| Plan Review Stops For Permit 21040660 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-04-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-04-16 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-04-16 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2022-07-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-07 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-06 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2022-07-07 08:10:37 | LETTER FROM CONTRACTOR TO RB ON 6/30/2022, PLEASE | | | REVOKE PERMIT. OWNERS DO NOT WANT TO PROCEED. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2022-04-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-22 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-04-19 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2022-04-22 14:34:04 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 4TH REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | 1. CORRECTED | | | | | | 2. CORRECTED | | | | | | 3. CORRECTED | | | | | | 4. PROVIDE THE ICC-ES REPORT FOR THE ICYNENE SPRAY | | | APPLIED INSULATION. DESIGNER SHALL IDENTIFY SYSTEM TO | | | BE INSTALLED. (NOT SUBMITTED FOR REVIEW) | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | NEW COMMENTS: | | | | | | PLACE THE FOLLOWING INFORMATION ON GARAGE FLOOR PLAN, | | | PG A1.1 NEXT TO EACH FV: | | | | | | FV MODEL 1540-520 | | | NET 122.1 SQ/IN = 200 SF COVERAGE | | | EACH GARAGE IS 498 SF | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-01-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-07 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-06 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2022-01-07 14:27:23 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. DESIGN CRITERIA PER ARCHITECT OF RECORD (AOR) FOR | | | PROPOSED STRUCTURE IS RISK FACTOR (1), EXPOSURE "D", | | | ENCLOSED BUILDING. | | | CORRECT BUILDING DATA ON COVER PAGE C-1 FROM EXPOSURE | | | "C" TO EXPOSURE "D". | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. REFERENCE SITE PLAN SP1 FOR THE FOLLOWING: NOTE FOR | | | EQUIPMENT ELEVATION USES NGVD DATUM. | | | ALL DATUM SHALL BE IN NAVD 88. PLEASE CORRECT. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. PROVIDE INSTALLATION INSTRUCTIONS FOR SMART VENT | | | PRODUCT APPROVAL FL5822-R8. ONLY THE COVER SHEET WAS | | | SUBMITTED FOR REVIEW. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 4. PROVIDE THE ICC-ES REPORT FOR THE ICYNENE SPRAY | | | APPLIED INSULATION. DESIGNER SHALL IDENTIFY SYSTEM TO | | | BE INSTALLED. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-23 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-07 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2021-09-07 13:36:35 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. REF. COVER PAGE FOR THE FOLLOWING COMMENT: | | | GOVERNING CODES ARE THE FBC 2020 7TH ED WITH 2017 NEC. | | | (NOT ADDRESSED) | | | | | | 2. PROVIDE A BOUNDARY LINE SURVEY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | CORRECTED | | | | | | 3. PROVIDE FINISHED FLOOR ELEVATION OF MAIN RESIDENCE | | | AND GARAGE ON FLOOR PLAN AND/OR FOUNDATION PLAN. | | | R322.2.1ELEVATION REQUIREMENTS. | | | CORRECTED | | | | | | 4. N/A | | | | | | | | | 5. SITE DRAINAGE PLAN-SEE PLAN PAGES C-1 AND C-2. | | | CORRECTED | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | (RETAINING WALL UNDER PERMIT 21030567) | | | | | | 6. PROVIDE A SOILS REPORT. | | | FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL | | | BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. | | | CORRECTED | | | | | | 7. REF. THE WINDOW AND DOOR SCHEDULE FOR THE FOLLOWING | | | COMMENT: CORRECTED | | | 7A) PROVIDE DESIGN PRESSURES FOR EACH OPENING. | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | (NOT ADDRESSED) | | | | | | 8. PRODUCT APPROVALS: | | | 8A) FL15438-R2 HAS EXPIRED. PROVIDE PRODUCT APPROVAL | | | APPROVED UNDER THE 2020 FBC 7TH ED. | | | (NOT ADDRESSED) | | | 8B) DESIGNER SHALL SELECT MODEL OF