| Plan Review Stops For Permit 21040592 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-06-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-06-16 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-06-16 |
Time |
17:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-06-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-06-08 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-06-07 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2021-06-07 10:06:03 | REVISED 06/08/21 | | | | | | NEW DOCK BUILDING, SECOND REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21040592 | | | | | | 1- OK | | | 2- OK | | | 3- OK | | | | | | ORIGINAL COMMENT: | | | 4- PROVIDE SIGNED/SEALED ENGINEERING FOR THE TWO | | | BOAT-LIFT SPECIFIED ON PLANS. ENGINEER OF RECORD TO | | | REVIEW AND APPROVE THEM PRIOR TO SUBMITTAL. SEC. | | | 107.3.4.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | 4(A)- BOAT LIFT ENGINEERING SUBMITTED SUBMITTED WAS NOT | | | REVIEWED/APPROVED BY THE DOCK ENGINEER OF RECORD. IT | | | NEEDS TO BE APPROVED BY THE ENGINEER OF RECORD. SEC. | | | 107.3.4.1 CITY AMENDMENTS. | | | | | | 4(B) BOAT LIFT CAPACITY MARKED ON BOAT LIFT ENGINEERING | | | SUBMITTED DOESN'T MATCH BOAT LIFT CAPACITY SPECIFIED BY | | | THE DOCK ENGINEER OF RECORD ON SHEET 2. REVISE AS | | | REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 4(C)BOAT LIFT ENGINEERING SUBMITTED. ELECTRONICALLY | | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ENGINEER'S | | | DIGITAL SIGNATURE ON THEM WHEN SUBMITTING FOR PUBLIC | | | RECORDS. FS 471 & 61G15 | | | YOU ALSO HAVE THE OPTION TO SUBMIT THE PAPER VERSION OF | | | DRAWINGS WITH THE ENGINEER'S ORIGINAL HANDWRITTEN | | | SIGNATURE AND SEAL. | | | | | | 5- OK | | | | | | ORIGINAL COMMENT: | | | 6- SURVEY NEEDS ORIGINAL SEAL/SIGNATURE AS REQUIRED BY | | | CHAPTER 472 F.S. WHEN SUBMITTING PLANS/DOCUMENTS FOR | | | PUBLIC RECORDS. PROVIDE HARD COPY WITH ORIGINAL | | | SEAL/SIGNATURE OR UPLOAD SURVEY WITH DIGITAL SIGNATURE. | | | | | | RESPONSE: | | | 06/07/21 PER ROBERT BROWN: OK TO USE THE SURVEY WITH | | | THE PROPOSED DOCK JUST AS A REFERENCE AS LONG AS THE | | | ENGINEER OF RECORD SHOWS SITE PLAN WITH PROPOSED DOCK. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-04-28 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-04-28 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2021-04-28 13:54:35 | NEW DOCK BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21040592 | | | | | | 1- DESIGN CRITERIA ON DOCK CONSTRUCTION NOTES ON SHEET | | | #2 IS MISSING THE STRUCTURE WIND EXPOSURE. ENGINEER OF | | | RECORD TO SPECIFY ALL THE WIND DESIGN DATA, INCLUDING | | | THE ULTIMATE AND NOMINAL WIND LOADS AND WIND EXPOSURE. | | | SEC. R301.1 FBC-RESIDENTIAL. SEC. R301.2.1 | | | FBC-RESIDENTIAL. | | | NOTE: THIS STRUCTURE IS LOCATED IN EXPOSURE D. | | | | | | 2- ENGINEER OF RECORD TO SPECIFY THE DECKING FASTENING | | | TO SHOW COMPLIANCE WITH THE SPECIFIED WIND DESIGN | | | CRITERIA. | | | SEC. R301.2.1 FBC-RESIDENTIAL. | | | | | | 3- ENGINEER PLANS NEED TO HAVE A TITLE BLOCK WITH ALL | | | THE ENGINEER'S INFORMATION AS REQUIRED BY SEC. | | | 61G15-23.001(4) F.A.C. | | | | | | 4- PROVIDE SIGNED/SEALED ENGINEERING FOR THE TWO | | | BOAT-LIFT SPECIFIED ON PLANS. ENGINEER OF RECORD TO | | | REVIEW AND APPROVE THEM PRIOR TO SUBMITTAL. SEC. | | | 107.3.4.1 CITY AMENDMENTS. | | | NOTE: THIS MAY BE SUBMITTED FOR REVIEW LATER AFTER THE | | | PERMIT IS ISSUED BUT BEFORE INSTALLATION TO AVOID | | | CONFLICTS/DELAYS. | | | | | | 5- DOCK DRAWINGS: ELECTRONICALLY SUBMITTED DRAWINGS ARE | | | REQUIRED TO HAVE THE ENGINEER'S DIGITAL SIGNATURE ON | | | THEM WHEN SUBMITTING FOR PUBLIC RECORDS. | | | YOU ALSO HAVE THE OPTION TO SUBMIT THE PAPER VERSION OF | | | DRAWINGS WITH THE ENGINEER?S ORIGINAL HANDWRITTEN | | | SIGNATURE AND SEAL. AFTER THE ELECTRONIC PLANS HAVE | | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS | | | REQUIRED TO BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER | | | FACSIMILES OF THE SIGNATURE ARE ACCEPTABLE. FS 471 & | | | 61G15 | | | | | | 6- SURVEY NEEDS ORIGINAL SEAL/SIGNATURE AS REQUIRED BY | | | CHAPTER 472 F.S. WHEN SUBMITTING PLANS/DOCUMENTS FOR | | | PUBLIC RECORDS. PROVIDE HARD COPY WITH ORIGINAL | | | SEAL/SIGNATURE OR UPLOAD SURVEY WITH DIGITAL SIGNATURE. | | | | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-06-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-15 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-15 |
Time |
13:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-06-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-01 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-05-27 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2021-06-01 07:28:54 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | 1) NEED TO SHOW LOCATION OF PEDESTAL, IF ON DOCK THEN | | | GFCI IS REQUIRED TO THE PEDESTAL. 555.3 | | | | | | 555.3 GROUND-FAULT PROTECTION. THE OVERCURRENT | | | PROTECTIVE DEVICES THAT SUPPLY THE MARINA, BOATYARDS, | | | AND COMMERCIAL AND NONCOMMERCIAL DOCKING FACILITIES | | | SHALL HAVE GROUND-FAULT PROTECTION NOT EXCEEDING 30 MA. | | | | | | 2) NEED TO SUBMIT CUTSHEET FOR PEDESTAL. 110.3 | | | | | | 3) THE USE OF EXPANSION FITTINGS WILL BE REQUIRED. | | | 352.44 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-04-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-04-29 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-04-29 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2021-04-29 12:27:06 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NEED TO SHOW WHERE MAIN IS TO SUBPANEL AND SEE IF IT | | | COMPLIES WITH 555.3 | | | | | | ELECTRICAL CONNECTION SHALL COMPLY WITH 555.9 | | | | | | EQUIPMENT GROUNDING TO BE PER 555.15 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2021-05-12 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-05-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2021-05-12 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-06-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-24 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-06-10 |
Time |
10:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-06-07 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-05-25 |
Time |
11:39 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-05-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-05-13 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-04-09 |
Time |
09:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-06-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-06-16 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-06-16 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2021-06-15 14:02:22 | ELECTRICAL SIGNATURE IS GOOD JLEAHY |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-06-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-06-07 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-06-07 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2021-06-07 10:07:44 | SIGNATURE REVIEW COMMENTS: | | | | | | 1-- SURVEY WITH PROPOSED DOCK NEEDS ORIGINAL | | | SEAL/SIGNATURE AS REQUIRED BY CHAPTER 472 F.S. WHEN | | | SUBMITTING PLANS/DOCUMENTS FOR PUBLIC RECORDS. PROVIDE | | | HARD COPY WITH ORIGINAL SEAL/SIGNATURE OR UPLOAD SURVEY | | | WITH DIGITAL SIGNATURE. | | | | | | 2- BOAT LIFT ENGINEERING SUBMITTED. ELECTRONICALLY | | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ENGINEER'S | | | DIGITAL SIGNATURE ON THEM WHEN SUBMITTING FOR PUBLIC | | | RECORDS. FS 471 & 61G15 | | | YOU ALSO HAVE THE OPTION TO SUBMIT THE PAPER VERSION OF | | | DRAWINGS WITH THE ENGINEER'S ORIGINAL HANDWRITTEN | | | SIGNATURE AND SEAL. | | | | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | 2021-06-01 07:29:49 | ELECTRIC SIGNATURE IS GOOD. JLEAHY |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-04-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-04-28 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-04-28 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2021-04-28 13:55:48 | SIGNATURE REVIEW COMMENTS: | | | | | | 1- DOCK DRAWINGS: ELECTRONICALLY SUBMITTED DRAWINGS ARE | | | REQUIRED TO HAVE THE ENGINEER'S DIGITAL SIGNATURE ON | | | THEM WHEN SUBMITTING FOR PUBLIC RECORDS. | | | YOU ALSO HAVE THE OPTION TO SUBMIT THE PAPER VERSION OF | | | DRAWINGS WITH THE ENGINEER?S ORIGINAL HANDWRITTEN | | | SIGNATURE AND SEAL. AFTER THE ELECTRONIC PLANS HAVE | | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS | | | REQUIRED TO BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER | | | FACSIMILES OF THE SIGNATURE ARE ACCEPTABLE. FS 471 & | | | 61G15 | | | | | | 2- SURVEY NEEDS ORIGINAL SEAL/SIGNATURE AS REQUIRED BY | | | CHAPTER 472 F.S. WHEN SUBMITTING PLANS/DOCUMENTS FOR | | | PUBLIC RECORDS. PROVIDE HARD COPY WITH ORIGINAL | | | SEAL/SIGNATURE OR UPLOAD SURVEY WITH DIGITAL SIGNATURE. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-06-22 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-06-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2021-06-22 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-05-11 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-05-11 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2021-05-11 |
Time |
|
Sent To |
I |
|
| Notes |
|
|