Plan Review Details - Permit 21031135
Plan Review Stops For Permit 21031135
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2021-05-04 Cont ID  
Sent By rmcdouga Date 2021-05-04 Time 08:44 Rev Time 0.00
Received By rmcdouga Date 2021-05-04 Time 08:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-04-06 Cont ID  
Sent By rmcdouga Date 2021-04-06 Time 15:37 Rev Time 0.00
Received By rmcdouga Date 2021-04-06 Time 14:58 Sent To  
Notes
2021-04-06 15:15:38PROVISO
 FBC-R314.3.1 ALTERATIONS, REPAIRS AND ADDITIONS. WHEN
 ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT
 OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR
 CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL DWELLING
 UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED AS
 REQUIRED FOR NEW DWELLINGS.
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-05-05 Cont ID  
Sent By jleahy Date 2021-05-05 Time 08:42 Rev Time 0.00
Received By jleahy Date 2021-05-05 Time 08:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-04-26 Cont ID  
Sent By jleahy Date 2021-04-26 Time 09:06 Rev Time 0.00
Received By jleahy Date 2021-04-26 Time 08:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-03-30 Cont ID  
Sent By jleahy Date 2021-03-30 Time 11:03 Rev Time 0.00
Received By jleahy Date 2021-03-30 Time 11:01 Sent To  
Notes
2021-03-30 11:06:18ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 KITCHEN COUNTER OUTLETS DO NOT LOOK LIKE THEY WILL MEET
 THE SPACING REQUIREMENTS IN 210.52.
  
 THE WALL SPACING REQUIREMENTS FOR KITCHEN COUNTER SPACE
 STATE THAT RECEPTACLE OUTLETS SHALL BE INSTALLED SO
 THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24
 INCHES MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET
 IN THAT SPACE. THE PLAN PROVIDED DOES NOT MEET THIS
 CODE IN SOME AREAS. PROVIDE CORRECTION. NEC
 210.52(C)(1)

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-05-05 Cont ID  
Sent By jleahy Date 2021-05-05 Time 08:47 Rev Time 0.00
Received By jleahy Date 2021-04-28 Time 11:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-04-26 Cont ID  
Sent By jleahy Date 2021-04-26 Time 09:07 Rev Time 0.00
Received By jleahy Date 2021-04-20 Time 13:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-04-07 Cont ID  
Sent By lcrespo Date 2021-04-07 Time 09:49 Rev Time 0.00
Received By lcrespo Date 2021-03-24 Time 14:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-04-22 Cont ID  
Sent By abelisle Date 2021-04-22 Time 21:30 Rev Time 0.00
Received By abelisle Date 2021-04-22 Time 21:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-04-06 Cont ID  
Sent By abelisle Date 2021-04-06 Time 18:54 Rev Time 0.00
Received By abelisle Date 2021-04-06 Time 18:42 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-05-07 Cont ID  
Sent By jleahy Date 2021-05-07 Time 13:12 Rev Time 0.00
Received By jleahy Date 2021-05-07 Time 13:12 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2021-05-05 Cont ID  
Sent By jleahy Date 2021-05-05 Time 08:45 Rev Time 0.00
Received By jleahy Date 2021-05-05 Time 08:45 Sent To  
Notes
2021-05-05 08:47:09ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) PLAN IS NOT DIGITALLY SIGNED BY THE DESIGNER OF
 RECORD
  
 PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN
 PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. FS
 471.003(2)(H); 471.025; FBC 107.2.1
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-04-26 Cont ID  
Sent By jleahy Date 2021-04-26 Time 09:06 Rev Time 0.00
Received By jleahy Date 2021-04-26 Time 09:06 Sent To  
Notes
2021-04-26 09:07:50ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) PLAN IS NOT DIGITALLY SIGNED BY THE DESIGNER OF
 RECORD
  
 PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN
 PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. FS
 471.003(2)(H); 471.025; FBC 107.2.1
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-03-25 Cont ID  
Sent By medwards Date 2021-03-25 Time 05:59 Rev Time 0.00
Received By medwards Date 2021-03-25 Time 05:57 Sent To  
Notes
***NONE***