DOOR TO BE INSTALLED | | | FROM FL15446-R2. | | | (NOT ADDRESSED) | | | 8C) PROVIDE INSTALLATION INSTRUCTIONS FOR FL15446-1. | | | CORRECTED | | | 8D) WINDOW SCHEDULE INDICATES SINGLE HUNG WINOWS SHALL | | | BE INSTALLED. PROVIDE PRODUCT APPROVALS FOR SH WINDOWS. | | | | | | 8E) SHOP DRAWINGS FOR 6' AND 10" HOLLOW CORE FLOORING | | | IS DEFERRED. PROVIDE TO CITY INSPECTOR. | | | | | | NEW COMMENTS: | | | | | | 9. PROVIDE PRODUCT APPROVALS FOR SMART VENTS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 10. PROVIDE ICC-ES REPORT FOR ICYNENE SPRAY FOQAM | | | INSULATION. A COPY OF THIS SHALL BE IN THE FIELD FOR | | | INSPECTION. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-28 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-25 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2021-06-28 12:31:17 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. REF. COVER PAGE FOR THE FOLLOWING COMMENT: | | | GOVERNING CODES ARE THE FBC 2020 7TH ED WITH 2017 NEC. | | | | | | 2. PROVIDE A BOUNDARY LINE SURVEY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. PROVIDE FINISHED FLOOR ELEVATION OF MAIN RESIDENCE | | | AND GARAGE ON FLOOR PLAN AND/OR FOUNDATION PLAN. | | | R322.2.1ELEVATION REQUIREMENTS. | | | | | | 4. IDENTIFY LOCATION OF REQUIRED FLOOD OPENINGS ON | | | GARAGE FOUNDATION PLANS. SEE COMMENTS UNDER NFIP | | | REVIEW. | | | R322.2.2ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION. | | | | | | 5. PROVIDE A SITE DRAINAGE PLAN. DRAINAGE PERMIT | | | 21030567 HAS NOT BEEN REVIEWED OR APPROVED. NO FEES | | | PAID TO DATE. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | | | | 6. PROVIDE A SOILS REPORT. | | | FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL | | | BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. | | | | | | 7. REF. THE WINDOW AND DOOR SCHEDULE FOR THE FOLLOWING | | | COMMENT: | | | 7A) PROVIDE DESIGN PRESSURES FOR EACH OPENING. | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | | | | 8. PRODUCT APPROVALS: | | | 8A) FL15438-R2 HAS EXPIRED. PROVIDE PRODUCT APPROVAL | | | APPROVED UNDER THE 2020 FBC 7TH ED. | | | 8B) DESIGNER SHALL SELECT MODEL OF DOOR TO BE INSTALLED | | | FROM FL15446-R2. | | | 8C) PROVIDE INSTALLATION INSTRUCTIONS FOR FL15446-1. | | | 8D) WINDOW SCHEDULE INDICATES SINGLE HUNG WINOWS SHALL | | | BE INSTALLED. PROVIDE PRODUCT APPROVALS FOR SH WINDOWS. | | | 8E) PROVIDE PRODUCT APPROVALS FOR 6" AND 10" HOLLOW | | | CORE PLANKS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-06-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-01 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-01 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-06-04 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-06-04 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-06-04 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2021-06-04 11:24:53 | A GRILL IS SHOWN IN A COVERED PATIO AND IF NATURAL GAS | | | OR A LP TANK IS CONNECTED IT WILL REQUIRE THE FOLLOWING | | | BELOW; | | | | | | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | A SUB GAS AND OR HOOD PERMIT IS REQUIRED BY A LICENSED | | | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS | | | TO THE FBC SEC. 105.1. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-07-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-07 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-05 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-04-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-22 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-15 |
Time |
13:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-01-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-01-08 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-11-15 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-09-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-09 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-08-05 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-06-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-28 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-20 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-06-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-26 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-26 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2021-06-26 06:57:28 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-08-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-19 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-19 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-02 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-02 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2021-06-02 16:19:18 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21040660 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) A MECHANICAL SUB-PERMIT IS REQUIRED. | | | | | | 2) FS 471.003 (H): THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS ALONG WITH THE MECHANICAL SYSTEM DESIGN | | | MUST BE DESIGNED BY A FLORIDA LICENSED ENGINEER OR THE | | | MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT FOR THE | | | SPECIFIC PROJECT WHICH HE OR SHE INSTALLS. | | | PLEASE, HAVE EITHER A LICENSED ENGINEER, PROVIDE A | | | SIGNED AND SEALED MECHANICAL EQUIPMENT SIZING | | | CALCULATION AND A SIGNED AND SEALED MECHANICAL DRAWING, | | | OR | | | THE MECHANICAL CONTRACTOR INSTALLING THE SYSTEM SHALL | | | PROVIDE THE EQUIPMENT SIZING CALCULATIONS AND A CODE | | | COMPLIANT DESIGN. CONTRACTOR SHALL INCLUDE HIS OR HER | | | PRINTED NAME AND SIGNATURE PER 2017 WPB AMENDMENTS TO | | | THE FLORIDA BUILDING CODE, CHAPTER 1, SECTION 107.2.1. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | | | | THERE IS NO MECHANICAL SUB PERMIT FOR THIS JOB. | | | | | | I WILL REVIEW THE DRAWINGS ONCE THE ENGINEER HAS | | | APPROVED AND DIGITALLY SIGNED THEM. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
6 |
Status |
N |
Date |
2022-07-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-07 |
Time |
08:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-06 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2022-07-07 08:09:55 | LETTER FROM CONTRACTOR TO RB ON 6/30/2022, PLEASE | | | REVOKE PERMIT. OWNERS DO NOT WANT TO PROCEED. CT |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
5 |
Status |
F |
Date |
2022-04-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-22 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-04-19 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2022-04-22 13:40:13 | PLAN REVIEW / NFIP | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 | | | | | | 5TH REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | SEE 4TH REVIEW COMMENTS BELOW: | | | | | | 1) A1. CORRECTED | | | 2) A2. CORRECTED | | | 3) A5. CORRECTED | | | | | | 4) A9. THE LOCATIONS, SIZE AND TYPE OF FLOOD VENTS NEED | | | TO BE SHOWN ON THE FLOOR PLANS. | | | PLACE THE FOLLOWING INFO ON GARAGE FLOOR PLAN, PG A1.1 | | | NEXT TO EACH FV: | | | | | | FV MODEL 1540-520 | | | NET 122.1 SQ/IN = 200 SF COVERAGE | | | EACH GARAGE IS 498 SF | | | | | | 5) A9(C). CORRECTED | | | 6) C2. CORRECTED | | | 7) C2(E) CORRECTED | | | | | | 8) C2(F) & (G) THE LOWEST ADJACENT GRADE APPEARS TO BE | | | 5.92 FT AT THE ATTACHED GARAGE AND THE HIGHEST ADJACENT | | | GRADE APPEARS TO BE 7.5 FT. AT THE FRONT OF THE | | | RESIDENCE. | | | DATA ENTERED FOR LINE C2 (F) IS 5.0 FT AND DATA ENTERED | | | FOR LINE C2 (G) IS 7.0 FT. | | | SEE PLAN PAGE C-1 FOR ELEVATION DATA FOR C2(F) 5.9 2FT | | | & (G) 7.5 FT | | | | | | 9) CORRECTED | | | 10) CORRECTED | | | | | | NEW COMMENTS: | | | | | | 11) INCLUDE THE FOLLOWING INFORMATION IN THE COMMENTS | | | AREA OF SECTION D: | | | | | | FV MODEL 1540-520 | | | NET 122.1 SQ/IN = 200 SF COVERAGE | | | EACH GARAGE IS 498 SF | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
4 |
Status |
F |
Date |
