| Plan Review Stops For Permit 21030892 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2021-04-20 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-04-20 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-04-20 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2021-04-20 08:45:48 | FRONT PROPERTY HAD TWO UNITS 745 NEWARK ST AND 745 1/2 | | | NEWARK ST UNITS ARE TO BE COMBINED ELIMINATING THE HALF | | | ADDRESS. REAR GARAGE IS ACCESSORY UNIT NO ADDRESS | | | NEEDED. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-03-25 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-03-25 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2021-03-25 09:31:27 | BLDG CURRENTLY HAS TWO ADDRESSES 745 NEWARK ST AND 745 | | | 1/2 NEWARK ST, WILL THIS DEMO AND REMODEL BE REMOVING | | | THE ADDITIONAL UNIT? PLEASE RESPOND TO [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-05-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-02 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-02 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-11-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-15 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-15 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2021-11-15 12:59:26 | SFR ADDITION AND SEPARATE GARAGE (PERMITS 21030892 AND | | | 21060942) | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | | | | 1) ROOFING PRODUCT APPROVAL PROVIDED FOR THE LIQUID | | | ROOFING SYSTEM STATES THAT "THIS IS NOT A WATER | | | PROOFING SYSTEM" SEE NOTE NUMBER 4 ON THE PRODUCT | | | APPROVAL (NOA18-0321.09) - MANUFACTURES NOTES - PLEASE | | | PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE PRODUCT | | | APPROVALS FOR THE ROOFING SYSTEMS. (TILE AND LOW SLOPE | | | ROOF DECKS) | | | | | | 2) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE BUILDING DESIGNER OF RECORD OR THE | | | PRODUCT APPROVAL NUMBERS NEED TO BE SHOWN ON THE | | | DRAWINGS. | | | | | | 3) PLEASE SHOW ROOF DRAINAGE SYSTEM ON THE ROOF PLAN TO | | | COMPLY WITH FBC R903.4 | | | | | | 4) PLEASE SHOW THE REQUIRED OVERFLOW SCUPPERS TO COMPLY | | | WITH FBC R903.4.1 | | | | | | 5) PLEASE SHOW ROOF VENTILATION TO COMPLY WITH FBC | | | R806.1 | | | | | | 6) PLEASE SHOW THE STEP RISER HEIGHT AND TREAD DEPTH TO | | | COMPLY WITH FBC R311.7.5 | | | | | | 7) PLEASE SHOW TUB AND SHOWER WALL AREAS TO COMPLY WITH | | | FBC R702.4.2 | | | | | | 8) PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN | | | SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE | | | SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE | | | FIRST 10 FEET (3048 MM). | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL | | | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE | | | CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. | | | IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE | | | BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 | | | PERCENT AWAY FROM THE BUILDING. | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-10-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-10-01 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-10-01 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2021-10-01 08:50:47 | NOTICE: COMMENTS APPLY TO PRIMARY PERMIT 21030892 AND | | | 1-CAR GARAGE PERMIT 21060942 | | | | | | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | COMMENTS FROM 1ST REVIEW BY ROGER MCPHEARSON ON | | | 4/15/2021. | | | | | | SFR ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) NEW FREE STANDING GARAGE NEEDS TO BE ON A SEPARATE | | | PERMIT - PLEASE ACKNOWLEDGE THIS ON THE DRAWING. | | | 2) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE NEW EXTERIOR WINDOWS, DOORS | | | AND ROOFING SYSTEMS. | | | 3) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE BUILDING DESIGNER OF RECORD OR THE | | | PRODUCT APPROVAL NUMBERS NEED TO BE SHOWN ON THE | | | DRAWINGS. | | | 4) PLEASE SHOW ROOF DRAINAGE SYSTEM ON THE ROOF PLAN TO | | | COMPLY WITH FBC R903.4 | | | 5) PLEASE SHOW THE REQUIRED OVERFLOW SCUPPERS TO COMPLY | | | WITH FBC R903.4.1 | | | 6) PLEASE SHOW ROOF VENTILATION TO COMPLY WITH FBC | | | R806.1 | | | 7) PLEASE SHOW THE STEP RISER HEIGHT AND TREAD DEPTH TO | | | COMPLY WITH FBC R311.7.5 | | | 8) PLEASE SHOW TUB AND SHOWER WALL AREAS TO COMPLY WITH | | | FBC R702.4.2 | | | 9) ROOFING SYSTEMS AND WINDOW AND DOOR PRODUCT | | | APPROVALS MAY BE DEFERRED SUBMITTALS BY LISTING ITEMS | | | TO BE DEFERRED ON THE CONSTRUCTION DOCUMENTS - | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR | | | DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING | | | OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE | | | IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. | | | THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED | | | UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN | | | APPROVED BY THE BUILDING OFFICIAL. | | | | | | COMMENTS FROM REVIEW OF 1-CAR GARAGE PERMIT 21060942 BY | | | C THROOP ON 9/28/2021. NO DUPLICATIONS. | | | | | | 10, PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE | | | WITH FBC R401.3 DRAINAGE. | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | FBC R401.3 SITE