Plan Review Details - Permit 21030797
| Plan Review Stops For Permit 21030797 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-05-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-05-10 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-05-10 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-22 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-22 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2021-04-22 09:29:27 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT A DIMENSIONED DRAWING OF THE STOREFRONT LIKE | | | THE ONE THAT WAS CROSSED OUT ON THE CONTRACT. FBC | | | AMENDMENTS107.2.1 | | | | | | 2) SPECIFY THE REQUIRED WIND LOAD PRESSURES FOR THIS | | | STOREFRONT DOOR OPENING IN 170 MPH VULT EXPOSURE C. FBC | | | BUILDING SECTION 1609 | | | | | | 3) CIRCLE OR HI-LIGHT THE ITEMS LISTED IN THE PRODUCT | | | APPROVAL (INCLUDING THE DESIGN PRESSURES) THAT APPLY TO | | | THIS PROJECT. FBC AMENDMENTS107.2.1 | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-05-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-05-10 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-05-05 |
Time |
08:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-22 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-09 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2021-05-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-05-10 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-05-10 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-22 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-22 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2021-04-22 09:43:14 | WILL BE REVISITED WHEN WIND LOAD PRESSURES ARE | | | SUBMITTED. ELECTRONICALLY SUBMITTED DRAWINGS ARE | | | REQUIRED TO HAVE THE ARCHITECT?S OR ENGINEER'S DIGITAL | | | SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO SUBMIT | | | THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. AFTER | | | THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT | | | THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING | | | DEPARTMENT TO BE VERIFIED. THE ARCHITECT?S OR | | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS | | | REQUIRED TO BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER | | | FACSIMILES OF THE SIGNATURE ARE ACCEPTABLE. FS 471 & | | | 61G15, FS 481 & 61G1 |
|
|
|