| Plan Review Stops For Permit 21031564 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2022-04-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-04-14 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-04-14 |
Time |
07:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2022-01-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-01-18 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-18 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2022-01-18 09:38:07 | REVISION CREATING OFFICE FROM WAREHOUSE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE SHOW THE ACCESSIBLE DETAILS FOR THE RESTROOM | | | - CLEAR FLOOR SPACE FOR FIXTURES, GRAB BAR LOCATIONS, | | | TOILET PAPER HOLDER LOCATIONS, MIRROR LOCATIONS, ETC | | | PER FBC ACCESSIBILITY CHAPTER 6 | | | | | | 2) RESTROOM DOOR DOES NOT HAVE A CLEAR WIDTH OF 32" PER | | | FBC ACCESSIBILITY 404.2.3 CLEAR WIDTH. | | | DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES | | | (815 MM) MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH | | | SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF | | | THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-10-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-10-21 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-10-21 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2021-10-21 09:11:40 | REVISION CREATING OFFICE FROM WAREHOUSE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) OCCUPANCY CHANGE FROM WAREHOUSE STORAGE TO OFFICE | | | "B" - THE LANDING AT THE ADDED EXTERIOR DOORS NEEDS TO | | | BE EXTENDED (44" OUT FROM THE DOOR) TO COMPLY WITH FBC | | | 1010.1.6 | | | | | | 2) PLEASE SHOW THE HEIGHT FROM THE FINISHED FLOOR TO | | | THE BOTTOM OF THE CEILING DECK ADDED IN FRONT OF THE | | | NEW DOOR. FBC 1208.2 | | | | | | 3) PLEASE SHOW THE ACCESSIBLE DETAILS FOR THE RESTROOM | | | - CLEAR FLOOR SPACE FOR FIXTURES, GRAB BAR LOCATIONS, | | | TOILET PAPER HOLDER LOCATIONS, MIRROR LOCATIONS, ETC | | | PER FBC ACCESSIBILITY CHAPTER 6 | | | | | | 4) RESTROOM DOOR DOES NOT HAVE A CLEAR WIDTH OF 32" PER | | | FBC ACCESSIBILITY 404.2.3 CLEAR WIDTH. | | | DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES | | | (815 MM) MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH | | | SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF | | | THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-06-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-17 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-17 |
Time |
07:46 |
Sent To |
|
|
| Notes |
| 2021-06-17 09:43:58 | REVISION CREATING OFFICE FROM WAREHOUSE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE SHOW EXTERIOR WALL FRAMING ATTACHMENTS TO THE | | | EXISTING STRUCTURE TO COMPLY WITH THE WIND LOADS FBC | | | 1609 | | | 2) OCCUPANCY CHANGE FROM WAREHOUSE STORAGE TO OFFICE | | | "B" - THE LANDING AT THE ADDED EXTERIOR DOORS NEEDS TO | | | BE EXTENDED (44" OUT FROM THE DOOR) TO COMPLY WITH FBC | | | 1010.1.6 | | | 3) DOOR PRODUCT APPROVAL INSTALLATION INSTRUCTIONS ARE | | | EXPIRED - PLEASE PROVIDE THE REVISED (02/04/2019) | | | INSTALLATION INSTRUCTIONS FOR THE DOOR. FBC 107 | | | 4) PLEASE PROVIDE THE FLORIDA PRODUCT APPROVAL FRONT | | | PAGES FOR THE SHUTTERS (ONLY THE INSTALLATION | | | INSTRUCTIONS WERE PROVIDED). FBC 107 | | | 5) PLEASE SHOW THE HEIGHT FROM THE FINISHED FLOOR TO | | | THE BOTTOM OF THE CEILING DECK ADDED. FBC 1208.2 | | | 6) PLEASE SHOW THE OCCUPANCY CLASSIFICATION FOR THE | | | ADJOINING SPACE - SEPARATION NEEDS TO COMPLY WITH FBC | | | 508.1 | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-21 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-21 