DRAINAGE | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 11. PROVIDE DESIGN PRESSURES PER FIGURE R301.2(7) | | | COMPONENT AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | | | | 12. PROVIDE ROOF SHEATHING FASTENER SCHEDULE PER DESIGN | | | PRESSURES. | | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-15 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-15 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2021-04-15 14:57:20 | SFR ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) NEW FREE STANDING GARAGE NEEDS TO BE ON A SEPARATE | | | PERMIT - PLEASE ACKNOWLEDGE THIS ON THE DRAWING. | | | 2) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE NEW EXTERIOR WINDOWS, DOORS | | | AND ROOFING SYSTEMS. | | | 3) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE BUILDING DESIGNER OF RECORD OR THE | | | PRODUCT APPROVAL NUMBERS NEED TO BE SHOWN ON THE | | | DRAWINGS. | | | 4) PLEASE SHOW ROOF DRAINAGE SYSTEM ON THE ROOF PLAN TO | | | COMPLY WITH FBC R903.4 | | | 5) PLEASE SHOW THE REQUIRED OVERFLOW SCUPPERS TO COMPLY | | | WITH FBC R903.4.1 | | | 6) PLEASE SHOW ROOF VENTILATION TO COMPLY WITH FBC | | | R806.1 | | | 7) PLEASE SHOW THE STEP RISER HEIGHT AND TREAD DEPTH TO | | | COMPLY WITH FBC R311.7.5 | | | 8) PLEASE SHOW TUB AND SHOWER WALL AREAS TO COMPLY WITH | | | FBC R702.4.2 | | | 9) ROOFING SYSTEMS AND WINDOW AND DOOR PRODUCT | | | APPROVALS MAY BE DEFERRED SUBMITTALS BY LISTING ITEMS | | | TO BE DEFERRED ON THE CONSTRUCTION DOCUMENTS - | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR | | | DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING | | | OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE | | | IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. | | | THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED | | | UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN | | | APPROVED BY THE BUILDING OFFICIAL. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-12-07 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-12-07 |
Time |
22:26 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-12-07 |
Time |
22:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-03-31 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-03-31 |
Time |
23:19 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-03-31 |
Time |
22:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2021-11-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-15 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-15 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2021-11-15 12:05:46 | SEPARATE PERMIT AND PLANS REQUIRED FOR GAS. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-04-08 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-04-08 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2021-04-08 17:30:33 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 21030892 | | | 4/8/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) P2: PLEASE SUBMIT MANUFACTURER?S SPECIFICATIONS FOR | | | THE RANGE SHOWING THE BTU LOAD AND INPUT PRESSURE- | | | SECTION G2447.1 FBC RES. PLEASE NOTE THAT THE SPECS AND | | | INSTALL MANUAL MAY BE DEFERRED AND ONSITE AT TIME OF | | | INSPECTION- SECTION 107.3.4.1 WPB. | | | | | | 2) P2: PROVIDE COMBUSTION AIR CALCULATIONS FOR THE | | | RANGE AND INDICATE HOW THE AIR WILL BE PROVIDED- | | | SECTION- G2407.1 FBC RES. | | | | | | 3) P2: UPDATE THE FBC- 2017 CODE REFERENCE IN NOTE #1. | | | THE FBC-2020 7TH EDITION CODES WENT INTO EFFECT ON | | | 12/31/2020. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | 2021-04-08 17:29:53 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 21030892 | | | 4/8/2021 | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | PLAN REVIEW RESULTS: DENIED. | | | 1) P2: PLEASE SUBMIT MANUFACTURER?S SPECIFICATIONS FOR | | | THE RANGE SHOWING THE BTU LOAD AND INPUT PRESSURE- | | | SECTION G2447.1 FBC RES. PLEASE NOTE THAT THE SPECS AND | | | INSTALL MANUAL MAY BE DEFERRED AND ONSITE AT TIME OF | | | INSPECTION- SECTION 107.3.4.1 WPB. | | | 2) P2: PROVIDE COMBUSTION AIR CALCULATIONS FOR THE | | | RANGE AND INDICATE HOW THE AIR WILL BE PROVIDED- | | | SECTION- G2407.1 FBC RES. | | | 3) P2: UPDATE THE FBC- 2017 CODE REFERENCE IN NOTE #1. | | | THE FBC-2020 7TH EDITION CODES WENT INTO EFFECT ON | | | 12/31/2020. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-03-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-03-30 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-03-30 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-07-19 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-07-19 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-07-15 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-05-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-02 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-04-20 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-03-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-03-24 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-11-03 |
Time |
16:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-04-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-15 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-24 |
