Plan Review Details - Permit 21030991
Plan Review Stops For Permit 21030991
Review Stop AD ADDRESSING
Rev No 5 Status P Date 2022-08-01 Cont ID  
Sent By cpuell Date 2022-08-01 Time 08:06 Rev Time 0.00
Received By cpuell Date 2022-08-01 Time 08:06 Sent To  
Notes
2022-08-01 08:07:04HALF ADDRESS READDRESSED TO 250 MALVERNE RD

Review Stop AD ADDRESSING
Rev No 4 Status F Date 2022-07-19 Cont ID  
Sent By cpuell Date 2022-07-19 Time 15:44 Rev Time 0.00
Received By cpuell Date 2022-07-19 Time 15:44 Sent To  
Notes
2022-07-19 15:45:46SPOKE WITH OWNER PROPOSED THE ADDRESS OF 250 MALVERNE
 RD, STATED THEY WOULD GET BACK TO ME, AT THIS TIME HALF
 ADDRESS ISSUES HAVE NOT BEEN ADDRESSED. PLEASE CONTACT
 [email protected] OR CALL 561-805-6659

Review Stop AD ADDRESSING
Rev No 3 Status F Date 2022-05-07 Cont ID  
Sent By cpuell Date 2022-05-07 Time 09:48 Rev Time 0.00
Received By cpuell Date 2022-05-07 Time 09:48 Sent To  
Notes
2022-05-07 09:48:23PREVIOUS COMMENTS NOT ADDRESSED

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2022-03-31 Cont ID  
Sent By cpuell Date 2022-03-31 Time 12:56 Rev Time 0.00
Received By cpuell Date 2022-03-31 Time 12:56 Sent To  
Notes
2022-03-31 12:57:10PREVIOUS COMMENTS NOT ADDRESSED

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2021-03-22 Cont ID  
Sent By cpuell Date 2021-03-22 Time 08:04 Rev Time 0.00
Received By cpuell Date 2021-03-22 Time 08:04 Sent To  
Notes
2021-03-22 08:05:09HALF ADDRESS VIOLATION ON PROPERTY THE EAST BLDG NEEDS
 TO BE READDRESSED. PLEASE HAVE OWNER CONTACT
 [email protected] TO DISCUSS ADDRESSING OPTIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-08-12 Cont ID  
Sent By rmcdouga Date 2022-08-12 Time 13:36 Rev Time 0.00
Received By rmcdouga Date 2022-08-12 Time 13:36 Sent To  
Notes
2022-08-12 13:50:32THE GENERATOR EXHAUST IS REQUIRED TO BE AT LEAST 10
 FEET FROM ANY OPENINGS INTO A BUILDING. FBC-R303.5.1

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-07-08 Cont ID  
Sent By pvalenti Date 2022-07-08 Time 08:32 Rev Time 0.00
Received By pvalenti Date 2022-07-08 Time 06:37 Sent To  
Notes
2022-07-08 08:34:17PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1) OK, MODEL # RXSW200A3, 22KW, 445 POUNDS AS PER
 SUBMITTED MANUAL.
  
 2) NOT RESOLVED. PROVIDE DETAILS OF THE EXISTING
 GENERATOR SLAB AND SPECIFY THE NUMBER, TYPE AND SIZE OF
 THE FASTENERS THAT WILL BE USED TO ANCHOR THE GENERATOR
 TO THE SLAB TO RESIST WIND LOADS. FBC AMENDMENTS
 107.2.1
  
 3) NOT RESOLVED. SHOW THAT THE GENERATOR IS LOCATED 5
 FEET FROM THE WALLS OF ANY BUILDING. FBC? FUEL GAS
 616.1 POWERED EQUIPMENT. PERMANENTLY INSTALLED
 EQUIPMENT POWERED BY INTERNAL COMBUSTION ENGINES AND
 TURBINES SHALL BE INSTALLED IN ACCORDANCE WITH THE
 MANUFACTURER?S INSTRUCTIONS AND NFPA 37. STATIONARY
 ENGINE GENERATOR ASSEMBLIES SHALL MEET THE REQUIREMENTS
 OF UL 2200.
  
 4) NOT RESOLVED. SHOW THAT THE GENERATOR EXHAUST IS AT
 LEAST 10 FEET FROM ANY OPENINGS INTO A BUILDING.
 FBC?R303.5.1 INTAKE OPENINGS. MECHANICAL AND GRAVITY
 OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS
 THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS
 CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS,
 STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS.
  
