date   Cont ID  
Sent By bdolan Date 2021-04-21 Time   Rev Time 0.00
Received By bdolan Date 2021-04-15 Time 10:58 Sent To  
Notes
2021-04-21 12:40:32THIS PLAN WAS REVIEWED AND WITH PROVISO BY LIEUTENANT
 BRIAN DOLAN, BUREAU OF FIRE PREVENTION, WEST PALM BEACH
 FIRE RESCUE WITH THE FOLLOWING COMMENTS.
  
 THIS PLAN IS APPROVED WITH THE PROVISO THAT THE SCOPE
 OF WORK DOES NOT INCLUDE ANY PENETRATIONS OF THE RATED
 FIRE WALL ADJACENT TO B01 (SEPARATION FROM WHOLE FOODS)
  
 BASED ON PRIOR PERMITTING AND CONSTRUCTION AGREEMENTS,
 THE WHOLE FOODS OCCUPANCY MUST MAINTAIN SEPARATION FROM
 THE ADJOINING OCCUPANCIES WITH NO LESS THAN THE CURRENT
 3 HOUR FIRE RATED SEPARATION. THE WHOLE FOODS EXPANSION
 AS NOTED IN THIS PLAN SET DOES NOT ADDRESS THIS
 SEPARATION. ANY FUTURE WORK MUST ALSO EITHER MAINTAIN
 SEPARATION OR ADDRESS SPECIFICALLY IN SEPERATE PERMIT.
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-07-23 Cont ID  
Sent By lmarchan Date 2021-07-23 Time 10:51 Rev Time 0.00
Received By lmarchan Date 2021-07-22 Time 15:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-07-19 Cont ID  
Sent By jleahy Date 2021-07-19 Time 18:00 Rev Time 0.00
Received By jleahy Date 2021-07-12 Time 10:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-06-23 Cont ID  
Sent By pvalenti Date 2021-06-23 Time 18:39 Rev Time 0.00
Received By pvalenti Date 2021-06-02 Time 13:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-19 Cont ID  
Sent By lmarchan Date 2021-05-19 Time 14:18 Rev Time 0.00
Received By lmarchan Date 2021-04-12 Time 10:55 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2021-05-11 Cont ID  
Sent By jwitmer Date 2021-05-11 Time 08:57 Rev Time 0.00
Received By jwitmer Date 2021-05-11 Time 08:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-05-10 Cont ID  
Sent By medwards Date 2021-05-10 Time 13:21 Rev Time 0.00
Received By medwards Date 2021-05-10 Time 13:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2021-07-23 Cont ID  
Sent By tklarge Date 2021-07-23 Time 08:04 Rev Time 0.00
Received By tklarge Date 2021-07-23 Time 08:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2021-07-19 Cont ID  
Sent By tklarge Date 2021-07-19 Time 06:24 Rev Time 0.00
Received By tklarge Date 2021-07-19 Time 05:18 Sent To  
Notes
2021-07-19 06:16:411) THE WATER SUPPLY TO THE PEDICURE CHAIRS SHALL BE
 TEMPERED WATER PER FBC-PLUMBING SEC.412.5. THE TEMPERED
 WATER VALVE SHALL COMPLY WITH ASSE 1070. 3RD REQUEST.
 2) THE SANITARY RISER HAS A FLAT, DRY VENT ON EACH
 HORIZONTAL DRAIN FOR THE FLOOR DRAINS. EVERY DRY VENT
 CONNECTING TO A HORIZONTAL DRAIN SHALL CONNECT ABOVE
 THE CENTERLINE OF THE HORIZONTAL DRAIN PIPE PER
