Plan Review Details - Permit 21040327
Plan Review Stops For Permit 21040327
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-04-12 Cont ID  
Sent By cpuell Date 2021-04-12 Time 12:00 Rev Time 0.00
Received By cpuell Date 2021-04-12 Time 12:00 Sent To  
Notes
2021-04-12 12:01:19ADDRESS CHANGED FROM 2018 FLORIDA AVE TO 529 BISCAYNE
 DR DUE TO RELOCATION OF FRONT DOOR.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-04-08 Cont ID  
Sent By cpuell Date 2021-04-08 Time 17:57 Rev Time 0.00
Received By cpuell Date 2021-04-12 Time 12:00 Sent To  
Notes
2021-04-08 17:57:43RENOVATIONS CHANGING THE ENTRANCE TO THE PROPERTY,
 WORKING WITH OWNER TO ESTABLISH A NEW ADDRESS

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-06-30 Cont ID  
Sent By rmcdouga Date 2021-06-30 Time 11:37 Rev Time 0.00
Received By rmcdouga Date 2021-06-30 Time 11:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-06-23 Cont ID  
Sent By rmcdouga Date 2021-06-23 Time 13:08 Rev Time 0.00
Received By rmcdouga Date 2021-06-23 Time 13:08 Sent To  
Notes
2021-06-23 12:09:05PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT A COPY OF A BOUNDARY SURVEY OF THE PROPERTY
 FOR COMPARISON WITH THE SITE PLAN. FBC 107.2.5
  
 2) THE PRODUCT APPROVAL (FL-17184.2) FOR THE 5' X 8'
 DOUBLE OUTSWING FRENCH DOORS HAS A MAXIMUM DESIGN
 PRESSURE OF -45 PSF. THE DOOR PRESSURE SCHEDULE ON
 SHEET S.0 HAS THE REQUIRED WIND LOAD PRESSURE AS -52.27
 PSF. SUBMIT A PRODUCT APPROVAL FOR THESE DOORS WITH AN
 ADEQUATE DESIGN PRESSURE. FBC AMEND. 107.3.4
  
 3) THE DESIGN PRESSURES IN THE GAF MODIFIED BITUMEN
 ROOFING PRODUCT APPROVAL (NOA NO. 18-0919.12) ARE NOT
 ADEQUATE FOR ALL OF THIS STRUCTURE'S ROOF ZONES.
 SPECIFY WHICH ONE OF THE APPROVED ASSEMBLIES, FASTENING
 OPTION AND DESIGN PRESSURE WILL BE INSTALLED. SELECT
 ONE THAT ALLOWS ENHANCED FASTENING TO INCREASE THE
 DESIGN PRESSURES AND SUBMIT SIGNED AND SEALED RAS 117
 ENHANCED FASTENING CALCULATIONS. FBC AMEND. 107.1
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-05-05 Cont ID  
Sent By rmcdouga Date 2021-05-05 Time 14:44 Rev Time 0.00
Received By rmcdouga Date 2021-05-05 Time 08:29 Sent To  
Notes
2021-05-05 13:26:58PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE ADDRESS OF THE PROJECT SPECIFIED ON THE PLANS OF
 2018 FLORIDA AVE. DOES NOT MATCH THE RECORDS OF THE
 CITY OF WEST PALM BEACH OR THE PALM BEACH COUNTY
 PROPERTY APPRAISER'S OFFICE. THE ADDRESS OF RECORD FOR
 THIS PROPERTY IS 529 BISCAYNE DRIVE. PLEASE MAKE
 CORRECTIONS TO THE PLANS TO REFLECT THE CORRECT
 ADDRESS. FBC AMENDMENTS 107.2.1
  
 2) THE DRIVEWAY, POOL, LANDSCAPING AND FENCES REQUIRE
 SEPARATE PERMITS. PLEASE MAKE SURE THAT THE COSTS OF
 THESE ITEMS ARE NOT INCLUDED IN THE VALUE FOR THIS
 PROJECT. OTHERWISE, YOU WILL BE PAYING TWICE FOR ITEMS
 THAT REQUIRE A SEPARATE PERMIT. FBC AMENDMENTS 109.3
  
