| Plan Review Stops For Permit 21031585 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-05-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-05-13 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-05-13 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-04-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-04-30 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-04-30 |
Time |
09:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-04-05 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-04-05 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2021-04-05 11:15:07 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. REVISION: 21031585 | | | W. P. B. PERMIT: 20041058 | | | ADD: 650 BELVEDERE RD. | | | CONT: NUNNO BUILDERS | | | TEL: 954-961-0777 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. APRIL 05TH /2020 | | | ACTION: DENIED | | | | | | 1)SHEET C-102 THE PARKING STALL STRIPING (HAIRPIN) | | | VERSION 1 IS CORRECT, TO THE CITY OF WEST PALM BEACH | | | PARKING STANDARD THAT WAS APPROVED UNDER THE ISSUED SET | | | OF PLANS. 2017 ACCESSIBILITY CODE SECTION 502.2 VEHICLE | | | SPACES. EACH PARKING SPACE MUST BE AT LEAST 12 FEET | | | WIDE, SHALL BE MARKED TO DEFINE THE WIDTH, AND SHALL | | | HAVE AN ADJACENT ACCESS AISLE COMPLYING WITH 502.3. | | | ADVISORY 502.3.3MARKING THE METHOD AND MARKING OF COLOR | | | OF MARKING ARE NOT SPECIFIED BY THESE REQUIREMENTS BUT | | | MAY BE ADDRESSED BY STATE OR LOCAL LAWS OR REGULATIONS. | | | WEST PALM MUNI-CODE ARTICLE XV PARKING DETAIL, 94-485 | | | ILLUSTRATES WITH MEASUREMENTS FOR DOUBLE STRIPE STALL | | | PAINTING. | | | | | | 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ | | | RETIRED. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-04-06 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-04-06 |
Time |
22:04 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-04-06 |
Time |
21:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-04-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-04-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-04-06 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-05-17 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-05-17 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-05-05 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-05-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
ccarvaja |
Date |
2021-04-28 |
Time |
17:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-04-09 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-04-09 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-03-31 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2021-05-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2021-05-03 |
Time |
06:26 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-03 |
Time |
06:26 |
Sent To |
|
|
| Notes |
| 2021-05-03 06:28:35 | NO MECHANICAL WORK SHOWN ON PLANS. THE NEW COOLER AND | | | FREEZER WORK MUST HAVE A SUB-PERMIT AND REVIEW. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | 2021-04-29 10:36:04 | STAND ALONE MECH PERMIT SUBMITTED - 21041477 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2021-04-06 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2021-04-06 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2021-04-06 11:31:46 | PLAN DENIED | | | NO APPLICATION SUBMITTED HM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-05-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-05-03 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-05-03 |
Time |
16:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-04-07 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-04-07 |
Time |
07:35 |
Sent To |
|
|
| Notes |