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2021-04-21 15:51:50 | STAIR SHOP DRAWINGS | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE SHOW WALL FRAMING DETAILS. | | | 2) PLEASE SHOW RESTROOMS TO COMPLY WITH FBC | | | ACCESSIBILITY PER CHAPTER 6 - USE DIMENSIONS TO SHOW | | | (GRAB BAR HEIGHTS, LOCATIONS AND LENGHTS FOR WATER | | | CLOSET AND SHOWER) - (DOOR WIDTHS) - (PAPER DISPENSER | | | LOCATION AND DISTANCE FROM WATER CLOSET, HEIGHT FROM | | | FLOOR) - ( FIXTURE CLEAR FLOOR SPACE) (ETC..) | | | 3) RESTROOM DOOR NEEDS A CLEAR OPENING BETWEEN ANY TRIM | | | OR STOPS OF 32" FBC 404.2.3 CLEAR WIDTH. | | | DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES | | | (815 MM) MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH | | | SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF | | | THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. | | | 4) PLEASE SHOW THE OCCUPANCY CLASSIFICATION PER FBC | | | CHAPTER 3 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2022-04-27 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-04-27 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-04-27 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2022-01-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-29 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-29 |
Time |
09:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-11-06 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-11-06 |
Time |
20:51 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-11-06 |
Time |
19:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-05-24 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-24 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-05-24 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-04-21 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-04-21 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-04-21 |
Time |
16:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2022-04-04 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-04-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-04-04 09:57:58 | FIRE COMMENT: | | | THE STREET ADDRESS NUMBER SHALL BE POSTED IN A POSITION | | | TO BE PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR | | | ROAD FRONTING THE PROPERTY AND IN CONTRAST WITH THEIR | | | BACKGROUND. NFPA 1 10.11.1 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-10-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-10-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-10-07 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-06-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-06-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-06-18 |
Time |
09:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-04-27 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-04-27 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-04-01 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-01-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-29 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-06 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-11-06 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-11-06 |
Time |
20:52 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-10-06 |
Time |
07:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-06-22 |
Time |
07:00 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-05-19 |
Time |
07:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-04-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-04-06 |
Time |
18:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2021-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-08-09 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-08-09 |