 FBC-PLUMBING SEC.905.3.2ND REQUEST. THE DRAWING IS
 NON-COMPLIANT.
 3) THE SUBMITTED FLOOR/WALL DRAIN SPECIFICATIONS ARE
 ILLEGIBLE. SUBMIT CLEAR AND LEGIBLE SPECIFICATIONS FOR
 REVIEW. 2ND REQUEST.
 4) EACH PEDICURE CHAIR SHALL BE EQUIPPED WITH A
 BACKFLOW PREVENTION DEVICE PER FBC-PLUMBING SEC.608.2.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-06-23 Cont ID  
Sent By tklarge Date 2021-06-23 Time 15:13 Rev Time 0.00
Received By tklarge Date 2021-06-22 Time 06:42 Sent To  
Notes
2021-06-23 14:45:561) SHT. LS 101 - SHOW THE PREVIOUS OCCUPANCY OF SPACE
 B04 ON THE PLAN. WPB AMEND. TO FBC SEC. 107.2.1.
 2) THE BREAKROOM SINK ( NOT THE MOP SINK) IN THE
 EMPLOYEE BREAK AREA IN TENANT SPACE B 03 SHALL COMPLY
 WITH FBC-ACCESS. SECS. 606..2, 606.3, 606.4 &606.5.
 COMPLIANCE HAS NOT BEEN CLEARLY SHOWN ON THE PLANS.2ND
 REQUEST.
 3) THE SINK IN THE FACIAL/WAX ROOM IN TENANT SPACE B 03
 SHALL COMPLY WITH FBC-ACCESS. SECS.606.2,,606.3,606.4 &
 606.5. COMPLIANCE HAS NOT BEEN CLEARLY SHOWN ON THE
 PLANS. 2ND REQUEST.
 4) THE WALL FINISH AROUND THE MOP SINK SHALL COMPLY
 WITH FBC SEC.1210.2.2. THE PLANS DO NOT CLEARLY SHOW
 COMPLIANCE. 2ND REQUEST.
 5) THE SUBMITTED FLOOR/WALL DRAIN SPECIFICATIONS ARE
 COMPLETELY ILLEGIBLE. SUBMIT CLEAR AND LEGIBLE
 SPECIFICATIONS FOR REVIEW. WPB AMEND. TO FBC SEC.
 107.2.1.
 6) THE CHAIR SPECIFICATION SHEET IS ILLEGIBLE.SUBMIT
 CLEAR AND LEGIBLE SPECIFICATIONS FOR REVIEW. WPB AMEND.
 TO FBC SEC. 107.2.1.
 7) EACH PEDICURE CHAIR SHALL BE EQUIPPED WITH A
 BACKFLOW PREVENTION DEVICE. FBC-PLUMBING SEC.608.2.
 8) A FULL OPEN VALVE IS REQUIRED ON THE COLD WATER
 SUPPLY PIPE TO THE WATER HEATER. FBC-PLUMBING SEC.606.1
 (8).
 9) THE SANITARY RISER HAS A FLAT, DRY VENT ON EACH
 BUILDING DRAIN FOR THE TUBS. VENTS CONNECTED TO THE
 DRAINAGE SYSTEM SHALL COMPLY WITH FBC-PLUMBING
 SEC.905.3.
 10) THE DESIGN OF THE TUB DRAIN SANITARY SYSTEM DOES
 NOT COMPLY WITH THE FBC-PLUMBING CODE. THE DRAINAGE
 SYSTEM FOR THE TUBS SHALL BE DESIGNED AS A CIRCUIT VENT
 SYSTEM IN ACCORDANCE WITH FBC-PLUMBING
 SECS.914.1,914.1.1, 914.2, 914.3.1.
 11) THE WATER SUPPPLY TO THE PEDICURE CHAIRS SHALL BE
 TEMPERED WATER PER FBC-PLUMBING SEC. 412.5. THE
 TEMPERED WATER VALVE SHALL COMPLY WITH ASSE 1070. 2ND
 REQUEST.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-04-30 Cont ID  
Sent By tklarge Date 2021-04-30 Time 06:52 Rev Time 0.00
Received By tklarge Date 2021-04-27 Time 13:44 Sent To  
Notes
2021-04-29 06:46:311) SHT. LS 01 NOTES THE OCCUPANCY OF SPACE B03 AS AN
 "M" OCCUPANCY (MERCANTILE). THIS SPACE IS GOING TO BE A
 BEAUTY SHOP/NAIL SALON WHICH IS CLASSIFIED AS A GROUP
 "B" OCCUPANCY ACCORDING TO FBC-BUILDING SEC. 304.1. HOW