 3) ON SHEET A1.0, UNDER APPLICABLE CODES THE 2020 FBC
 EXISTING BUILDING CODE IS APPLICABLE BUT IS NOT LISTED.
 FBC AMENDMENTS 107.2.1
  
 4) ALSO ON A1.0, THE BUILDING OCCUPANCY IS SPECIFIED AS
 RESIDENTIAL (TOWNHOUSE). THIS PROJECT IS FOR A DETACHED
 SINGLE FAMILY HOME, NOT A TOWNHOUSE. PLEASE CORRECT.
 FBC AMENDMENTS 107.2.1
  
 5) ON SHEET S.0, IN THE LOAD SCHEDULE UNDER WIND, THE
 MEAN ROOF HEIGHT IS SPECIFIED AS 27'-4" FOR THE ON
 STORY STRUCTURE AND THE ROOF SLOPE IS LISTED AS 6:12
 WHEN THE SLOPED ROOF AT THE PORCH IS 3:12 AND MOST OF
 THE BUILDING HAS A FLAT ROOF. PLEASE CORRECT. FBC
 AMENDMENTS107.2.1
  
 6) SUBMIT THE APPROPRIATE FORMS TO SHOW HOW THE PROJECT
 WILL COMPLY WITH THE 2020 FBC ENERGY CONSERVATION CODE.
 CHAPTER 5 [RE]
  
 7) THE PLANS DO NOT SHOW A LANDING AT THE EXTERIOR OF
 THE EAST DOOR OF THE PROPOSED KITCHEN. R311.3 FLOORS
 AND LANDINGS AT EXTERIOR DOORS. THERE SHALL BE A
 LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR.
 THE WIDTH OF EACH LANDING SHALL BE NOT LESS THAN THE
 DOOR SERVED. EVERY LANDING SHALL HAVE A DIMENSION OF
 NOT LESS THAN 36 INCHES (914 MM) MEASURED IN THE
 DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR LANDINGS
 SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS
 HORIZONTAL (2 PERCENT).
  
 8) THE PRODUCT APPROVAL FOR THE PLASTIPRO EXTERIOR DOOR
 FL17184.7 IS MISSING THE COVERSHEET WHICH SHOWS WHICH
 SHOWS THE CODE EDITION WITH WHICH IT COMPLIES. THE ONLY
 CODE EDITION ON THE DRAWINGS IS THE 2014 FBC 5TH
 EDITION. SUBMIT THE COVERSHEET AND DRAWINGS FOR THE
 2020 FBC SEVENTH EDITION.
  
 9) PLEASE HI-LIGHT OR CIRCLE THE APPROPRIATE ITEMS,
 SIZES, GLASS TYPES AND THEIR DESIGN PRESSURES IN EACH
 OF THE PRODUCT APPROVALS FOR THE SPECIFIC ONE THAT WILL
 BE USED. THERE ARE MULTIPLE ITEMS THAT HAVE DIFFERENT
 DESIGN PRESSURES DUE TO SUCH THINGS AS GLASS TYPE, ETC.
 IN THE PRODUCT APPROVAL. FBC AMENDMENTS 107.2.1 & FAC
 61G20-3.001
  
 10) SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE USED
 FOR THE CLAY TILE ROOF, NOA NO. 17-0719.07, AND SUBMIT
 THE PRODUCT APPROVAL FOR THE ROOF TILE ADHESIVE THAT
 WILL BE USED. FBC AMENDMENTS FBC AMENDMENTS 107.3.4 &
 FAC 61G20-3.001
  
