Plan Review Details - Permit 21040050
Plan Review Stops For Permit 21040050
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2021-04-20 Cont ID  
Sent By rmcphers Date 2021-04-20 Time 15:33 Rev Time 0.00
Received By rmcphers Date 2021-04-20 Time 15:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-05-07 Cont ID  
Sent By rmcphers Date 2021-05-07 Time 09:58 Rev Time 0.00
Received By rmcphers Date 2021-05-07 Time 09:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-04-20 Cont ID  
Sent By rmcphers Date 2021-04-20 Time 15:33 Rev Time 0.00
Received By rmcphers Date 2021-04-20 Time 15:33 Sent To  
Notes
2021-04-20 15:35:22CONDO REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE LOCATION AND THE TYPE OF FLOORING TO
 BE INSTALLED ON THE FLOOR PLAN.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-04-21 Cont ID  
Sent By fgiaquin Date 2021-04-21 Time 14:27 Rev Time 0.00
Received By fgiaquin Date 2021-04-15 Time 22:42 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-04-14 Cont ID  
Sent By pleduc Date 2021-04-14 Time   Rev Time 0.00
Received By pleduc Date 2021-04-14 Time 14:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-05-07 Cont ID  
Sent By rmcphers Date 2021-05-07 Time 09:59 Rev Time 0.00
Received By rmcphers Date 2021-04-26 Time 17:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2021-04-21 Time   Rev Time 0.00
Received By cdecoeur Date 2021-04-06 Time 15:14 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2021-04-20 Cont ID  
Sent By rmcphers Date 2021-04-20 Time 15:35 Rev Time 0.00
Received By rmcphers Date 2021-04-20 Time 15:35 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-04-16 Cont ID  
Sent By medwards Date 2021-04-16 Time 13:43 Rev Time 0.00
Received By medwards Date 2021-04-16 Time 12:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-05-04 Cont ID  
Sent By ccole Date 2021-05-04 Time 12:27 Rev Time 0.00
Received By ccole Date 2021-05-04 Time 11:13 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-04-21 Cont ID  
Sent By ccole Date 2021-04-21 Time 13:02 Rev Time 0.00
Received By ccole Date 2021-04-21 Time 12:29 Sent To  
Notes
2021-04-21 13:14:411ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21040050
 4/21/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE PLUMBING PLANS THAT INCLUDE A SCOPE
 OF WORK NARRATIVE FOR PLUMBING ALTERATIONS, AND A LIST
 OF REPLACED OR RELOCATED FIXTURES, APPLIANCES, FAUCETS,
 SHOWER AND TUB AND SHOWER VALVES ETC.
  
 2) PROVIDE PLUMBING RISER DRAWINGS FOR ALL SANITARY
 DRAINAGE AND VENT AND WATER PIPINGS THAT ARE BEING
 ALTERED OR EXTENDED- SECTION 107.3.5.3.1 WPB.
  
 3) INDICATE THE LOCATION OF THE NEW LAVATORIES SHOWN IN
 THE RISER DRAWING- BATH #1 OR BATH #2?- SECTION
 107.3.5.3.1 WPB.
  
 4) ADVISORIES:
  
 A) REFER TO SECTION 1002.1 FBC P: THE HORIZONTAL
 DISTANCES FROM THE CENTERLINES OF NEW OR EXTENDED
 SHOWER AND BATHTUB DRAIN OUTLETS TO THE CENTERLINES OF
 THE INLETS OF THE EXISTING TRAPS SHALL NOT EXCEED 30
 IN.
  
 B) RELOCATING PLUMBING DRAIN OUTLETS WILL REQUIRE THE
 FLOOR TO BE X-RAYED TO IN ORDER TO LOCATE REINFORCING
 STEEL OR POST STRESSED FLOOR TENDONS. IF APPLICABLE,
 PLEASE PLACE A NOTE ON THE PLANS TO VERIFY COMPLIANCE
 WILL BE MET- SECTION 107.2.1 WPB.
  
 C) NEW DRAIN PIPE PENETRATIONS OF THE EXISTING SLAB
 WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE
 AROUND THE PIPING. IF APPLICABLE PROVIDE A UL TESTED
 AND APPROVED FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN-
 SECTION 714.4.1.2 FBC B.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-04-20 Cont ID  
Sent By rmcphers Date 2021-04-20 Time 15:35 Rev Time 0.00
Received By rmcphers Date 2021-04-20 Time 15:35 Sent To  
Notes
***NONE***