 CAN THIS BE CLASSIFIED AS AN "M" OCCUPANCY? IS THIS
 BUILDOUT A CHANGE OF OCCUPANCY/CHANGE OF USE? INDICATE
 ON THE PLAN. WPB AMEND. TO FBC SEC. 107.2.1.
 2) INDICATE THE PREVIOUS OCCUPANCY OF ALL THE SPACES ON
 THIS PLAN AND INDICATE ON THE PLANS IF ANY OF THIS NEW
 WORK WILL BE A CHANGE OF OCUPANCY/CHANGE OF USE. WPB
 AMEND. TO FBC SEC. 107.2.1.
 3) THE BREAKROOM SINK (NOT THE MOP SINK) IN THE
 EMPLOYEE BREAK AREA IN TENANT SPACE B03 SHALL COMPLY
 WITH THE FBC-ACCESS. SECS. 606.2, 606.3, 606.4, 606.5.
 4) THE SINK IN ONE OF THE WAX ROOMS IN TENANT SPACE B03
 SHALL COMPLY WITH FBC-ACCESS. SECS. 606.2, 606.3,
 606.4, 606.5.
 5) THE WALL FINISH AROUND THE MOP SINK SHALL OMPLY WITH
 FBC-BUILDING SEC.1210.2.2.
 6) SHT. A631- DETAIL #1 - THE DOOR CANNOT SWING INTO
 THE CLEAR FLOOR SPACE FOR THE LAVATORY OR THE WATER
 CLOSET PER FBC SEC. 603.2.3 UNLESS A 30 INCH WIDE
 MINIMUM BY 48 INCH LONG MINIMUM CLEAR FLOOR SPACE IS
 PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOOR
 SWING. SHOW THE REQUIRED CCLEAR FLOOR SPACE OR REVERSE
 THE DOOR SWING.
 7) SHT. A631 - THE HEIGHT OF THE GRAB BARS ARE SHOWN
 MEASURED TO THE CENTERLINE OF THE GRAB BARS. GRAB BARS
 SHALL BE MEASURED TO THE TOP OF THE GRIPPING SURFACE
 PER FBC-ACCESS. SEC. 609.4.
 8) SHT. A631 - TOILET ACCESSORY MOUNTING HEIGHTS - THE
 OUTLET OF THE SOAP DISPENSER SHALL BE LOCATED A MAXIMUM
 OF 48 INCHES ABOVE THE FINISH FLOOR. FBC-ACCESS.
 SECS.308.2, 308.3.
 9) SHT. A631 - ELEVATION #2 - THE LAVATORY SHALL BE
 LOCATED A MINIMUM OF 15 INCHES FROM THE WALL TO THE
 CENTERLINE OF THE LAVATORY PER FBC-PLUMBING
 SEC.405.3.1.THE PLANS SHOW THE LAVATORY AT 14 INCHES.
 11) SINCE THIS IS A BUSINESS OCUPANCY A MINIMUM OF 2
 DRINKING FOUNTAINS ARE REQUIRED PER FBC- PLUMBING TABLE
 403.1 AND SEC.410.3.
 12) SHT. P001 - NOTE #13 REFERS TO FIRE RATED FOAM,
 CAULKING OR PUTTY FOR SEALING PENETRATIONS THROUGH
 RATED WALLS. SUBMIT MANUFACTURER'S SPECIFICATIONS FOR
 THESE PRODUCTS TO ONIRM COMPATABILITY ITH THE
 PENETRATING ITEM. WPB AMEND. TO FBC SEC. 107.2.1.
 13) SHT. P001 - WATER PIPE SIZING TABLE NOTE REFERS TO
 CHAPTER 4 OF MIAMI-DADE ORDINANCE 08-14. THIS NOTE IS
 NOT APPLICABLE. REMOVE THIS NOTE FROM THE PLANS.
 14) SHT. P001 - WATER PIPE SIZING TABLE NOTE #2 REFERS
 TO FBC SECS. 2318.1.15 AND 2517.5.1.1.REMOVE THIS NOTE
 FROM THE PLANS AS BOTH SECTIONS ARE SHOWN AS "RESERVED"
 IN THE CODE AND NOT APPLICAABLE.
 15) SHT. P001 - SHOW THE PAN DRAIN FOR THE WATER HEATER
 AND THE TERMINATION POINT OF THE PAN DRAIN ON THE WATER
 HEATER DETAIL.SHOW THE SIZE OF THE PAN DRAIN.
 16) PROVIDE DETAILS OF THE SHELF CONSTRUCTION FOR THE
 WATER HEATER. THE WATER HEATER WILL WEIGH MORE THAN 665