2022-01-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-01-13 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-01-13 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2022-01-13 09:19:45 | NFIP PEER REVIEW STATUS IS DENIED. | | | THE FOLLOWING CORRECTIONS ARE REQUIRED. | | | | | | 1) A1. THE CURRENT OWNERS NAME IS 3010 FLAGLER LLC. | | | 2) A2. THE ZIP CODE IS 33407. | | | 3) A5. THE NEGATIVE SIGN AND W ARE BOTH GIVEN FOR | | | LONGITUDE. SINCE YOU USED THE DIRECTION N FOR THE | | | LATITUDE TO BE CONSISTANT USE W FOR LONGITUDE AND | | | REMOVE THE NEGATIVE SIGN. | | | 4) A9. THE LOCATIONS, SIZE AND TYPE OF FLOOD VENTS NEED | | | TO BE SHOWN ON THE FLOOR PLANS. | | | 5) A9(C). IF YOU ARE USING THE ENGINEERED SMART VENTS | | | WHICH MEASURE 15-3/4" X 7-3/4", THEN EACH OPENING IS | | | 122.1 SQUARE INCHES. THE TOTAL FOR SIX IS 732.6 SQUARE | | | INCHES. FEMA'S ELEVATION CERTIFICATE INSTRUCTIONS | | | ALLOWS THIS WHEN THE NET AREA OF THE FLOOD VENTS CAN | | | NOT BE REASONABLY ESTIMATED. THE TYPE OF VENT AND | | | COVERAGE CAN BE INDICATED IN THE COMMENT SECTION. | | | 6) C2. THE BENCH MARK UTILIZED SHOULD BE THE PID OR | | | OTHER UNIQUE IDENTIFIER ASSIGNED BY THE MAINTAINER OF | | | THE BENCHMARK. THE VERTICAL SHOULD BE NAVD 88. | | | 7) C2(E) THE ELEVATIONS OF THE GENERATOR AND A/C PADS | | | NEED TO BE SHOWN ON THE CONSTRUCTION DRAWINGS. | | | 8) C2(F) & (G) THE LOWEST ADJACENT GRADE APPEARS TO BE | | | 5.92 FT AT THE ATTACHED GARAGE AND THE HIGHEST ADJACENT | | | GRADE APPEARS TO BE 7.5 FT. AT THE FRONT OF THE | | | RESIDENCE. | | | 9) IN SECTION D MARK YES OR NO TO THE QUESTION OF | | | WHETHER OR NOT LAT. AND LONG. WERE PROVIDED BY A | | | LICENSED LAND SURVEYOR. | | | 10) NOTES SHOULD BE ADDED TO THE PLANS FOR THE GARAGE | | | TO SPECIFY THAT ALL MATERIALS INSTALLED BELOW THE | | | DESIGN FLOOD ELEVATION SHALL BE FLOOD DAMAGE RESISTANT | | | AND ALL EQUIPMENT IS TO BE ELEVATED ABOVE THE DFE. |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
3 |
Status |
F |
Date |
2022-01-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-11 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-06 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2022-01-11 09:43:14 | SENT TO ROBBIE FOR PEER REVIEW. CT |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
F |
Date |
2021-09-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-23 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-07 |
Time |
07:22 |
Sent To |
|
|
| Notes |
| 2021-09-09 13:28:57 | PLAN REVIEW / NFIP | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SECTION A5. LATITIUDE AND LONGITUDE ARE INCORRECT. | | | CORRECT AND RE-SUBMIT. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2021-06-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-28 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-25 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2021-06-28 12:50:41 | PLAN REVIEW / NFIP | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | | | | PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | | (SFHA). IT IS LOCATED IN ZONE AE WITH BASE FLOOD | | | ELEVATIONS OF 6.0 FEET AND 7.0 FEET NAVD. DESIGN FLOOD | | | ELEVATION SHALL BE 9.0 FEET NAVD. | | | | | | 1. PROVIDE A CONSTRUCTION DRAWING ELEVATION CERTIFICATE | | | (EC) | | | | | | THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | | (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS | | | AE WITH BASE FLOOD ELEVATIONS (BFE) OF 6.0 FEET AND 7.0 | | | FEET NAVD. THE CITY OF WEST PALM BEACH (THROUGH CITY | | | ORDINANCE NO. 4729-17) REQUIRES AN ADDITIONAL 24 INCHES | | | OF FREEBOARD REQUIRING THE DESIGN FLOOD ELEVATION (DFE) | | | TO BE 9. 