Time |
08:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-01-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-01-11 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-01-11 |
Time |
17:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-10-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-10-15 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-10-15 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-06-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-18 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-18 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2021-06-18 08:00:37 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21031564 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS FOR THE AHU. FBC EC C403.2.1 | | | | | | 2) PLEASE SHOW THE LOCATION THAT THE CONDENSING UNIT | | | WILL BE LOCATED ON THE PROPERTY. FBC 107.2.1 | | | | | | 3) PLEASE PROVIDE OUTDOOR AIR CALCULATIONS FOR THIS | | | SPACE. FBC M 403.3.1.1 AND TABLE 403.3.1.1 | | | | | | 4) PLEASE SHOW HOW THE OUTDOOR AIR WILL BE PROVIDED FOR | | | THIS SPACE. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2022-04-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-07 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-07 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2022-01-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-01-11 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-01-11 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2022-01-11 13:56:19 | 4TH REVIEW FBC-2017 PLUMBING | | | PERMIT- 21031564 (REVISION TO 20100237) | | | 1/11/22 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. THIS IS THE 4TH FAILED | | | REVIEW OF THE PLUMBING PLANS FOR THE PROJECT. NO | | | NARRATIVE WAS PROVIDED IN RESPONSE TO THE 3RD REVIEW | | | COMMENT WHICH IS LISTED BELOW. PLEASE HAVE THE | | | ARCHITECT REVIEW SECS. 212.3, 213.2 & 213.3 FBC ACC AND | | | RESPOND TO THE COMMENTS OR CONTACT ME FOR FURTHER | | | INFORMATION. | | | | | | 1) SHEETS A1 & A2: AS NOTED ON SHEET A1 UNDER CODE DATA | | | THE PRIVATE BATHROOM SHALL BE DESIGNED AND CONSTRUCTED | | | IN COMPLIANCE WITH THE FBC ACC- 2017. PLEASE ADDRESS | | | THE FOLLOWING CODE REQUIREMENTS ITEMIZED BELOW AND NOTE | | | THAT THERE ARE NO EXCEPTIONS IN THE CODES LISTED THAT | | | EXEMPTS PRIVATE OFFICES. | | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | WATER CLOSET- SECTION 604.3. | | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | LAVATORY- SECTION 606.2. (NOTE- ITEM 1 EXEMPTS THE KNEE | | | AND TOE CLEARANCES.) | | | C) TURNING SPACE DIAGRAM AND DIAMETER- SECTION 304.3. | | | D) CENTERLINE OF THE WATER CLOSET FROM THE SIDE WALL- | | | SECTION 604.2. | | | E) HEIGHT OF THE MIRROR FROM THE FINISHED FLOOR TO THE | | | REFLECTIVE SURFACE- SECTION 603.3 | | | F) WATER CLOSET GRAB BAR REINFORCEMENT LOCATIONS BASED | | | ON SECTIONS 604.5 & 609.4. | | | G) LOCATION OF THE WATER CLOSET FLUSH CONTROL- SECTION | | | 604.6. | | | H) CENTERLINE OF THE TOILET PAPER DISPENSER MEASURED | | | FROM THE FRONT OF THE WATER CLOSET- SECTION AND FIGURE | | | 604.7. | | | I) BASED ON SECTIONS 608.2 THE SHOWER COMPARTMENT SHALL | | | BE EITHER BE A TRANSFER TYPE DIMENSIONED AT 36X36 | | | INCHES, OR A STANDARD ROLL-IN TYPE WITH MINIMUM CLEAR | | | DIMENSIONS OF 30X60 INCHES. | | | K) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR EITHER | | | A TRANSFER OR ROLL-IN TYPE SHOWER- SECTIONS 608.2.1 & | | | 608.2.2.1. | | | L) SHOWER GRAB BAR REINFORCEMENT LOCATIONS BASED ON | | | SECTIONS 608.3 AND 609.4. | | | M) LOCATION