 5) NOT RESOLVED. THE VALUE FOR THIS PROJECT OF $2350.00
 APPEARS TO BE LOW. FOR PERMITTING PURPOSES THE
 VALUATION IS REQUIRED TO INCLUDE THE COSTS OF THE
 LABOR, MATERIALS, OVERHEAD AND PROFIT AS WOULD BE
 CHARGED BY A CONTRACTOR. PROVIDE A COMPLETE SCOPE OF
 WORK WITH A COST BREAKDOWN. FBC AMENDMENTS 109.3
 BUILDING PERMIT VALUATION. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC,
 PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE
 WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHEDDATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES
 (MARSHALL?SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 6) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE?SUBMITTAL FORM.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-04-25 Cont ID  
Sent By pvalenti Date 2022-04-25 Time 17:25 Rev Time 0.00
Received By rmcdouga Date 2022-04-25 Time 17:25 Sent To  
Notes
2022-04-25 17:18:03PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) NOT RESOLVED. [SUBMIT DETAILED SPECIFICATIONS FOR
 THE GENERATOR MODEL THAT WILL BE INSTALLED.] SUBMIT THE
 MANUFACTURER'S SPECIFICATIONS FOR THE NEW GENERATOR.
 SPECIFY THE MODEL NUMBER AND KW OF THE NEW GENERATOR.
 FBC AMENDMENTS 107.2.1
  
 2) NOT RESOLVED. PROVIDE DETAILS OF THE EXISTING
 GENERATOR SLAB AND SPECIFY THE NUMBER, TYPE AND SIZE OF
 THE FASTENERS THAT WILL BE USED TO ANCHOR THE GENERATOR
 TO THE SLAB TO RESIST WIND LOADS. FBC AMENDMENTS
 107.2.1
  
 3) NOT RESOLVED. SHOW THAT THE GENERATOR IS LOCATED 5
 FEET FROM THE WALLS OF ANY BUILDING. FBC- FUEL GAS
 616.1 POWERED EQUIPMENT. PERMANENTLY INSTALLED
 EQUIPMENT POWERED BY INTERNAL COMBUSTION ENGINES AND
 TURBINES SHALL BE INSTALLED IN ACCORDANCE WITH THE
 MANUFACTURER'S INSTRUCTIONS AND NFPA 37. STATIONARY
 ENGINE GENERATOR ASSEMBLIES SHALL MEET THE REQUIREMENTS
 OF UL 2200.
  
 4) NOT RESOLVED. SHOW THAT THE GENERATOR EXHAUST IS AT
 LEAST 10 FEET FROM ANY OPENINGS INTO A BUILDING.
 FBC-R303.5.1 INTAKE OPENINGS. MECHANICAL AND GRAVITY
 OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS
 THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR NOXIOUS
 CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS,
 STREETS, ALLEYS, PARKING LOTS AND LOADING DOCKS.
  
 5) NOT RESOLVED. THE VALUE FOR THIS PROJECT OF $2350.00
 APPEARS TO BE LOW. FOR PERMITTING PURPOSES THE
 VALUATION IS REQUIRED TO INCLUDE THE COSTS OF THE
 LABOR, MATERIALS, OVERHEAD AND PROFIT AS WOULD BE
 CHARGED BY A CONTRACTOR. PROVIDE A COMPLETE SCOPE OF
 WORK WITH A COST BREAKDOWN. FBC AMENDMENTS 109.3
 BUILDING PERMIT VALUATION. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC,
 PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE
 WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 6) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-04-07 Cont ID  
Sent By rmcdouga Date 2021-04-07 Time 09:25 Rev Time 0.00
Received By rmcdouga Date 2021-04-07 Time 09:25 Sent To  
Notes
2021-04-07 10:08:57PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT THE MANUFACTURER'S SPECIFICATIONS FOR THE NEW
 GENERATOR. SPECIFY THE MODEL NUMBER AND KW OF THE NEW
 GENERATOR. FBC AMENDMENTS 107.2.1
  
 2) PROVIDE DETAILS OF THE EXISTING GENERATOR SLAB AND
 SPECIFY THE NUMBER, TYPE AND SIZE OF THE FASTENERS THAT
 WILL BE USED TO ANCHOR THE GENERATOR TO THE SLAB TO
 RESIST WIND LOADS. FBC AMENDMENTS 107.2.1
  
 3) SHOW THAT THE GENERATOR IS LOCATED 5 FEET FROM THE
 WALLS OF ANY BUILDING. FBC- FUEL GAS 616.1 POWERED
 EQUIPMENT. PERMANENTLY INSTALLED EQUIPMENT POWERED BY
 INTERNAL COMBUSTION ENGINES AND TURBINES SHALL BE
 INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S
 INSTRUCTIONS AND NFPA 37. STATIONARY ENGINE GENERATOR
 ASSEMBLIES SHALL MEET THE REQUIREMENTS OF UL 2200.
  
 4) SHOW THAT THE GENERATOR EXHAUST IS AT LEAST 10 FEET
 FROM ANY OPENINGS INTO A BUILDING. FBC-R303.5.1 INTAKE
 OPENINGS. MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE
 OPENINGS SHALL BE LOCATED NOT LESS THAN 10 FEET (3048
 MM) FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS
 VENTS, CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS,
 PARKING LOTS AND LOADING DOCKS.
  