0 FEET NAVD. PLEASE NOTE THIS INFORMATION ON | | | YOUR PLANS. | | | | | | NOTICE: | | | | | | 3 EC S REQUIRED | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | | BUILDING. | | | | | | 2. INDICATE THE FINISHED FLOOR ELEVATIONS OF THE MAIN | | | RESIDENCE AND GARAGE ON THE FLOOR THE PLAN AND/OR | | | FOUNDATIUON PLAN. | | | R322.2.1ELEVATION REQUIREMENTS. | | | | | | 3. FLOOD OPENINGS: | | | | | | 1) PROVIDE FLOOD OPENINGS DESIGNED BY A DESIGN | | | PROFESSIONAL PER R322.2.2 ENCLOSED AREA BELOW DESIGN | | | FLOOD ELEVATION. | | | 2) SIGNATURE AND SEAL OF DESIGNER IS REQUIRED. | | | | | | ENGINEERED FLOOD VENTS: | | | | | | 1) PROVIDE ENGINEERED FLOOD VENTS. (SMART VENTS) | | | 2) ATTACH A COPY OF THE INDIVIDUAL ENGINEERED FLOOD | | | VENT CERTIFICATION OR EVALUATION SERVICE REPORT ISSUED | | | BY THE INTERNATIONAL CODE COUNCIL EVALUATION SERVICE | | | (ICC ES). | | | 3) PROVIDE FLORIDA PRODUCT APPROVALS OR MIAMI DADE | | | NOA?S FOR PROPOSED SMART VENTS. | | | 4) FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | 5) FLOOD OPENINGS SHALL BE INSTALLED PER | | | R322.2.2.1INSTALLATION OF OPENINGS. | | | 6) SHOW NUMBER AND LOCATION OF FLOOD OPENINGS ON | | | FOUNDATION PLAN. | | | | | | FBC R322.2.2.1INSTALLATION OF OPENINGS. | | | THE WALLS OF ENCLOSED AREAS SHALL HAVE OPENINGS | | | INSTALLED SUCH THAT: | | | 1. 1.THERE SHALL BE NOT LESS THAN TWO OPENINGS ON | | | DIFFERENT SIDES OF EACH ENCLOSED AREA; IF A BUILDING | | | HAS MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOOD | | | ELEVATION, EACH AREA SHALL HAVE OPENINGS. | | | 2. 2.THE BOTTOM OF EACH OPENING SHALL BE NOT MORE THAN | | | 1 FOOT (305 MM) ABOVE THE HIGHER OF THE FINAL INTERIOR | | | GRADE OR FLOOR AND THE FINISHED EXTERIOR GRADE | | | IMMEDIATELY UNDER EACH OPENING. | | | 3. 3.OPENINGS SHALL BE PERMITTED TO BE INSTALLED IN | | | DOORS AND WINDOWS; DOORS AND WINDOWS WITHOUT INSTALLED | | | OPENINGS DO NOT MEET THE REQUIREMENTS OF THIS SECTION | | | | | | NOTICE: EC PROVISO'S ON PLAN PAGES A1.0 AND A1.1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-06-03 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-06-03 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-06-03 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2021-06-09 08:47:05 | 06/03/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2022-04-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-19 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-04-19 |
Time |
12:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2022-01-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-07 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-06 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2022-01-07 15:29:41 | PLAN REVIEW ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: THERE ARE THREE (3) ROOF TYPES PROPOSED: | | | A) MODIFIED BITUMEN BUILT UP ROOF SYSTEM WITH TAPERED | | | INSULATION OVER 5/8" PLYWOOD DECK. (PLAN PAGE A3.0) | | | B) STANDING SEAM METAL ROOF OVER MODIFIED BITUMEN | | | (SECONDARY WATER BARRIER) OVER 5/8" PLYWOOD DECK. (PLAN | | | PAGE A3.1) | | | C) 10" HOLLOW CORE PLANK WITH 2" CONCRETE TOPPING.(PLAN | | | PAGE A3.0). WHITE COOL DECK FINISH. (PLAN PAGE A1.3) | | | WHAT IS THE ROOF COVERING FOR THIS AREA? | | | | | | 1.REFERENCE PLAN PAGE S2.0 FOR THE FOLLOWING: | | | DESIGN CRITERIA PER ARCHITECT OF RECORD (AOR) FOR | | | PROPOSED STRUCTURE IS RISK FACTOR (1), EXPOSURE "D", | | | ENCLOSED BUILDING. | | | SYSTEM W-1, SELECTED TO BE INSTALLED FROM PRODUCT | | | APPROVAL FL16709-R7, PG. 6 OF 25, IS NOT APPROVED FOR | | | EXPOSURE "D" ENCLOSED. | | | SUBMIT A ROOFING SYSTEM APPROVED FOR EXPOSURE "D", | | | ENCLOSED, 20-30FT MRH. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR STANDING SEAM METAL | | | ROOFING. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR TYPE (C) ROOF ABOVE. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-09-23 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-09-07 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2021-09-07 13:24:14 | PLAN REVIEW ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. ROOFING PERMIT REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | (NOT ADDRESSED) | | | | | | 2. MAX DESIGN PRESSURE OF CERTAINTEED SBS AND APP | | | MODIFIED BITUMEN ROOF SYSTEM IS -97.5. PROVIDE THE | | | DESIGN PRESSURES OF ROOF ZONES 1, 2 AND THRE PER | | | R301.2.1.1. | | | PROVIDE DESIGN PRESSURES PER FIGURE R301.2(7) COMPONENT | | | AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | (NOT ADDRESSED) | | | | | | NEW COMMENTS: | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR METAL ROOF. