Plan Review Details - Permit 21040567
Plan Review Stops For Permit 21040567
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-07-08 Cont ID  
Sent By rmcdouga Date 2021-07-08 Time 17:53 Rev Time 0.00
Received By rmcdouga Date 2021-07-08 Time 17:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-06-25 Cont ID  
Sent By jleahy Date 2021-06-25 Time 13:02 Rev Time 0.00
Received By jleahy Date 2021-06-25 Time 12:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2021-06-07 Cont ID  
Sent By equinone Date 2021-06-07 Time 14:59 Rev Time 0.00
Received By equinone Date 2021-06-07 Time 14:58 Sent To  
Notes
2021-06-07 14:59:22CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW:
  
 1) DRAWINGS SUBMITTED MUST HAVE SIGNATURE, NAME, AND
 LICENSE NUMBER OF CONTRACTOR QUALIFIER (THE CONTRACTOR
 PULLING THE PERMIT) NOT SOMEBODY ELSE.
  
 ENRIQUE QUINONEZ PE
 ELECTRICAL PLANS EXAMINER
 DEVELOPMENT SERVICES
 CITY OF WEST PAM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6746.
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-04-27 Cont ID  
Sent By equinone Date 2021-04-27 Time 10:05 Rev Time 0.00
Received By equinone Date 2021-04-27 Time 10:05 Sent To  
Notes
2021-04-27 10:31:37CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW:
  
 1) PER THE WPB AMENDMENTS TO THE FBC, PLAN (EACH SHEET
 OF BOTH COPIES) IS REQUIRED TO BEAR THE NAME AND BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. THIS PERSON MUST BE A LICENSED DESIGN
 PROFESSIONAL
 OR THE ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE
 CORRECTION. WPB FBC 107.1, 107.2; FS 471, 481
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 1) DRAWINGS SUBMITTED MUST HAVE SIGNATURE, NAME, AND
 LICENSE NUMBER OF CONTRACTOR QUALIFIER. FBC 107
  
 ENRIQUE QUINONEZ PE
 ELECTRICAL PLANS EXAMINER
 DEVELOPMENT SERVICES
 CITY OF WEST PAM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6746.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2021-06-18 Cont ID  
Sent By pleduc Date 2021-06-18 Time   Rev Time 0.00
Received By pleduc Date 2021-06-18 Time 13:00 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-06-04 Cont ID  
Sent By pleduc Date 2021-06-04 Time   Rev Time 0.00
Received By pleduc Date 2021-06-04 Time 16:37 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-05-06 Cont ID  
Sent By bdolan Date 2021-05-06 Time   Rev Time 0.00
Received By pleduc Date 2021-05-06 Time 10:45 Sent To  
Notes
2021-05-06 10:50:24THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE ARE INDICATIONS THAT THIS IS NG GENERATOR.
  
 THERE ARE NO INDICATION OF THE LOCATION, SIZE AND
 INSTALLATION OF PIPING.
  
 PLEASE PROVIDE DETAILS AND EQUIPMENT SPEC SHEETS.
  
  
 1A) THERE IS NO INDICATION OF COMPLIANCE WITH NFPA 54,
 NATIONAL FUEL GAS CODE NOR OTHER APPLICABLE NFPA CODES.
  
 PLEASE REVIEW, ENSURE COMPLIANCE AND PROVIDE A NOTE OF
 ACKNOWLEDGEMENT.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-06-16 Cont ID  
Sent By ccole Date 2021-06-16 Time 13:06 Rev Time 0.00
Received By ccole Date 2021-06-16 Time 12:23 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-05-24 Cont ID  
Sent By ccole Date 2021-05-24 Time 17:13 Rev Time 0.00
Received By ccole Date 2021-05-24 Time 16:07 Sent To  
Notes
2021-05-24 17:13:531ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 21040567
 5/24/2021
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE CONTRACTOR STATE REGISTRATION #25614 FOR CHARLES
 P. ERKMAN WHICH IS SHOWN ON THE APPLICATION AND ON THE
 GAS RISER EXPIRED ON 8/31/2020. THE CONTRACTOR OF
 RECORD JARED P. REIFF SHALL PROVIDE HIS UP-TO-DATE
 REGISTRATION #32824 ON THE DOCUMENTS- SECTION 105.1
 WPB.
  