 5) THE VALUE FOR THIS PROJECT OF $2350.00 APPEARS TO BE
 LOW. FOR PERMITTING PURPOSES THE VALUATION IS REQUIRED
 TO INCLUDE THE COSTS OF THE LABOR, MATERIALS, OVERHEAD
 AND PROFIT AS WOULD BE CHARGED BY A CONTRACTOR. PROVIDE
 A COMPLETE SCOPE OF WORK WITH A COST BREAKDOWN. FBC
 AMENDMENTS 109.3 BUILDING PERMIT VALUATION. FOR
 PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS
 SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 6) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2022-08-17 Cont ID  
Sent By jleahy Date 2022-08-17 Time 10:15 Rev Time 0.00
Received By jleahy Date 2022-08-17 Time 10:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2022-07-30 Cont ID  
Sent By jleahy Date 2022-07-30 Time 15:23 Rev Time 0.00
Received By jleahy Date 2022-07-30 Time 15:17 Sent To  
Notes
2022-07-30 15:24:207K MAY COVER THE COST OF THE EQUIPMENT BUT NOT BOTH
 MATERIAL AND LABOR..

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2022-05-15 Cont ID  
Sent By jleahy Date 2022-05-15 Time 15:37 Rev Time 0.00
Received By jleahy Date 2022-05-15 Time 15:30 Sent To  
Notes
2022-05-15 15:39:05FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 VALUE OF THE WORK IS NOT IN CONFORMANCE WITH INDUSTRY
 STANDARDS. PLEASE SUBMIT A COST BREAKDOWN OF ALL
 MATERIALS AND LABOR.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2022-04-19 Cont ID  
Sent By mpeterso Date 2022-04-19 Time 11:58 Rev Time 0.00
Received By mpeterso Date 2022-04-19 Time 11:54 Sent To  
Notes
2022-04-19 11:58:11ELECTRIC REVIEW FAILED
  
 1 NO ELECTRIC PLANS INCLUDED FOR REVIEW. PLEASE SUBMIT
 ALL DRAWINGS, CALCULATIONS AND SPECIFICATIONS AS
 REQUIRED . FBC 107.2 AND NEC 215.5
  
 2) VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE A BREAKDOWN OF ALL MATERIALS AND LABOR,
 OR, AT YOUR DISCRETION, PROVIDE A SIGNED CONTRACTOR OR
 PROVIDE A REASONABLE VALUE. WPB F.B.C. 109.3
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-03-25 Cont ID  
Sent By cthroop Date 2021-03-25 Time 14:52 Rev Time 0.00
Received By cthroop Date 2021-03-25 Time 14:50 Sent To  
Notes
2021-03-25 14:59:02PLAN REVIEW GENERATOR / ELECTRICAL
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1) PROVIDE SPECIFICATIONS FOR AUTOMATIC TRANSFER
 SWITCH. ? ATS
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2) PROVIDE NEW LOAD CALCULATIONS. INCLUDE LOAD SHARING.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 3) PROVIDE CURRENT COPY OF GENERATOR MANUFACURERS
 SPECIFICATIONS.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 4) PROVIDE CABLE SIZING BETWEEN ATS AND MDP, ATS AND
 GENERATOR, INCLUDE CONTROL CIRCUIT WIRING.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 5) PROVIDE ELECTRICAL RISER DIAGRAHM.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2022-04-04 Cont ID  
Sent By lcrespo Date 2022-04-04 Time 08:57 Rev Time 0.00
Received By lcrespo Date 2022-04-04 Time 08:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-08-12 Cont ID  
Sent By rmcdouga Date 2022-08-12 Time 13:36 Rev Time 0.00
Received By rmcdouga Date 2022-07-18 Time 07:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-07-08 Cont ID  
Sent By pvalenti Date 2022-07-08 Time 08:40 Rev Time 0.00
Received By pvalenti Date 2022-05-05 Time 07:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-04-25 Cont ID  
Sent By rmcdouga Date 2022-04-25 Time 17:26 Rev Time 0.00
Received By rmcdouga Date 2022-03-30 Time 10:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-04-22 Cont ID  
Sent By rmcphers Date 2021-04-22 Time 08:40 Rev Time 0.00
Received By rmcphers Date 2021-03-23 Time 16:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2022-04-04 Cont ID  
Sent By lcrespo Date 2022-04-04 Time 08:58 Rev Time 0.00
Received By lcrespo Date 2022-04-04 Time 08:58 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-03-24 Cont ID  
Sent By medwards Date 2021-03-24 Time 07:49 Rev Time 0.00
Received By medwards Date 2021-03-24 Time 07:49 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2022-07-27 Cont ID  
Sent By vbroglia Date 2022-07-27 Time 11:19 Rev Time 0.00
Received By vbroglia Date 2022-07-27 Time 11:19 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2022-04-05 Cont ID  
Sent By vbroglia Date 2022-04-05 Time 16:56 Rev Time 0.00
Received By vbroglia Date 2022-04-05 Time 16:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-04-21 Cont ID  
Sent By rthermid Date 2021-04-21 Time   Rev Time  
Received By rthermid Date 2021-04-21 Time   Sent To I
Notes
2021-04-21 09:04:55PROVISO:
  
 GENERATORS CANNOT ENCROACH MORE THAN 4 FEET INTO ANY
 SETBACK
  
  
 RAFAELA THERMIDOR
 ASSOCIATE PLANNER, [email protected]