OF CONTROL, FAUCET, AND SHOWER SPRAY IN THE | | | SHOWER- SECTION 608.5.1 OR 608.5.2. | | | N) HEIGHT OF THE KITCHEN SINK- SECTION 606.3. (THE PLAN | | | SHOWS 36-INCHES HOWEVER THE CODE DOES NOT PROVIDE AN | | | EXCEPTION FOR KITCHEN SINKS FROM MEETING THE MAXIMUM | | | 34-INCHES FROM THE FINISH FLOOR TO THE HIGHER OF THE | | | RIM OF THE SINK OR COUNTER SURFACE). | | | O) CLEAR FLOOR SPACE DIAGRAM AND DIMENSION FOR THE | | | KITCHEN SINK- SECTION 606.2. (ITEM 1 ALLOWS FOR A | | | PARALLEL APPROACH BECAUSE THERE IS NO COOKTOP OR | | | RANGE). | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2021-10-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-10-21 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-10-21 |
Time |
07:22 |
Sent To |
|
|
| Notes |
| 2021-10-21 09:51:38 | 3RD REVIEW FBC-2017 PLUMBING | | | PERMIT- 21031564 (REVISION TO 20100237) | | | 10/21/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A1: THE ARCHITECT'S RESPONSE LETTER TO 2ND | | | REVIEW COMMENTS STATE THE OCCUPANCY IS A "PERSONAL | | | PRIVATE OFFICE FOR THE BUILDING OWNER WHICH HAS A HDCP | | | BATHROOM IN THE BUILDING LESS THAN 100 FT. AWAY". | | | PLEASE SHOW THE LOCATION OF THE EXISTING BATHROOM ON | | | THE PLANS- SECTION 107.2.1 WPB. | | | | | | 2) SHEETS A1 & A2: AS NOTE ON SHEET A1 UNDER CODE DATA | | | THE PRIVATE BATHROOM SHALL BE DESIGNED AND CONSTRUCTED | | | IN COMPLIANCE WITH THE FBC ACC- 2017. PLEASE ADDRESS | | | THE FOLLOWING CODE REQUIREMENTS ITEMIZED BELOW AND NOTE | | | THAT THERE ARE NO EXCEPTIONS IN THE CODES LISTED THAT | | | EXEMPTS PRIVATE OFFICES. | | | | | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | WATER CLOSET- SECTION 604.3. | | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | LAVATORY- SECTION 606.2. (NOTE- ITEM 1 EXEMPTS THE KNEE | | | AND TOE CLEARANCES.) | | | C) TURNING SPACE DIAGRAM AND DIAMETER- SECTION 304.3. | | | D) CENTERLINE OF THE WATER CLOSET FROM THE SIDE WALL- | | | SECTION 604.2. | | | E) HEIGHT OF THE MIRROR FROM THE FINISHED FLOOR TO THE | | | REFLECTIVE SURFACE- SECTION 603.3 | | | F) WATER CLOSET GRAB BAR REINFORCEMENT LOCATIONS BASED | | | ON SECTIONS 604.5 & 609.4. | | | G) LOCATION OF THE WATER CLOSET FLUSH CONTROL- SECTION | | | 604.6. | | | H) CENTERLINE OF THE TOILET PAPER DISPENSER MEASURED | | | FROM THE FRONT OF THE WATER CLOSET- SECTION AND FIGURE | | | 604.7. | | | I) BASED ON SECTIONS 608.2 THE SHOWER COMPARTMENT SHALL | | | BE EITHER BE A TRANSFER TYPE DIMENSIONED AT 36X36 | | | INCHES, OR A STANDARD ROLL-IN TYPE WITH MINIMUM CLEAR | | | DIMENSIONS OF 30X60 INCHES. | | | K) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR EITHER | | | A TRANSFER OR ROLL-IN TYPE SHOWER- SECTIONS 608.2.1 & | | | 608.2.2.1. | | | L) SHOWER GRAB BAR REINFORCEMENT LOCATIONS BASED ON | | | SECTIONS 608.3 AND 609.4. | | | M) LOCATION OF CONTROL, FAUCET, AND SHOWER SPRAY IN THE | | | SHOWER- SECTION 608.5.1 OR 608.5.2. | | | N) HEIGHT OF THE KITCHEN SINK- SECTION 606.3. (THE PLAN | | | SHOWS 36-INCHES HOWEVER THE CODE DOES NOT PROVIDE AN | | | EXCEPTION FOR KITCHEN SINKS FROM MEETING THE MAXIMUM | | | 34-INCHES FROM THE FINISH FLOOR TO THE HIGHER OF THE | | | RIM OF THE SINK OR COUNTER SURFACE). | | | O) CLEAR FLOOR SPACE DIAGRAM AND DIMENSION FOR THE | | | KITCHEN SINK- SECTION 606.2. (ITEM 1 ALLOWS FOR A | | | PARALLEL APPROACH BECAUSE THERE IS NO COOKTOP OR | | | RANGE). | | | | | | 3) A2: THE PLUMBING SPECIFICATIONS INDICATE A | | | NON-THERMOSTATIC SHOWER VALVE HOWEVER A | | | BALANCED-PRESSURE, THERMOSTATIC OR BALANCED | | | PRESSURE/THERMOSTATIC VALVE SHALL BE INSTALLED- SECTION | | | 424.3 