Plan Review Details - Permit 21040105
| Plan Review Stops For Permit 21040105 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2021-04-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-12 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-12 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-04-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-04-30 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-04-30 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-04-13 |
Time |
21:20 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-04-13 |
Time |
20:16 |
Sent To |
|
|
| Notes |
| 2021-04-13 21:20:02 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. VALUE LOW FOR AMOUNT OF WORK SHOWN. FBC 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2021-04-20 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-04-20 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-04-20 |
Time |
18:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-18 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-06-18 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-05-28 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-05-26 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-05-26 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-04-02 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2021-04-20 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-04-20 |
Time |
18:24 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-04-20 |
Time |
18:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-04-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-12 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-12 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-06-18 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2021-06-18 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-06-18 |
Time |
09:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-05-25 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-05-25 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-05-25 |
Time |
15:28 |
Sent To |
I |
|
| Notes |
| 2021-05-25 15:30:46 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. CLEARLY INDICATE SETBACK DIMENSIONS FROM PROPOSED | | | GENERATOR EQUIPMENT TO ALL PROPERTY LINES. PURSUANT TO | | | THE CITY OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDR), SECTION 94-305(B)(4): MECHANICAL | | | EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET INTO A | | | REQUIRED SETBACK. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
|