Time |
17:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-08-12 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-08-12 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-07-19 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2022-08-12 11:36:46 | NO FEES PER IMPACT OFFICE. LEM | | 2022-07-19 15:51:51 | 7/19/22 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-04-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-15 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-15 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2021-04-15 15:30:24 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2021-09-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2021-04-06 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2021-04-06 |
Time |
08:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-11-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-15 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-15 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-04-08 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-04-08 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2021-04-08 16:47:08 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 21030892 | | | 4/8/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P-1: UPDATE THE FBC- 2017 CODE REFERENCE IN | | | NOTE #1. THE FBC-2020 7TH EDITION CODES WENT INTO | | | EFFECT ON 12/31/2020. | | | | | | 2) P1 NOTES: PLEASE PROVIDE PLUMBING PIPING | | | SPECIFICATIONS FOR ABOVE AND UNDERGROUND INSTALLATIONS- | | | SECTION P2609.1 FBC RES. | | | | | | 2) P1: THE SAN. RISER SHOWS A NON-COMPLIANT WET VENT IN | | | THE COMMON BATHROOM. NOT MORE THAN ONE WET-VENTED | | | FIXTURE DRAIN SHALL DISCHARGE UPSTREAM OF THE | | | DRY-VENTED FIXTURE DRAIN CONNECTION- SECTION P3108.2.1 | | | FBC RES. | | | | | | 3) P1: PROVIDE SHOWER PAN DETAILS- SECTIONS P2709.1 & | | | P2709.2 FBC RES. | | | | | | 4) P1: PROVIDE WALL AND FLOOR FINISH DETAILS FOR THE | | | SHOWER AND BATHTUB- SECTION R307.2 FBC RES. | | | | | | 5) P2: INDICATE THE TYPE OF UNDERGROUND WATER PIPING | | | AND HOW IT WILL BE PROTECTED FROM CORROSION- SECTION | | | P2603.3 FBC RES. | | | | | | 6) P2: SHOW LOCATIONS OF WATER HAMMER ARRESTORS FOR | | | WATER SUPPLY LINES TO THE WASHING MACHINE, DISHWASHER, | | | AND ICE MAKER LINE- SECTION P2903.5 FBC RES. | | | ALTERNATELY PLEASE PLACE A NOTE ON THE PLAN TO CLARIFY. | | | | | | 7) SUBMIT A PLUMBING SUB-PERMIT APPLICATION- SECTION | | | 105.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2022-05-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-02 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-02 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-11-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-15 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-15 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2021-11-15 13:00:06 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-04-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-15 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-15 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2021-04-15 15:28:05 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-07-19 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-07-19 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-07-19 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-05-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-02 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-02 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2022-05-02 09:31:35 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWINGS A200, G100, A100, A201, A101, A301, A302, | | | A303, A401, A402, A501, A502, E101, M.1 AND THE SOIL | | | REPORT DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE READER | | | - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-11-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-15 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-15 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-04-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-04-15 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-04-15 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2021-04-15 15:27:38 | THE STRUCTURAL AND MECHANICAL DRAWINGS = SIGNED AND | | | SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR | | | DIGITAL SIGNATURE - YOU CAN MAIL IN OR DROP OFF THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | | FRONT DESK IN THE BUILDING DEPT. AT THE CITY HALL |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-03-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-03-23 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-03-23 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-03-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2021-03-30 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2021-03-30 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2021-10-01 09:02:46 | COMMENTS FROM 1-CAR GARAGE PERMIT 21060942 BY FM ON | | | 9/10/2021. CT | | | | | | ZONING - NEED SURVEY/SITE PLAN SHOWING 15' OFF CENTER | | | LINE OF ALLEY AND SIDE PROPERTY LINES. | | 2021-03-30 12:10:15 | NEED SEPERATE LANDSCAPE PERMIT |
|
|