| 2021-05-07 08:26:32 | PLAN REVIEW / BUILDING / GENERATOR | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | 1) PROVIDE STRUCTURAL DETAIL OF GENERATOR PAD. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 4) STRUCTURAL PAD DETAIL SHALL BE SIGNED BY DESIGNER. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | | | | 2) R303.5.1 INTAKE OPENINGS: MECHANICAL AND GRAVITY | | | OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS | | | THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS | | | CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS, | | | STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-05-07 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-05-07 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-05-07 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2021-07-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-07-26 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-07-26 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2021-07-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-07-23 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-07-23 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2021-07-23 14:01:29 | 3RD REVIEW FBC-2020 RES. FUEL GAS | | | PERMIT- 21031167 | | | 7/23/2021 | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE REVISED DRAWING IS INDICATING A 795,000 TOTAL | | | BTU LOAD AT A TOTAL DEVELOPED LENGTH OF 49 FT. FROM | | | METER TO MOST REMOTE OUTLET. BASED ON THE SUBMITTED | | | SIZING TABLE 402.4(2) FBC FG, THE 1-1/4 IN. SCHED. 40 | | | PIPE IS UNDERSIZED AND WILL PROVIDE A MAXIMUM 583,000 | | | BTUS. A MINIMUM 1-1/2 IN. PIPE IS REQUIRED- SECTIONS- | | | G2412.4 & G2413.4.1 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-06-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-06-30 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-06-30 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2021-06-30 07:50:10 | 2ND REVIEW FBC-2020 RES. FUEL GAS | | | PERMIT- 21031167 | | | 6/30/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. COMMENTS NOT ADDRESSED | | | FROM THE 1ST REVIEW ARE LISTED BELOW. | | | | | | 1B) DELIVERY PRESSURE AT THE METER. (NOT PROVIDED). | | | | | | 1K) PIPE SIZING TABLES. (LOW PRESSURE SCHED-40 | | | GALVANIZED TABLE NOT PROVIDED). | | | | | | PLEASE NOTE TABLE 402.4(21) WAS SUBMITTED FOR LOW | | | PRESSURE PE PIPING. THE DRAWING SHOWS A NEW TEE AT THE | | | METER WHICH APPEARS TO INDICATE A 3/4- INCH MAIN PIPE. | | | USING THE RELATIVE TABLE FOR LOW PRESSURE SCHED-40 | | | GALVANIZED -TABLE G2413.4(1) [402.4(2) , THE 3/4- INCH | | | INCH MAIN PIPE AT THE METER IS UNDERSIZED FOR THE | | | INCREASED TOTAL BTU LOAD OF 795,000 AT A TOTAL | | | DEVELOPED LENGTH OF 49 FT- SECTIONS G2413.1 & G2413.4.1 | | | FBC RES, | | | | | | 3) SURVEY: PLEASE INDICATE THE REQUIRED 10 FT. | | | CLEARANCE FOR THE GENERATOR EXHAUST TO WINDOW AND DOOR | | | OPENINGS INTO THE BUILDING- SECTION R303.5.1 FBC RES. | | | NEW COMMENT. | | | 1) THE PRINTED NAME, SIGNATURE AND LICENSE NUMBER OF | | | THE CONTRACTOR OR QUALIFIER SHALL BE PROVIDED ON THE | | | GAS RISER DRAWING- SECTION 107.2.1 WPB, AND FLORIDA | | | STATUTES 471.003(2)(H) & 471.025. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-05-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-05-07 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-05-07 |
Time |
07:17 |
Sent To |
|
|
| Notes |
| 2021-05-07 07:30:36 | 1ST REVIEW FBC-2020 RES. FUEL GAS | | | PERMIT- 21031167 | | | 5/7/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A COMPLETE GAS RISER DRAWING FOR THE | | | GENERATOR THAT INCLUDES ALL NEW AND EXISTING GAS PIPING | | | AND APPLIANCES AT THE RESIDENCE- SECTION G2412.3 & | | | G2412.4 FBC RES. REFER TO FBC RES. CHAPTER 24 FUEL GAS- | | | THE RISER SHALL INDICATE: | | | A) TYPE OF GAS- NATURAL OR LP. | | | B) DELIVERY PRESSURE AT THE METER. | | | C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. | | | D) TYPES AND SIZES OF PIPING. | | | E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER | | | TO THE MOST REMOTE APPLIANCE OUTLET. | | | F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. | | | G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE | | | UNIONS. | | | H) OUTLET PRESSURES AT REGULATORS. | | | I) LOCATIONS AND TYPES OF PIPE SLEEVES. | | | K) PIPE SIZING TABLES. | | | | | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | REGULATORS MARKED UP OR HIGHLIGHTED TO SHOW THE | | | SELECTED MODEL, INPUT AND OUT PRESSURES AND PIPE SIZES, | | | AND ORIFICE SIZES- G2421.1 & G2421.2 FBC RES. | | | | | | 3) SURVEY: PLEASE INDICATE THE REQUIRED 10 FT. | | | CLEARANCE FOR THE GENERATOR EXHAUST TO WINDOW AND DOOR | | | OPENINGS INTO THE BUILDING- SECTION R303.5.1 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-07-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-07-15 |
Time |
10:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-07-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-03 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-06-21 |
Time |
06:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-05-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-28 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-26 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-03-24 |
|
|
Cont ID |
|
| Sent By |
ccarvaja |
Date |
2021-03-24 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
ccarvaja |
Date |
2021-03-23 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2021-07-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-07-23 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-07-23 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-06-30 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-06-30 |
Time |
07:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2021-05-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-05-07 |
Time |
07:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-05-07 |
Time |
07:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
N |
Date |
2021-07-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-07-23 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-07-23 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-07-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-07-03 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-07-03 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-05-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-07 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-07 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2021-05-07 08:27:26 | STRUCTURAL PAD DETAIL SHALL BE SIGNED BY DESIGNER. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-05-26 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2021-05-26 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2021-05-26 |
Time |
|
Sent To |
I |
|
| Notes |
|
|