| 2021-09-14 07:51:03 | PLAN REVIEW BUILDING |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | 2017 NEC |
| | |
| | 2ND REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | NOTICE: WORK DESCRIPTION STATES: EXTENSION OF |
| | PATIO/PORCH AT REAR OF HOUSE. |
| | PLAN PAGE 1 (FLOOR PLAN) LABELS THIS AS AN ADDITION. |
| | PLAN PAGE 4 (ROOF VIEW) INDICATES A ROOF WILL BE |
| | INSTALLED. |
| | ADDITIONAL INFORMATION IS REQUIRED BEFORE A COMPLETE |
| | REVIEW IS PERFORMED. |
| | |
| | 1. CITY OF WPB CHPT. VALUE (NOT ADDRESSED) |
| | 109.3 BUILDING PERMIT VALUATIONS. |
| | 1A. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE |
| | OF WORK. |
| | 1B. THE PERMIT VALUATION AND PERMIT FEE MUST BE |
| | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED |
| | CONTRACTOR WOULD PROVIDE. THIS INCLUDES ALL LABOR, |
| | MATERIALS AND RENTALS OF EQUIPMENT TO PERFORM THE SCOPE |
| | OF WORK. |
| | 1C. YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY |
| | THE OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT |
| | RENTAL TO VERIFY VALUE. |
| | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE |
| | BUILDING OFFICIAL |
| | |
| | (VALUE HAS BEEN ADJUSTED TO $16,153.00) (ESTIMATED 450 |
| | SF, ICC BUILDING VALUATION IS $23,076.00. A 30% |
| | REDUCTION HAS BEEN APPLIED DUE TO OPEN STRUCTURE). |
| | |
| | 2. PROVIDE A SITE PLAN WITH A COPY OF YOUR BOUNDARY |
| | LINE SURVEY. (NOT ADDRESSED) (SEE NEW COMMENTS BELOW) |
| | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED |
| | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY |
| | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF |
| | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE |
| | SITE,... AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN |
| | ACCURATE AND INCLUDED BOUNDARY LINE SURVEY. |
| | |
| | 3. PROVIDE A COMPLETE SET OF STRUCTURAL PLANS. INCLUDE |
| | FOUNDATION, WALLS AND ROOF FRAMING. (HAND DRAWN PLANS |
| | SUBMITTED ARE INSUFFICIENT. ALL PLANS SHALL REQUIRED |
| | DEMENSIONS). |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | |
| | 4. A ROOFING PERMIT WILL BE REQUIRED. (SEE COMMENTS |
| | UNDER ROOFING REVIEW) |
| | PERMITS - 105.1 REQUIRED. |
| | |
| | 5. PROVIDE PRODUCT APPROVALS FOR ALL ROOFING SYSTEM |
| | COMPONENTS. (SEE COMMENTS UNDER ROOFING REVIEW) |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. |
| | |
| | NEW COMMENTS: |
| | |
| | 6. PROVIDE A SITE DRAINAGE PLAN. |
| | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH |
| | FBC R401.3 DRAINAGE. |
| | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND |
| | INCLUDED BOUNDARY LINE SURVEY. |
| | FBC R401.3 SITE DRAINAGE |
| | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT |
| | DOES NOT CREATE A HAZARD. |
| | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM |
| | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 |
| | INCHES WITHIN THE FIRST 10 FEET. |
| | |
| | 7. REF. ROOF PLAN 1/2 FOR THE FOLLOWING COMMENTS: |
| | 7A) PROVIDE DESIGN PRESSURES PER FIGURE R301.2(7) |
| | COMPONENT AND CLADDING PRESSURE ZONES |
| | R301.2.1.1WIND DESIGN REQUIRED. |
| | |
| | 7B) PROVIDE ROOF SHEATHING FASTENER SCHEDULE |
| | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING |
| | SCHEDULE FOR WOOD STRUCTURAL PANELS. |
| | |
| | 7C) SECTION DETAILS REFERENCE PLAN PAGE 5. PLAN PAGE 5 |
| | IS MISSING FROM THIS SUBMITTAL. |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | |
| | |