 11) THE PLANS SPECIFY A MODIFIED BITUMEN ROOF COVERING,
 NOA NO. 14-0529.02 OVER MINIMUM R-19 RIGID INSULATION
 BOARD ON THE FLAT ROOF OVER CONDITIONED SPACE. THE
 PRODUCT APPROVAL THAT WAS SUBMITTED, FL5293 IS MISSING
 THE COVERSHEET AND THE SYSTEM THAT IS HI-LIGHTED, W-37,
 IS FOR A TPO ROOF WITH A MAXIMUM UPLIFT PRESSURE OF
 -82.5 PSF. THE STRUCTURAL PLANS REQUIRE -92.7 PSF AND
 -126.3 PSF IN ROOF ZONES 2 AND 3. YOU WILL NEED TO
 PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS TO
 DETERMINE ENHANCED FASTENING IN ORDER TO ACHIEVE
 INCREASED UPLIFT PRESSURES. YOU WILL ALSO NEED TO
 CORRELATE THE PLANS WITH THE PRODUCT APPROVALS. WHEN
 SUBMITTING PRODUCT SUCH AS THIS WITH OVER 100 PAGES
 CONTAINING MANY DIFFERENT ROOFING SYSTEMS FOR DIFFERENT
 APPLICATIONS YOU SHOULD SUBMIT ONLY THE PAGES THAT
 PERTAIN TO THE SYSTEM THAT YOU PROPOSE TO INSTALL. THIS
 WILL TYPICALLY INCLUDE THE FIRST FIVE OR SIX PAGES AND
 THEN THE TWO OR THREE SHEETS THAT HAVE THE INFORMATION
 FOR THE SPECIFIC SYSTEM. FBC-R 301 & FBC AMENDMENTS
 107.3.4
  
 12) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-04-27 Cont ID  
Sent By jleahy Date 2021-04-27 Time 15:05 Rev Time 0.00
Received By jleahy Date 2021-04-27 Time 14:43 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-06-10 Cont ID  
Sent By ccole Date 2021-06-10 Time 11:36 Rev Time 0.00
Received By ccole Date 2021-06-10 Time 08:39 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-04-23 Cont ID  
Sent By ccole Date 2021-04-23 Time 13:05 Rev Time 0.00
Received By ccole Date 2021-04-23 Time 11:44 Sent To  
Notes
2021-04-23 13:06:151ST REVIEW FBC-2020 RES. FUEL GAS
 PERMIT- 21031243
 4/22/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P0.2 GAS RISER- PLEASE PROVIDE THE FOLLOWING
 LIST OF INFORMATION PER FBC RES. FUEL GAS
  
 A) DELIVERY PRESSURES AT FIRST AND SECOND STAGE
 REGULATORS- SECTIONS G2413.2 & G2421.2.
  
 C) TOTAL BTU LOAD- G2413.2
  
 D) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET- G2413.4.1.
  
 E) LOCATIONS AND TYPES OF PIPE SLEEVES- G2415.1.
  
 F) EHD OF THE CSST PIPING- G413.3 & G2415.2.
  
 G) SHOW THE REQUIRED UNIONS PIPE UNIONS WITHIN 1 FT. OF
 EITHER SIDE OF THE REGULATORS CONNECTED TO RIGID
 PIPING- G2421.2(7).
  
 H) LIST THE PIPE SIZING TABLES OR PIPE SIZING METHOD
 USED- G2413.3.
  
 2) P0.2 & P1.1: PROVIDE A TRACER WIRE FOR THE UG PE
 PIPING PER SECTION G2415.17.3. A YELLOW INSULATED
 COPPER TRACER WIRE OR OTHER APPROVED CONDUCTOR, OR A
 PRODUCT SPECIFICALLY DESIGNED FOR THAT PURPOSE, SHALL
 BE INSTALLED ADJACENT TO UNDERGROUND NONMETALLIC
 PIPING. THE TRACER WIRE SIZE SHALL NOT BE LESS THAN 18
 AWG AND THE INSULATION TYPE SHALL BE SUITABLE FOR
 DIRECT BURIAL.
  
 3) P0.2 & P1.1: PROVIDE COMBUSTION AIR CALCULATIONS AND
 INDICATE HOW THE AIR WILL BE PROVIDED TO THE GAS RANGE-
 SECTION- G2407.1 FBC RES.
  
 4) P0.2 & P1.1: PROVIDE MAKEUP AIR FOR THE DRYER AND
 INDICATE HOW THE MAKEUP AIR WILL BE PROVIDED- G2439.5
 FBC RES.
  