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 4. PROVIDE PRODUCT APPROVALS FOR DOUBLE ROOF HATCH AT | | | 3RD FLOOR. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-06-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-06-28 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-25 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2021-06-28 10:58:05 | PLAN REVIEW ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOFING PERMIT REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2. MAX DESIGN PRESSURE OF CERTAINTEED SBS AND APP | | | MODIFIED BITUMEN ROOF SYSTEM IS -97.5. PROVIDE THE | | | DESIGN PRESSURES OF ROOF ZONES 1, 2 AND THRE PER | | | R301.2.1.1. | | | PROVIDE DESIGN PRESSURES PER FIGURE R301.2(7) COMPONENT | | | AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | | | | NOTICE: SEE COMMENTS UNDER BUILDING REVIEW. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
N |
Date |
2022-07-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-07 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-06 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2022-07-07 08:10:15 | LETTER FROM CONTRACTOR TO RB ON 6/30/2022, PLEASE | | | REVOKE PERMIT. OWNERS DO NOT WANT TO PROCEED. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-04-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-04-22 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-04-19 |
Time |
12:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-01-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-07 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-06 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2022-01-07 11:42:47 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC2017 | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-08-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-08-19 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-08-19 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2021-08-19 11:16:39 | PLANS SUBMITTED APPEAR TO HAVE A COPY OF THE DIGITAL | | | SIGNATURES ON THE MECHANICAL PLANS. PLEASE EITHER | | | SUBMIT THE DRAWINGS WITH THE DIGITAL SIGNATURES OR YOU | | | CAN BRING THE SIGNED AND SEALED PAPER DRAWINGS TO OUR | | | OFFICE. C-1 AND C-2 HAVE A COPY OF THE SIGNED AND | | | SEALED PAPER DRAWINGS. PLEASE PROVIDE THE ORIGINAL | | | SIGNED AND SEALED PAPER DRAWINGS. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-06-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-02 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-02 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2021-06-02 15:50:01 | THE ENGINEER SIGNATURE IS A COPY OF THEIR SIGNATURE. | | | PLEASE PROVIDE THE ORIGINAL DIGITAL SIGNTURES FOR ALL | | | DRAWINGS INCLUDING THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS AND THE MECHANICAL DRAWINGS. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-04-13 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-04-13 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-04-13 |
Time |
09:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-03-18 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-03-18 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2022-03-18 14:36:06 | 3/18/2022 FAILED | | | | | | PLEASE APPLY FOR A LANDSCAPE PERMIT AND OBTAIN A PERMIT | | | NUMBER TO ALLOW STAFF TO MOVE FORWARD WITH PERMIT | | | | | | PLEASE PROVIDE THE HEIGHT OF THE PROJECT STARTING FROM | | | FINISHED GRADE, NOT FIRST FLOOR GRADE ON ELEVATION | | | PLANS | | | | | | VALENTINA BROGLIA | | | ASSOCIATE PLANNER | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-06-22 |
|
|
Cont ID |
|
| Sent By |
RTHERMID |
Date |
2021-06-22 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2021-06-22 |
Time |
|
Sent To |
I |
|
| Notes |
|
|