Plan Review Details - Permit 21031086
Plan Review Stops For Permit 21031086
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-03-24 Cont ID  
Sent By rmcdouga Date 2021-03-24 Time 10:54 Rev Time 0.00
Received By rmcdouga Date 2021-03-24 Time 10:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-05-03 Cont ID  
Sent By cthroop Date 2021-05-03 Time 11:11 Rev Time 0.00
Received By cthroop Date 2021-05-03 Time 11:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2021-03-25 Cont ID  
Sent By cthroop Date 2021-03-25 Time 14:49 Rev Time 0.00
Received By cthroop Date 2021-03-25 Time 14:02 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-05-03 Cont ID  
Sent By cthroop Date 2021-05-03 Time 11:11 Rev Time 0.00
Received By cthroop Date 2021-05-03 Time 11:10 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-04-15 Cont ID  
Sent By cthroop Date 2021-04-15 Time 16:45 Rev Time 0.00
Received By cthroop Date 2021-04-15 Time 15:58 Sent To  
Notes
2021-04-15 16:59:49PLAN REVIEW GENERATOR / FUEL GAS
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1)PROVIDE A GAS ISOMETRIC DRAWING:
 1A) PROVIDE AN ISO DRAWING SHOWING THE ENTIRE SYSTEM
 INCLUDING ALL BRANCH PIPES FROM THE METER TO THE MOST
 REMOTE OUTLET. THE BTUH LOAD OF EACH EXISTING APPLIANCE
 AND THE LOCATIONS OF REGULATORS SHALL BE INDICATED ON
 THE DRAWING- SECTIONS G2412.3 & G2412.4 FBC RES.
 1B) PROVIDE THE TOTAL DEVELOPED LENGTH OF THE SYSTEM
 FROM THE METER TO THE MOST REMOTE OUTLET, AND BRANCH
 LENGTH SIZES- SECTIONS G2413.4.1, G2413.4.2 &
 G2413.4.3. PROVIDED
 1B) PROVIDE DELIVERY PRESSURE TO THE GENERATOR FROM THE
 OUTLET OF THE REGULATOR- SECTION G2421.1
 1C) PROVIDE THE BTUH LOAD OF THE GENERATOR. G2413.2 FBC
 RES.
 1D) ) PROVIDE THE PIPE SIZING TABLES FOR EACH TYPE OF
 PIPING INSTALLED. G2413.2 FBC RES.
  
 REF: PLAN PAGE E1 FOR THE FOLLOWING:
  
 2) THE GENERATOR SHALL NOT BE CLOSER THAN 10 FEET TO
 ANY BUILDING OPENING.
 R303.5.1 INTAKE OPENINGS: MECHANICAL AND GRAVITY
 OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS
 THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS
 CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS,
 STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-05-03 Cont ID  
Sent By cthroop Date 2021-05-03 Time 11:11 Rev Time 0.00
Received By cthroop Date 2021-04-20 Time 11:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-04-15 Cont ID  
Sent By cthroop Date 2021-04-15 Time 16:59 Rev Time 0.00
Received By cthroop Date 2021-03-22 Time 14:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2021-05-03 Cont ID  
Sent By cthroop Date 2021-05-03 Time 11:10 Rev Time 0.00
Received By cthroop Date 2021-05-03 Time 11:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-03-24 Cont ID  
Sent By rmcdouga Date 2021-03-24 Time 10:55 Rev Time 0.00
Received By rmcdouga Date 2021-03-24 Time 10:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-05-03 Cont ID  
Sent By cthroop Date 2021-05-03 Time 11:11 Rev Time 0.00
Received By cthroop Date 2021-05-03 Time 11:11 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-04-15 Cont ID  
Sent By cthroop Date 2021-04-15 Time 16:41 Rev Time 0.00
Received By cthroop Date 2021-04-15 Time 15:58 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-04-14 Cont ID  
Sent By awooten Date 2021-04-14 Time   Rev Time  
Received By awooten Date 2021-04-14 Time   Sent To  
Notes
***NONE***