 5) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL GAS
 FIRED APPLIANCES- SECTION G2408.1 FBC RES.
  
 6) SUBMIT A GAS SUB-PERMIT IF THE INSTALLATIONS ARE TO
 BE INCLUDED UNDER THE MASTER PERMIT- SECTION 105.1 WPB.
 IF THE GAS INSTALLATIONS ARE TO BE UNDER A SEPARATE
 PRIMARY PERMIT, PLEASE PLACE A NOTE ON THE PLAN.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2021-04-23 Cont ID  
Sent By fmittner Date 2021-04-23 Time 16:15 Rev Time 0.00
Received By fmittner Date 2021-04-23 Time 16:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-06-30 Cont ID  
Sent By rmcdouga Date 2021-06-30 Time 11:38 Rev Time 0.00
Received By rmcdouga Date 2021-06-30 Time 09:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-06-25 Cont ID  
Sent By lmarchan Date 2021-06-25 Time 16:29 Rev Time 0.00
Received By lmarchan Date 2021-05-27 Time 14:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-05-05 Cont ID  
Sent By rmcdouga Date 2021-05-05 Time 14:45 Rev Time 0.00
Received By rmcdouga Date 2021-04-13 Time 16:18 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-07-22 Cont ID  
Sent By lmarchan Date 2021-07-22 Time 10:50 Rev Time 0.00
Received By lmarchan Date 2021-07-08 Time 08:12 Sent To  
Notes
2021-07-21 15:07:46RECEIPT MU-2021-35465 - $1945.04 PAID
2021-07-08 08:12:217/8/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2021-05-05 Cont ID  
Sent By rmcdouga Date 2021-05-05 Time 11:04 Rev Time 0.00
Received By rmcdouga Date 2021-05-05 Time 08:29 Sent To  
Notes
2021-05-05 11:05:59PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-06-08 Cont ID  
Sent By medwards Date 2021-06-08 Time 16:24 Rev Time 0.00
Received By medwards Date 2021-06-08 Time 16:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-04-26 Cont ID  
Sent By medwards Date 2021-04-26 Time 17:09 Rev Time 0.00
Received By medwards Date 2021-04-26 Time 17:09 Sent To  
Notes
2021-04-26 17:09:571ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21040327
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE KITCHEN AND DINING AREA APPEAR TO BE A NEW
 ADDITION. PLEASE PROVIDE THE REQUIRED MECHANICAL
 EQUIPMENT SIZING CALCULATIONS ALONG WITH THE SPECS FOR
 THE NEW SYSTEM. FBC EC 101.5.1.1.2
  
 2) IT APPEARS THAT THE AHU-1 IS NEW, IF THIS IS A LIKE
 FOR LIKE CHANGE OUT PLEASE SUBMIT THE LIKE FOR LIKE
 CHANGE OUT FORM. FBC 107.2.1
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-06-10 Cont ID  
Sent By ccole Date 2021-06-10 Time 11:35 Rev Time 0.00
Received By ccole Date 2021-06-10 Time 11:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-04-23 Cont ID  
Sent By ccole Date 2021-04-23 Time 11:34 Rev Time 0.00
Received By ccole Date 2021-04-23 Time 09:36 Sent To  
Notes
2021-04-23 11:34:441ST REVIEW FBC-2020 RES.
 PERMIT- 21040327
 4/23/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A2.1: PROVIDE PLUMBING PIPING DETAILS FOR THE
 WATER FEATURE IN THE MEDITATION ROOM- SECTION 107.2.1
 WPB. CLARIFY HOW WATER WILL BE SUPPLIED TO THE FEATURE,
 AND HOW WATER FROM THE FEATURE WILL BE DISCHARGED AND
 DRAINED TO AN APPROVED LOCATION. PLEASE INCLUDE AN
 EQUIPMENT SCHEDULE ON THE PLAN AND SUBMIT
 MANUFACTURER'S SPECIFICATIONS. IF THE INSTALLATION IS
 TO BE UNDER A SEPARATE PERMIT, PLEASE PLACE A NOTE ON
 THE PLAN- SECTION 105.1 WPB.
  
 2) A5.3: PROVIDE THE REQUIRED 1/4 IN. SLOPE FOR THE
 SHOWER PAN LINER- SECTION P2709.1 & P2709.2 FBC RES.
  
 3) P0.1: PROVIDE SHOWER VALVE COMPLIANCE INFORMATION ON
 THE PLAN- SECTIONS P2708.4 & P2713.3 FBC RES.
  
 4) P0.1: PLEASE UPDATE THE CODE COMPLIANCE DATA IN THE
 NOTES TO INDICATE THE FBC 2020 RESIDENTIAL PLUMBING
 CODE.
  
 5) P0.2 & P1.1: SHOW THE REQUIRED CLEANOUT AT THE
 JUNCTION OF THE BUILDING DRAIN AND SEWER JUNCTION-
 SECTION P3005.2.3 FBC RES.
  
 6) P0.2 & P1.1: PLEASE SHOW THE WATER SUPPLY PIPING TO
 THE MASTER BATH AND NEW LAUNDRY ROOM IN THE RISER
 DRAWING- SECTION 107.3.5.3 WPB.PLEASE SHOW THE
 LOCATIONS OF WATER HAMMER ARRESTORS AND BACKFLOW
 PREVENTERS WHERE REQUIRED- SECTION
  
 7) PROVIDE IRRIGATION PLANS OR INDICATE THE PLANS WILL
 BE SUBMITTED UNDER SEPARATE PERMIT- SECTION 105.1 &
 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2021-07-06 Cont ID  
Sent By rmcdouga Date 2021-07-06 Time 09:00 Rev Time 0.00
Received By rmcdouga Date 2021-07-06 Time 09:00 Sent To  
Notes
2021-07-06 09:22:33CONTRACTOR SUBMITTED SIGNED AND SEALED RAS 117
 CALCULATIONS PER JULIO GOMEZ ON 6/30/2021.
  
 GAF MODIFIED, NOA NO. 18-0919.12
 CLAY ROOF TILE, NOA NO. 18-0119.02
 AH160 TILE ADHESIVE, NOA NO. 17-0322.03

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2021-06-23 Cont ID  
Sent By rmcdouga Date 2021-06-23 Time 11:41 Rev Time 0.00
Received By rmcdouga Date 2021-06-23 Time 11:41 Sent To  
Notes
2021-06-23 11:41:49THE ROOFING SUBMITTALS ARE NOT APPROVED AT THIS TIME.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2021-05-05 Cont ID  
Sent By rmcdouga Date 2021-05-05 Time 13:21 Rev Time 0.00
Received By rmcdouga Date 2021-05-05 Time 08:29 Sent To  
Notes
2021-05-05 13:21:51THE ROOFING SUBMITTALS ARE NOT APPROVED AT THIS TIME.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-06-30 Cont ID  
Sent By jgomez Date 2021-06-30 Time 09:43 Rev Time 0.00
Received By jgomez Date 2021-06-30 Time 09:43 Sent To  
Notes
2021-06-30 09:44:21RAS 117 CALCULATIONS WITH ENGINEER'S EMBOSSED SEAL AND
 ORIGINAL SIGNATURE. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-06-23 Cont ID  
Sent By rmcdouga Date 2021-06-23 Time 11:41 Rev Time 0.00
Received By rmcdouga Date 2021-06-23 Time 11:41 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-04-26 Cont ID  
Sent By medwards Date 2021-04-26 Time 17:31 Rev Time 0.00
Received By medwards Date 2021-04-26 Time 17:10 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2021-06-25 Cont ID  
Sent By fmittner Date 2021-06-25 Time 16:29 Rev Time 0.00
Received By fmittner Date 2021-06-25 Time 16:27 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2021-04-23 Cont ID  
Sent By fmittner Date 2021-04-23 Time 16:15 Rev Time 0.00
Received By fmittner Date 2021-04-23 Time 16:15 Sent To  
Notes
2021-04-23 16:16:26PLEASE SUBMIT LANDSCAPE PLANS AS A SEPERATE PERMIT.