| 2021-04-07 10:33:11 | 1ST REVIEW FBC-2017 PLUMBING | | | REVISION PERMIT- 21031585 | | | 4/7/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A1.3: THE SUBMITTED PLAN SHEET IS LACKING | | | REVISION 1 AND 2 CHANGES- 8.13.20, 2.11.21 WHICH | | | INCLUDED AMONG OTHER THINGS, THE PLUMBING FIXTURE | | | CALCULATIONS AND THE PLUMBING FIXTURE SCHEDULE. PLEASE | | | REVIEW THE APPROVED PLAN SHEET UNDER PERMIT 20041058 | | | AND PROVIDE A COMPLETELY UPDATED PLAN SHEET- SECTION | | | 107.2.1 WPB. | | | | | | 2) SHEET P1.1: DETAIL 4 FOR THE MOP SINKS IS MISLABELED | | | AS A FLOOR SINK. PLEASE SEE SECTION 1210.2.2 FBC B FOR | | | REQUIRED FLOOR AND WALL FINISHES AT THE MOP SINK. | | | TYPICALLY MOP SINKS ARE DIRECTLY CONNECTED TO THE | | | GREASE WASTE LINE HOWEVER THE PLANS SHOW FLOOR SINKS | | | BELOW THEM. THE INDIRECT CONNECTION APPEARS TO BE A | | | MISTAKE- PLEASE CLARIFY. | | | | | | 3) P1.5: PLEASE LABEL THE MOP SINK CORRECTLY. IT | | | APPEARS TO BE LABELED AS A FLOOR SINK- SECTION 107.2.1 | | | WPB. | | | | | | 4) NEW KITCHEN PLANS HAVE BEEN SUBMITTED THAT SHOW | | | EQUIPMENT WHICH WILL REQUIRE WATER SUPPLY CONNECTIONS. | | | PLEASE PROVIDE A WATER RISER DRAWING SHOWING SUPPLY | | | LINE SIZES, POINT OF CONNECTION, AND LOCATIONS OF | | | VALVES, WATER HAMMER ARRESTORS AND BACKFLOW PREVENTERS- | | | SECTION 107.3.5.3 WPB, AND SECTIONS 604.1, 604.9, & | | | 608.3 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-05-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-05-13 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-05-13 |
Time |
11:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-05-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-05-03 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-05-03 |
Time |
17:24 |
Sent To |
|
|
| Notes |
| 2021-05-03 17:34:36 | SIGNATURE REVIEW | | | PERMIT- 21031585 | | | | | | CODES IN EFFECT: | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLAN SHEETS C-000, C-002, C-100, C-101, & C-102 HAVE | | | COPIED DIGITAL SEALS AND SIGNATURES WHICH CANNOT BE | | | VERIFIED. THE ENGINEER'S STATEMENT ON THE PLAN DECLARES | | | THE PRINTED COPIES TO NOT BE CONSIDERED SIGNED AND | | | SEALED. THE PLANS SHALL BEAR THE DIGITAL SIGNATURE AND | | | SEAL OF THE ENGINEER OF RECORD- FL. STATUTE 471.025 AND | | | SECTION 61G15-23.005 FAC. | | | FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR | | | ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND | | | DOCUMENTS. | | | A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL | | | ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY | | | CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION. | | | THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE | | | A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES | | | NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.) | | | YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE | | | ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT | | | USE A THIRD PARTY. | | | YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT | | | IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE | | | AND DOCUMENT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | CCOLE@WPB | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-04-07 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-04-07 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2021-04-07 10:55:21 | SIGNATURE REVIEW | | | PERMIT- 21031585 | | | 4/7/2021 | | | | | | 1) SHEETS A2.1, A3.3, AND M1.0 ARE NOT DIGITALLY SIGNED | | | AND SEALED BY THE ARCHITECT OF RECORD- FL STATUTE | | | 481.221 AND SECTION 61G1-16.005 FLORIDA ADMINISTRATIVE | | | CODE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-05-17 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-05-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2021-05-17 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-05-03 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-05-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2021-05-03 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-04-09 |
|
|
Cont ID |
|
| Sent By |
lloui |
Date |
2021-04-09 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2021-04-09 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-04-09 14:54:39 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) STRIPING DETAIL IS INCONSISTENT WITH THE CITY'S | | | STRIPING STANDARDS FOR PARKING. PLEASE PROVIDE A | | | CORRECT DETAIL FOR STRIPING. | | | | | | 2.) CHECK PROVIDED PARKING CALCULATIONS. IT DOES NOT | | | SEEM TO MATCH THE PROVIDED PARKING IN THE SITE PLAN. | | | | | | | | | NOTES: | | | | | | SEPARATE PERMITS REQUIRED FOR: PHOTOMETRICS, | | | LANDSCAPING | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: GC (MCDONALDS @ BELMART PLAZA). | | | | | | * REFERENCE: MASTER PERMIT #18050987; REVISED MATCHING | | | LANDSCAPE PLAN 21031599. | | | |
|
|