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-06-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-06-03 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-06-03 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2021-06-03 11:13:39 | 2ND REVIEW FBC-2017 PLUMBING | | | PERMIT- 21031564 (REVISION TO 20100237) | | | 6/3/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE REVISED PLAN INDICATES A CHANGE OF OCCUPANCY | | | FROM AN S TO A B OCCUPANCY- STORAGE WAREHOUSE TO | | | PRIVATE OFFICE. BASED ON THE PLAN THIS APPEARS TO BE A | | | NEW TENANT OCCUPANCY. REFER TO SECTIONS 202, AND 1010.1 | | | FBC EX AND PROVIDE PLUMBING FIXTURE CALCULATIONS FOR | | | THE B OCCUPANCY IN ACCORDANCE WITH TABLE 403.1 FBC P. | | | PLEASE NOTE THAT THE PLAN DOES NOT PROVIDE AN OCCUPANCY | | | CLASSIFICATION OR OCCUPANT LOAD, HOWEVER IT APPEARS | | | THAT AT A MINIMUM ONE ACCESSIBLE TOILET ROOM FOR BOTH | | | MALE AND FEMALE USE WOULD BE REQUIRED PER TABLE 403.1, | | | AND THE APPLICABLE SUB- SECTIONS UNDER 403. THE | | | PREVIOUS PLAN INDICATED A NEW TOILET ROOM HOWEVER THE | | | REQUIRED TOILET ROOM AND REQUIRED FIXTURES HAVE BEEN | | | ELIMINATED. PLEASE REVISE THE PLAN TO SHOW THE PLUMBING | | | PIPING AND ACCESSIBILITY DETAILS. | | | | | | 2) PLUMBING: | | | A) SANITARY AND WATER SUPPLY FLOOR PLAN DRAWINGS AND | | | RISERS. | | | B) PLUMBING FIXTURE SCHEDULE. | | | C) REQUIRED HOT WATER SOURCE AND SUPPLY FOR WASHING, | | | CULINARY PURPOSES, CLEANING ETC. | | | | | | 3) ACCESSIBILITY: | | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | WATER CLOSET- SECTION 604.3. | | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | LAVATORY- SECTION 606.2. | | | C) TURNING SPACE DIAGRAM AND DIAMETER- SECTION 304.3. | | | D) CENTERLINE OF THE WATER CLOSET FROM THE SIDE WALL- | | | SECTION 604.2. | | | E) HEIGHT OF THE WATER CLOSET SEAT FROM THE FINISHED | | | FLOOR- SECTION 604.4. | | | F) HEIGHT OF THE MIRROR FROM THE FINISHED FLOOR TO THE | | | REFLECTIVE SURFACE- SECTION 603.3 | | | G) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | | BARS FOR THE WATER CLOSET- SECTION 604.5 & 609.4, | | | FIGURES 604. | | | H) LOCATION OF THE WATER CLOSET FLUSH CONTROL- SECTION | | | 604.6. | | | I) CENTERLINE OF THE TOILET PAPER DISPENSER MEASURED | | | FROM THE FRONT OF THE WATER CLOSET- SECTION AND FIGURE | | | 604.7. | | | K) KNEE AND TOE CLEARANCES FOR THE LAVATORY- SECTION | | | 606.2. | | | | | | 3) THE SUBMITTED ENERGY EFFICIENCY FORM R405 IS USED | | | FOR RESIDENTIAL OCCUPANCIES. PLEASE PROVIDE THE | | | APPLICABLE COMPLIANCE DOCUMENT- SECTION C101.5.1 FBC | | | EC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-04-22 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-04-22 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2021-04-22 10:57:55 | 1ST REVIEW FBC-2017 PLUMBING | | | PERMIT- 21031564 (REVISION TO 20100237) | | | 4/21/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE SUBMITTED REVISION APPLICATION INDICATES | | | "ADDITIONAL PLUMBING" HOWEVER NO PLUMBING PLANS AND | | | DETAILS HAVE BEEN SUBMITTED. IN ACCORDANCE WITH | | | SECTIONS 107.2.1 & 107.3.5.3.1.3 WPB PLEASE PROVIDE | | | COMPLETE PLUMBING DEMOLITION AND RE-WORK PLANS | | | INCLUDING: | | | A) MINIMUM FIXTURE CALCULATIONS PER TABLE 403.1 FBC P. | | | PROVIDE A SCHEDULE INDICATING THE NUMBER OF REQUIRED | | | AND PROVIDED PLUMBING FIXTURES BASED ON THE OCCUPANT | | | LOAD AND OCCUPANCY CLASSIFICATION OF THE SPACE. | | | A) PLUMBING FLOOR PLAN SHOWING LOCATIONS OF ALL, NEW OR | | | REPLACED PLUMBING FIXTURES AND PIPING. | | | B) SANITARY DRAINAGE AND WATER RISER DRAWINGS. | | | C) PLUMBING FIXTURE AND DEVICE