 POUNDS WHEN FILLED WITH WATER. THERE IS NO INFORMATION
 ON THE PLANS AS TO HOW THIS SHELF IS TO BE CONSTRUCTED
 OR ANY INFORMATION ON LOAD BEARING STRENGTH,
 CONNECTIONS, ETC. WPB AMEND. TO FBC SEC. 107.2.1.
 17) SHT. P001 SHOWS A PRESSURE RELIEF VALVE ON THE COLD
 WATER INLET TO THE WATER HEATER. CLARIFY.
 18) THE ENTIRE HOT WATER PIPING SYSTEM SHALL BE
 INSULATED WITH INSULATION WITH A WALL THICKNESS IN
 ACCORDANCE WITH FBC-ENERGY SEC.C404.4 AND TABLE
 C403..2.10. SHOW COMPLIANCE ON THE PLANS.
 19) A BACKFLOW PREVENTER WILL BE REQUIRED ON THE WATER
 LINE TO THE TOWEL STEAMER.FBC-PLUMBING SEC.608.3.
 20) HEATED WATER SUPPLY PIPING SHALL BE IN ACORDANCE
 WITH SECTION C404.5.1 OR C404.5.2. SHOW COMPLIANCE ON
 THE WATER RISER.
 21) PROVISIONS SHALL BE MADE FOR THERMAL EXPANSION OF
 THE WATER SSUPPLY SYSTEM. IF THE PRESSURE RELIEF VALVE
 ON THE COLD WATER SYTEM IS TO MEET THIS PROVISION,
 LABEL THE VALVE AS A THERMAL EXXPAANSION VALVE AND
 SHOWW THE TERMINATION POINT OF THE DISCHARGE LINE OF
 THE VALVE.
 22) THE WATER CONNECTION TOWEL STEAMER IS NOT SHOWN ON
 THE WATER RISER. CLARIFY.
 23) SUBMIT A CONCRETE SLAB DETAIL SHOWING HOW THE SLAB
 CUTOUT WILL BE REPAIRED TO MAINTAIN THE STRUCTURAL
 INTEGRITY. INDICATE THE SIZE OF REINFORCING BARS TO BE
 USED, THE EMBEDMENT DEPTH THAT THE REBAR WILL BE
 DOWELED INTO THE EXISTING SLAB, HOW THE DOWELS WILL BE
 SET IN THE EXISTING SLAB, AND THE SPACING ON CENTER OF
 THE DOWELS. SHOW THE THICKNESS OF THE EXISTING SLAB &
 THE REPAIR. A VAPOR BARRIER AND TERMITE POISONING IS
 REQUIRED.WPB AMEND. TO 2010 FBC SEC.107.2.1.
 24) THE WATER SUPPLY TO THE PEDICURE CHAIRS SHALL BE
 TEMPERED WATER PER FBC-PLUMBING SEC. 412.5. THE
 TEMPERED WATER VALVE SHALL COMPLY WITH ASSE 1070.
 25) SHT. LS 01- SPACE B03 IS LABELED AS B03 BUT THE
 SAME SPACE IS LABELED AS B01 ON SHT.P101. CLARIFY.
 26) SHT. A101 - IDENTIFY EACH BAY ON THE FLOOR PLAN.
 WPB AMEND. TO FBC SEC. 107.2.1.
 27) SUBMIT MANUFACTURER'S SPECIFICATIONS/INSTALLATION
 MANUAL FOR THE PEDICURE CHAIRS.WPB AMEND. TO FBC SEC.
 107.2.1.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-07-23 Cont ID  
Sent By tklarge Date 2021-07-23 Time 08:07 Rev Time 0.00
Received By tklarge Date 2021-07-23 Time 08:04 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-07-19 Cont ID  
Sent By jleahy Date 2021-07-19 Time 18:00 Rev Time 0.00
Received By jleahy Date 2021-07-19 Time 18:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-06-23 Cont ID  
Sent By pvalenti Date 2021-06-23 Time 18:33 Rev Time 0.00
Received By pvalenti Date 2021-06-23 Time 13:19 Sent To  
Notes
2021-06-23 18:38:47****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 SIGNATURE REVIEW DENIED:
  
