Plan Review Details - Permit 21030654
| Plan Review Stops For Permit 21030654 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-05-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-05-18 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-05-18 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-04-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-04-07 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-04-07 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2021-04-07 07:47:22 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE SPACING OF THE VERTICAL MEMBERS OF THE SHADOW | | | BOX FENCE IS SPECIFIED AS 2 INCHES. THE SPACING OF | | | VERTICAL MEMBERS CAN NOT EXCEED 1-3/4 INCHES. | | | FBC-R4501.17.1.4 WHERE THE BARRIER IS COMPOSED OF | | | HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE | | | BETWEEN THE TOPS OF THE HORIZONTAL MEMBERS IS LESS THAN | | | 45 INCHES (1143 MM), THE HORIZONTAL MEMBERS SHALL BE | | | LOCATED ON THE SWIMMING POOL SIDE OF THE FENCE. SPACING | | | BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 1-3/4 INCHES | | | (44 MM) IN WIDTH. WHERE THERE ARE DECORATIVE CUTOUTS | | | WITHIN VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS | | | SHALL NOT EXCEED 1-3/4 INCHES (44 MM) IN WIDTH. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-06-11 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-06-11 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-05-17 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-04-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-14 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-03-23 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-06-10 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-06-10 |
Time |
18:13 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-06-10 |
Time |
18:13 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-04-13 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-04-13 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-04-13 |
Time |
13:32 |
Sent To |
I |
|
| Notes |
|
|
|