| Plan Review Stops For Permit 21031478 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2021-04-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-02 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-02 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2021-04-02 16:07:43 | RESURFACE POOL, NEW DECK AND EQUIPMENT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2021-08-11 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-08-11 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-08-11 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2021-08-09 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-08-09 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-08-09 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2021-08-09 10:08:12 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND SEALED | | | BY A LICENSED DESIGN PROFESSIONAL OR SIGNED BY THE | | | ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | | 471.025; WPB FBC 107.2.1, 107.3.5 | | | 2.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-08-02 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-08-02 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-08-02 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2021-08-02 10:28:21 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND SEALED | | | BY A LICENSED DESIGN PROFESSIONAL OR SIGNED BY THE | | | ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | | 471.025; WPB FBC 107.2.1, 107.3.5 | | | 2.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-04-05 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-04-05 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-04-05 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2021-04-05 12:52:35 | NO ELECTRICAL INFORMATION ON EXISITING OR NEW | | | EQUIPMENT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-08-09 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-08-09 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-08-04 |
Time |
07:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-08-02 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-08-02 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-07-29 |
Time |
08:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-22 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-01 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-04-02 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-04-02 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-04-02 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2021-04-02 10:14:10 | 04/02/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2021-04-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-02 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-02 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-04-21 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-04-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2021-04-21 |
Time |
|
Sent To |
I |
|
| Notes |
|
|