 THE SUBMITTED SHOP DRAWING ENGINEER'S SIGNATURE/SEALS
 ARE NOT 3RD PARTY VERIFIED AND THESE DRAWINGS ARE NOT
 REVIEW STAMP APPROVED BY THE DESIGNER OF RECORD.
  
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD/EMAIL A DIGITALLY SIGNED (THIRD PARTY VERIFIED)
 PLAN OR YOU CAN MAIL/HAND DELIVER AN ORIGINAL
 SIGNED/SEALED PAPER ORIGINAL TO:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 401 CLEMATIS STREET
 P.O. BOX 3147
 WEST PALM BEACH, FL 33402
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES/BUILDING DEPT.
 561 805 6673
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-05-10 Cont ID  
Sent By medwards Date 2021-05-10 Time 13:38 Rev Time 0.00
Received By medwards Date 2021-05-10 Time 13:38 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2021-07-19 Cont ID  
Sent By eschneid Date 2021-07-19 Time 09:03 Rev Time 0.25
Received By eschneid Date 2021-07-19 Time 08:51 Sent To  
Notes
2021-07-19 09:05:43PASSED W/PROVISO
  
 PRIOR TO CO OF THE THIS PERMIT FOR THE AVALON SPACE, A
 MINOR PLANNED DEVELOPMENT AMENDMENT TO UPDATE THE URBAN
 DESIGN STUDIO PLANS FOR THE PALM BEACH OUTLETS MUST BE
 SUBMITTED TO AND APPROVED BY THE PLANNING DIVISION
 SHOWING THE REMOVAL OF THE FOUNDATION PLANTING AND ITS
 REPLACEMENT IN FRONT OF BAY B05 THAT IS INCLUDED WITH
 PERMIT NO. 21051408 (MARSHALL'S). THE BICYCLE RACK
 BEING REMOVED MUST BE ACCOUNTED FOR ON THE UPDATED
 OVERALL SITE PLAN DATA TABLE (MUST BE RELOCATED IF
 REMOVAL WOULD MAKE SITE DEFICIENT IN BICYCLE PARKING).

Review Stop Z ZONING
Rev No 2 Status F Date 2021-06-21 Cont ID  
Sent By eschneid Date 2021-06-21 Time 16:44 Rev Time 0.50
Received By eschneid Date 2021-06-21 Time 15:18 Sent To  
Notes
2021-06-21 16:45:02FAILED
  
 1) THE SITE LINE DRAWING THAT WAS PROVIDED SHOWS THAT
 THE NEW RTU IS VISIBLE. THE USE OF THE SKY VINYL WAS
 ONLY AUTHORIZED FOR THE ORIGINAL ROOFTOP UNITS WHEN THE
 SITE LINES WERE PROVIDED THAT DID NOT ACCURATELY SHOW
 THAT THE EQUIPMENT WOULD BE VISIBLE DURING THE
 PERMITTING PROCESS. STAFF WILL NOT APPROVE A ROOFTOP
 PLAN THAT CLEARLY SHOWS THE EQUIPMENT VISIBLE, WHICH
 DOES NOT COMPLY WITH THE PALM BEACH OUTLETS DESIGN
 GUIDELINES. AN ALTERNATE (LOWER PROFILE) RTU MUST BE
 USED.
  
 2) PRIOR TO CO OF THE THIS PERMIT FOR THE AVALON SPACE,
 A MINOR PLANNED DEVELOPMENT AMENDMENT TO UPDATE THE
 URBAN DESIGN STUDIO PLANS MUST BE SUBMITTED TO AND
 APPROVED BY THE PLANNING DIVISION SHOWING THE REMOVAL
 OF THE FOUNDATION PLANTING AND ITS REPLACEMENT IN FRONT
 OF BAY B05 THAT IS INCLUDED WITH PERMIT NO. 21051408
 (MARSHALL'S). THIS BICYCLE RACK BEING REMOVED MUST BE
 ACCOUNTED FOR ON THE UPDATED OVERALL SITE PLAN DATA
 TABLE.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2021-05-19 Cont ID  
Sent By eschneid Date 2021-05-19 Time 14:10 Rev Time 0.50
Received By eschneid Date 2021-05-19 Time 14:10 Sent To  
Notes
2021-05-19 14:13:05FAILED
  
 1) THE PLANS SHOW THE REMOVAL OF FOUNDATION PLANTING AS
 PART OF THE PROPOSED RENOVATIONS. THE REMOVAL OF THE
 LANDSCAPE REQUIRES THE APPROVAL OF A MINOR PLANNED
 DEVELOPMENT AMENDMENT PRIOR TO ZONING APPROVAL OF THIS
 PERMIT. NOTE: IT APPEARS THAT THE AMOUNT OF FOUNDATION
 PLANTING THAT IS PROPOSED TO BE REMOVED WILL RESULT IN
 A DEFICIENCY OF THE REQUIRED FOUNDATION PLANTING, WHICH
 DOES NOT PERMIT THIS PERMIT TO BE APPROVED.
  
 2) PROVIDE THE SITE LINE DRAWING FOR THE FULL HEIGHT,
 INCLUDING CURB, FOR THE NEW ROOFTOP MECHANICAL
 EQUIPMENT (AHU, FAN, ETC.) TO VERIFY THAT IT IS NOT
 VISIBLE TO THE PUBLIC FROM THE EAST SIDE OF THE
 BUILDING.
  
 3) THE LABELS ON SHEET A300 ARE UNREADABLE. PROVIDE AN
 SHEET WITH LEGIBLE LABELS.
  
 4) THE PALM BEACH OUTLETS DESIGN GUIDELINES REQUIRE
 THAT CANOPIES PROJECT A MINIMUM OF THREE FEET SIX
 INCHES FROM THE BUILDING. PROVIDE THE DIMENSION OF THE
 CANOPY ON THE PLANS (SHEET A320 MAY BE THE BEST ONE).
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  
  