SCHEDULES. | | | D) WATER HEATER EQUIPMENT SCHEDULE AND SPECS. | | | E) PLUMBING PIPING SPECIFICATIONS. | | | F) SLAB REPAIR DETAIL. | | | | | | 2) REFER TO SECTION 1003.3.1 FBC P. A NEW KITCHEN IS | | | SHOWN ON THE PLAN WHICH MAY REQUIRE INSTALLATION OF A | | | GREASE INTERCEPTOR TO RECEIVE THE DRAINAGE FROM | | | PLUMBING FIXTURES DISCHARGING GREASE LADED WASTE. | | | PLEASE PROVIDE A SCOPE OF WORK FOR COOKING OPERATIONS | | | IN THE KITCHEN, A KITCHEN EQUIPMENT PLAN, AND | | | CORRELATING EQUIPMENT SCHEDULE. | | | | | | 2) MISSING ACCESSIBILITY DETAILS PER FBC ACC- | | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | WATER CLOSETS- SECTION 604.3. | | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | LAVATORIES- SECTION 606.2. | | | C) TURNING SPACE DIAMETERS- SECTION 304.3. | | | D) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE | | | WALLS- SECTION 604.2. | | | E) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED | | | FLOORS- SECTION 604.4. | | | F) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO | | | THE REFLECTIVE SURFACES- SECTION 603.3 | | | G) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | | BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4, | | | FIGURES 604. | | | H) LOCATION OF THE WATER CLOSET FLUSH CONTROLS - | | | SECTION 604.6. | | | I) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED | | | FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND | | | FIGURE 604.7. | | | K) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION | | | 606.2 | | | | | | SHOWER- | | | L) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | SHOWER- SECTIONS 608.2.1/608.2.2 | | | M) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | | BARS FOR THE ACCESSIBLE SHOWER- SECTIONS | | | 608.3.1/608.3.2. | | | N) LOCATION OF CONTROL, FAUCET, AND SHOWER SPRAY IN THE | | | SHOWER- SECTION 608.5.1/608.5.2. | | | 0) SHOWER SPRAY UNIT SPECIFICATIONS PER SECTION 608.6. | | | P) LOCATION AND INSTALLATION DIMENSIONS FOR AN | | | ACCESSIBLE SHOWER SEAT (IF INSTALLED)- SECTIONS 610.3. | | | | | | DRINKING FOUNTAINS (WHERE REQUIRED AND INSTALLED)- | | | Q) REFER TO SECTIONS 306, 307, AND 602 FBC ACC AND | | | PROVIDE DRINKING FOUNTAIN INSTALLATION DETAILS AND | | | ELEVATION VIEWS SHOWING KNEE AND TOE CLEARANCES, SPOUT | | | HEIGHTS, AND SPOUT LOCATIONS. SHOW THE REQUIRED 30 X 48 | | | IN. CLEAR FLOOR SPACE FOR A FORWARD WHEELCHAIR APPROACH | | | TO THE FOUNTAIN- SECTION 602.2 FBC ACC, AND SHOW HOW | | | THE LOCATIONS OF THE FOUNTAINS WILL BE IN COMPLIANCE | | | WITH SECTION 307.2 PROTRUSION LIMITS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2022-04-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-04-14 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-04-14 |
Time |
07:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-01-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-01-18 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-18 |
Time |
09:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-10-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-10-06 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-10-06 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2021-10-06 16:09:17 | PLANS SENT TO STORAGE JLEAHY |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-06-17 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-06-17 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-06-17 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-04-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-21 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-21 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|