 2) GAS RISER: PROVIDE A COMPLETE GAS LAYOUT PLAN
 DRAWING THAT INCLUDES ALL NEW AND EXISTING GAS PIPING
 AND APPLIANCES BEING SUPPLIED BY THE METER- SECTIONS
 401.3 & 401.4 FBC FG. PLEASE LABEL THE METER AS NEW OR
 EXISTING ON THE PLAN AND THE RISER AND INCLUDE THE
 FOLLOWING ITEMS PER SECTION 107.3.5.3 WPB:
  
 A) DELIVERY PRESSURE AT THE METER.
 B) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 C) TYPES AND SIZES OF PIPING.
 D) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 E) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 F) LOCATIONS OF REGULATORS, SHUTOFF VALVES, PIPE
 UNIONS, FLEX CONNECTORS.
 G) OUTLET PRESSURES AT REGULATORS.
 H) LOCATIONS AND TYPES OF PIPE SLEEVES.
 I) PIPE SIZING TABLES.
  
 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE
 GENERATOR AND FLEX CONNECTOR- SECTIONS 305.1, 411.1 AND
 411.1.4 FBC FG.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 CCOLE@WPB
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-07-08 Cont ID  
Sent By rmcdouga Date 2021-07-08 Time 17:54 Rev Time 0.00
Received By rmcdouga Date 2021-06-17 Time 09:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2021-06-16 Time   Rev Time 0.00
Received By aoliver Date 2021-06-03 Time 09:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-24 Cont ID  
Sent By ccole Date 2021-05-24 Time 17:15 Rev Time 0.00
Received By ccole Date 2021-04-12 Time 07:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2021-06-16 Cont ID  
Sent By ccole Date 2021-06-16 Time 13:07 Rev Time 0.00
Received By ccole Date 2021-06-16 Time 12:23 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-07-08 Cont ID  
Sent By rmcdouga Date 2021-07-08 Time 17:53 Rev Time 0.00
Received By rmcdouga Date 2021-07-08 Time 17:53 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-06-07 Cont ID  
Sent By equinone Date 2021-06-07 Time 14:59 Rev Time 0.00
Received By equinone Date 2021-06-07 Time 14:59 Sent To  
Notes
2021-06-07 15:00:22CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 REVIEW STATUS: FAILED. PLEASE SEE COMMENTS BELOW:
  
 1) DRAWINGS SUBMITTED MUST HAVE SIGNATURE, NAME, AND
 LICENSE NUMBER OF CONTRACTOR QUALIFIER (THE CONTRACTOR
 PULLING THE PERMIT) NOT SOMEBODY ELSE.
  
 ENRIQUE QUINONEZ PE
 ELECTRICAL PLANS EXAMINER
 DEVELOPMENT SERVICES
 CITY OF WEST PAM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6746.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-05-24 Cont ID  
Sent By ccole Date 2021-05-24 Time 17:24 Rev Time 0.00
Received By ccole Date 2021-05-24 Time 16:11 Sent To  
Notes
2021-05-24 17:24:54ELECTRONIC/DIGITAL SIGNATURE REVIEW FBC- 2020
 PERMIT- 21040567
 5/24/2021
  
 CODES IN EFFECT:
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
 THE FOLLOWING REVIEW IS FOR THE GENERATOR PRECAST PAD
 ONLY
  
 1) THE ENGINEER OF RECORD HAS PLACED LIMITATIONS OF USE
 FOR THE DIGITAL SIGNATURE AND SEAL ON THE PRECAST
 GENERATOR PAD- ?VALID ONLY FOR ZIPCODE 33432? AND ?FOR
 USE WITH 14 DAYS OF DIGITAL SEAL?. THE SEAL IS EXPIRED
 BASED ON THE SEAL DATE OF 2021.02.22.
  
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR
 ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND
 DOCUMENTS.
 A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL
 ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY
 CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION.
 THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE
 A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES
 NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.)
 YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE
 ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT
 USE A THIRD PARTY.
 YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT
 IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE
 AND DOCUMENT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2021-07-06 Cont ID  
Sent By rthermid Date 2021-07-06 Time   Rev Time 0.00
Received By rthermid Date 2021-07-06 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-06-11 Cont ID  
Sent By rthermid Date 2021-06-11 Time   Rev Time 0.00
Received By rthermid Date 2021-06-11 Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2021-05-20 Cont ID  
Sent By rthermid Date 2021-05-20 Time   Rev Time  
Received By rthermid Date 2021-05-20 Time   Sent To I
Notes
2021-05-20 12:04:27ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 5/21/2021
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PER THE FLORIDA BUILDING CODE, GENERATORS MUST BE
 SETBACK A MINIMUM OF 10 FEET FROM ANY DOORS AND WINDOW
 OPENINGS.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN
 INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
  
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 RAFAELA THERMIDOR, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 TTY: 800.955.8771
 E: [email protected]
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved