Plan Review Details - Permit 21031154
| Plan Review Stops For Permit 21031154 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-06-23 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-06-23 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-05-04 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-05-04 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2021-05-04 14:06:48 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT REQUIRED COMPONENT AND CLADDING DESIGN | | | PRESSURES FOR THE OPENINGS THAT HAVE BEEN PREPARED BY A | | | FLORIDA LICENSED DESIGN PROFESSIONAL. THE DOCUMENTS ARE | | | REQUIRED TO BE DIGITALLY SIGNED BY THE DESIGN | | | PROFESSIONAL IF SUBMITTED ELECTRONICALLY AND THE DESIGN | | | PROFESSIONAL'S ORIGINAL HANDWRITTEN SIGNATURE IF PAPER | | | DOCUMENTS ARE SUBMITTED. FS 471 & FAC 61G15 /FS 481 & | | | FAC 61G1 | | | | | | 2) ONE OR BOTH OF THESE CHURCH BUILDINGS MAY BE RISK | | | CATEGORY III. THIS WILL NEED TO BE DETERMINED BY THE | | | DESIGN PROFESSIONAL AND REFLECTED IN THE COMPONENT AND | | | CLADDING PRESSURES. FBC BUILDING 1604.5 | | | | | | 3) SOME OF THESE DOORS MAY BE REQUIRED EXIT DOORS THAT | | | ARE REQUIRED TO OPEN IN THE DIRECTION OF EXIT TRAVEL | | | AND HAVE PANIC HARDWARE. SPECIFY THE SWING AND HARDWARE | | | ON THE EXISTING DOORS AND THE REPLACEMENT DOORS. THEY | | | CAN NOT BE ANY LESS RESTRICTIVE THAN THE EXISTING. FBC | | | EXISTING BUILDING 704.1 | | | | | | 4) HI-LIGHT OR CIRCLE THE SPECIFIC DOOR SIZES, GLASS | | | TYPE, DESIGN PRESSURE AND OTHER ITEMS THAT APPLY TO THE | | | DOORS THAT WILL BE INSTALLED. FBC AMENDMENTS 107.2.1 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-06-23 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-06-09 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-05-04 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-23 |
Time |
08:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-06-23 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-06-23 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-05-04 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-05-04 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2021-05-04 14:58:51 | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | | THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON THEM. | | | YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND | | | SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC | | | PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE | | | CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT | | | TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S ORIGINAL | | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | | SIGNATURE ARE ACCEPTABLE. FS 487 & 61G1 OR FS 471 & | | | 61G15 |
|
|
|